MAURY USCG vessel records Sign in
← All vessels

USNS MERCY

USNS MERCY is a 1976 public vessel, unclassified. The Coast Guard has recorded 282 inspections since 1986, most recently in August 2025, along with 513 deficiencies — 3 with no resolution recorded — and 9 casualty investigations between 2005 and 2024.

Records from 1986 to 2025. Most recent: inspection, 12 August 2025.

Built
1976
Last inspected
12 August 2025
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7390454 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-54331

Inspections, by type

…with no type recorded69
…past their stated due date2
Years with a record 38 calendar years (1986–2025)
The 282 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)861.8 ft × 105.8 ft × 57.9 ft
Registered tonnagegross 54,367 / net 35,958
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 63,527 / net 19,058
BuilderNASSCO,SAN DIEGO, CA · SAN DIEGO, CA, UNITED STATES · built 1976
Hull materialSteel
PropulsionSteam Turbine
Hull shapeShip
Hull configurationMonohull
Hailing portNot recorded
Trade endorsementsRegistry
DocumentationInvalid
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63527 - Convention (Subpart B), Gross Ton
54367 - Regulatory (Subpart C or D), Gross Ton
45481 - Dead Weight, Ton
19058 - Convention (Subpart B), Net Ton
35958 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 282

12 August 2025 In-Service Inspection · Administrative Inspection · Vessel Attendance
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8209406
6 March 2025 Administrative Inspection · Annual Inspection · Permit to Proceed
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8093508
2 August 2024 Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7973099
1 August 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7977176
26 July 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7967864
26 May 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7924799
1 February 2024 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7858942
10 January 2024 Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7848589
7 January 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7847448
28 December 2023 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7843285
3 November 2023 Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7820235
30 September 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7806816
20 September 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7798707
21 June 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7754832
15 June 2023 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7716507
17 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7636060
4 May 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7771519
7 February 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7642696
28 September 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7568118
21 September 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7563944
28 June 2022 Examination of Repairs · Damage Survey · Administrative Inspection · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7489314
24 June 2022 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7540235
15 April 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7431942
14 April 2022 Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439373
25 March 2022 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7418758
2 December 2021 In-Service Inspection · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7378510
3 November 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7348028
20 October 2021 Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7336272
13 October 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7335265
30 July 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7275471
30 April 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7186337
29 April 2021 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7214472
30 March 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7165805
7 July 2020 MTSA/ISPS Verification · Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6992833
6 July 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7003131
29 June 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7021147
18 May 2020 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6955496
18 May 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6959103
2 April 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6945758
19 March 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928751
3 March 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6923254
11 February 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6920685
3 February 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6901609
2 January 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6881626
17 December 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6875192
9 December 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6870012
25 October 2019 Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6841920
20 September 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6816663
20 June 2019 Administrative Inspection · Plan Review (Other than "T")
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6754469
28 May 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6775755
9 January 2019 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6608010
6 December 2018 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6592972
20 November 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6584239
16 November 2018 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6582277
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6537809
4 September 2018 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6545549
21 August 2018 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6519064
17 August 2018 Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6515023
26 July 2018 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6491689
29 June 2018 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6459913
13 April 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6409714
12 April 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685314
3 April 2018 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6383865
5 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6367287
24 January 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6343278
15 November 2017 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6307632
26 September 2017 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6275580
17 August 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6256897
15 August 2017 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6241904
26 January 2017 MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6078096
18 November 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323377
1 November 2016 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6033114
14 October 2016 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6022707
6 May 2016 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6044099
10 March 2016 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6068060
19 October 2015 Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5766998
30 October 2014 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5015858
24 October 2014 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5011668
1 October 2014 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4996752
28 August 2014 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4968066
11 August 2014 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4951708
26 June 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4901154
12 June 2014 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4887075
28 May 2014 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4872220
5 March 2014 Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4784306
29 June 2012 Plan Review (Other than "T")
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4360893
8 May 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4312862
17 February 2012 Type not recorded
No type recorded · Vintage Vessel National Center of Expertise · Activity 4427246
4 January 2012 Deficiency Check · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4218373
16 August 2011 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4117741
17 February 2011 Deficiency Check · ISM Oversight · Damage Survey · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3947642
7 January 2010 Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3662588
26 September 2008 MARPOL Annex IV Survey · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3332329
20 September 2007 Annual Inspection · MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3091912
30 July 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2998573
19 June 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2967397
19 April 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2911217
2 October 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2718321
3 March 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2595488
23 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2590695
9 February 2006 Administrative Inspection · In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2628721
21 November 2005 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2563728
18 November 2005 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2531724
26 September 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2512201
8 August 2005 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2455817
18 July 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2431442
5 July 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2390125
20 June 2005 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2396926
4 May 2005 Drydock Extension
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2343811
12 February 2005 In-Service Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2291169
2 January 2005 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2267540
21 September 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2169694
1 September 2004 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2183376
30 August 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2181329
22 July 2004 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2142066
20 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2104696
29 March 2004 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2033311
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1997435
16 September 2003 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1906168
22 July 2003 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1854298
3 July 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1834077
17 October 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1691719
12 September 2002 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1674946
23 July 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1651087
12 June 2002 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1629892
19 October 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1073946
13 August 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370327
30 March 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382231
6 March 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1060620
11 January 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418837
24 October 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418838
16 September 2000 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418836
9 August 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1464308
20 June 2000 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379161
28 April 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 820448
27 March 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1427786
8 January 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 815272
9 December 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386647
18 November 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 810698
18 November 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393277
30 September 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1198233
27 August 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372778
5 May 1999 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391009
20 April 1999 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1123790
9 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 778164
26 August 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1464787
2 April 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409872
2 February 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1122447
18 December 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 781384
8 October 1997 Deficiency Check · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378199
6 August 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375080
19 June 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1112263
9 June 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 774959
10 April 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1091363
14 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103437
30 September 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1145842
6 September 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 835430
23 August 1996 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1359244
24 July 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 73377
23 May 1996 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1425743
2 May 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1080196
11 April 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083998
27 February 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1081319
9 February 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1385639
29 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 49470
23 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 99040
5 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1371260
30 November 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1192710
30 November 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1463431
7 October 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 103078
14 June 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1188652
2 June 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 873459
8 May 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1349453
27 March 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139362
24 March 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831470
2 February 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142264
3 January 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163381
20 December 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1154153
15 December 1994 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142634
14 December 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 840691
12 December 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146160
8 December 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834088
7 December 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834809
17 November 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 860528
15 November 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866422
15 November 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140357
8 November 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1180898
2 November 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 863142
11 October 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1177517
15 September 1994 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181294
14 September 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140356
29 August 1994 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1424008
7 July 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140358
20 June 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328591
10 June 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1016298
10 May 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1327753
11 April 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1171204
16 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165858
10 February 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851787
24 November 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848127
5 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 849245
29 October 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146300
21 October 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1457127
7 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 826766
9 September 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838294
12 August 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 847901
10 August 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160169
3 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842644
2 August 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1161553
26 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2679
23 July 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 844415
7 July 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153636
24 June 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834504
12 May 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146929
3 May 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148456
29 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1382557
14 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 836087
30 March 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144085
15 March 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 841667
1 March 1993 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838464
24 February 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837541
10 February 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 834882
2 February 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 188349
14 December 1992 Deficiency Check · Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1356187
3 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1133404
21 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948251
19 October 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 961408
23 September 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1270218
10 September 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1252971
27 August 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263803
26 August 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263322
4 August 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 944659
21 July 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952802
26 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1258094
21 May 1992 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264324
3 May 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 172330
9 April 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1270618
24 February 1992 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1316979
10 February 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263537
17 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 61501
22 October 1991 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312487
21 August 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942647
17 July 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 936871
23 June 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 902314
6 June 1991 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 902313
30 April 1991 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240617
11 April 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1244333
10 April 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 930375
27 March 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926090
1 March 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927459
16 December 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913099
23 November 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1217639
14 August 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921231
1 August 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 904182
13 July 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240130
2 April 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 979587
26 March 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229176
21 March 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1214918
2 January 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1231084
13 December 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1235600
30 October 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1209767
1 May 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1004593
25 November 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1207232
27 October 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 888671
27 October 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 888673
2 September 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040665
12 August 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344451
11 August 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1347663
10 August 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1343022
9 August 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343812
9 August 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1343815
11 July 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 897397
8 July 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1208820
11 May 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1347434
8 April 1988 Deficiency Check · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 890900
17 January 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1013870
3 November 1987 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1328953
7 August 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1337176
4 July 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1021236
18 December 1986 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1332845
18 April 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989309
29 January 1986 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1318531

Deficiency record · 513

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 February 2026 No resolution recorded
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Vessels #7 lifeboat lowering wire parted during routine maintenance and the #9 lifeboat davit will not lower. Vessels total passenger count is reduced by 240 passengers making the total passenger count allowed until repairs are made 2,200 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 February 2026 No resolution recorded
On Monday, February 9, 2026, Sector Mobile was notified of leaking sewage pipe inside of the 4C ballast tank, which caused the sewage tank to fill up when the 4C ballast tank was filled to over 91% full. The suspect pipe was determined to be located in the shower drain in 4-62-2. The company is making preparations to attend dry dock in March 2026 and requested a temporary repair which was approved by ABS with Sector Mobile concurrence. Vessel must complete temporary repair proposal and monitoring plan submitted on 09FEB26. Permanent repairs shall be made prior to completion of next dry dock due 31MAR2026. 46 CFR 72.01-15(a)
Action required: 705 - Other - as specified
Due 31 March 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 6 March 2025 No resolution recorded
Vessel has severe damage between the 4C ballast tank and anti-roll tank that has been temporarily repaired to the satisfaction of the USCG. Complete permanent repairs during the 2025 dry docking. Vessel must acquire a permit-to-proceed prior to departing the San Diego inspection zone to complete repairs. Cite: 46 CFR 92.01-10
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2025 Resolved
Starboard tender's powered bilge pumps are not operational. Conduct repairs of the affected pumps and demonstrate satisfactory operation for attending USCG marine inspector. The starboard tender may not conduct tendering operations until this deficiency is rectified. Cite: 46 CFR 182.520.
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 March 2025 Resolved
Both tenders do not have serviceable fire-buckets. Replace both tender's fire buckets in accordance with 46 CFR 181.610. Neither tender may not conduct tendering operations until this deficiency is rectified. Cite: 46 CFR 181.610.
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: New buckets were acquired.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 2 August 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 April 2025
Resolution: Temporary repairs have been completed. Another deficiency will be issued to complete permanent repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 July 2024 Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The No. 7 Liferaft Davit was found to be inoperable due to excessive wastage of the gear box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2024
Resolved 18 April 2025
Resolution: Gearbox was replaced; witnessed satisfactory davit test using "B" weight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 July 2023 Resolved
The #5 lifeboat's engine failed multiple times during in-water lifeboat testing. Identify cause of failure and repair. The #5 lifeboat may not be used to determine the vessel's total person count until this deficiency has been rectified to the satisfaction of the attending USCG marine inspector. Cite: 74 SOLAS (1997) Reg 20.1.1.1
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Witnessed satisfactory boat meaneuvering test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 June 2023 Resolved
While vessel personnel were conducting weekly testing of lifeboat engine, found the engine would not turnover. Further inspection found the engine oil sump to be full of water. Repair engine. Passenger count shall be reduced by 133 until repairs are made.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Witnessed satisfactory boat meaneuvering test.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 May 2023 Resolved
During abandon ship drills, it was discovered that the No. 1 Tender Vessel's davit was not fully operational, with electrical, hydraulic, and brake issues. The No. 1 Tender Vessel may not be used to determine the vessel's total persons count until this deficiency has been rectified to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 4 October 2023
Resolution: Brakes were replaced and overhauled. Witnessed satisfactory brake test.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2023 Resolved
Received a failed foam analysis report for the AFFF stored in the flight deck and machinery space storage tanks. Both AFFF samples did not meet the required expansion ratio requirements of 4.5%. Please submit a satisfactory foam analysis report within 30-days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 8 June 2023
Resolution: Received a satisfactory foam analysis report from National Foam for the AFFF stored in the flight deck (5.5%) and machinery space (7.9%) storage tanks; invoice No. NFAN010403.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 September 2022 Resolved
Each bus-tie between a main switchboard and an emergency switchboard must: (a) Disconnect automatically upon loss of potential at the emergency switchboard; (b) Be arranged to prevent parallel operation of an emergency power source with any other source of electric power, except for interlock systems for momentary transfer of loads. Vessel reported that its EDG Auto-Manual selector switch is malfunctioning to include its Auto mode function. During return voyage to San Diego, CA, vessel shall provide a watch stander in the EDG space (with sufficient communications equipment) to activate the EDG for any possible loss of power. If manning is insufficient to maintain this additional watch station, provide a proposal of equivalent safety. During transit within port (from sea buoy to final berth) vessel shall maintain the EDG ready on standby to take electrical load in case of loss of power. Upon safe return vessel shall make permanent repairs to EDG.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 October 2022
Resolution: Witnessed operation by Attending MI; ALL SAT
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 28 September 2022 Resolved
All emergency equipment shall be maintained in an operative condition. Vessel reported GMDSS SAT C system cannot log in or connect to any region. System will not sych with NSC or NCC. Upon return to home port vessel vessel will make permanent repairs.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 13 February 2023
Resolution: Cleared deficiency off the servicing report provided by J & L Marine Electronics. Added servicing report to the Documents Tab.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 28 September 2022 Resolved
Each fall used in a launching appliance must be renewed when necessary due to deterioration or at intervals of not more than 5 years, whichever is earlier. Both tender boat davits are past their 5 year maintenance window. Both tenders may not be utilized until appropriate maintenance of the davits has been completed. The tenders may not be used to determine the vessel's total person count until deficiency is rectified.
Action required: 15 - Rectify deficiencies by next port
Resolved 5 April 2023
Resolution: Received the Fassmer certificates of serviceability reports for the No.1 and No.2 life boat davits after this deficiency had been rectified to the satisfaction of the attending technician. Please see Fassmer Service Reports 2023-02-047327 & 047328.
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 28 September 2022 Resolved
Accommodations provided for officers and crew on all vessels shall be securely constructed, properly lighted, heated, drained, ventilated, equipped, located, arranged, and insulated from undue noise, heat, and odors. Seals on the vessel's deck drains connected to the sewage system have been reported as not being sufficiently maintained, resulting in releases of hydrogen sulfide and VOCs to accommodation spaces. Complete adequate maintenance of deck drain seals to prevent further sewage vapor releases.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2023
Resolved 17 May 2023
Resolution: Deck seal drain maintenance was completed and the traps were refilled with water to address this concern of vapor release through the floor drains. This item will require regular maintenance going forward by the vessel's crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 January 2022 Resolved
Fire door F.S.D. 70 gets caught on a nearby escape scuttle during closure. Adjust F.S.D. 70 as necessary to prevent it from getting caught.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 9 February 2022
Resolution: Fire door has been properly adjusted. Witnessed satisfactory door closing test.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 January 2022 Resolved
02 open cable transits were discovered in stair tower 4-68-2. Properly re-pack both cable transits with approved materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 9 February 2022
Resolution: Cable transits were properly repacked and inspected.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 January 2022 Resolved
02 open cable transits were discovered in the bulkheads about fire doors F.S.D. 87 and F.S.D. 82. Properly re-pack both cable transits with approved materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 9 February 2022
Resolution: Cable transits were properly repacked and inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 January 2022 Resolved
The #9 lifeboat stalls during operation and has difficulty starting. Diagnose and repair the cause of the failure and conduct a satisfactory operational test in the presence of a USCG marine inspector. Total persons authorized on board reduced to 2,184.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 March 2022
Resolution: Witnessed satisfactory test of the lifeboat in the water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2021 Resolved
The emergency switchboard was found with a 100 amp breaker installed for the keep warm emergency generator heater. The circuit conductor size is rated for 64 amps. Tag-out current circuit breaker, provide keep warm heater with adequate over current protection and update ship's drawings.
