Records from 1982 to 1995. Most recent: inspection, 24 May 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
24 May 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 877059
17 January 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137028
19 October 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177861
21 December 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853868
31 August 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838727
22 June 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156667
21 October 1992
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945241
20 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957111
11 December 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267130
23 October 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935568
20 December 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920090
24 September 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912980
4 August 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231770
28 February 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236431
2 October 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222609
22 June 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 898981
13 October 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199773
8 June 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199089
21 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006391
15 December 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030394
15 October 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020307
1 October 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020309
26 June 1987
Drydock Extension · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318782
15 April 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318992
18 December 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001150
6 November 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321765
20 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979692
22 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 977983
20 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978280
23 January 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1286026
30 October 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976042
29 October 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272080
Lifesaving
Issued 21 October 1992
Resolved
PROVIDE AND INSTALL CG APPROVED WEAK LINKS FOR BOTH LIFERAFTS.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Accommodation/Occupational Safety
Issued 21 October 1992
Resolved
REPAIR THE GALLEY RANGE HOOD BLOWER.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Construction/Loadline
Issued 21 October 1992
Resolved
REPLACE ALL WASTED BALLAST TANK VENT SCREENS, REPLACE THE PORT AFT PEAK TANK GOOSENECK VALVE AND CLEAN THE REMANING TANK VENT SCREENS.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Electrical
Issued 21 October 1992
Resolved
INSTALL EMERGENCY LIGHTING IN ENGINE ROOM TO FACE THE PORT AND STBD EMERGENCY ESCAPES.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Engineering
Issued 21 October 1992
Resolved
REPLACE THE PORT SHIP SERVICE DIESEL GENERATOR RPM GUAGE.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Construction/Loadline
Issued 21 October 1992
Resolved
REPAIR AND TEST OPERATION OF ALL FORE PEAK REMOTE REACH RODS.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Construction/Loadline
Issued 21 October 1992
Resolved
REPAIR DECK PENETRATION TO THE STBD REACH ROD IN THE FORE PEAK TANK. ALL ITEMS D1-D6 & E1-E2 TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Unknown
Issued 21 October 1992
Resolved
PROVIDE PERMANENT NAME AND HOMEPORT OF VESSEL ON THE VESSELS STERN.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Deck/Cargo
Issued 23 October 1991
Resolved
HYDROSTATICALLY TEST CARGO OIL TRANSFER HOSE TO 225 PSI AND PROVIDE TEST RESULTS TO [name withheld].
Condition: Unknown
Due 23 October 1991
Resolved 23 October 1991
Navigation
Issued 23 October 1991
Resolved
PROVIDE 33CFR PARTS 1-199 ON BOARD VESSEL. REQUIREMENT MAY BE CLEARED BY SUBMITTING STATEMENT FROM MASTER THAT CFR ON BOARD TO [name withheld].
Condition: Unknown
Due 23 October 1991
Resolved 23 October 1991
Electrical
Issued 23 October 1991
Resolved
PROVE PROPER OPERATION OF PORT GENERATOR TACHOMETER.
