Records from 2005 to 2025. Most recent: inspection, 12 August 2025.
Inspection history · 75
12 August 2025
In-Service Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8209406
6 March 2025
Administrative Inspection · Annual Inspection · Permit to Proceed
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8093508
2 August 2024
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7973099
1 August 2024
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7977176
26 July 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7967864
26 May 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7924799
1 February 2024
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7858942
10 January 2024
Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7848589
7 January 2024
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7847448
28 December 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7843285
3 November 2023
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7820235
30 September 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7806816
20 September 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7798707
21 June 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7754832
15 June 2023
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7716507
17 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7636060
4 May 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7771519
7 February 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7642696
28 September 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568118
21 September 2022
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7563944
28 June 2022
Examination of Repairs · Damage Survey · Administrative Inspection · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7489314
24 June 2022
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7540235
15 April 2022
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7431942
14 April 2022
Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439373
25 March 2022
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7418758
2 December 2021
In-Service Inspection · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7378510
3 November 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7348028
20 October 2021
Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7336272
13 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7335265
30 July 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7275471
30 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7186337
29 April 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7214472
30 March 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7165805
7 July 2020
MTSA/ISPS Verification · Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6992833
6 July 2020
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7003131
29 June 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7021147
18 May 2020
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6955496
18 May 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6959103
2 April 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6945758
19 March 2020
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928751
3 March 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923254
11 February 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6920685
3 February 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6901609
2 January 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6881626
17 December 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6875192
9 December 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6870012
25 October 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6841920
20 September 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6816663
20 June 2019
Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6754469
28 May 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6775755
9 January 2019
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6608010
6 December 2018
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6592972
20 November 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6584239
16 November 2018
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6582277
11 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6537809
4 September 2018
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6545549
21 August 2018
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6519064
17 August 2018
Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6515023
26 July 2018
Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6491689
29 June 2018
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6459913
13 April 2018
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6409714
12 April 2018
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685314
3 April 2018
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6383865
5 March 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6367287
24 January 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6343278
15 November 2017
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6307632
26 September 2017
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6275580
17 August 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6256897
15 August 2017
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6241904
26 January 2017
MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6078096
18 November 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323377
1 November 2016
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6033114
14 October 2016
Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6022707
6 May 2016
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6044099
10 March 2016
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068060
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 February 2026
No resolution recorded
Before the vessel leaves port and at all times during
the voyage, each lifesaving appliance must be in working order and ready for immediate use. Vessels #7 lifeboat lowering wire parted during routine maintenance and the #9 lifeboat davit will not lower. Vessels total passenger count is reduced by 240 passengers making the total passenger count allowed until repairs are made 2,200 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 February 2026
No resolution recorded
On Monday, February 9, 2026, Sector Mobile was notified of leaking sewage pipe inside of the 4C ballast tank, which caused the sewage tank to fill up when the 4C ballast tank was filled to over 91% full. The suspect pipe was determined to be located in the shower drain in 4-62-2. The company is making preparations to attend dry dock in March 2026 and requested a temporary repair which was approved by ABS with Sector Mobile concurrence. Vessel must complete temporary repair proposal and monitoring plan submitted on 09FEB26. Permanent repairs shall be made prior to completion of next dry dock due 31MAR2026.
46 CFR 72.01-15(a)
Action required: 705 - Other - as specified
Due 31 March 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 6 March 2025
No resolution recorded
Vessel has severe damage between the 4C ballast tank and anti-roll tank that has been temporarily repaired to the satisfaction of the USCG. Complete permanent repairs during the 2025 dry docking. Vessel must acquire a permit-to-proceed prior to departing the San Diego inspection zone to complete repairs.
Cite: 46 CFR 92.01-10
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2025
Resolved
Starboard tender's powered bilge pumps are not operational. Conduct repairs of the affected pumps and demonstrate satisfactory operation for attending USCG marine inspector. The starboard tender may not conduct tendering operations until this deficiency is rectified.
Cite: 46 CFR 182.520.