Action required: 705 - Other - as specified
Due 25 April 2022
Resolved 23 February 2022
Resolution: MI inspected new 60amp breaker installed, labelling corrected on switchboard, wire max ampacity 64, max load 53.2amp.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 December 2021 Resolved
Approximately 80% of all life rafts were fitted with non-approved weak links. Provide approved weak links for all life rafts.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 March 2022
Resolution: New weak links installed (Hammars) and verified.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 December 2021 Resolved
The door of freeze stores reefer 01-38-2 has an inoperable door handle mechanism inside the reefer, which will result in it locking personnel inside. Repair/replace the door opening mechanism so that it may be operated from both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2022
Resolved 18 March 2022
Resolution: Inspected/tested repaired door handle; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 October 2021 Resolved
Each launching appliance for lifeboats shall be arranged that the fully equipped lifeboat can be safely launched when boarded with not more than the required operating crew on board. Vessel reported lifeboat #3 launching appliances failed to launch boat during testing. Inspection shall be made by an approved ABS/OEM lifesaving servicing technician. Provide date of scheduled inspection and technician report with root cause analysis to Sector San Diego. Total persons authorized on board reduced to 2,312.
Action required: 705 - Other - as specified
Resolved 13 January 2022
Resolution: Witnessed satisfactory davit test and received tech report which is retained in the San Diego OCMI electronic files.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2021 Resolved
Operational readiness. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Received notification from ABS Class of life boat davit failure.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2021
Resolved 2 June 2021
Resolution: Witnessed successful davit brake test on 02 June 2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 April 2021 Resolved
HP Turbine experienced a fire during its voyage. Damage was minimal to HP turbine unit. Machinery was placed back on line with no limitations.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2021
Resolved 5 May 2021
Resolution: Received ABS Survey report #4757817 of rectified repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 March 2021 Resolved
SA6 watertight door spring failed internally. Complete permanent repairs to the SA6 watertight door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 5 April 2021
Resolution: Crew completed repairs to the watertight door. ABS accepted and cleared the deficiency as a condition. A Youtube video was sent as evidence of the door's proper operation after repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2020 Resolved
It was reported that the vessel's port boiler has a leaking boiler tube. Firing the affected boiler is prohibited until repairs have been completed. The boiler shall be opened for a fireside inspection of the affected boiler, under suitable hydrostatic pressure, to determine the location of the leak (this may require the removal of lagging and/or refractory to locate the origin of the leak). The vessel shall arrange for a Marine Chemist to certify the affected boiler as "safe for workers" prior to USCG attendance - this certificate shall be maintained throughout the repair process. Vessel shall make permanent repairs to leaking boiler tube(s) where identified (plan approval may be required in accordance with 46CFR59.01-5). Upon completion of the repairs, provisions shall be made to conduct Hydrostatic test of the repaired boiler at 1.5 MAWP in accordance with 46CFR61.05 with a Coast Guard Marine Inspector in attendance.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Repairs made to leaking tubes, NDT and hydrostatic test complete at 1.25 MAWP. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2020 Resolved
While conducting hydrostatic test of the repaired port boiler superheater tubes, additional leaks were observed in-way-of the water wall header. Identify exact location and submit repair proposal for leak(s) in-way-of water wall header. The vessel shall arrange for a Marine Chemist to certify the affected boiler as "safe for workers" prior to USCG attendance - this certificate shall be maintained throughout the repair process. Vessel shall make permanent repairs to leaking boiler tube(s) where identified. Upon completion of the repairs, provisions shall be made to conduct Hydrostatic test of the repaired boiler at 1.25 MAWP in accordance with 46CFR61.05 with a Coast Guard Marine Inspector in attendance. Firing the affected boiler is prohibited until repairs have been completed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 June 2020
Resolution: Repairs completed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 December 2019 Resolved
Make permanent repairs to holed spool piece on sea-chest piping for the #3 and #4 evaporators.
Action required: 705 - Other - as specified
Due 2 January 2020
Resolved 3 February 2020
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 September 2019 Resolved
The brakes must be capable of stopping the descent of the survival craft and holding the survival craft loaded with its full complement of persons and equipment. The brake on lifeboat/tender #1 did not hold the survival craft while conducting drills. Make repairs to brake to hold "A" and "B" weight with Coast Guard in attendance. Reduction of passenger by 150 on starboard side. Total persons allowed 2290.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 9 October 2019
Resolution: Witnessed satisfactory static and dynamic lifeboat weight test including three satisfactory brake tests under load.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 September 2019 Resolved
Each lifeboat must be plainly marked with the number of persons for which the boat is equipped and must be clearly marked in permanent characters. Lifeboat/Tender #1 did not have making showing number of persons. Mark lifeboat/tender with appropriate persons for which the boat is equipped.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 24 October 2019
Resolution: Received photos of lifeboat/tennder Max Cap.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2019 Resolved
Each lifejacket must have a lifejacket light that is approved, operational and not expired. Numerous lifejacket lights where found to be expired. Verify all 2576 lifejackets have lights that are not expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2019
Resolved 9 October 2019
Resolution: Crew replaced 20 lifejacket lights.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 8 May 2019 Resolved
Replace embarkation ladders at lifeboat station #3 and liferaft station #9. Due 17Jun2019. Extended to 01Jul2019, parts on order.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: Ladders replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 March 2019 Resolved
Passenger and crew spaces shall have sufficient illumination provided by the emergency lighting source under emergency conditions to provide for safe egress from each space. Emergency lighting located in the enlisted male and female berthing spaces (A through H) does not allow for safe egress under emergency conditions. Ship is to install sufficient emergency lighting in berthing spaces to allow for safe egress prior to billeting persons in the spaces identified.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 22 March 2019
Resolution: All red tubes were removed from all berthing lights. All berthing's have adequate lighting for egress
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 January 2019 Resolved
Repair rescue boats door seals. Due 17Jun2019.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Replaced gaskets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 January 2019 Resolved
Replace port side tender floating water light. Due 17Jun2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 June 2019
Resolution: Replaced water light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 November 2018 Resolved
Demonstrate the proper operation of all teh open lifeboats by launching, manuevering and recovering them to/from the water prior to departure and NLT 01MAY2018.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 4 December 2018
Resolution: All open boats launched, motor, recovered - SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 October 2018 Resolved
Prove proper operation of E/R bilge suction valve (GW-54)
Condition: Improper Installation
Due 7 November 2018
Resolved 9 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, NAME: Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 October 2018
Resolution: Verified in VIVS.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 August 2018 Resolved
Identify deficiency with emergency generator and complete repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 August 2018
Resolution: Faulty voltage regulator replaced, EDG tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2018 Resolved
Make proper repairs, hydrotest and demonstrate proper operation to the port side propulsion boiler super heater tube leaks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2018
Resolved 13 August 2018
Resolution: Port boiler superheater tuber plugged/welded, hydro-tested to 1375 SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 July 2018 Resolved
Make proper repairs to the #1 port side life boat davit and demonstrate proper operation. Max passenger count reduced by 150 persons to 2290
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2018
Resolved 28 February 2019
Resolution: Davit servised by manufacturer, tested sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 June 2018 Resolved
Provide repair proposal for approval to repair ballast piping system, to include the isolation and check valve, in the AMR space as original. Repair proposal shall include all materials used to include welding materials, weld procedure, and proposed method of testing after repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Verified repairs per ABS drawing, witnessed with ABS surveyor operation by recirc of ballast pump. No leaks noted
Lifesaving › Lifeboat › Propulsion Transmission
Issued 3 April 2018 Resolved
Properly repair lifeboat #1 port motor transmission yo the satisfaction of attending marine inspector or classification society. Vessel will be limited to 2290 total persons until the lifeboat can be repaired. SOLAS (60 CONS) Reg. 4(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2018
Resolved 10 July 2018
Resolution: Corrected by SECTOR HONO.
Fire Fighting › Fire Main › Condition
Issued 5 March 2018 Resolved
A dime sized hole was discovered in the firemain overboard discharge pipe. Provide repair proposal for approval to repair fire main discharge pipe as original. Repair proposal shall include all materials used to include welding materials, weld procedure, and proposed method of testing after repair. Ref: 46 CFR 71.55-1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2018
Resolved 6 March 2018
Resolution: Marine Inspectors received repair proposal to repair fire main discharge pipe and witnessed leak test.
Engineering › Steam Boiler (propulsion) › Superheater
Issued 15 November 2017 Resolved
Repair burnt/damaged lagging on the steam piping on teh port ship's boiler next to the superheater safety valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 15 November 2017
Resolution: Repaired burnt/damaged lagging on the steam piping on teh port ship's boiler next to the superheater safety valve.
Engineering › Steam Boiler (propulsion) › Valve, Drum Safety
Issued 26 September 2017 Resolved
Demonstrate proper operation of the boiler safety valves prior to boiler operations/sailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 29 September 2017
Resolution: Demonstrated proper operation of the boiler safety valves prior to boiler operations/sailing.
Engineering › Steam Boiler (propulsion) › Superheater
Issued 26 September 2017 Resolved
Demonstrate proper operation of the stbd propulsion boiler super heater control valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 19 October 2017
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 22 August 2017 Resolved
Prove proper operation of SSTG reverse power relay.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2017
Resolved 22 August 2017
Resolution: Tested RPR using PSTP.
Lifesaving › Launching Appliances › Davit
Issued 15 August 2017 Resolved
Demonstrate proper operation of the boat davit limit switch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 17 August 2017
Resolution: Demonstrated proper operation of the boat davits.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 15 August 2017 Resolved
Vessel is required to have 02 operational rescue boats. Prove proper operation of the starboard side rescue boat to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2017
Resolution: Throttle controls repaired, boat tested Sat.
Construction/Loadline › Hull › Transverse Frame
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized structural beam modifications in engine room at frame 120.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 13 March 2017
Engineering › Bilge Water Management System › Piping
Issued 26 January 2017 Resolved
Demonstrate proper operation of installed bilge system and provide plans for approval and make required repairs as needed for unauthorized modifications.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 26 November 2018
Resolution: Plans provided/approved as verified by Class.
Construction/Loadline › Hull › Weld
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized installations in service area 6 to include but not limited to ladder modification and spare parts & metal shelving, spare parts hung on the aft bulkhead and equipment installs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 15 October 2018
Resolution: Verified ABS approved drawings for all ladder mods, equipment installed, and metal shelving for the spare equipment. Also verified all unauthorized installations call-out by Sector Sand Diego.
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications of various remote operational controls & MOVs as required by Class.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 3 October 2018
Resolution: Verified and tested properly installed MOVs, as required by class (ABS).
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized engine room lighting installations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 1 October 2018
Resolution: Removed unauthorized lighting in the engine room and service area No. 6.
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized installations of machine shop in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 19 October 2018
Resolution: Verified all machinery foundations, MMR door, and ventilation are in compliance with ABS outstanding OSRs.
Engineering › Steam Boiler (propulsion) › Soot Blower
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized boiler modifications IWO shoot blower drains, periscopes, sight glass level indicator lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 8 January 2019
Resolution: Inspected installation and operation of equipment, all sat.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized overhead crane installation in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 5 April 2017
Resolution: Removed crane from the engine room.
Electrical › Electric Supply System (service) › Cable
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized hot water heater installations in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 19 October 2018
Resolution: Verified proper repairs as per ABS OSR.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications to the navy laundry deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 5 April 2017
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications to oily waste piping manifold.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 23 October 2018
Resolution: Verifed/tested system per approved ABS drawing in conjunction with ABS OSR # 739/740. See drawings: Dwg. No. 529-8497822, Rev. B, Bilge Ballast Removal, Approved as indicated in ABS Houston letter dated 20 April 2018, Ref. T1730646 Dwg. No. 593-8497829
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized modifications to drain installations into MSD/CHTs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 26 April 2017
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 26 January 2017 Resolved
Open and make the main turbine shaft ready for inspection due to unauthorized welding.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 15 August 2017
Engineering › Lubricating Oil Service System › Purifier
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized ADG LOP removal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 3 October 2018
Resolution: Verified all remaining piping was properly blanked, and is in compliance with ABS approved drawings.
Fire Fighting › Fire Pumps › Suction Valve
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized installation of the #1 fire pump discharge valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 4 March 2019
Resolution: Verified installation, ops tested sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 26 January 2017 Resolved
Provide proper linkage to the engine room supply fan remote dampener.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 21 March 2017
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 26 January 2017 Resolved
Remove or provide access control to the P&S Settler Tank hatches on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 March 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2017 Resolved
Provide plans for approval and make required repairs as needed for unauthorized electrical installations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 15 October 2018
Resolution: Verified proper repairs to all electrical installations called out by ABS via OSR.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 January 2017 Resolved
Make needed updates and submit the Fire Control Plan for approval
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 17 October 2018
Resolution: Verified Revision "V"; all sat.
Engineering › Fuel Oil Service System › Settler Tank
Issued 26 January 2017 Resolved
Provide high and low level alarms for the Settler FOTs
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 26 April 2017
Engineering › Steam Boiler (propulsion) › Feed pipe
Issued 26 January 2017 Resolved
Provide proper fastener install for the aft main feed water pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 13 March 2017
Lifesaving › Launching Appliances › Davit
Issued 26 January 2017 Resolved
Service/provide proper materials to make lifeboat controls water tight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 13 March 2017
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 26 January 2017 Resolved
Provide monthly test procedures for the engine room water mist system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 21 March 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 January 2017 Resolved
Provide proper install for open electrical junction box in engine port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 13 March 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 February 2016 Resolved
ECC fixed firefighting (CO2) time delay inop. Replace with new time delay to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 26 March 2016
Resolved 10 March 2016
Resolution: A new time delay was installed and tested SAT.
Deck/Cargo › Ballast › Valves
Issued 1 July 2014 Resolved
Make proper repairs to ballast system in accordance with your approved repair plan to the satisfaction of class and Coast Guard Marine Inspectors.
Due 7 November 2014
Resolved 6 November 2014
Resolution: Valves installed and tested SAT.
Deck/Cargo › Ballast › Valves
Issued 26 June 2014 Resolved
Provide a proposal for proper repairs to the starboard ballast tank to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2014
Resolution: Repair proposal approved by ABS and CG MIs.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 25 April 2012 Resolved
Provide suitable check ball for all lifeboat drains prior to deployment on May 1st.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2012
Resolved 26 April 2012
Resolution: Check balls for lifeboat drains located in lifeboat toolkits. Verified installation of check balls.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 25 April 2012 Resolved
Permanently attach all drain plugs on each lifeboat piro to deployment on May 1st.
