Records from 1982 to 1994. Most recent: inspection, 2 May 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
2 May 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 868582
23 June 1993
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1156219
14 January 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 830533
28 May 1992
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1265620
21 January 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 29136
16 December 1991
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 950763
13 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905107
23 April 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1236793
11 April 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244139
7 March 1991
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236789
1 December 1990
Deficiency Check · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1215371
14 November 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928531
25 October 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904383
17 September 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933456
24 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231520
22 November 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902875
8 November 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1202744
25 October 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 889890
14 August 1988
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1344831
28 June 1988
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1208057
18 November 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1028607
22 January 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1012030
27 October 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1327761
24 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998144
15 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295542
4 December 1985
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298836
25 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290953
14 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286465
18 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281358
23 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281151
28 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971303
5 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279567
27 June 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276391
26 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966471
12 November 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965011
Documentation
Issued 28 May 1992
Resolved
SUBMIT FOR APPROVAL FIRE CONTROL PLAN FO MODU VANGUARD II.
Condition: Unknown
Due 30 September 1992
Resolved 20 October 1992
Documentation
Issued 16 December 1991
Resolved
PROVIDE COPIES OF ANNUAL CRANE INSPECTION CERTIFICATES.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Lifesaving
Issued 25 October 1990
Resolved
PROVIDE TILLER EXTENSION HANDLE FOR MEANS OF EMERGENCY STEERING BOTH PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
PROVIDE 20 ADDITIONAL UNEXPIRED LIGHTS FOR SPARE LIFE JACKETS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
PROVE PROPER OPERATION OF HAND OPERATED BILGE PUMP IN STARBOARD LIFEBOAT.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE ALL BROKEN WIRE SUPPORTS IN SHALE SHAKER IN ACCORDANCE WITH IEEE-45
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE WIRES WITH BROKEN ARMOR TO SHALE SHAKERS #1, #2.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE DOCUMENTATION CONDUCTIVE BELTS AND BEING USED ON DEGASSER AND SHALESHAKER DRIVES.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE PROPER EXPLOSION PROOF JUNCTION BOX AND PROPER WIRE (ARMORED OR MI)POWER SUPPLY SYSTEM FOR LOGGING UNIT STARBOARD SIDE SHALE SHAKER.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE FOR CLASS I DIVISION I INSTALLATION PHONE JUNCTION BOX ON TOP OF SHAKER.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Unknown
Issued 25 October 1990
Resolved
RESCINDED
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Accommodation/Occupational Safety
Issued 25 October 1990
Resolved
PROVIDE REPLACEMENT OR REPAIRS TO URINALS AND SINK LOCATED IN CREW'S QUARTERS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE COVER FOR EXPLOSION PROOF PLUG BOX LOCATED BEHIND BARRED BARREL -O-GRAPH PANEL RIG FLOOR.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROPERLY INSTALL WIRING ON THE STARBOARD SIDE OF THE RIG FLOOR IN ACCORDANCE WITH IEEE - 45.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE VISUAL OR AUDIBLE ALARM FOR "WMED" GAS DETECTOR PANEL STARBOARD SIDE OF THE RIG FLOOR. (VISUAL INDICATOR CANNOT BE READILY SEEN WHERE IT IS PRESENTLY INSTALLED)
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROPERLY HANG ALL HORIZONTAL WIRE RUNS IN OVERHEAD ABOVE CELLAR DECK IN ACCORDANCE WITH IEEE - 45.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE WIRE WITH BROKEN BRAID TO EXPLOSION PROOF SPEAKER HORN ABOVE TRIP TANK.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Navigation
Issued 25 October 1990
Resolved
PROVIDE TWO ADDITIONAL RELIEF VALVES FOR DRY BULK TANKS AND TEST IN THE PRESENCE OF A COAST GUARD INSPECTOR. DRY BULK TANKS IN QUESTION ARE NOT TOBE USED PRIOR TO BEING FITTED WITH PROPER RELIEF VALVES.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Navigation
Issued 25 October 1990
Resolved
PROVIDE RELIEF VALVES ON AIR RECEIVERS (1) UNDER RIG FLOOR, WORKING PRES- SURE = 125 PSI. (2) MACHINERY SPACE WORKING PRESSURE = 137 PSI; WHICH CAN BE SET NOT TO EXCEED +/- 10% OF RELIEF VALVE SETTING. BOTH VALVES SET AT 165 LBS/IN2
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990
Resolved
REPAIR LEAK TO PIPING ON MARINE SANITATION DEVICE; REPAIR MARINE SANITATIONDEVICE (CURRENTLY INOPERATIVE INDICATING "CELL ALARM"), PROVIDE PROTECTIVE GUARD TO MARINE SANITATION DEVICE PUMP DRIVE SHAFT.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990
Resolved
PROVIDE BOOTS, GLOVES, AND CLOTHING FOR BOTH FIREMAN'S OUTFITS AS PER 46 CFR 108.497 (PROXIMITY SUITS DO NOT MEET THIS REQUIREMENTS.)