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 March 2025
Resolved
Both tenders do not have serviceable fire-buckets. Replace both tender's fire buckets in accordance with 46 CFR 181.610. Neither tender may not conduct tendering operations until this deficiency is rectified.
Cite: 46 CFR 181.610.
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: New buckets were acquired.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 2 August 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 April 2025
Resolution: Temporary repairs have been completed. Another deficiency will be issued to complete permanent repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 July 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The No. 7 Liferaft Davit was found to be inoperable due to excessive wastage of the gear box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2024
Resolved 18 April 2025
Resolution: Gearbox was replaced; witnessed satisfactory davit test using "B" weight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 July 2023
Resolved
The #5 lifeboat's engine failed multiple times during in-water lifeboat testing. Identify cause of failure and repair. The #5 lifeboat may not be used to determine the vessel's total person count until this deficiency has been rectified to the satisfaction of the attending USCG marine inspector.
Cite: 74 SOLAS (1997) Reg 20.1.1.1
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Witnessed satisfactory boat meaneuvering test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 June 2023
Resolved
While vessel personnel were conducting weekly testing of lifeboat engine, found the engine would not turnover. Further inspection found the engine oil sump to be full of water. Repair engine. Passenger count shall be reduced by 133 until repairs are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Witnessed satisfactory boat meaneuvering test.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 May 2023
Resolved
During abandon ship drills, it was discovered that the No. 1 Tender Vessel's davit was not fully operational, with electrical, hydraulic, and brake issues. The No. 1 Tender Vessel may not be used to determine the vessel's total persons count until this deficiency has been rectified to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 4 October 2023
Resolution: Brakes were replaced and overhauled. Witnessed satisfactory brake test.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2023
Resolved
Received a failed foam analysis report for the AFFF stored in the flight deck and machinery space storage tanks. Both AFFF samples did not meet the required expansion ratio requirements of 4.5%. Please submit a satisfactory foam analysis report within 30-days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 8 June 2023
Resolution: Received a satisfactory foam analysis report from National Foam for the AFFF stored in the flight deck (5.5%) and machinery space (7.9%) storage tanks; invoice No. NFAN010403.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 September 2022
Resolved
Each bus-tie between a main switchboard and an emergency switchboard must: (a) Disconnect automatically upon loss of potential at the emergency switchboard; (b) Be arranged to prevent parallel operation of an emergency power source with any other source of electric power, except for interlock systems for momentary transfer of loads. Vessel reported that its EDG Auto-Manual selector switch is malfunctioning to include its Auto mode function. During return voyage to San Diego, CA, vessel
shall provide a watch stander in the EDG space (with sufficient communications equipment) to activate the EDG for any possible loss of power. If manning is insufficient to maintain this additional watch station, provide a proposal of equivalent safety. During transit within port (from sea buoy to final berth) vessel shall maintain the EDG ready on standby to take electrical load in case of loss of power. Upon safe return vessel shall make permanent repairs to EDG.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 October 2022
Resolution: Witnessed operation by Attending MI; ALL SAT
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 28 September 2022
Resolved
All emergency equipment shall be maintained in an operative condition. Vessel reported GMDSS SAT C system
cannot log in or connect to any region. System will not sych with NSC or NCC. Upon return to home port vessel
vessel will make permanent repairs.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 13 February 2023
Resolution: Cleared deficiency off the servicing report provided by J & L Marine Electronics. Added servicing report to the Documents Tab.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 September 2022
Resolved
Each fall used in a launching appliance must be renewed when necessary due to deterioration or at intervals of not more than 5 years, whichever is earlier. Both tender boat davits are past their 5 year maintenance window. Both tenders may not be utilized until appropriate maintenance of the davits has been completed. The tenders may not be used to determine the vessel's total person count until deficiency is rectified.