Action required: 705 - Other - as specified
Due 1 May 2012
Resolved 26 April 2012
Resolution: Verified drain plugs for lifeboats are permanently attached.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 7 February 2012 Resolved
Provide copies of all ABS renewal certificates.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 29 March 2012
Resolution: ABS certificates received.
Engineering › Pressure Vessel › Relief Valve
Issued 4 January 2012 Resolved
Demonstrate proper operation of all UPV relief valves.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 17 February 2012
Resolution: Demontrated operation of relief valves.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 January 2012 Resolved
Demonstrate proper operation & label incinerator fire damper.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 23 February 2012
Resolution: Fire damper labeled and operated properly.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 4 January 2012 Resolved
Demonstrate proper operation of incinerator emegency stops.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2012
Resolved 23 February 2012
Resolution: Incinerator ememrgency stops tested SAT
Engineering › Diesel Engine (auxiliary) › Governor
Issued 4 January 2012 Resolved
Provide glass to emergency stops for AMR remote shutdown panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 27 February 2012
Resolution: Glass provided to emgergency stops panel.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 January 2012 Resolved
Provide proper material in electrical panel breaker opening in Engine Room switchboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 23 February 2012
Resolution: Provided non-conductive material and a proper intallation to breaker opening in panel.
Engineering › Bilge Water Management System › Valve
Issued 4 January 2012 Resolved
Demonstrate proper operation of bilge suction & ballast water valve reachrods.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 23 February 2012
Lifesaving › Launching Appliances › Davit
Issued 4 January 2012 Resolved
Demonstrate proper operation #7 & #9 Lifeboat davit limit switches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 23 February 2012
Resolution: Demonstrated proper operation of lifeboat davit switches.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 4 January 2012 Resolved
Remove combustible furnishings, materials & flammable gasses from fan spaces.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 27 February 2012
Resolution: Combustibles removed from fan spaces.
Engineering › Steam Boiler (propulsion) › Piping
Issued 4 January 2012 Resolved
Provide packing material to all valves with less than 50% packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2013
Resolved 25 April 2012
Resolution: Valve packing completed.
Fire Fighting › International Shore Connection › Washers
Issued 4 January 2012 Resolved
Provide washers for each International Shore Connection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 23 February 2012
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 January 2012 Resolved
Provide metallic piping to JP-5 system and restore to original plans.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 23 February 2012
Engineering › Steam Boiler (propulsion) › Gauge Glass
Issued 4 January 2012 Resolved
Provide protective guards to deareating tank sight glasses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 27 February 2012
Resolution: Guards provided to deareating tank sight glasses.
Engineering › Fuel Oil Service System › Settler Tank
Issued 4 January 2012 Resolved
Demonstrate proper operation of settling tanks port& stbd high/low level alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2013
Resolved 12 June 2013
Engineering › Steam Boiler (propulsion) › Steam Drum
Issued 4 January 2012 Resolved
Conduct hydrostatic test at 1.25% of MAWP (1375 PSI) on stbd boiler.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 11 February 2012
Resolution: Stbd boiler hydro tested SAT at 1375 PSI
Engineering › Steam Boiler (propulsion) › Valve, Superheater Safety
Issued 4 January 2012 Resolved
Demonstrate proper operation of Port Boiler Safety valves settings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 27 February 2012
Resolution: Demonstrated proper operation and setting of port boiler safety valves.
Engineering › Steam Boiler (propulsion) › Piping
Issued 4 January 2012 Resolved
Provide identification lables to steam chest & condensor PSI gauges.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 27 February 2012
Fire Fighting › Ventilation Systems › Operating Controls
Issued 4 January 2012 Resolved
Prove proper operation of fire dampers 01-61-6 and 01-58-3.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 25 April 2012
Resolution: Witnessed proper operation of fire dampers.
Lifesaving › Lifeboat › Propulsion Engine
Issued 4 January 2012 Resolved
Install plugs on sea suction cooling lines for all lifeboats engines and verify all hoses are double clamped.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 27 February 2012
Resolution: Verified plugs are installed and hoses are now double clamped.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 4 January 2012 Resolved
Provide exit sign marking on door 4-54-1.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 5 March 2012
Resolution: Exit sign applied to door.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 4 January 2012 Resolved
Repair bulkhead penetration due to grinder wheel in hepa filter room 01-53-6.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 29 March 2012
Resolution: Bulkhead repaired.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 4 January 2012 Resolved
Provide escape arrows and exit signs for egress from operating rooms.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 5 March 2012
Resolution: Escape arrows and exit signs installed.
Stability › Watertight Integrity › General
Issued 4 January 2012 Resolved
Adjust switch (local control) on port side of sliding watertight door to Service Area #2 to operate the door in the same direction of the switch.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 29 April 2012
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 4 January 2012 Resolved
Provide launching instructions for manual release of liferafts other than davit launched at launching station.
Action required: 705 - Other - as specified
Due 24 March 2012
Resolved 5 March 2012
Resolution: Launching instructions provided.
Construction/Loadline › Structures › Deck Plating
Issued 20 June 2011 Resolved
Make permanent repairs to [fractured] overhead shell plating and transverse frame over nitrogen plant between frames 65 & 66. To be completed to satisfaction of attending marine inspector no later than ship's first operational deployment and before operational use of #1 nitrogen plant.
Action required: 705 - Other - as specified
Resolved 5 July 2011
Resolution: Received ABS Class Report# SC2006632. All repair work was completed to the satisfaction of the attending surveyor.
Engineering › Bilge Water Management System › Piping
Issued 9 March 2011 Resolved
Remove 2" pipe segment connecting OWS recirc to emerg. bilge overboard discharge line.
Action required: 705 - Other - as specified
Resolved 25 March 2011
Engineering › Steam Boiler (propulsion) › Valve, Drum Safety
Issued 9 March 2011 Resolved
Refit stbd boiler pilot relief valve pipe segment (1") that rises from elbow joint and creates liquid hammer hazard
Action required: 705 - Other - as specified
Resolved 10 May 2011
Engineering › Bilge Water Management System › Piping
Issued 9 March 2011 Resolved
Provide placard at bilge/ballast remote controllers [for motor operated valves] to indicate that system is for emerg. use only
Action required: 705 - Other - as specified
Resolved 10 May 2011
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 March 2011 Resolved
Develop written procedure for emerg. bilge/ballast system operation.
Action required: 705 - Other - as specified
Resolved 20 June 2011
Engineering › Pressure Vessel › Relief Valve
Issued 9 March 2011 Resolved
Provide properly operating DC heater relief valve, considering MAWP & feed rates.
Action required: 705 - Other - as specified
Resolved 10 May 2011
Fire Fighting › Grease Extraction Hood › General
Issued 9 March 2011 Resolved
Repair/replace Gaylord hood #5 (main galley, service area #1); not opening properly.
Action required: 705 - Other - as specified
Resolved 20 June 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 March 2011 Resolved
Conduct and log emergency fire & boat drills IAW ship's training manual; boat drills must include lowering & release of lifeboats, as far as practicable, per MSC Circ.1136
Action required: 705 - Other - as specified
Resolved 26 September 2011
Lifesaving › Launching Appliances › Davit
Issued 9 March 2011 Resolved
Complete service to life raft davits 4, 11, 13, and lifeboat davits 3, 9 as recommended by OEM for safe operation. All lifeboats and life rafts served by these appliances shall be considered out of service until repairs are complete, OEM inspection recommends their continued use, and verified by USCG inspector. Vessel may carry a max. of 2019 total POB, a max. of 804 of which may be patients.
Action required: 705 - Other - as specified
Resolved 7 September 2011
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 March 2011 Resolved
Demonstrate proper remote-manual operation of WTD joining main machinery space & pump room flat. [On day of inspection, WTD sticking on knife edge, in need of lubrication & adjustment.
Action required: 705 - Other - as specified
Resolved 4 March 2011
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 February 2011 Resolved
Demonstrate proper operation of emerg. generator {on day of inspection, generator would auto-start but would not take load).
Action required: 705 - Other - as specified
Resolved 3 March 2011
Resolution: replaced panel auto-switch
Lifesaving › Lifeboat › Propulsion Engine
Issued 25 March 2010 Resolved
Provide proof of operation the raw water cooling pump on Life boat #5 propulsion engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2010
Resolved 29 April 2010
Resolution: Corrected
Lifesaving › Lifeboat › Canopy
Issued 13 January 2010 Resolved
Renew all deteriorated fasteners, rings and grommets on all life boat covers in order to return them to original condition.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: All deteriorated hardware renewed on canopy covers.
Lifesaving › Lifeboat › Canopy
Issued 13 January 2010 Resolved
Apply vessel's name or call sign on all lifeboat covers to make identity visible from above.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Call Sign affixed to all canopy covers with retro-reflective tape.
Lifesaving › Lifeboat Equipment › Painter
Issued 13 January 2010 Resolved
Provide for missing painter for each lifeboat. Required quantity is two per boat.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Missing painters provided for each boat.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 13 January 2010 Resolved
Provide rain collection equipment or approved Reverse Osmosis Desalinator for each boat. 46 CFR 160.058
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Rain collection equipment provided for each boat.
Lifesaving › Lifeboat Equipment › Sea-anchor
Issued 13 January 2010 Resolved
Repair or replace Sea Anchors for each Lifeboat.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Sea Anchors with attached Halyards replaced for each boat.
Lifesaving › Lifeboat › Skate
Issued 13 January 2010 Resolved
Provide for missing Skates on lifeboats. One pair required for each boat.
Action required: 705 - Other - as specified
Due 28 April 2010
Resolved 29 April 2010
Resolution: Corrected
Lifesaving › Lifeboat › Watertight Enclosure
Issued 13 January 2010 Resolved
Replace household type electrical junction box in radio compartment of lifeboats #1 & #2, with marine grade type.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Household electrical boxes removed from both boats. No longer needed due to the usage of portable radios.
Lifesaving › Immersion Suits › Quantity
Issued 13 January 2010 Resolved
Provide Immersion suits of suitable size for each rescue boat crew member.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Immersion suits provided in each boat.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 13 January 2010 Resolved
Provide and post Muster list and Emergency Instructions for crew members and non-crew members in required locations, throughout the vessel.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Muster list and Emergency instructions provided and posted throughout accommodation spaces, wards and areas, wards, passageways.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 January 2010 Resolved
Provide markings/symbols for lifesaving equipment stowage throughout the vessel. 46 CFR 199.178
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Markings and Symbols provided throughout the vessel.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 13 January 2010 Resolved
Renew and provide Operating Instructions for each Survival Craft Davit on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2010
Resolved 29 April 2010
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 13 January 2010 Resolved
Prove proper operation of Incinerator F/O tank shut off valve.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Proof of operation provided.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 13 January 2010 Resolved
Provide functional scupper plug for the Aft fuel station.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Existing plug lubricated and exercised to make functional.
Construction/Loadline › Hull › Side Shell
Issued 13 January 2010 Resolved
Renew deteriorated gaskets on Port & Stbd side port loading doors, repair port side knife edge to make as original, repair hydraulic systems for each door to stop hydraulic leakage which is causing pollution and safety hazards. Upon completion, of all repairs, prove proper operation of both doors and prove doors are water tight.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 25 March 2010
Resolution: All repairs completed and proof of operation and water tightness witnessed.
Lifesaving › Lifeboat › Markings
Issued 13 January 2010 Resolved
Provide and apply retro reflective tape to hulls of the stbd life boats on the areas missing.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Retro reflective tape applied.
Fire Fighting › Ventilation Systems › Ducts
Issued 7 January 2010 Resolved
Prove proper operation of ventilation dampers 1-145-0, 72-05-50, 76-15-35, 1-91-6, and 1-91-8.
Action required: 705 - Other - as specified
Due 28 February 2010
Resolved 28 February 2010
Resolution: Proof of operation provided.
Lifesaving › Launching Appliances › Davit
Issued 7 January 2010 Resolved
Provide proof of operation the port side rescue boat release mechanism, engine and controls.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2010
Resolved 29 April 2010
Resolution: Corrected
Fire Fighting › Fire Hoses › Condition
Issued 7 January 2010 Resolved
Perform hydrostatic test on all fire hoses on station and in-service throughout the Ship.
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 30 January 2010
Resolution: Proof of hydrostatic testing provided with results recorded in the ships log.
Lifesaving › Launching Appliances › Falls
Issued 7 November 2007 Resolved
Renew all Lifeboat Davit falls due 04NOV07.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2007
Resolved 7 May 2008
Resolution: Overhaul, wire replacement and load tests complete, SAT
Lifesaving › Rescue Boat › Markings
Issued 20 April 2007 Resolved
Provide manufacturer's data plates for [name withheld] Rescue Boat 160.156/75/0 and release gear 160.133/37/0 to match USCG Certificates of Approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 29 April 2008
Resolution: [name withheld] (China) finally shipped CG data plate.
Lifesaving › Lifeboat › Stability
Issued 20 April 2007 Resolved
Lifeboat 11 & 12 are no longer serviceable, based on Survival System International Report dated 19APR07. Total persons allowed is reduced by 64 until replaced with serviceable craft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2007
Resolved 14 December 2007
Resolution: MLB 11-12 have been surveyed and davits have been removed without replacement.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 12 October 2006 Resolved
Complete Periodic Safety Test Amendments for boiler automation and service diesel generator and auxiliary diesel generator
Due 15 October 2007
Resolved 2 December 2008
Resolution: Rev C approved
Fire Fighting › Fire Main › Material
Issued 12 October 2006 Resolved
Remove black iron pipe inserted section of firemain below bridge deck and replace with pipe of similar material
Due 12 April 2007
Resolved 2 November 2006
Resolution: CuNi installed and pressure tested SAT.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 12 October 2006 Resolved
Provide copy of NTVRP interim operation letter
Due 12 April 2007
Resolved 8 December 2006
Resolution: Integrated NTVRP/SOPEP. NTVRP 09MAY06; SOPEP 05MAY06; Replacement letter issued 24NOV06.