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Electrical
Issued 2 October 1989
Resolved
REPAIR OVERSPEED DEVICE AND ALARM ON STARBOARD GENERATOR.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Accommodation/Occupational Safety
Issued 2 October 1989
Resolved
REPAIR OR REPLACE GALLEY STOVE FAN, LIGHT COVER AND GREASE SCREEN.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Engineering
Issued 2 October 1989
Resolved
PROVIDE SIGHT GLASS PROTECTION FOR MAIN ENGINES AND GENERATORS EXPANSION TANKS.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989
Resolved
REPAIR OR REPLACE PORT GENERATOR TACHOMETER.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Fire Fighting
Issued 2 October 1989
Resolved
PROVIDE COPY TO [name withheld], OF FIRE FIGHTING FIXED AND PORTABLE SERVICING CERTIFICATE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Lifesaving
Issued 2 October 1989
Resolved
REPLACE ALL OUTDATED HAND HELD SMOKE AND RED FLARES, AND SHOULDER LINE THROWING GUN CARTRIDGES.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Engineering
Issued 13 October 1988
Resolved
REPAIR LOW FUEL OIL DAYTANK P/S ALARMS AND LOSS OF STARTING AIR ALARM.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Lifesaving
Issued 13 October 1988
Resolved
PROVIDE SERVICE REPORT AND MASTER'S STATEMENT OF INSTALLATION OF LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Unknown
Issued 13 October 1988
Resolved
REPLACE STRAIGHT STREAM FIRE NOZZLE ON CARGO DECK WITH A COMBINATION TYPE.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Deck/Cargo
Issued 13 October 1988
Resolved
PROVIDE REMOTE SHUTDOWNS FOR CARGO PUMPS.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Deck/Cargo
Issued 13 October 1988
Resolved
REMOVE TOW WINCH AIR RECEIVER FROM OPERATION OR PROVE ASME STD AND HYDRO- TEST TO 1-5 MAWP.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Navigation
Issued 1 October 1987
Resolved
INSTALL A STERN LIGHT AS PER INTERNATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 1 October 1987
Resolved 1 October 1987
Lifesaving
Issued 6 November 1986
Resolved
CONDUCT ANNUAL SERVICING OF LIFERAFT HYDROSTATIC RELEASES.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Lifesaving
Issued 6 November 1986
Resolved
PROVE PROPER OPERATION OF DAVIT FOR RESCUE BOAT.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Lifesaving
Issued 6 November 1986
Resolved
PROVIDE APPROVED USCG RESCUE BOAT AS REQUIRED BY 46 CFR 94.10-5.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Fire Fighting
Issued 6 November 1986
Resolved
PROVIDE MARINE APPROVED MOUNTING BRACKET FOR B-II LOCATED IN THE GALLEY.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Deck/Cargo
Issued 6 November 1986
Resolved
REPLACE AND REWIRE MOTOR CONTROLLER AND PROVE PROPER OPERATION OF ELECTRIC BREAK FOR ANCHOR WINDLASS.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Construction/Loadline
Issued 6 November 1986
Resolved
REPLACE BROKEN GLASS IN STARBOARD BRIDGE DOOR AND FRONT GLASS STARBOARD SIDE PILOT HOUSE.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Construction/Loadline
Issued 6 November 1986
Resolved
PERMANENTLY MARK LOADLINE ON VESSEL'S HULL. THIS IS A REISSUE FROM 20 JUNE1985.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Deck/Cargo
Issued 6 November 1986
Resolved
MAKE PERMANENT REPAIRS TO CRACKED WELDS IN THE BAFFLE PLATES IN THE 4 DRY BULK CARGO TANKS. REPAIRS SHALL BE MADE IN ACCORDANCE WITH WRITTEN MANU- FACTURERS REPAIR PROCEDURES AND SHALL BE PERFORMED BY AN ASME CODE SHOP. THESE WRITTEN PROCEDURES MUST BE SUBMITTED TO MIONY FOR APPROVAL.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Deck/Cargo
Issued 6 November 1986
Resolved
REPAIR AND RESET SAFETY RELIEF VALVES ON THE (4) FOUR BULK DRY CARGO TANKS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Engineering
Issued 6 November 1986
Resolved
REPLACE PRESSURE GUAGE ON DISCHARGE SIDE OF BILGE PUMP.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Deck/Cargo
Issued 6 November 1986
Resolved
REPLACE THE FOLLOWING PRESSURE VESSEL VALVES: HYD OIL VENT STARBOARD, LUBE OIL VENT STARBOARD, GEAR OIL VENT PORT AND BILGE SLOP TANK VENT.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Electrical
Issued 6 November 1986
Resolved