Action required: 15 - Rectify deficiencies by next port
Resolved 5 April 2023
Resolution: Received the Fassmer certificates of serviceability reports for the No.1 and No.2 life boat davits after this deficiency had been rectified to the satisfaction of the attending technician. Please see Fassmer Service Reports 2023-02-047327 & 047328.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 28 September 2022
Resolved
Accommodations provided for officers and crew on all vessels shall be securely constructed, properly lighted, heated, drained, ventilated, equipped, located, arranged, and insulated from undue noise, heat, and odors. Seals on the vessel's deck drains connected to the sewage system have been reported as not being sufficiently maintained, resulting in releases of hydrogen sulfide and VOCs to accommodation spaces. Complete adequate maintenance of deck drain seals to prevent further sewage vapor releases.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2023
Resolved 17 May 2023
Resolution: Deck seal drain maintenance was completed and the traps were refilled with water to address this concern of vapor release through the floor drains. This item will require regular maintenance going forward by the vessel's crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 January 2022
Resolved
Fire door F.S.D. 70 gets caught on a nearby escape scuttle during closure. Adjust F.S.D. 70 as necessary to prevent it from getting caught.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 9 February 2022
Resolution: Fire door has been properly adjusted. Witnessed satisfactory door closing test.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 January 2022
Resolved
02 open cable transits were discovered in stair tower 4-68-2. Properly re-pack both cable transits with approved materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 9 February 2022
Resolution: Cable transits were properly repacked and inspected.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 January 2022
Resolved
02 open cable transits were discovered in the bulkheads about fire doors F.S.D. 87 and F.S.D. 82. Properly re-pack both cable transits with approved materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 9 February 2022
Resolution: Cable transits were properly repacked and inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 January 2022
Resolved
The #9 lifeboat stalls during operation and has difficulty starting. Diagnose and repair the cause of the failure and conduct a satisfactory operational test in the presence of a USCG marine inspector. Total persons authorized on board reduced to 2,184.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 March 2022
Resolution: Witnessed satisfactory test of the lifeboat in the water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2021
Resolved
The emergency switchboard was found with a 100 amp breaker installed for the keep warm emergency generator heater. The circuit conductor size is rated for 64 amps. Tag-out current circuit breaker, provide keep warm heater with adequate over current protection and update ship's drawings.
Action required: 705 - Other - as specified
Due 25 April 2022
Resolved 23 February 2022
Resolution: MI inspected new 60amp breaker installed, labelling corrected on switchboard, wire max ampacity 64, max load 53.2amp.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 December 2021
Resolved
Approximately 80% of all life rafts were fitted with non-approved weak links. Provide approved weak links for all life rafts.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2022
Resolution: New weak links installed (Hammars) and verified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 December 2021
Resolved
The door of freeze stores reefer 01-38-2 has an inoperable door handle mechanism inside the reefer, which will result in it locking personnel inside. Repair/replace the door opening mechanism so that it may be operated from both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2022
Resolved 18 March 2022
Resolution: Inspected/tested repaired door handle; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 October 2021
Resolved
Each launching appliance for lifeboats shall be arranged that the fully equipped lifeboat can be safely launched when boarded with not more than the required operating crew on board. Vessel reported lifeboat #3 launching appliances failed to launch boat during testing. Inspection shall be made by an approved ABS/OEM lifesaving servicing technician. Provide date of scheduled inspection and technician report with root cause analysis to Sector San Diego. Total persons authorized on board reduced to 2,312.