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990
Resolved
REFILL / REHYDRO PRIMARY SCBA BOTTLE; REFILL STANDBY BOTTLE FOR FIREMAN'S OUTFITS IN ENGINEERING SPACES.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
PROVIDE TWO ADDITIONAL PARACHUTE FLARES FOR RIG REQUIREMENTS, CURRENTLY THERE ARE ONLY TEN (10) ON BOARD.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Construction/Loadline
Issued 25 October 1990
Resolved
PROVIDE ADDITIONAL MEANS OF EXCAPE FROM VESSEL WHILE ELEVATED IN THE FORM OF A FIXED LADDER (CURRENTLY ONLY ONE EXISTS ON BOW LEG) 46 CFR 108.151.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Accommodation/Occupational Safety
Issued 25 October 1990
Resolved
CLEAN ALL FOOD PARTICLES / SCRAPS UNDERNEATH STORAGE RACKS IN GALLEY. CLEAN DECK OF CHILL BOX AND FREEZER BOX.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Navigation
Issued 25 October 1990
Resolved
REPAIR GENERAL ALARM BELL OUTSIDE GALLEY.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Construction/Loadline
Issued 25 October 1990
Resolved
REPLACE PIPING PENETRATION WITH DOUBLER PLATE TO MAIN BILGE SUCTION LINE LOCATED BY BILGE PUMP #2.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
PROVIDE 25 ADDITIONAL QUARTS (200 1/8 OUNCE PACKETS) TO PORT LIFEBOAT.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
CONDUCT WEIGHT TESTS OF BOTH PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
RECHARGE TWO OF THREE AIR BOTTLES IN STARBOARD LIFEBOAT.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
PROVIDE 13 ADDITIONAL QUARTS (104 1/8 OUNCE PACKETS) OF APPROVED WATER TO STARBOARD LIFEBOAT.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE EXPLSION PROOF SWITCH BOX WITH SEALED FITTINGS TO "ELEC" SYSTEM EMERGENCY STOP RIG FLOOR).
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE DISTORTED WIRING (TWISTED UNDER HEAVY STRAIN TO PHONE BOX BY DRILL-ER'S CONSOLE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPAIR LOSS OF PURGE LIGHTS TO VARCO PANEL BY DRILLER'S CONSOLE, RIG FLOOR.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Lifesaving
Issued 25 October 1990
Resolved
PROVIDE WEIGHT TEST OF BOTH LIFE BOATS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE BATTERY POWERED EMERGENCY LIGHTING FOR EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE WASTED LOWER VENT TO EMERGENCY GENERATOR INTAKE.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
CONDUCT TESTS AND LOG IN ACCORDANCE WITH 46 CFR 109.211 EMERGENCY LIGHTING AND POWER SYSTEMS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990
Resolved
RE - TIGHTEN PACKING ON #2 FIRE PUMP (LEAKING EXCESSIVELY).
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Accommodation/Occupational Safety
Issued 25 October 1990
Resolved
REMOVE CUTTING BLOCK FROM GALLEY, NUMEROUS SCRAPS OF FOOD ARE TRAPPED IN OPEN SEAMS (HEALTH HAZARD).
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
TEST EMERGENCY GENERATOR AUTO BUS TRANSFER AND OPERATION IN THE PRESENCE OFA COAST GUARD INSPECTOR.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE 3 OF 5 BATTERIES FOR EMERGENCY GENERATOR STARTING SYSTEM.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
PROVIDE FLAME SHIELD AND LAGGING FOR EXHAUST OF EMERGENCY GENERATOR.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPAIR / PROVIDE FOR INSPECTION, LOSS OF VENTILATION ALARMS FOR MUD PITS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Electrical
Issued 25 October 1990
Resolved
REPLACE ALL RUNS OF WIRING WITH BROKEN ARMOR ON JUNCTION BOXES AND LIGHTS BY MUD CIRCULATING AND DESILTER PUMPS.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Fire Fighting
Issued 25 October 1990
Resolved
BLANK OF "FIRE MAIN DECK WASH" ON PORT SIDE OF RISER TO FIRE STATION #7.