REPLACE TWIST SPLICES AND REMOVE OLD BATTERY CONNECTIONS FROM EMERGENCY BATTERY BOX AND PROPERLY BRACE BATTERIES.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Electrical
Issued 6 November 1986
Resolved
PROVIDE AN ADDITIONAL EMERGENCY LIGHT IN GALLEY AREA.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Engineering
Issued 6 November 1986
Resolved
PROVE PROPER OPERATION ON HIGH TEMP ALARM FOR PORT MAIN ENGINE.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Accommodation/Occupational Safety
Issued 6 November 1986
Resolved
INSTALL FAN IN GALLEY RANGE HOOD.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Electrical
Issued 6 November 1986
Resolved
REINSTALL THE RACOR FILTER HOUSING HEAT DEFLECTOR SHIELD ON STARBOARD GENERATOR PRIME MOVER.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986
Lifesaving
Issued 20 June 1985
Resolved
PROVIDE MEANS OF EASILY LAUNCHING LIFERAFTS FROM BRIDGE DECK OR MOVE TO A LOWER DECK.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Lifesaving
Issued 20 June 1985
Resolved
OBTAIN PROPER SERVICING CERTIFICATE FOR B.F. GOODRICH LIFERAFT. SER. NO. 13 LOT 108.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Construction/Loadline
Issued 20 June 1985
Resolved
PERMANENTLY MARK LOAD LINES ON VESSEL BULK.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Unknown
Issued 22 May 1985
Resolved
REINSTALL FLAME DEFLECTOR SHIELDS ON RACOR FUEL FILTERS INSTALLED ON MAIN E.M.D. GENERATOR ENGINES.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Unknown
Issued 22 May 1985
Resolved
PROCEED TO DUBAI AND DRYDOCK VESSEL NO LATER THAN 10 JUNE 1985.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Unknown
Issued 22 May 1985
Resolved
MAKE PERMANENT REPAIRS TO CRACKED WELDS IN THE BAFFLE PLATES OF FOUR (4) DRY BULK CARGO TANKS.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Unknown
Issued 20 February 1985
Resolved
POST ONBOARD A USCG APPROVED STABILITY LETTER PRIOR TO THE CARRIAGE OF CARGO.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985
Unknown
Issued 20 February 1985
Resolved
HAVE THE PORT SIDE LIFERAFT, SWITLIK SPC-MM21, SERVICED AT A USCG APPROVEDLIFERAFT SERVICING FACILITY.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985
Unknown
Issued 20 February 1985
Resolved
PROVIDE A RESCUE BOAT AND LAUNCHING DAVIT ON THE VESSEL PRIOR TO THE DEPARTURE FROM BOMBAY HARBOR.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985
Unknown
Issued 20 February 1985
Resolved
PROVIDE ILLUMINATION FOR THE PORT AND STARBOARD LIFERAFT STATIONS PRIOR TO THE DEPARTURE FROM BOMBAY HARBOR DURING NIGHT OPERATIONS
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985
Unknown
Issued 20 February 1985
Resolved
REINSTALL THE RACOR FUEL FILTER HOUSING HEAT DEFLECTOR SHIELDS ON BOTH MAIN ENGINES AND BOTH GENERATOR ENGINES.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985
Unknown
Issued 20 February 1985
Resolved
REPAIR APEX VOID STRUCTURE WELD FRACTURES IN WAY OF ALL FOUR BULK DRY MUD TANKS MANUFACTURED BY TRINITY INDUSTRIES, INC. REPAIRS SHALL BE MADE IN ACCORDANCE WITH WRITTEN MANUFACTURE'S REPAIR PROCEDURES AND SHALL BE PERFORMED BY AN ASME CODE SHOP PRIOR TO USE.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985
Unknown
Issued 30 October 1984
Resolved
PLACE TWO (2) COPIES OF LAWS GOVERNING MARINE INSPECTIONS ONBOARD THE VESSEL.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
HAVE ALL PRESSURE VESSELS HYDROSTATICALLY TESTED OR INTERNALLY EXAMINED.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
TEST ALL CARTO TANK RELIEF VALVES.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
THE DRYDOCK EXTENSION WILL BE GRANTED UPON RECEIPT BY THIS OFFICE A LETTER OR TELEX FROM GULF FLEET REQUESTING THE EXTENSION INCLUDING THE LENGTH OF THE EXTENSION REQUESTED.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
HAVE BOTH HYDROSTATIC RELEASES SERVICED BY A U.S. COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
REPLACE RING BUOY ON PORT SIDE AFT OF THE DECKHOUSE.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
REPAIR REMOTE VENTILATION SHUTDOWNS IN THE PILOT HOUSE AND AT THE STATION AFT OF THE DECK HOUSE.
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984
Unknown
Issued 30 October 1984
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 October 1984
Resolved 30 October 1984