Action required: 705 - Other - as specified
Resolved 13 January 2022
Resolution: Witnessed satisfactory davit test and received tech report which is retained in the San Diego OCMI electronic files.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2021
Resolved
Operational readiness. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Received notification from ABS Class of life boat davit failure.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2021
Resolved 2 June 2021
Resolution: Witnessed successful davit brake test on 02 June 2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 April 2021
Resolved
HP Turbine experienced a fire during its voyage. Damage was minimal to HP turbine unit. Machinery was placed back on line with no limitations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 5 May 2021
Resolution: Received ABS Survey report #4757817 of rectified repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 March 2021
Resolved
SA6 watertight door spring failed internally. Complete permanent repairs to the SA6 watertight door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 5 April 2021
Resolution: Crew completed repairs to the watertight door. ABS accepted and cleared the deficiency as a condition. A Youtube video was sent as evidence of the door's proper operation after repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2020
Resolved
It was reported that the vessel's port boiler has a leaking boiler tube. Firing the affected boiler is prohibited until repairs have been completed. The boiler shall be opened for a fireside inspection of the affected boiler, under suitable hydrostatic pressure, to determine the location of the leak (this may require the removal of lagging and/or refractory to locate the origin of the leak). The vessel shall arrange for a Marine Chemist to certify the affected boiler as "safe for workers" prior to USCG attendance - this certificate shall be maintained throughout the repair process. Vessel shall make permanent repairs to leaking boiler tube(s) where identified (plan approval may be required in accordance with 46CFR59.01-5). Upon completion of the repairs, provisions shall be made to conduct Hydrostatic test of the repaired boiler at 1.5 MAWP in accordance with 46CFR61.05 with a Coast Guard Marine Inspector in attendance.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Repairs made to leaking tubes, NDT and hydrostatic test complete at 1.25 MAWP. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2020
Resolved
While conducting hydrostatic test of the repaired port boiler superheater tubes, additional leaks were observed in-way-of the water wall header. Identify exact location and submit repair proposal for leak(s) in-way-of water wall header. The vessel shall arrange for a Marine Chemist to certify the affected boiler as "safe for workers" prior to USCG attendance - this certificate shall be maintained throughout the repair process. Vessel shall make permanent repairs to leaking boiler tube(s) where identified. Upon completion of the repairs, provisions shall be made to conduct Hydrostatic test of the repaired boiler at 1.25 MAWP in accordance with 46CFR61.05 with a Coast Guard Marine Inspector in attendance. Firing the affected boiler is prohibited until repairs have been completed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 June 2020
Resolution: Repairs completed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 December 2019
Resolved
Make permanent repairs to holed spool piece on sea-chest piping for the #3 and #4 evaporators.
Action required: 705 - Other - as specified
Due 2 January 2020
Resolved 3 February 2020
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 September 2019
Resolved
The brakes must be capable of stopping the descent of the survival craft and holding the survival craft loaded with its full complement of persons and equipment. The brake on lifeboat/tender #1 did not hold the survival craft while conducting drills. Make repairs to brake to hold "A" and "B" weight with Coast Guard in attendance.
Reduction of passenger by 150 on starboard side. Total persons allowed 2290.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 9 October 2019
Resolution: Witnessed satisfactory static and dynamic lifeboat weight test including three satisfactory brake tests under load.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 September 2019
Resolved
Each lifeboat must be plainly marked with the number of persons for which the boat is equipped and must be clearly marked in permanent characters. Lifeboat/Tender #1 did not have making showing number of persons. Mark lifeboat/tender with appropriate persons for which the boat is equipped.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 24 October 2019
Resolution: Received photos of lifeboat/tennder Max Cap.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2019
Resolved
Each lifejacket must have a lifejacket light that is approved, operational and not expired. Numerous lifejacket lights where found to be expired. Verify all 2576 lifejackets have lights that are not expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 9 October 2019
Resolution: Crew replaced 20 lifejacket lights.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 8 May 2019
Resolved
Replace embarkation ladders at lifeboat station #3 and liferaft station #9. Due 17Jun2019. Extended to 01Jul2019, parts on order.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: Ladders replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 March 2019
Resolved