Deck/Cargo › Cargo Stowage › General
Issued 12 October 2006 Resolved
Provide current valid certificates and register of all cargo gear
Due 12 April 2007
Resolved 11 December 2006
Resolution: ABS issued 11DEC06
Lifesaving › Immersion Suits › Serviceable
Issued 12 October 2006 Resolved
Replace 12 immersion suits and provide a total of 50 per 46CFR199.214
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Resolution: new suits purchased, total 50 o/b.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 October 2006 Resolved
Replace missing PFD's as noted during SEP06 crew monthly inspection, provide a total of 2596 on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Resolution: corrected
Lifesaving › Lifeboat Equipment › Food Ration
Issued 12 October 2006 Resolved
Replace missing LB equipment as noted during SEP06 crew monthly inspection
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Resolution: missing/expired equipment replaced
Lifesaving › Lifeboat › Hull
Issued 12 October 2006 Resolved
Make MLB 11 and 12 available for thorough hull & releasing gear inspection
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Resolution: Examined ext/interior, required mfr report
Lifesaving › Launching Appliances › Release Mechanism
Issued 12 October 2006 Resolved
Lower and release MLB 11 & 12
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Engineering › Steering Gear System › Power Unit
Issued 12 October 2006 Resolved
Prove proper operation of all steering system indicators
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 12 October 2006
Lifesaving › Thermal Protective Aids › General
Issued 12 October 2006 Resolved
Replace damaged TPA's as noted by crew during SEP06 inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 12 October 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 October 2006 Resolved
Ensure stainless steel UL approved foam type portable fire extinguishers are located only in spaces allowed by the USCG National Defense Waiver 12SEP87.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 19 April 2007
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 12 October 2006 Resolved
Replace expired hydro releases on 2 fwd liferafts
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Resolution: replaced
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 October 2006 Resolved
Repair all FSD's to properly operate (missing handles, broken closures)
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Fire Fighting › Fire Main › Valves
Issued 12 October 2006 Resolved
Repair remote for firemain isolation valve
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 12 October 2006
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 12 October 2006 Resolved
Repair steam leaks and steam pipe lagging in laundry room
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 2 November 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 12 October 2006 Resolved
Clean laundry lint traps
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 12 October 2006
Stability › Severe Wind/Roll › General
Issued 12 October 2006 Resolved
Address removal of temp helo shelter per USCG-MSC letter 08FEB06.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 28 January 2008
Resolution: CG-5431 authorized continued use of "temporary" hleo shelter until next SY repair in 2010.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pressure
Issued 12 October 2006 Resolved
Prove proper operation of installed water mist system.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 8 December 2006
Resolution: Tested discharge at burner fronts
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 October 2006 Resolved
Provide approved plans & prove proper operation of fixed CO2 system for SSDG enclosure
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 19 April 2007
Resolution: Plans approved 23JAN07
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 October 2006 Resolved
Repair flush water leak at 1-51-1
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2007
Resolved 12 October 2006
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 12 October 2006 Resolved
Update FCP to reflect new fixed FF installations and submit to cog OCMI for approval
Due 15 October 2007
Resolved 25 March 2010
Resolution: Deficiency cleared based on vessel now having approved FCP onboard. ABS approval date 18SEP09 and USCG approval date 01JUL09 affixed to revised plan.
Deck/Cargo › Cargo Stowage › General
Issued 10 April 2006 Resolved
Provide CG approved drawings (4) iaw CG approval letter for Helicopter shelter dated 09FEB06. Provide drawing prior to continuing work on any project.
Action required: 705 - Other - as specified
Resolved 11 April 2006
Resolution: Received required drawings
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 10 April 2006 Resolved
Provide approved drawings for fixed fire extinguishing system to generator enclosure. Provide drawing prior to continuing work on any project.
Action required: 705 - Other - as specified
Resolved 18 May 2006
Resolution: Received final as-built reinstalled iaw original approved plan.
Lifesaving › Launching Appliances › Davit
Issued 10 April 2006 Resolved
Provide approved drawings of lifesaving equipment relocation. Provide documentation of relocated davits 12 & 14 can be operated, maintained, loaded & lowered from new location. Provide drawing prior to continuing work on any project.
Action required: 705 - Other - as specified
Resolved 25 April 2006
Resolution: Witnessed SAT op test. Received ABS approved drawings dated 13MAR06 for relocation and structure.
Lifesaving › Lifeboat › Propulsion Engine
Issued 19 August 2005 Resolved
Prove proper operation of the following lifeboats: #2, #4, #7, and #9. Crew unable to start propulsion engines.
Action required: 705 - Other - as specified
Resolved 22 August 2005
Lifesaving › Lifeboat › Propeller Shaft
Issued 19 August 2005 Resolved
Repair propeller shaft connecting pin and demonstrate proper operation. The shaft connection pin sheared off while demonstrating operation.
Action required: 705 - Other - as specified
Resolved 23 August 2005
Lifesaving › Lifeboat › Propeller Shaft
Issued 19 August 2005 Resolved
Properly install propeller shaft packing nut and demonstrate operation of lifeboat while waterborne. Packing nut was not attached to packing gland and condition unknown.
Action required: 705 - Other - as specified
Resolved 23 August 2005
Lifesaving › Lifeboat › Watertight Enclosure
Issued 17 August 2005 Resolved
Make battery compartment on the #1 and #2 life boats water tight in way of old bolt holes.
Action required: 705 - Other - as specified
Resolved 31 August 2005
Lifesaving › Lifeboat › Fire Protection (general)
Issued 17 August 2005 Resolved
Provide cover for fuse panel located inside battery compartment of the #1 and #2 lifeboats.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Fuse boxes renewed
Lifesaving › Lifeboat › Exhaust Pipe
Issued 17 August 2005 Resolved
Renew engine exhaust pipe for the #3 lifeboat.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Exhaust renewed
Lifesaving › Lifeboat › Exhaust Pipe
Issued 17 August 2005 Resolved
Properly mount exhaust pipe for # 5 lifboat to prevent contact with engine cover.
Action required: 705 - Other - as specified
Resolved 30 August 2005
Lifesaving › Lifeboat › Markings
Issued 17 August 2005 Resolved
Renew retro-reflective tape on gunnels of all lifeboats.
Due 5 September 2005
Resolved 25 August 2005
Lifesaving › Launching Appliances › Falls
Issued 17 August 2005 Resolved
Properly make up jam nuts for turnbuckles on all life boat falls.
Due 5 September 2005
Resolved 29 August 2005
Lifesaving › Launching Appliances › Falls
Issued 17 August 2005 Resolved
Renew corroded, missing, and undersized cotter pins for all lifeboat falls and attachments.
Due 5 September 2005
Resolved 23 August 2005
Lifesaving › Launching Appliances › Davit
Issued 17 August 2005 Resolved
Provide documantation for examination of all launching appliances in accordance with 46 CFR 199.190 (i) (2) and (i) (2).
Action required: 705 - Other - as specified
Resolved 7 September 2005
Lifesaving › Launching Appliances › Davit
Issued 17 August 2005 Resolved
Install new wire rope and perform full load weight test for all liferaft launching davits. Vessel is restricted to carrying no more than 1188 persons on board until corrected.
Action required: 705 - Other - as specified
Due 30 December 2005
Resolved 18 November 2005
Resolution: Witnessed sat weight test
Lifesaving › Lifefloat › Serviceable
Issued 17 August 2005 Resolved
Provide satisfactory repairs to the four buoyant apparatus by painting, retro tape renewal, and grab line renewal.
Action required: 705 - Other - as specified
Resolved 23 August 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 17 August 2005 Resolved
Provide and install cable brackets and supports for all missing cable supports at all lifeboat davit motors.
Action required: 705 - Other - as specified
Resolved 29 August 2005
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 16 August 2005 Resolved
Provide for each lifeboat a manually powered reverse osmosis desalinator approved under 46 CFR 160.058
Action required: 705 - Other - as specified
Resolved 25 August 2005
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 16 August 2005 Resolved
Provide on board each lifeboat sufficient sea sickness medication.
Action required: 705 - Other - as specified
Resolved 25 August 2005
Stability › Unintentional Flooding › General
Issued 29 July 2005 Resolved
Crop and renew 8 inch diameter suction pipe for fire pump suction in way of engine room, port foreward outboard of sea valve.
Action required: 705 - Other - as specified
Resolved 22 August 2005
Stability › Unintentional Flooding › General
Issued 29 July 2005 Resolved
Make adequate repairs to pitting in both forward and after condensor pump riser piping above sea valve in way of both main sea chests.
Action required: 705 - Other - as specified
Resolved 22 August 2005
Lifesaving › Lifeboat › Hull
Issued 18 July 2005 Resolved
Remove paint from area of repairs for examination and provide documentation that hull repair of the #11 lifeboat has been performed in accordance with manufacturers recommendations.
Action required: 705 - Other - as specified
Resolved 20 July 2005
Lifesaving › Launching Appliances › Falls
Issued 6 July 2005 Resolved
Make repairs to forward block of the number 12 rescue/lifeboat falls and prove proper operation of davits to properly stow rescue/lifeboat.
Action required: 705 - Other - as specified
Resolved 11 November 2005
Lifesaving › Visual Distress Signals (General) › Condition
Issued 6 July 2005 Resolved
Provide proof that life ring light batteries are correct for lights or renew with proper batteries.
Action required: 705 - Other - as specified
Resolved 17 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 July 2005 Resolved
Install lagging to steam piping located at after end of boson locker near stair tower to forepeak.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Lagging installed
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 6 July 2005 Resolved
Prove proper operation of bow lookout sound powered phone.
Action required: 705 - Other - as specified
Resolved 23 August 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 July 2005 Resolved
Provide missing covers for 110-volt receptacles on main deck
Action required: 705 - Other - as specified
Resolved 2 August 2005
Lifesaving › Lifeboat › Hull
Issued 6 July 2005 Resolved
Remove paint/unknown patching adjacent to repair patch on bottom of #11 lifeboat for further examination of repairs. Provide documentation of repairs meeting manufacturers approved repair procedure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2005
Stability › Unintentional Flooding › General
Issued 5 July 2005 Resolved
Renew the 30 inch diameter salt water supply piping between sea valve and first flange for AMR sea water supply system.
Action required: 705 - Other - as specified
Resolved 12 August 2005
Stability › Unintentional Flooding › General
Issued 5 July 2005 Resolved
Crop and renew longitudinal stringer on port side of AMR room in way of new high suction sea chest where stringer is utilized for sea chest plating. Stringer has pitting in excess of 25 percent.
Action required: 705 - Other - as specified
Resolved 12 August 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 14 June 2005 Resolved
Remove debris blocking CO2 discharge nozzle in forward Paint Locker
Action required: 705 - Other - as specified
Resolved 17 August 2005
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 21 September 2004 Resolved
Complete satisfactory testing of all steam propulsion machinery related items, including lifting of safety valves, prior to deployment.
Action required: 705 - Other - as specified
Due 30 March 2005
Resolved 31 August 2005
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 21 September 2004 Resolved
Prove ILR on bow are stowed not more than maximum allowable height
Action required: 705 - Other - as specified
Resolved 20 October 2004
Resolution: Verified with Chief Mate that stowage doesn''t exceed tolerance.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 21 September 2004 Resolved
Prove proper operation & manueverabilty of MLB #1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2004
Communications › Alarms/Indicators › General Alarm
Issued 21 September 2004 Resolved
Prove proper operation of all general alarm bells
Action required: 705 - Other - as specified
Resolved 20 October 2004
Resolution: Batteries weren''t compatible with chargers. Switched out batteries & op test sat.
Documentation › Markings/Placards › Warning Signs
Issued 21 September 2004 Resolved
Provide sign at WTD to Service Area #6 to indicate direction of manual closure operation.
Action required: 705 - Other - as specified
Resolved 20 October 2004
Lifesaving › Lifeboat › Handholds/Handrails
Issued 21 September 2004 Resolved
Renew wasted grab rails on lifeboats
Action required: 705 - Other - as specified
Resolved 4 May 2005
Resolution: All grab rails have been worked, de-scaled, and painted.
Operations/Management › Drills/Instruction › Fire
Issued 21 September 2004 Resolved
Conduct crew fire & abandonship drills.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2005
Resolution: Satisfactorily conducted fire and abondon ship drill with civilian mariners and medical troop force (MTF).
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 21 September 2004 Resolved
Provide proper documentation of all crew members.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2005
Resolution: Verified all crewmembers
Lifesaving › Inflatable Liferafts › Weak Link
Issued 16 September 2003 Resolved
Provide certification for weak link breakin strength for all inflatable liferafts. LEGACY COMPONENT DESC: Weak Link
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 22 July 2004
Fire Fighting › Structural - Horizontal Zones › General
Issued 16 September 2003 Resolved
Repair insulation on forward bulkhead in Compressor Room.
Due 22 November 2003
Resolved 22 July 2004
Fire Fighting › Structural - Main Vertical Zones › General
Issued 16 September 2003 Resolved
Provide material spec sheets for GMDSS structural penetrations for cable installation.
Due 22 November 2003
Resolved 22 July 2004
Stability › Watertight Integrity
Issued 16 September 2003 Resolved
Install time delay for WTD 1, 2, & 3 IAW ASTM 1196 & 1197.
Due 22 November 2003
Resolved 1 April 2004
Resolution: [name withheld] attended vessel and witnessed satisfactory operation of time delay
Deck/Cargo › Mooring/Anchoring
Issued 16 September 2003 Resolved
Repair hydraulic leak on starboard anchor gear. LEGACY COMPONENT DESC: Capstan
Due 22 November 2003
Resolved 7 January 2004
Lifesaving › Lifeboat Equipment
Issued 16 September 2003 Resolved
Provide additional 200 provisions for life boats. LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2003
Resolved 22 October 2003
Stability › Watertight Integrity
Issued 16 September 2003 Resolved
Repair hydraulic leak and stiff movement on remote hand crank for WTD #3.
Due 22 November 2003
Resolved 7 January 2004
Electrical › Electric Supply System (service)
Issued 16 September 2003 Resolved
Repair exposed wires aft of Flam Stores 01-42-4. LEGACY COMPONENT DESC: Cable
Due 22 November 2003
Resolved 7 January 2004
Fire Fighting › Miscellaneous Items
Issued 16 September 2003 Resolved
Replace glass on cover for General Alarm in Emergency Diesel Generator Room.
Due 22 November 2003
Resolved 7 January 2004
Electrical › Electric Supply System (service)
Issued 16 September 2003 Resolved
Install outlet cover for outlet near Lifeboat #5.
Due 22 November 2003
Resolved 7 January 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 September 2003 Resolved
Ensure FSD's 76, 82, 61 &65 properly latch when closed.
Due 22 November 2003
Resolved 22 July 2004
Electrical › Electric Supply System (service)
Issued 16 September 2003 Resolved
Remove extension cord in overhead outside Post Office.
Due 22 November 2003
Resolved 7 January 2004
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 September 2003 Resolved
Conduct satisfactory abandon ship drill prior to getting underway. LEGACY COMPONENT DESC: Abandon Ship
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2004
Operations/Management › Drills/Instruction › Fire
Issued 16 September 2003 Resolved
Conduct satisfactory fire drill prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2004
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 16 September 2003 Resolved
Provide original licenses of crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2004
Fire Fighting › Structural - A Class Divisions
Issued 16 September 2003 Resolved
Provide installation procedures for bulkhead penetrations thru forward bulkhead in Compressor Room. LEGACY COMPONENT DESC: Bulkheads - Service Spaces
Due 22 November 2003
Resolved 7 January 2004
Electrical › Lighting (emergency)
Issued 16 September 2003 Resolved
Repair all identified inoperable emergency lighting including embarkation stations for liferafts (IAW 46 CFR 112.15-1(g)). LEGACY COMPONENT DESC: Lighting Fixture
Due 22 November 2003
Resolved 7 January 2004
Fire Fighting › Ventilation Systems
Issued 16 September 2003 Resolved
Provide list of inoperable fire dampers.