Condition: Unknown
Due 25 October 1990
Resolved 25 October 1990
Unknown
Issued 17 September 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Unknown
Issued 17 September 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Unknown
Issued 17 September 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Unknown
Issued 17 September 1990
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 17 September 1990
Resolved 17 September 1990
Documentation
Issued 22 November 1989
Resolved
RESUBMIT THE OPERATIONS MANUAL FOR APPROVAL.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Fire Fighting
Issued 22 November 1989
Resolved
RELABEL THE MOTOR ROOM CO2 SYSTEM AND CORRECT THE INSTRUCTION TO AGREE WITH THE SYSTEM OPERATION.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Deck/Cargo
Issued 22 November 1989
Resolved
CONDUCT ANNUAL SURVEY ON CRANES.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989
Resolved
MAKE PROPER ENDING FOR DEAD END CABEL BEHIND SWACO UNIT ON DRILL FLOOR.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989
Resolved
REPAIR THE DRAW WORKS MOTOR J-BOX PURGE LOSS ALARM.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989
Resolved
MOVE THE EMERGENCY LIGHT OUT SIDE THE FIVE FOOT CLASS 1 DIV II PLUME BY THEMUD PIT ROOM.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Unknown
Issued 25 October 1988
Resolved
MAKE EMERGENCY GENERATOR AVAILABLE FOR TESTS OF AUTO START, AUTO BUS TIE TRANSFER, LOW OIL PRESSURE ALARM, LOW OIL PRESSURE SHUT DOWN, REVERSE POWERRELAY AND OVERSPEED SHUTDOWN. ALSO TEST #5 GENERATOR CRANKING PANEL AND SYNCHRONIZATION OF #5 GENERATOR FROM IT'S SWITCHBOARD.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Fire Fighting
Issued 27 October 1986
Resolved
HYDRO TEST ALL PORTABLE FIRE EXTINGUISHERS THAT HAVE NOT BEEN HYDRO'D WITHIN THE LAST FIVE YEARS.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Lifesaving
Issued 27 October 1986
Resolved
INSTALL A COVER OVER THE WIRING AT THE PORT AND STARBOARD LIFEBOAT EMBARKA-TION DECK THRESHOLD TO PROTECT IT WHILE LOADING THE LIFEBOATS.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Documentation
Issued 27 October 1986
Resolved
SUBMIT FOR RECALCULATION THE STABLITY DATA CHANGES RESULTING FROM THE ADDITION OF 24' LEG SECTIONS.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Electrical
Issued 27 October 1986
Resolved
TEST THE GAS DETECTION SYSTEM ON THE DRILL FLOOR.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Construction/Loadline
Issued 27 October 1986
Resolved
REPLACE THE TWO MALFUNCTIONING 3" GLOBE ANGLE CHECK VALVES AT THE PORT AND STARBOARD BILGE/BALLAST MANIFOLDS.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Electrical
Issued 27 October 1986
Resolved
PROPERLY SECURE THE WIRE RUNS IN WAY OF THE #2 LIFEBOAT WINCH CONTROL.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Lifesaving
Issued 27 October 1986
Resolved
OPERATIONALLY TEST BOTH LIFEBOATS IN THE WATER AND MAKE APPROPRIATE LOG ENTRIES.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Electrical
Issued 27 October 1986
Resolved
TEST LOW LUBE OIL SHUTDOWNS ON ALL FIVE GENERATORS.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Electrical
Issued 27 October 1986
Resolved
TEST THE AUTOMATIC START ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 27 October 1986
Resolved 27 October 1986
Documentation
Issued 15 January 1986
Resolved
SUBMIT FOR RECOLCULATION THE STABILITY DATA DUE TO THE ADDITION OF AN ADDITIONAL 24' OF LEG LENGHT.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Lifesaving
Issued 15 January 1986
Resolved
REFILL AIR BOTTLE IN THE STARBOARD LIFE BOAT CURRENTY + 16OO PSI 1800 PSI REQUIRED
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Documentation
Issued 15 January 1986
Resolved
PROVIDE APPROVAL LETTER FOR THE COMBUNATION HAZARDOUS LOCATION/FIRE CONTROLPLAN DATED 08AUG1983.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Lifesaving