Passenger and crew spaces shall have sufficient illumination provided by the emergency lighting source under emergency conditions to provide for safe egress from each space. Emergency lighting located in the enlisted male and female berthing spaces (A through H) does not allow for safe egress under emergency conditions. Ship is to install sufficient emergency lighting in berthing spaces to allow for safe egress prior to billeting persons in the spaces identified.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 22 March 2019
Resolution: All red tubes were removed from all berthing lights. All berthing's have adequate lighting for egress
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 January 2019
Resolved
Repair rescue boats door seals. Due 17Jun2019.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Replaced gaskets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 January 2019
Resolved
Replace port side tender floating water light. Due 17Jun2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Replaced water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 November 2018
Resolved
Demonstrate the proper operation of all teh open lifeboats by launching, manuevering and recovering them to/from the water prior to departure and NLT 01MAY2018.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 4 December 2018
Resolution: All open boats launched, motor, recovered - SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 October 2018
Resolved
Prove proper operation of E/R bilge suction valve (GW-54)
Condition: Improper Installation
Due 7 November 2018
Resolved 9 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2018
Resolution: Verified in VIVS.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 August 2018
Resolved
Identify deficiency with emergency generator and complete repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 August 2018
Resolution: Faulty voltage regulator replaced, EDG tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2018
Resolved
Make proper repairs, hydrotest and demonstrate proper operation to the port side propulsion boiler super heater tube leaks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2018
Resolved 13 August 2018
Resolution: Port boiler superheater tuber plugged/welded, hydro-tested to 1375 SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 July 2018
Resolved
Make proper repairs to the #1 port side life boat davit and demonstrate proper operation. Max passenger count reduced by 150 persons to 2290
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2018
Resolved 28 February 2019
Resolution: Davit servised by manufacturer, tested sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 June 2018
Resolved
Provide repair proposal for approval to repair ballast piping system, to include the isolation and check valve, in the AMR space as original. Repair proposal shall include all materials used to include welding materials, weld procedure, and proposed method of testing after repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Verified repairs per ABS drawing, witnessed with ABS surveyor operation by recirc of ballast pump. No leaks noted
Lifesaving › Lifeboat › Propulsion Transmission
Issued 3 April 2018
Resolved
Properly repair lifeboat #1 port motor transmission yo the satisfaction of attending marine inspector or classification society. Vessel will be limited to 2290 total persons until the lifeboat can be repaired. SOLAS (60 CONS) Reg. 4(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2018
Resolved 10 July 2018
Resolution: Corrected by SECTOR HONO.
Fire Fighting › Fire Main › Condition
Issued 5 March 2018
Resolved
A dime sized hole was discovered in the firemain overboard discharge pipe. Provide repair proposal for approval to repair fire main discharge pipe as original. Repair proposal shall include all materials used to include welding materials, weld procedure, and proposed method of testing after repair. Ref: 46 CFR 71.55-1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2018
Resolved 6 March 2018
Resolution: Marine Inspectors received repair proposal to repair fire main discharge pipe and witnessed leak test.
Engineering › Steam Boiler (propulsion) › Superheater
Issued 15 November 2017
Resolved
Repair burnt/damaged lagging on the steam piping on teh port ship's boiler next to the superheater safety valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 15 November 2017
Resolution: Repaired burnt/damaged lagging on the steam piping on teh port ship's boiler next to the superheater safety valve.
Engineering › Steam Boiler (propulsion) › Valve, Drum Safety
Issued 26 September 2017
Resolved
Demonstrate proper operation of the boiler safety valves prior to boiler operations/sailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 29 September 2017
Resolution: Demonstrated proper operation of the boiler safety valves prior to boiler operations/sailing.
Engineering › Steam Boiler (propulsion) › Superheater
Issued 26 September 2017
Resolved
Demonstrate proper operation of the stbd propulsion boiler super heater control valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 19 October 2017
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 22 August 2017
Resolved
Prove proper operation of SSTG reverse power relay.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 22 August 2017
Resolution: Tested RPR using PSTP.
Lifesaving › Launching Appliances › Davit
Issued 15 August 2017
Resolved
Demonstrate proper operation of the boat davit limit switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 17 August 2017
Resolution: Demonstrated proper operation of the boat davits.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 15 August 2017
Resolved
Vessel is required to have 02 operational rescue boats. Prove proper operation of the starboard side rescue boat to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2017
Resolution: Throttle controls repaired, boat tested Sat.