Due 22 November 2003
Resolved 7 January 2004
Resolution: All repaired.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 September 2003 Resolved
Provide operable Reverse poower relay for #2 SST generator
Condition: Unknown
Due 11 June 2004
Resolved 7 January 2004
Resolution: Tested SAT
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 16 September 2003 Resolved
Inspect and repair all fire stop cable penetrations, vertical and horizontal, throught all 6 forward main fire zones.
Condition: Improper Installation
Due 31 August 2004
Resolved 1 December 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 17 October 2002 Resolved
Install globe over light bulb on the lighting fixture in the reefer space.
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 29 October 2002
Resolution: Vessel crew installed globe over fixture.
Communications › Alarms/Indicators
Issued 17 October 2002 Resolved
Prove proper operation of the ships general alarm in way of alarm bells upper level engine room on the starboard side and on the weather deck at the fan tail. LEGACY COMPONENT DESC: General Alarm
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 4 December 2002
Resolution: All bells operating satisfactorily.
Fire Fighting › Fire Hydrants › Condition
Issued 17 October 2002 Resolved
Provide a spanner wrench for fire station #31
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 30 October 2002
Resolution: Vessel''s crew provided the required spanner wrench.
Communications › Visual Communication › Red Warning Signal
Issued 17 October 2002 Resolved
Repair and prove proper operation of the general alarm red warning beacon in way of the engine room, lower level.
Condition: Unknown
Due 4 December 2002
Resolved 4 November 2002
Resolution: Verified that the light is functioning properly.
Deck/Cargo
Issued 17 October 2002 Resolved
Adequately preserve wood rungs on the accommodation ladder.
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 4 December 2002
Resolution: Ship''s crew completed the accommodation ladder maintenance
Engineering › Steam System (auxiliary)
Issued 17 October 2002 Resolved
Complete repairs to steam piping in way of leaking auxiliary steam return from lube oil storage tank, upper level engine room, starboard side. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 4 December 2002
Resolved 4 December 2002
Resolution: Crew installed new piping and tested.
Fire Fighting › Ventilation Systems
Issued 17 October 2002 Resolved
Repair and prove proper operation of seized fire damper #01-140-2 in way of emergency battery storage space. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 4 December 2002
Resolution: Installed new remote cable.
Electrical › Electrical Distribution System (emergency)
Issued 17 October 2002 Resolved
Repair emergency switchboard lock out switch, for the main switchboard feed back breaker, on the emergency switchboard. LEGACY COMPONENT DESC: Main-emergency Bus Tie
Condition: Unknown
Due 4 December 2002
Resolved 4 December 2002
Resolution: crew installed new switch.
Electrical › Electrical Distribution System (service)
Issued 17 October 2002 Resolved
Remove dead end wiring in compartment 3-40-0. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 4 December 2002
Resolved 4 December 2002
Resolution: wiring removed
Engineering › Bilge Water Management System
Issued 17 October 2002 Resolved
Provide the required drawings and a request for aproval of the installation of the rose box eductor system in the ships service hold areas. LEGACY COMPONENT DESC: Eductor
Due 4 December 2002
Resolved 4 December 2002
Resolution: Plans submitted for review and approval.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System
Issued 17 October 2002 Resolved
Provide accurate labeling on control valves for the AFFF sprinkling system. Valve lables do not match the posted system operating instruction. LEGACY COMPONENT DESC: Control Valves
Condition: Improper Installation
Due 4 December 2002
Resolved 19 December 2002
Electrical › Lighting (emergency)
Issued 17 October 2002 Resolved
Prove proper operation of the battery powered emergency lighting in way of the after house. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Due 4 December 2002
Resolved 4 December 2002
Resolution: Emergency lighting operating satisfactorily.
Accommodation/Occupational Safety › Ventilation
Issued 12 September 2002 Resolved
Provide access cover to ventilation duct servicing grease locker (supply).
Due 12 October 2002
Resolved 15 November 2002
Resolution: Vessel''s crew installed a ventilation cover.
Fire Fighting › Ventilation Systems
Issued 12 September 2002 Resolved
Provide readily accessible means to secure all external manual fire dampers to the satisfaction of an attending marine inspector. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 12 October 2002
Resolved 28 January 2003
Resolution: Welded steps attached to the bulkhead provide access to close manual dampers.
Fire Fighting
Issued 13 August 2001 Resolved
REPAIR CLOSURE OF FIRESCREEN DOOR #87
Condition: Unknown
Due 1 September 2001
Resolved 4 September 2001
Electrical
Issued 13 August 2001 Resolved
Demonstrate proper operation of emergency lighting and temporary power sources.
Condition: Unknown
Due 13 September 2001
Resolved 19 October 2001
Accommodation/Occupational Safety
Issued 13 August 2001 Resolved
Demonstrate proper operation of crew's laundry dryer exhaust vent fan.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Accommodation/Occupational Safety
Issued 13 August 2001 Resolved
Repair sewage leak in compartment 3-36-2.
Condition: Unknown
Due 1 September 2001
Resolved 4 September 2001
Fire Fighting
Issued 13 August 2001 Resolved
Complete repairs to the aft fire pump PRV and prove proper operation.
Condition: Unknown
Due 1 December 2001
Resolved 31 August 2001
Fire Fighting
Issued 13 August 2001 Resolved
COMPLETE REPAIRS TO FWD FIRE PUMP CHECK VALVE AND DEMONSTRATE PROPER OPERATION.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 9 August 2000 Resolved
Complete in the presence of USCG marine inspector, weight test for life raft launching appliances IAW 46CFR199.45(b)
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Construction/Loadline
Issued 9 August 2000 Resolved
Demonstrate/provide documentation indicating lower level steam driven pump (ballast) will secure via overspeed trip.
Condition: Unknown
Due 16 August 2000
Resolved 23 August 2000
Electrical
Issued 9 December 1999 Resolved
UPDATE AND POST FEED BACK INSTRUCTIONS ON THE EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Electrical
Issued 9 December 1999 Resolved
PROVIDE TRIP SETTINGS FOR EMERGENCY GENERATOR FEED BREAKER AND EMERGENCY SWITCHBOARD FEEDBACK BREAKER IAW 46CFR112.05-3(C).
Condition: Unknown
Due 5 January 2000
Resolved 5 January 2000
Engineering
Issued 18 November 1999 Resolved
Upon completion of installation of Lube Oil Purifier system and Main Control Consul alarm Switches, Notify Local OCMI to schedule follow-up inspection. Items scheduled to be completed on or before 30 April 2000.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Lifesaving
Issued 27 August 1999 Resolved
Provide frames for covers for lifeboat No. 11 and 12 no later than 31 October 1999.
Condition: Unknown
Due 31 October 1999
Resolved 7 October 1999
Lifesaving
Issued 27 August 1999 Resolved
Install Reflective Tape on all lifeboats as per NVIC.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Fire Fighting
Issued 27 August 1999 Resolved
Service fixed system (Fire) for deep fat fryer and donut fryer, both shstems show discharged.
Condition: Unknown
Due 31 October 1999
Resolved 7 October 1999
Unknown
Issued 27 August 1999 Resolved
Upon installation of the following items notify local OCMI to schedule an inspection of those items: Oily water seperator, Lube oil purifier, ADG controls, SSDG overhaul and Mail consol switches. Items to be completed by 31 October 1999.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Electrical
Issued 27 August 1999 Resolved
Provide plans for electrical system renewal in aft laundry room.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Lifesaving
Issued 27 August 1999 Resolved
Renew wire rope fall on all Lifeboat Davits, conduct weight test releasing gear. Test to be witnessed by USCG inspector no later than 31 October 1999.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Electrical
Issued 26 August 1998 Resolved
CORRECTLY BAND THE DANGLING CABLES IN VICINITY OF SERVICE AREA 2
Condition: Unknown
Due 10 September 1998
Resolved 19 November 1998
Fire Fighting
Issued 26 August 1998 Resolved
PROVIDE PROOF THAT ALL PORTABLE AFFF FIRE EXTINGUISHERS MEET NFPA 10 (3 YEAR EMPTY AND REFILL REQMT)
Condition: Unknown
Due 10 September 1998
Resolved 19 November 1998
Electrical
Issued 26 August 1998 Resolved
COMPLETELY REMOVE OR PERMANENTLY AND CORRECTLY WIRE THE GRINDER IN SERVICE AREA 2
Condition: Unknown
Due 10 September 1998
Resolved 19 November 1998
Electrical
Issued 26 August 1998 Resolved
PROVIDE DOCUMENTATION OF PROPER OPERATION OF THE EMERGENCY LIGHTING SYSTEM
Condition: Unknown
Due 10 September 1998
Resolved 28 August 1998
Fire Fighting
Issued 2 April 1998 Resolved
REPAIR AS NEW PORPORTIONER VALVE FOR AFFF SYSTEM IN WAY OF AFFF ROOM. THISITEM TO BE COMPLETED PRIOR TO SAILING TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Electrical
Issued 18 December 1997 Resolved
REPAIR AS NEW MANUAL THROTTLE VALVE ON SSTG
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Engineering
Issued 8 October 1997 Resolved
REPAIR OIL LEAK ON DIESEL SERVICE GENERATOR
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Engineering
Issued 8 October 1997 Resolved
REPAIR AS NEW FWD AUX STEAM STOP VALVE ON STBD BOILER. VALVE BODY IS CRACKED. THIS VALVE SHALL BE REPAIRED PRIOR TO GETTING THE VESSEL U/W
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997 Resolved
REPAIR FRACTURE IN BULKHEAD IN WAY OF NTD 01-64-1
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Lifesaving
Issued 6 August 1997 Resolved
PROVIDE IMMERSION SUITS FOR ALL PERSONS ONBOARD.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Engineering
Issued 6 August 1997 Resolved
REPAIR AND SHOW PROPER OPERATION OF REMOTE REACH RODS ON STBD F/O SERVICE TANK.
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Engineering
Issued 6 August 1997 Resolved
INSTALL FLANGE MATERIAL IN L/O LINE COOLER OUTLET LINE
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Construction/Loadline
Issued 6 August 1997 Resolved
PROVIDE COPY OF BILGE PUMP OPERATION LOG FOR FWD BILGE PUMPS OR SHOW SATISFACTORY OPERATION.
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Fire Fighting
Issued 6 August 1997 Resolved
PROPERLY LABEL VALVES ON FIXED FOAM DISTRIBUTION PIPING
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Lifesaving
Issued 6 August 1997 Resolved
REPAIR FIBERGLASS DAMAGE TO #4 LIFEBOAT ON KEEL WHERE GEL COAT HAS BEEN SCRATCHED AWAY AND FIBERS ARE EXPOSED.
Condition: Unknown
Due 20 August 1997
Resolved 6 October 1997
Engineering
Issued 6 August 1997 Resolved
PRIOR TO GETTING U/W SHOW SATISFACTORY OPERATION OF PROPULSION BOILERS, PROPULSION MACHINERY, SAFETY DEVICES, BOILER SAFETY VALVE EASING GEAR, FEEDWATER PUMPS, STG SAFETY TESTS, AND BOILER AUTOMATION TO THE SATISFACTION OFTHE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Construction/Loadline
Issued 6 August 1997 Resolved
ADJUST AND CHALK TEST FIREDOOR BETWEEN INCINERATOR FLAT AND ACCOMODATION SPACE.
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Fire Fighting
Issued 6 August 1997 Resolved
RENEW ALL WELDED JOINTS IN SERVICE AREA NO. 1 FIREMAIN SYSTEM. EXISTING SYSTEM AS INSTALLED IS USING A FILLER METALS WITH A MELTING TEMPERATURE LESS THAN 1700 DEGREES FAHRENHEIT. THIS IS UNACCEPTABLE PRACTICE REF: 46CFR56.50-1(a)
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 6 August 1997 Resolved
PROVIDE PROPER SECURING BRACKETS FOR REFRIGERENT RECOVERY BOTTLES IN AC FLAT PER 46CFR 147.60(B)
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Construction/Loadline
Issued 6 August 1997 Resolved
INSTALL ROSE BOX SCREENS IN BILGE SYSTEM
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Fire Fighting
Issued 6 August 1997 Resolved
REPAIR LEAKING FIREPLUG VALVES ON FIRE STATION #123, 120, 119
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Lifesaving
Issued 6 August 1997 Resolved
PROPERLY SECURE MACHINERY IN SERVICE AREA 6 6-78-0-M I.E. SHEAR, ELECTRICALHACK SAW, AND OTHER MACHINERY.
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Engineering
Issued 6 August 1997 Resolved
PROPERLY LABEL F/O SERVICE SYSTEM SLUDGE TANK SUCTION VALVE
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Navigation
Issued 6 August 1997 Resolved
REPAIR STEERING GEAR ALARM LAMPS AND ALARM ON THE BRIDGE
Condition: Unknown
Due 20 August 1997
Resolved 6 October 1997
Navigation
Issued 6 August 1997 Resolved
POST EMERGENCY STEERING INSTRUCTIONS ON THE BRIDGE
Condition: Unknown
Due 20 August 1997
Resolved 6 October 1997
Construction/Loadline
Issued 6 August 1997 Resolved
SHOW SATISFACTORY OPERATION OF OWS
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Engineering
Issued 6 August 1997 Resolved
PROVIDE PROOF OF DATE OF MANUFACTURE ON FLEXIBLE NON METALLIC HOSES (3EA) IN WAY OF MAIN CONDENSOR. RENEW IF HOSES ARE MORE THAN 10 YEARS OLD.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 6 August 1997 Resolved
make permanent repairs to drain pipe in way of 1-30-2 locker^
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Documentation
Issued 6 August 1997 Resolved
UPDATE POLLUTION & OIL TRANSFER PROCEDURES TO MEET THE REQUIREMENTS OF 33CFR 155.720 (THIS REQUIREMENT GIVEN AS A RESULT OF THE VSLS RECENT RELOCATION TO SAN DIEGO)
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Construction/Loadline
Issued 6 August 1997 Resolved
PROVIDE DISCHARGE CONTAINMENT FOR BILGE DRAIN VALVE IN WAY OF EDG STBD AFT DRAIN, IN ADDITION PROPERLY MARK VALVE.
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Engineering
Issued 6 August 1997 Resolved
conduct hydrostatic test of both propulsion boilers to 1.25 MAWP in the pressence of and to the satisfaction of the attending Marine Inspection
Condition: Unknown
Due 6 September 1997
Resolved 6 October 1997
Lifesaving
Issued 6 August 1997 Resolved
LABEL LINE THROWING GUN LOCKER
Condition: Unknown
Due 20 August 1997
Resolved 6 October 1997
Accommodation/Occupational Safety
Issued 6 August 1997 Resolved
PROVIDE EMERGENCY INSTRUCTIONS FOR ALL PASSENGER CABINS AND ALL SPACES OCCUPIED BY PERSONS OTHER THAN THE CREW.