Issued 15 January 1986
Resolved
REPAIR GASKETS ON THE DOORS TO THE STARBOARD LIFEBOAT.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Documentation
Issued 15 January 1986
Resolved
PROVIDE VALID "CERTIFICATE OF FINANCIAL RESPONSIBILITY" (FMC)
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Fire Fighting
Issued 15 January 1986
Resolved
PROVIDE SAMPLE HOSE FOR O2-LFL METER WITH APPROPIATE FITTINGS TO MATCH UP TO METER AND PROBE.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Accommodation/Occupational Safety
Issued 15 January 1986
Resolved
PROVIDE 15 TRIANGULAR BANDAGES FOR THE FIRST AID KIT.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Lifesaving
Issued 15 January 1986
Resolved
PROVIDE SAFETY BELT FOR "SAFETY CLIMB" MOUNTED ON THE BOW LEG.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Lifesaving
Issued 15 January 1986
Resolved
SUBMIT FOR APPROVAL THE USE OF JACOBS LADDERS CURRENTLY INSTALLED.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Construction/Loadline
Issued 4 December 1985
Resolved
MAKE DRILL WATER TANKS GAS FREE AND AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Unknown
Issued 14 November 1984
Resolved
SUBMIT TO [name withheld] FOR REVIEW AND APPROVAL RIG'S CONSTRUCTION PORTFOLIO REF 46 CFR 107.305HH
Condition: Unknown
Due 14 November 1984
Resolved 14 November 1984
Deck/Cargo
Issued 14 November 1984
Resolved
PROVIDE EVIDENCE OF ANNUAL CRANE INSPECTION WAS DONE IN ACCORDANCE WITH A SPECIFICATION RE 46 CFR 107.259.
Condition: Unknown
Due 14 November 1984
Resolved 14 November 1984
Unknown
Issued 14 November 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL VANGUARD II DN652579
Condition: Unknown
Due 14 November 1984
Resolved 14 November 1984
Deck/Cargo
Issued 14 November 1984
Resolved
PROVIDE RELIEF VALVES TO THE DIESEL WINCHES STARTING AIR TANKS WITH A SET PRESSURE LESS THAN 165 PSIG REF 46CFR 54.15.
Condition: Unknown
Due 14 November 1984
Resolved 14 November 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE PROOF THAT THE TEMPERATURE SENSE AND FLOW METER IN THE MUD LINE TO THE TRIP TANK IS INTRINSICALLY SAFE.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE AND POUR EYS FITTINGS FOR DC POWER SUPPLY FOR CRT, GENERAL ELEC- TRONIC UNIT AND ITS POWER SUPPLY, AND THE ALARM HORN.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE VANGUARD II, DN652579.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
LABEL ALL MECHANISMS WITH RELEASE PINS TO CORRESPOND WITH LOCAL OPERATING INSTRUCTIONS.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE AND POST A DIAGRAM OF THE CO2 SYSTEM FOR THE GENERATOR ROOM AND INSTRUCTION FOR OPERATING THIS SYSTEM LOCALLY.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE AN EXPLOSION PROOF HORN FOR WMCO MUD MONITOR ON DRILL FLOOR.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE & POST WIRING DIAGRAMS & CIRCUIT DIRECTORIES FOR GENERAL ALARM PAN-ELS IN EMER. GEN. ROOM & GENERAL ALARM DISTRIBUTION PANELS THROUGHOUT RIG.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE AND POST OPERATING INSTRUCTIONS FOR #5 (EMERGENCY) GENERATOR FOR ALL MODES OF OPERATION.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
PROVIDE LABEL PLATES FOR BATTERY CHARGERS IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
REPAIR AND TEST THE AIR PURGE SYSTEM FOR THE DRILLER'S CRT MONITOR TO THE SATISFACTION OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
INSTALL AN EXPLOSION PROOF LIGHT ABOVE THE DOOR IN THE COMPANIONWAY TO THE ENGINE ROOM.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 5 January 1984
Resolved
OBTAIN AND POST THE CORRECT SETTINGS FOR ALL ADJUSTMENTS ON THE GENERATOR, BUS TIE, TRANSFORMER, AND JACKING CIRCUIT BREAKERS.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 26 April 1983
Resolved
PROVIDE ON BOARD A U. S. COAST GUARD APPROVED FIREFIGHTING AND LIFESAVING PLAN AND A HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983