Construction/Loadline › Hull › Transverse Frame
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized structural beam modifications in engine room at frame 120.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 13 March 2017
Engineering › Bilge Water Management System › Piping
Issued 26 January 2017
Resolved
Demonstrate proper operation of installed bilge system and provide plans for approval and make required repairs as needed for unauthorized modifications.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 26 November 2018
Resolution: Plans provided/approved as verified by Class.
Construction/Loadline › Hull › Weld
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized installations in service area 6 to include but not limited to ladder modification and spare parts & metal shelving, spare parts hung on the aft bulkhead and equipment installs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 15 October 2018
Resolution: Verified ABS approved drawings for all ladder mods, equipment installed, and metal shelving for the spare equipment. Also verified all unauthorized installations call-out by Sector Sand Diego.
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications of various remote operational controls & MOVs as required by Class.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 3 October 2018
Resolution: Verified and tested properly installed MOVs, as required by class (ABS).
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized engine room lighting installations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 1 October 2018
Resolution: Removed unauthorized lighting in the engine room and service area No. 6.
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized installations of machine shop in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 19 October 2018
Resolution: Verified all machinery foundations, MMR door, and ventilation are in compliance with ABS outstanding OSRs.
Engineering › Steam Boiler (propulsion) › Soot Blower
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized boiler modifications IWO shoot blower drains, periscopes, sight glass level indicator lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 8 January 2019
Resolution: Inspected installation and operation of equipment, all sat.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized overhead crane installation in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 5 April 2017
Resolution: Removed crane from the engine room.
Electrical › Electric Supply System (service) › Cable
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized hot water heater installations in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 19 October 2018
Resolution: Verified proper repairs as per ABS OSR.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications to the navy laundry deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 5 April 2017
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications to oily waste piping manifold.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 23 October 2018
Resolution: Verifed/tested system per approved ABS drawing in conjunction with ABS OSR # 739/740. See drawings:
Dwg. No. 529-8497822, Rev. B, Bilge Ballast Removal, Approved as indicated in ABS Houston
letter dated 20 April 2018, Ref. T1730646
Dwg. No. 593-8497829
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications to drain installations into MSD/CHTs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 26 April 2017
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 26 January 2017
Resolved
Open and make the main turbine shaft ready for inspection due to unauthorized welding.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 15 August 2017
Engineering › Lubricating Oil Service System › Purifier
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized ADG LOP removal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 3 October 2018
Resolution: Verified all remaining piping was properly blanked, and is in compliance with ABS approved drawings.
Fire Fighting › Fire Pumps › Suction Valve
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized installation of the #1 fire pump discharge valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 4 March 2019
Resolution: Verified installation, ops tested sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 26 January 2017
Resolved
Provide proper linkage to the engine room supply fan remote dampener.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 21 March 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 26 January 2017
Resolved
Remove or provide access control to the P&S Settler Tank hatches on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 March 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2017
Resolved
Provide plans for approval and make required repairs as needed for unauthorized electrical installations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 15 October 2018
Resolution: Verified proper repairs to all electrical installations called out by ABS via OSR.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 January 2017
Resolved
Make needed updates and submit the Fire Control Plan for approval
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 17 October 2018
Resolution: Verified Revision "V"; all sat.
Engineering › Fuel Oil Service System › Settler Tank
Issued 26 January 2017
Resolved
Provide high and low level alarms for the Settler FOTs
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 26 April 2017
Engineering › Steam Boiler (propulsion) › Feed pipe
Issued 26 January 2017
Resolved
Provide proper fastener install for the aft main feed water pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 13 March 2017
Lifesaving › Launching Appliances › Davit
Issued 26 January 2017
Resolved
Service/provide proper materials to make lifeboat controls water tight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 13 March 2017
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 26 January 2017
Resolved
Provide monthly test procedures for the engine room water mist system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 21 March 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 January 2017
Resolved
Provide proper install for open electrical junction box in engine port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 13 March 2017