Condition: Unknown
Due 20 August 1997
Resolved 6 October 1997
Electrical
Issued 6 August 1997 Resolved
REPAIR WATERTIGHT DOOR LAMPS ON BRIDGE
Condition: Unknown
Due 20 August 1997
Resolved 6 October 1997
Fire Fighting
Issued 19 June 1997 Resolved
Demonstrate that the engine room diesel service generator will properly secure, prior to the halon fire fighting system discharging.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 10 April 1997 Resolved
Provide a copy of brazing procedures used for firemain system in service Area 1.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Documentation
Issued 14 February 1997 Resolved
PROVIDE APPROVED DRAWINGS FOR THE INSTALLATION OF DOORS ON THE VERTICAL ESCAPE TRUNK IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Accommodation/Occupational Safety
Issued 14 February 1997 Resolved
PROVIDE FOR FINAL INSPECTION OF CATWALK EXPANSION JOINT AND APPROVED DRAWINGS
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997 Resolved
PROVIDE DRAWINGS FOR REVIEW AND APPROVAL FOR THE STAIRTOWER AND ELEVATOR DOORS IN ACCORDANCE WITH 46 CFR 72.05-20(F)
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997 Resolved
PROVIDE A COPY OF MATERIAL SPECIFICATIONS USED IN FIREMAIN SYSTEM IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Fire Fighting
Issued 14 February 1997 Resolved
TEST ALL NEW STATIONS OF THE MANUAL ALARM SYSTEM IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Accommodation/Occupational Safety
Issued 14 February 1997 Resolved
PROVIDE FOR INSPECTION OF ALL DAMPERS IN SUPPLY AND EXHAUST SYSTEMS WITH REMOTE OPERATION IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Electrical
Issued 14 February 1997 Resolved
CONDUCT A TEST OF EMERGENCY LIGHTING IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997 Resolved
PROVIDE DRAWINGS (APPROVED) FOR MODIFICATIONS OF THE DECON STATIONS.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Fire Fighting
Issued 14 February 1997 Resolved
OPERATIONAL TEST OF FIRE DETECTION SYSTEM (ALL LOCATIONS) IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Electrical
Issued 14 February 1997 Resolved
PROVIDE INFORMATION ON SIZE OF THE BATTERY CHARGING INSTALLATION IN ACCORDANCE WITH 46 CFR 111.15
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997 Resolved
PROVIDE COPIES FOR REVIEW AND APPROVAL OF THE FOLLOWING PLANS; DISPLAY, FIRE CONTROL, STRUCTURAL FIRE PROTECTION
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Fire Fighting
Issued 14 February 1997 Resolved
PROVIDE A COPY OF MATERIAL CERTIFICATIONS, WELDING PROCEEDURES FOR THE FOAMTANK INSTALLATION.
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Documentation
Issued 14 February 1997 Resolved
PROVIDE A COPY OF WELD PROCEDURES USED FOR FIREMAIN SYSTEM IN SERVICE AREA 1
Condition: Unknown
Due 14 February 1997
Resolved 14 February 1997
Fire Fighting
Issued 23 August 1996 Resolved
EXAMINE ALL PENETRATIONS IN FIRE BOUNDRIES AND REPAIR AS NECESSARY.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Lifesaving
Issued 23 August 1996 Resolved
PRIOR TO VESSEL ACTIVATION, CONDUCT SATISFACTORY FIRE AND BOAT DRILLS IN THE PRESENCE OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 August 1996
Resolved 23 August 1996
Lifesaving
Issued 23 August 1996 Resolved
SHOP TEST AND PROVIDE REPORT FOR ALL 16 RELIEF VALVES ON COAST GUARD INSPECTED PRESSURE VESSELS.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Lifesaving
Issued 23 August 1996 Resolved
REPAIR/REPLACE UPPERMOST LIFEFLOAT ON PORTSIDE.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Lifesaving
Issued 23 August 1996 Resolved
PROVIDE 4.3 KILOGRAM LIFE RINGS FOR BRIDGE WING RELEASE SYSTEM.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Lifesaving
Issued 23 August 1996 Resolved
REPAIR FRACTURES LOCATED IN SEATING AND MOTORMOUNTS FOR LIFEBOATS 11 & 12.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Lifesaving
Issued 23 August 1996 Resolved
CHANGE OUT THE FUEL IN EACH OF THE VESSEL'S LIFEBOATS.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Unknown
Issued 23 August 1996 Resolved
RE-ALIGN THE FUEL PIPE HEADER FOR THE STARBOARD BUNKER STATION TO REMAIN OVER THE CONTAINMENT.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Fire Fighting
Issued 23 August 1996 Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOOR 82.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Lifesaving
Issued 23 August 1996 Resolved
CONDUCT SATISFACTORY WEIGHT TEST OF #3 LIFERAFT DAVIT.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Electrical
Issued 23 August 1996 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING AT THE FOLLOWING LOCATIONS; 02-41-2, 2-43-1, 3-47-5, 4-47-0, 1-83-8, 1-83-1, 4-83-3, 1-59-1, MEDICAL ADMIN, MSD SERVICE SPACE, SERVICE AREA #4, CO'S OFFICE AND ADJACENT TO LIGHTING PANEL L201.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Fire Fighting
Issued 23 August 1996 Resolved
PROVE PROPER OPERATION OF FIRE DAMPERS AT THE FOLLOWING LOCATIONS; 01-42- 13, 01-61-8, 01-64-9, 01-64-11, 02-40-4, 1-51-2, 1-53-4, 1-54-0, 2-51-7, 2-42-3, 2-42-4, 2-61-1, 2-42-2, 3-52-4, 3-61-1, 3-61-4, 4-52-4, 4-43-2, 4-61-5, 4-61-1, 4-67-1, 5-44-1.
Condition: Unknown
Due 23 September 1996
Resolved 3 October 1996
Electrical
Issued 2 May 1996 Resolved
CONDUCT AUTOMATION TEST OF SSTG & SSDG, PROVING SSDG START & ASSUMPTION OF ELECTRICAL LOAD UPON REDUCTION OF LINE VOLTAGE ON SSTG. <CASREP ITEM>
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Fire Fighting
Issued 2 May 1996 Resolved
DEMONSTRATE REMOTE OPERATION OF STEAM TURBINE FIRE PUMP & REACH ROD FOR OVERBOARD VALVE. ENSURE THE OVERBOARD VALVE DOESN'T LEAK. <CASREP ITEM>
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Accommodation/Occupational Safety
Issued 9 February 1996 Resolved
RESET RELIEF VALVE FOR HOT WATER HEATER LOCATED IN SERVICE AREA #3 TO 150 PSI OR LOWER. PROVIDE SERVICE REPORT.
Condition: Unknown
Due 28 May 1996
Resolved 24 May 1996
Accommodation/Occupational Safety
Issued 9 February 1996 Resolved
RESET RELIEF VALVE FOR EMERGENCY GENERATOR START AIR RECEIVER (# 66777) TO 430 PSI OR LOWER. PROVIDE SERVICE REPORT.
Condition: Unknown
Due 28 May 1996
Resolved 24 May 1996
Fire Fighting
Issued 9 February 1996 Resolved
CONDUCT FIRE DRILL PRIOR TO ACTIVATION OR INSPECTION FOR CERTIFICATION
Condition: Unknown
Due 4 May 1996
Resolved 4 May 1996
Engineering
Issued 9 February 1996 Resolved
PROVIDE "RACOR" STYLE METAL FLAME IMPINGEMENT BOWLS FOR 2 FUEL FILTERS OF SSDG. TO BE COMPLETED PRIOR TO NEXT SAILING BUT NO LATER THAN 29MAR96.
Condition: Unknown
Due 29 March 1996
Resolved 28 February 1996
Lifesaving
Issued 9 February 1996 Resolved
CONDUCTED LIFE BOAT DRILL PRIOR TO ACTIVATION OR INSPECTION FOR CERTIFICATION
Condition: Unknown
Due 4 May 1996
Resolved 4 May 1996
Electrical
Issued 9 February 1996 Resolved
MARK "E" LIGHTS ON AMR MAIN SWITCHBOARD. TO BE COMPLETED PRIOR TO SAILING BUT NO LATER THAN 29MAR96.
Condition: Unknown
Due 29 March 1996
Resolved 28 February 1996
Accommodation/Occupational Safety
Issued 9 February 1996 Resolved
PROVE PROPER OPERATION OF RELIEF VALVE OF AMR DIESEL START AIR TANK. AFTER RELIEF (LESS THAN OR EQUAL TO 475 PSI) THERE MUST BE SUFFICIENT AIR IN TANKTO START DIESELS AFTER RELIEF RESETS. TO BE COMPLETED PRIOR TO SAILING BUT NO LATER THAN 29MAR96.
Condition: Unknown
Due 29 March 1996
Resolved 28 February 1996
Construction/Loadline
Issued 9 February 1996 Resolved
PROVE OWS ALARM AND THAT OWS OVERBOARD SECURES. TO BE COMPLETED PRIOR TO SAILING BUT NOT LATER THAN 29MAR96.
Condition: Unknown
Due 29 March 1996
Resolved 28 February 1996
Construction/Loadline
Issued 9 February 1996 Resolved
CONDUCT OPERATIONAL TEST OF BILGE SYSTEM (SERVICE AREA 1) PRIOR TO ACTIVATION OR INSPECTION FOR CERTIFICATION
Condition: Unknown
Due 29 August 1996
Resolved 28 February 1996
Construction/Loadline
Issued 9 February 1996 Resolved
REPAIR GAUGE LINE ON NO. 1 BILGE/BALLAST PUMP. TO BE COMPLETED PRIOR TO SAILING BUT NO LATER THAN 29MAR96.
Condition: Unknown
Due 29 March 1996
Resolved 28 February 1996
Accommodation/Occupational Safety
Issued 9 February 1996 Resolved
REPLACE AIR CHARGING LINES FOR HOSPITAL (FWD) AND ENGINE ROOM POTABLE_x001C_ WATER TANKS WITH QUICK DISCONNECT FITTINGS. TO BE COMPLETED PRIOR TO SAILING BUT NO LATER THAN 29MAR96.
Condition: Unknown
Due 29 March 1996
Resolved 28 February 1996
Navigation
Issued 9 February 1996 Resolved
PRIOR TO DEPARTURE FROM SAN DIEGO, CA, PROVE PROPER OPERATION OF VESSEL'S 10 CM RADAR. THE VESSEL MUST ADHERE TO THE CONDITIONS OF THE MSO SF BAY COTP LETTER OF DEVIATION DATED 11APR96 WHILE ENROUTE TO SAN DIEGO, CA. TO BE COMPLETED NO LATER THAN 30APR96.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Documentation
Issued 5 January 1996 Resolved
PROVIDE COPIES OF APPROVED PLANS FOR ALL STRUCTURAL MODIFICATION WORK CONDUCTED DURING DRYDOCK PERIOD OF OCT95 THRU JAN96
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Engineering
Issued 14 June 1995 Resolved
REPAIR NO. 2 IGNITER SUPPORT IN BURNER DIFFUSER FOR PORT BOILER.
Condition: Unknown
Due 14 July 1995
Resolved 19 June 1995
Lifesaving
Issued 15 December 1994 Resolved
DEMONSTRATE NORMAL RUNNING CONDITION OFENGINE ON #10 LIFEBOATAND TEST OPERATION OF THE ENGINES TRANSMISSION IN FORWARD AND ASTERN AS WELL AS OPERATION OF TEMPERATURE AND OIL PRESSURE GAUGES.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Lifesaving
Issued 15 November 1994 Resolved
TEST OPERATION OF THE ENGINE TRANSMISSION. CHANGE FLUID IF NEEDED.
Condition: Unknown
Due 21 December 1994
Resolved 3 January 1995
Lifesaving
Issued 15 November 1994 Resolved
CHECK OPERATION OF TEMPERATURE GAUGE AND OIL PRESSURE GAUGE.
Condition: Unknown
Due 21 December 1994
Resolved 3 January 1995
Engineering
Issued 15 November 1994 Resolved
SUBMIT VALVE CERTIFICATION FOR NEW VALVE USED IN SUPER HEATER BLOWDOWN.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Engineering
Issued 15 November 1994 Resolved
SUBMIT EVIDENCE AS TO WHAT STBD SUPER HEATER HEADER "P" NUMBER IS. PROCEDURE P34-GTA-1, USED TO REPAIR DRAIN LINE, USES A P-34 MATERIAL.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Lifesaving
Issued 15 November 1994 Resolved
DEMONSTRATE NORMAL RUNNING CONDITION OF ENGINE ON # 10 MLB.
Condition: Unknown
Due 21 December 1994
Resolved 3 January 1995
Engineering
Issued 15 November 1994 Resolved
CONDUCT 1.25 MAWP HYDRO OF STBD SUPERHEATER TO PROVE WELD REPAIRS TO PLUGGED TUBE IN LOWER SECTION._x001C_ TO BE CLEARED PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 1 March 1995
Resolved 8 February 1995
Engineering
Issued 15 November 1994 Resolved
NOTIFY MSO SAN FRANCISCO AS TO WHAT PROCEDURE (CGABS-02 SMAW OR CGABS-04 SMAW) WAS USED TO REPAIR STBD SUPER HEATER.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Engineering
Issued 29 August 1994 Resolved
CONDUCT FIRE AND WATERSIDE EXAMS OF BOTH MAIN BOILERS
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Lifesaving
Issued 29 August 1994 Resolved
PROVIDE ADEQUATE STOWAGE FOR ALL MEDICAL SUPPLIES PRIOR TO GETTING UNDERWAYFOR ANY REASON.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Engineering
Issued 29 August 1994 Resolved
REMOVE OPENING FROM SIDE OF JP5 TANK ON HELO DECK OR PROVIDE CG PLAN APPROVAL ON TANK CONSTRUCTION WITH SIDE CLEAN OUT/INSPECTION PLATE.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
RENEW #6 MACERATOR MOTOR BEARINGS IN SERVICE AREA #2 AS PER ELTECH REPORT #37173 DTD 01AUG94._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1995
Resolved 23 November 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
REPAIR #5 CELL AMP METER IN SERVICE AREA #2 AS PER ELTECH REPORT #37173 DTD01AUG94._x001C_
Condition: Unknown
Due 5 January 1995
Resolved 13 December 1994
Navigation
Issued 29 August 1994 Resolved
PROVE OPERATION OF AIR WHISTLE P/V RELIEF VALVE
Condition: Unknown
Due 11 October 1994
Resolved 28 October 1994
Fire Fighting
Issued 29 August 1994 Resolved
REPAIR/ADJUST AND PROVE OPERATION OF FIRE SCREEN DOOR #122 (3-71-0).
Condition: Unknown
Due 29 September 1994
Resolved 3 October 1994
Navigation
Issued 29 August 1994 Resolved
PROVE OPERATION OF PORT BRIDGE WING SHAFT RPM INDICATOR.
