Records from 2016 to 2026. Most recent: inspection, 21 January 2026.
Documentation record
Registered dimensions (L × B × D)73.0 ft × 20.0 ft × 8.7 ft
Registered tonnagegross 85 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLADDING-HEARN SHIPBLDG · SOMERSET MA, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
21 January 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299594
25 February 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8084593
24 February 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8083658
21 May 2024
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7916013
6 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7875595
27 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7642957
3 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7407561
7 July 2021
Drydock Extension · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7246435
2 March 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7147031
4 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6921587
29 May 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698256
25 February 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6631884
9 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6366465
23 October 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6293680
2 March 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6097340
23 June 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5915298
2 March 2016
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5822780
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 February 2026
No resolution recorded
In accordance with sub-chapter I (46 CFR 96.06-1) The installation of all lifesaving appliances and arrangements must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Each cargo vessel must carry — Liferafts—(i) With an aggregate capacity sufficient to accommodate the total number of persons on board and that are stowed in a position providing for easy side-to-side transfer at a single open deck level; or(ii) With an aggregate capacity on each side sufficient to accommodate the total number of persons on board. Vessel maintains 01-six person liferaft that cannot accommodate the maximum persons allowed of 12 as listed on the Certificate of Inspection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 21 January 2026
No resolution recorded
Each vessel must have a line-throwing appliance approved under approval series 160.040 or 160.031. Vessel is certificated for an Oceans Route but only has one line throwing appliance and is not equipped with the four charges.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 March 2025
Resolved
As appropriate for the intended voyage, all vessels except barges, vessels operating exclusively on rivers, and motorboats other than those certificated for ocean or coastwise route, must carry adequate and up-to-date— (a) Charts; Vessels chart cards are from 2019 and not up to date.
46 CFR 97.05-5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 13 March 2025
Resolution: Updated Chart card ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 February 2025
Resolved
Markings. Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Vessels immersion suits not labeled with crew member or vessels name.
46 CFR 199.70 (c)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 13 March 2025
Resolution: Immersion suits labeled with vessels name.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 March 2022
Resolved
Piping systems shall have necessary fittings installed for safe and efficient operation. The flange installed on the port fire main piping is leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 16 March 2022
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 9 March 2018
Resolved
Make changes to breakers to match current one line diagram, or submit new electrical one-line diagram.
46cfr183.200
Action required: 10 - Deficiency Rectified
Due 3 April 2018
Resolved 30 March 2018
Resolution: Had Pacific Marine Electric come out and inspected switchboard and breakers, and updated new one line diagram.
Communications › Radio Communications › Cellular Telephone Capability
Issued 9 March 2018
Resolved
VSL must comply with requirements for radio installation including instatllaion certificates issued by FCC as set in 47CFR30. Provide copy of valid Safety Radio Certificate. 46CFR184.502
Action required: 10 - Deficiency Rectified
Due 9 April 2018
Resolved 15 March 2018
Resolution: Provided copy of vallid cert.
Engineering › Steering Gear System › Rudder Stock
Issued 23 June 2016
Resolved
Discovered bolt that did not pass through nut completely. Replace short bolt with longbolt that passes through nut completely. 46 CFR 56.25-20(a)(2)
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 27 June 2016
Resolution: Receieved email correspondence with picture clearly depicting new longer bolt and nut installed.