Condition: Unknown
Due 23 December 1994
Resolved 14 December 1994
Fire Fighting
Issued 29 August 1994 Resolved
CONDUCT SATISFACTORY FIRE & BOAT DRILL WITH SHIP'S CREW PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 29 August 1994
Resolved 29 August 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
RENEW TWO SCR'S FOR #1 CELL RECTIFIER IN SERVICE AREA #2 AS PER ELTECH REPORT #37173 DTD 01AUG94._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1995
Resolved 13 December 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
REPAIR ALARM PANEL FOR ELEVATORS (YARD PKG T-AH19 #304)
Condition: Unknown
Due 31 December 1995
Resolved 28 October 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
PROVIDE MAINTENANCE REPORT FOR OR PROVE OPERATION OF CATALYTIC SOLENOID VALVES, MSD TANKS, CELLS 1/2/3
Condition: Unknown
Due 11 October 1994
Resolved 3 October 1994
Electrical
Issued 29 August 1994 Resolved
REPAIR AMR ALARM PANEL (YARD PKG T-AH19 #303)
Condition: Unknown
Due 31 December 1995
Resolved 28 October 1994
Fire Fighting
Issued 29 August 1994 Resolved
REPAIR/REPLACE GAUGE FOR REMOTE OPERATING STATION FOR FORWARD FIRE PUMP
Condition: Unknown
Due 11 October 1994
Resolved 28 October 1994
Fire Fighting
Issued 29 August 1994 Resolved
PROVIDE SERVICING REPORT FOR ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 11 October 1994
Resolved 3 October 1994
Accommodation/Occupational Safety
Issued 29 August 1994 Resolved
RENEW #3 MACERATOR PUMP BEARING IN SERVICE AREA #5 AS PER ELTECH REPORT #37173 DTD 01AUG94._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1995
Resolved 23 November 1994
Fire Fighting
Issued 11 April 1994 Resolved
IN LIEU OF FIXED FOAM SYSTEM FOR AFT GALLEY DEEP FAT FRYER, PROVIDE A B-II DRY CHEMICAL OR NAVY PKP PORTABLE FIRE EXTINGUISHER IN ADDITION TO THE CO2 PORTABLE MOUNTED IN THE VICINITY OF THE DEEP FAT FRYER.
Condition: Unknown
Due 15 April 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVIDE A HALON SIREN WARNING PLACARD IN THE O2/N2 COMPRESSOR ROOM.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVIDE TWO PLACARDS FOR FORWARD PAINT LOCKER. FIRST PLACARD AT VENT SHUT DOWN SWITCH OUTSIDE OF DOOR STATING " RESET DAMPER MANUALLY ON WEATHER DECKABOVE." THE SECOND AT THE VENT SHUTDOWN SERVO ON THE FOCSLE WEATHER DECK STATING "RESET DAMPER MANUALLY AFTER REMOTE ACTIVATION."
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVIDE A PLACARD FOR ELEVATOR SHAFT SIDE OF ELEVATOR DOOR TO ENGINEERING CONTROL CENTER STATING "WARNING CO2 PROTECTED SPACE. DO NOT ENTER WHEN CO2 SIREN IS SOUNDING."
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVE PROPER OPERATION OF HEATING ELEMENT SHUTDOWN ON FORWARD GALLEY DONUT FRYER AND DEEP FAT FRYER BANK 7-12 UPON ACTIVATION OF FIXED EXTINGUISER SYSTEM. DONUT FRYER AND BANK 7-12 MAY NOT BE OPERATED UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
REPAIR INOPERATIVE GAYLORD HOOD REMOTE ACTIVATION PULL SWITCH OUTSIDE STARBOARD DOOR TO AFT GALLEY.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
REPAIR BROKEN HINGES TO FIER EXTINGUISHING SYSTEM ACTIVATION PULL BOXES OUTSIDE HOSPITAL EMERGENCY GENERATOR ROOM AND O2/N2 PRODUCER ROOM.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
REPLACE MISSING BELLY STRAPS FOR TWO HALON BOTTLES IN THE JP5 PUMPROOM HALON BANK.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
REPAIR BROKEN EXHAUST VENT DUCT AT FORWARD BULKHEAD IN AFT FLAMMABLE STOREROOM 1-91-6.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVIDE NEW SIREN PLACARDS ON INTERIOR AND EXTERIOR OF O2/N2 PRODUCER ROOM WITH CORRECT TIME DELAY INTERVAL OF 60 SEECONDS.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVIDE PLACARD FOR AFT GALLEY STARBOARD ELECTRICAL PANEL DOOR STATING "DEEP FAT FRYER CIRCUIT BREAKER INSIDE".
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Fire Fighting
Issued 11 April 1994 Resolved
REPAIR OR MODIFY FIXED HALON SYSTEM FUEL CUT OFF FOR AUXILIARY DIESEL GENERATOR IN ENGINEROOM (PRESSURE SWITCH ACTIVATED) TO ENSURE GENERATOR SHUT DOWN WITHIN 60 SECONDS OF HALON SYSTEM ACTIVATION.
Condition: Unknown
Due 11 May 1994
Resolved 2 June 1994
Lifesaving
Issued 16 March 1994 Resolved
PROVIDE CERTIFICATES FORE WIRE ROPE FALLS FOR LIFEBOAT DAVITS AT LIFEBOAT STATIONS 1 THROUGH 10. TO BE COMPLETED PRIOR TO SAILING.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Engineering
Issued 5 November 1993 Resolved
PROVIDE A PQR FOR GARY MUNDT TO WPS SE-S1 DATED 07-24-90 FOR SERVICE ENGINEERING COMPANY TO BE COMPLETED BY 29 NOV 1993.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Lifesaving
Issued 21 October 1993 Resolved
MAKE PROPER FIBERGLASS REPAIR TO CRACKS IN GUNWHALES IN WAY OF LIFTING POINTS FORE AND AFT OF #11 AND #12 LIFEBOATS. REPAIRS TO BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS USING NVIC 2-63 AS A GUIDE.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Engineering
Issued 9 September 1993 Resolved
REMOVE OPENING FROM SIDE OF INDEPENDENT INCINTERATOR DIESEL OIL DAY TANK SOAS TO COMPLY WITH 46 CFR 58.50-10(a)(4). REPAIR WORK MUST COMPLY WITH COASTGUARD APPROVED WELD PROCEEDURES AND TESTS CONDUCTED INT THE PRESENSE OF A MARINE INSPECTOR AS PER 46 CFR 58.50-10(c)(2).
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Engineering
Issued 9 September 1993 Resolved
REMOVE OPENINGS FROM SIDES OF ALL INDEPENDENT DIESEL OIL TANKS. I.E...AMR,ENG. RM. EMERGENCY GEN RM (JP5) SERVICE AREA #3 AND HELO DECK, TOCOMPLY WITH 46 CFR 58.50-10(a)(4). OR PROVIDE CG PLAN APPROVAL ON TANKS CONSTRUCTION OF TANKS WITH SIDE CLEANOUT/INSPECTION OPENINGS.
Condition: Unknown
Due 9 September 1993
Resolved 9 September 1993
Lifesaving
Issued 12 August 1993 Resolved
PROVE PROPER OPERATION OF LIFEBOATS #11 AND #12. #11 HAS A FAULTY ACCUMULATOR AND #12 HAS EVIDENCE OF A CRACKED BLOCK (FUEL IN THE JACKET WATER). VSL IS RESTRICTED TO 2524 PASSENGERS UNTIL THIS ITEM IS CLEAR.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
SUBMIT PLANS TO MODIFY GENERAL STOREROOMS 2-36-4 AND 3-36-4 SO THAT THEY DONOT OPEN INTO A STAIR TOWER. BOTH STOREROOMS CONTAIN LARGE AMOUNTS OF COMBUSTIBLES AND DO NOT MEET THE INTENT OF 46 CFR 72.05-20(F).
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
INSTALL A GENERAL ALARM IWO LOADING RAMP 3RD DECK FRAME 42. WORK MUST BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR WITH APPROVED PLANS.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Documentation
Issued 10 August 1993 Resolved
SUBMIT A CORRECTED AND VERIFIED FIRE CONTROL PLAN FOR SHIP CHECK AND APPROVAL. A LIST OF SPECIFIC DISCREPANCIES IS ON FILE MSO SAN FRANCISCO BAY.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Fire Fighting
Issued 10 August 1993 Resolved
MAKE THE B-0 BULKHEAD BETWEEN COMPARTMENT 3-40-2 AND 3-36-4 COMPLETE FROM DECK TO DECK OR PROVIDE EXEMPTION LETTER FROM COMMANDANT U.S. COAST GUARD (G-MVI).
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Accommodation/Occupational Safety
Issued 24 June 1993 Resolved
REPAIR LEAKS ON CATALYTIC CELLS #5 & #6 IN SERVICE AREA #5.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Fire Fighting
Issued 24 June 1993 Resolved
PROVIDE BREAKGLASS FOR MACHINERY SPACE REMOTE SHUTDOWN.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Electrical
Issued 24 June 1993 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHTS IN THE FOLLOWING AREAS; ICU #1, TREATMENT ROOM BETWEEN ICU 1&2, SITZBATH, OR#1-7,9,10 &12, STAGING AREA(BAY1), LENS LAB, DENTAL LAB, CREWS BERTH "D" AND FEMALE BERTH "F".
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Unknown
Issued 24 June 1993 Resolved
TEST PRESSURE RELIEF VALVES FOR E/R HEAT EXCHANGER AND POTABLE WATER TANK IN SERVICE AREA #3.
Condition: Unknown
Due 23 July 1993
Resolved 23 July 1993
Accommodation/Occupational Safety
Issued 24 June 1993 Resolved
REPAIR LEAKS ON EFFLUENT PUMPS IN SERVICE AREAS #2 & #5.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 24 June 1993 Resolved
RENEW #4C LIFERAFT AT NEXT ROUTINE CHANGE OUT.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Fire Fighting
Issued 24 June 1993 Resolved
REPAIR VENT DAMPER PULL AT FRM 02-692.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Engineering
Issued 24 June 1993 Resolved
PROVIDE ORIGINAL OIL RECORD BOOK.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Electrical
Issued 24 June 1993 Resolved
REPLACE RELIEF VALVES ON EMERGENCY DIESEL AIR RECEIVERS. MAWP IS 435.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Fire Fighting
Issued 24 June 1993 Resolved
PROVIDE HAMMER FOR BREAKGLASS ON AMR REMOTE SHUTDOWN.
Condition: Unknown
Due 1 July 1993
Resolved 1 July 1993
Construction/Loadline
Issued 1 March 1993 Resolved
CONDUCT RANDOM TESTING OF REMAINING SERVICE AREAS TO DETERMINE IF PITTING OF TANKTOPS EXISTS. IF FOUND REPAIRS MUST BE COMPLETED NLT NEXT DRYDOCK. SEE MSO LETTER 16711 DATED 03MAR93.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Construction/Loadline
Issued 1 March 1993 Resolved
MAKE PERMANENT REPAIRS TO PITTED AREAS IN SERVICE AREA 2 & 5 IAW NVIC 7-68 AND MSO LTR. 16711 DATED 03MAR93.
Condition: Unknown
Due 1 March 1993
Resolved 1 March 1993
Electrical
Issued 24 February 1993 Resolved
MAKE REPAIRS TO AND PROVE OPERATION OF THE SHIP SERVICE DIESEL GENERATOR PRIOR TO SAILING.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Engineering
Issued 23 September 1992 Resolved
MAKE PERMANENT REPAIR TO VALVE FOR SUPERHEATER OUTLET PRESSURE GAUGE LINE OUT.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Engineering
Issued 23 September 1992 Resolved
COMPLETE TEMPORARY REPAIRS UTILIZING APPROVED WELD PROCEDURE SPECIFICATION AAA-P4-1 TO REPAIR LEAKING VALVE FOR SUPERHEATER OUTLET PRESSURE GAUGE LINEOUT. UPON COMPLETION OF REPAIR CONTACT THE OFFICE TO HAVE INSPECTOR INSPECT RPR UNDER BOILER LOAD.
Condition: Unknown
Due 23 September 1992
Resolved 23 September 1992
Construction/Loadline
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF BOTH ENGINE ROOM BILGE PUMPS.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Lifesaving
Issued 21 May 1992 Resolved
PROVIDE ATTACHMENT RINGS ON DECK TO ATTACH THE EMBARKATION LADDER FOR LIFERAFT STATION 14.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Construction/Loadline
Issued 21 May 1992 Resolved
PROVIDE SUPPORT FOR THE BILGE PIPING IN THE AMR AFT PORT BILGE POCKET SO THAT THERE IS SUFFICIENT CLEARANCE (AT LEAST 6") BETWEEN THE PIPE AND THE BOTTOM OF THE ROSE BOX.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Unknown
Issued 21 May 1992 Resolved
RENEW TO "AS ORIGINAL" CONDITION THE INTERNAL SURFACE OF THE HYDROPNEUMATICTANK IN SERVICE AREA #3. WELDING TO BE DONE IN ACCORDANCE WITH THE ASME CODE AND 46 CFR 59.10.
Condition: Unknown
Due 31 July 1992
Resolved 31 July 1992
Engineering
Issued 21 May 1992 Resolved
REPAIR STND BOILER MAIN STEAM STOP WARM-UP VALVE STEAM LEAK AT VALVE STEM.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Fire Fighting
Issued 21 May 1992 Resolved
PROVIDE MEANS TO LOCALLY ACCESS AND OPERATE THE FWD FIRE PUMP SEACHEST VENTVALVE.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Fire Fighting
Issued 21 May 1992 Resolved
PROVE THAT MOTOR OPERATED SEACHEST SUCTION AND VENT VALVES FOR FWD FIRE PUMP MAY BE OPERATED LOCALLY, REGARDLESS OF THE REMOTE STATION'S POSITION OF THE TWO VALVES.
Condition: Unknown
Due 4 August 1992
Resolved 4 August 1992
Unknown
Issued 21 May 1992 Resolved
PROVE INSTALLATION OF FIBER OPTIC LAN HARDWARE IS IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Engineering
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF BURNER SEQUENCING ON #1 BOILER.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Fire Fighting
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF STEAM FIRE PUMP OVERSPEED TRIP.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Lifesaving
Issued 21 May 1992 Resolved
SUBMIT PLANS TO SHOW HOW THE VESSEL WILL BE MODIFIED TO ALLOW THE LIFERAFTSAT STATION 1 THROUGH 9 FLOAT FREE OF THE DECK (03) ABOVE.
Condition: Unknown
Due 31 July 1992
Resolved 31 July 1992
Fire Fighting
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF #1 FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Lifesaving
Issued 21 May 1992 Resolved
REPAIR AND CONDUCT A SATISFACTORY RETEST OF THE GENERAL ALARM BELL IN SERVICE AREA 6, STBD SIDE.
Condition: Unknown
Due 31 July 1992
Resolved 31 July 1992
Construction/Loadline
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF STEAM BILGE PUMP OVERSPEED TRIP.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Fire Fighting
Issued 21 May 1992 Resolved
PROVE INSTALLATION OF NEW FIRE DAMPER IS IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Unknown
Issued 21 May 1992 Resolved
PROVE THAT THE 02/N2 PLANT MAY BE EXITED FROM INSIDE THE PLANT, REGARDLESS OF ANY LOCKS ON THE DOORS.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Lifesaving
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF LOW DRUM LEVEL ALARM, #2 BOILER.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Engineering
Issued 21 May 1992 Resolved
PROVIDE PERMANENT MARKING FOR BOILER SAFETY VALVE HAND RELIEVING LEVER, BOTH BOILERS.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Engineering
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION OF #1 FEED PUMP RELIEF VALVE.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Engineering
Issued 21 May 1992 Resolved
PROVE PROPER OPERATION, THROUGH BENCH TEST OR OTHER MEANS, OF #1 EMERGENCY DIESEL STARTING AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 1 July 1992
Resolved 1 July 1992
Construction/Loadline
Issued 22 October 1991 Resolved
PROVIDE APPROVED PLANS FOR NEW STORE ROOM BUILT ON MAIN DECK PORT SIDE.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Fire Fighting
Issued 22 October 1991 Resolved
TEST FORWARD FIRE PUMP AND PROVE IT MEETS REQUIREMENTS OF 756 GALLONS PER MINUTE AS PER MSC LETTER DATED 03 OCTOBER 1991
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Navigation
Issued 30 April 1991 Resolved
PROVE PROPER OPERATION OF RADAR AND ARPA_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Fire Fighting
Issued 30 April 1991 Resolved
REPAIR FIRE SCREEN DOORS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991 Resolved
CONDUCT FIRE AND BOAT DRILLS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Construction/Loadline
Issued 30 April 1991 Resolved
PROVE PROPER OPERATION OF OVSPD TRIP ON STEAM POWERED BALLAST PUMP.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Engineering
Issued 30 April 1991 Resolved
OPEN ALL LARGE BOILER MOUNTS FOR CG INSPECTION (INCLUDES MAIN STEAM STOP, AUX STEAM STOP, ETC.)
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Accommodation/Occupational Safety
Issued 30 April 1991 Resolved
PROVIDE PROOF THAT MSC CREW BERTHING MEETS 46 CFR 72.20 OR HAS WAIVER_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Accommodation/Occupational Safety
Issued 30 April 1991 Resolved
PROVE PROPER OPERATION OF RELIEF VALVES ON #1 S/W FLUSH TANK AND POT WATER TANK.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Accommodation/Occupational Safety
Issued 30 April 1991 Resolved
REPAIR WEATHER TIGHT DOORS ON HELO DECK_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 30 April 1991 Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Navigation
Issued 30 April 1991 Resolved
PROVE PROPER OPERATION OF FATHOMETER RECORDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 10 April 1991 Resolved
(CARRY-OVER FROM CASE MI90010235) WEIGHT TEST ALL LIFEBOAT & DAVIT LAUNCHED LIFERAFTS IAW COMDT WAIVER GRANTING EXTENSION TO DRYDOCK INTERVAL.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Documentation
Issued 10 April 1991 Resolved
(CARRY-OVER FROM CASE MI90010235) RESUBMIT FIRE CONTROL/SAFETY PLAN AFTER REFLECTING CHANGES MADE ONBOARD SINCE LAST REVISION. SUPERCEDED REQ #D7 FROM CASE MI89000809.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Electrical
Issued 10 April 1991 Resolved
(CARRY-OVER FROM CASE MI89000809) PROVIDE COAST GUARD APPROVED PLANS ON AS-INSTALLED ELECTRICAL WIRING/CIRCUITS TO NEW STORE ROOMS/ DECON ROOM AND STBD RAMP.
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Construction/Loadline
Issued 16 December 1990 Resolved
PAINT LOCKER LOCATED MAIN DECK P/S MUST MEET 46 CFR 111.105-43 ALSO ENCLOSESPACE TO A-60 F/F.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 16 December 1990 Resolved
REPLACE 4 BLOW DOWN'S AND 2 SURFACE BLOW FOR VESSEL'S MAIN BOILER PLANT PRESENT VALVES HAVE WELDED BONNET'S.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Accommodation/Occupational Safety
Issued 16 December 1990 Resolved
REPLACE OR REPAIR FIRE DAMPER #5-86-2.
Condition: Unknown
Due 16 December 1990
Resolved 16 December 1990
Engineering
Issued 14 August 1990 Resolved
CROP OUT AND RENEW CRACKED AREA OF DFM TANK #6. CRACKED AREA IS IN BULKHEADBELOW TEMPORARY REPAIR IN WELD BETWEEN FUEL TANK AND VOID 6-69-0. INSERT SHALL BE AT LEAST 18 INCHES IN LENGTH, WITH RADIUS'ED CORNERS.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 14 August 1990 Resolved
COMPLETE TEMPORARY REPAIRS TO CRACKED WELDS IN #6 PORT DFM TANK BY BACK GOUGING TO EXISTING REPAIRS AND THEN WELDING ON INSIDE OF TANK.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 14 August 1990 Resolved
MAKE TEMPORARY REPAIR TO LEAKING WELD SEAM IN #6 PORT DFM TANK BY GOUGING OUT EXISTING CRACK AND THEN COMPLETING A FULL PENETRATING WELD.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 14 August 1990 Resolved
UPON COMPLETION OF ITEMS 1 & 2 CONDUCT SAT AIR TEST OF TANK.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 13 July 1990 Resolved
SUBMIT PLANS FOR, AND COMPLETE PERMANENT REPAIRS TO AREAS ERRONEOUSLY DRIL-LED THROUGH THE MAIN DECK PLATING INTO DFM TANK #6.
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Lifesaving
Issued 26 March 1990 Resolved
WEIGHT TEST ALL LIFEBOAT & DAVIT LAUNCHED LIFERAFTS IAW COMD'T WAIVER GRANTING EXTENSION TO DDX.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Fire Fighting
Issued 26 March 1990 Resolved
PRIOR TO LANDING HELICOPTERS ON FLIGHT DECK OR GETTING UNDERWAY PROVE OPERATION OF STBD FLIGHT DECK FOAM MONITOR TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Lifesaving
Issued 26 March 1990 Resolved
ENSURE PROPER OPERATION OF ALL LIMIT SWITCHES. DURING COI THEY WERE OPENED FOR VISUAL INPECTION BUT BOATS WERE NOT LOWERED.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Documentation
Issued 26 March 1990 Resolved
PROVIDE COPIES OF GFS FIRE SYSTEMS SERVICING (INCLUDING DETECTION SYSTEM) AND ELEVATOR SERVICING REPORT.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Documentation
Issued 26 March 1990 Resolved
RESUBMIT FIRE CONTOL/SAFETY PLAN AFTER REFLECTING CHANGES MADE O/B SINCE LAST REVISION.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Lifesaving
Issued 26 March 1990 Resolved
WHEN FULL CREW IS ABOARD AND PRIOR TO GETTING UNDERWAY CONDUCT A SATISFACTORY FIRE AND BOAT DRILL WITNESSED BY CG INSPECTOR.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Accommodation/Occupational Safety
Issued 1 May 1989 Resolved
REPAIR LEAKING RAW SEWAGE PUMP IN SERVICE AREA # 1.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Documentation
Issued 1 May 1989 Resolved
PROVIDE AND POST APPROVED, UPDATE PERMANENT STABILITY LETTER AND TRIM/ STABILITY BOOK.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Electrical
Issued 1 May 1989 Resolved
ACOMPLETE INSTALLATION OR PROPOSED REMOVAL OF ACTUATOR WIRING IN HALON RM.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Construction/Loadline
Issued 1 May 1989 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN OVERHEAD OF N2/O2 ROOOM.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Accommodation/Occupational Safety
Issued 1 May 1989 Resolved
REVEIW AND CLEAR COMMENTS OF COMDT COAST GUARD LETTERS: #E-90296, DTD. 07JUN89; #M-80716, DTD. 25JUL88; #M80702, DTD.27JUL88; #E2-81229, DTD. 22NOV88 AND #E-80611,DTD. 08SEP88.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Electrical
Issued 1 May 1989 Resolved
PROVIDE COAST GUARD APPROVED PLANS ON AS INSTALLED ELECTRICAL WIRING/ CIRCUITS TO NEW STORE ROOMS/DECON ROOM AND STB RAMP.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Fire Fighting
Issued 1 May 1989 Resolved
PROVIDE COAST GUARD APPROVED STRUCTURAL FIRE PROTECTION PLANS FOR NEW MODIFICATION FO STORE ROOMS AND STB RAMP.
Condition: Unknown
Due 1 May 1989
Resolved 1 May 1989
Electrical
Issued 27 October 1988 Resolved
PROVIDE USCG APPROVED ELECTRICAL PLANS FOR THE CATSCAN ROOM INSTALLATION.
Condition: Unknown
Due 27 October 1988
Resolved 27 October 1988
Construction/Loadline
Issued 2 September 1988 Resolved
PORVIDE APPROVED PLANS FOR ALTERATIONTO HYPO-CHLORITE SYSTEM. ALTERATION ISA FRAINFROM HYDROGEN VENT LIN WHICH IS EXTENDED TO BILGES.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Construction/Loadline
Issued 2 September 1988 Resolved
OPEN AND DRAIN BALLAST TANK WHERE 3/4" HYDROGEN VENT LINE FROM HYPO- CHLORITE SYSTEM PASSES THROUGH. LINE SHALL BE TRACED TO ITS END POINT.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Construction/Loadline
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE STRUCTURAL MODIFICATIONS COMPLETED IN BALLAST TANKS #2 AND #6.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Construction/Loadline
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE BALLAST TANK OVERFLOW PIPING MODIFICATIONS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE FIXED CO2 SYSTEM INSTALLATION SERVING THE ENGINE ROOM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 8 April 1988 Resolved
PROVIDED USCG APPROVED PLANS FOR THE HALON SYSTEM INSTALLATION SERVING THE 02N2 COMPRESSOR ROOM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Construction/Loadline
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE CATSCAN ROOM INSTALLATION. PLANS ARE TO INCLUDE STRUCTURAL MODIFICATIONS AND ELECTRICAL DRAWINGS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Construction/Loadline
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR INSTALLATION OF THE TWO NEW CLASS III WATERTIGHT DOORS. PLANS ARE TO INCLUDE STRUCTURAL MODIFICATIONS AND ELECTRICAL DRAWINGS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Electrical
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE SECURITY LIGHTING.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Construction/Loadline
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE HALON ROOM 4-54-1 STRUCTURAL MODIFICATIONS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE HALON SYSTEM INSTALLATION SERVING SERVICE AREA #3.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 8 April 1988 Resolved
RECHARGE TWO OF THE NEWLY INSTALLED FIXED HALON SYSTEM BOTTLES TO FULL CAPACITY.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
INSTALL REMOTE SHUTDOWN FOR NEWLY INSTALLED FUEL OIL PURIFIER.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE LUBE OIL AND FUEL OIL PURIFIER INSTALLATIONS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE AUXILIARY COOLING SYSTEM/HEAT EXCHANGER INSTALLATION.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Electrical
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE INSTALLATION OF THE RADIO COMMUNICATIONS SYSTEM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Electrical
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE INSTALLATION OF ADDITIONAL ELECTRICAL CIRCUITS AND RECEPTICLES.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Lifesaving
Issued 8 April 1988 Resolved
CONDUCT WEIGHT TEST OF LIFEBOATS #11 AND #12 AS REQUIRED BY 46 CFR 71.25-15
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Accommodation/Occupational Safety
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE INSTALLATION OF THE POTABLE WATER HYPO-CHLORITE SYSTEM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE INSTALLATION OF THE S/W CHLORINATOR SYSTEM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE D/G SALT WATER COOLING SYSTEM MODIFICATIONS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE INSTALLATION OF THE SALT WATER FLUSHINGSYSTEM.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988 Resolved
INSTALL ADDITIONAL STIFFENERS OR REPLACE THE WINDOWS IN THE ENGINE ROOM CONTROL CONSOLE ENCLOSURE WITH THICKER MATERIAL.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Lifesaving
Issued 8 April 1988 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT DAVIT #12 TO PROVE EXCESSIVE PLAY IN BREAK ASSEMBLY HAS BEEN CORRECTED. ADDITIONAL WEIGHT TEST NOT REQUIRED.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 8 April 1988 Resolved
PERMANENTLY POST OPERATING INSTRUCTIONS DETAILING RELEASE AND ALTERNATE METHOD OF RELEASE FOR THE HALON SYSTEMS SERVING THE 02N2 COMPRESSOR ROOM AND SERVICE AREA #3 AND THE CO2 SYSTEM SERVING THE E.R. CONTROL ROOM. INSTRUCTIONS MUST BE POSTED AT EACH ENTRANCE TO THE PROTECTED SPACE.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 8 April 1988 Resolved
PROVIDE USCG APPROVED PLANS FOR THE AFFF PIPING MODIFICATIONS ON THE 04 LEVEL.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Electrical
Issued 17 January 1988 Resolved
REPLACE MISSING EXPLOSION PROOF GLASS FICTURE IN PORT 01 DECK FLAMMABLE STORES.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Fire Fighting
Issued 17 January 1988 Resolved
PROVIDE PROPER STORAGE FOR 5 GAL. AFFF CONTAINERS ON FLIGHT DECK.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
INSTALL DRAINS ON 01 EXTERIOR DECK AGAINST HOUSE SO STANDING WATER WILL NOTCOLLECT IN FRONT OF HOUSE ACCESS DOORS. DRAINS SHALL BE PLACED AT DOOR # 01-84-1, 01-100-5, 01-80-1.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
PROVIDE ANSI-13 CERTIFICATION FOR #10 CARGO ELEVATOR OR REMOVE.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
REPAIR GAYLORD CLOSER 01-108-1 IN AFT MESS DECK.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Construction/Loadline
Issued 17 January 1988 Resolved
ALL FSD'S WHICH ARE LOCATED IN MAIN VERTICAL ZONES AND ARE CLASS "A" RATED SHALL HAVE A HYDRAULIC CLOSING DEVICE ON BOTH DOORS AND A SEQUENCIAL CLOSING DEVICE TO ALLOW THE DOOR TO SECURE PROPERLY. DOORS #90, 126, 114, 105, 107, 122, 121, 132, 133, 140, 139, 95, 113, 137.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
PROVIDE SERVICE REPORT FROM FRPAIRS OF ELEVATORS. REPAIR AND PROVE SATISFACTORY OPERATION OF VISUAL ALARMS ON ALARM PANEL BOARD IN AMR.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Electrical
Issued 17 January 1988 Resolved
REPAIR AND TEST HI J/W ALARM ON AUX DIESEL GENERATOR IN E/R
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
PROVIDE SOLAS BOAT COVER FOR LIFEBOAT #9.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
COMPLETELY REBUILD LIFEBOATS #11 & 12. FLOATATION FOAM IS SATURATED WITH WATER. FRP IS CRACKED ON PORT AND STBD SEATS. HULL IS CRACKED PORT AND STBDFWD AND AFT WHERE GRIPES CINCH BOAT IN DAVIT. ENGINE COMPARTMENT LEAKS WATER. PROVISION COMPARTMENTS ARE NOT WATERTIGHT.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
THE CURRENT CERTIFIED LIFE RAFT CAPACITY ABOARD THE VESSEL IS 100. THE SHALL NOT CARRY MORE THAN 100 TOTAL PERSONS UNTIL THE REMAINDER OF LIFE RAFTS ARE SERVICED AND REPLACED ABOARD THE VESSEL.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Fire Fighting
Issued 17 January 1988 Resolved
PRIOR TO LEAVING PORTLAND SHIPYARD THE S/S AFFF PORTABLE EXT. SHALL BE IDENTIFIED AS TO WHICH SPACES THEY ARE SANITARILY NECESSARY AND THE REMAINDER REMOVED. THE VESSEL SHALL PROVIDE APPROVED PLANS FROM G-MVI-3 FORTHE APPROVAL OF THE LOCATION OF THE EXTINGUISHERS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Construction/Loadline
Issued 17 January 1988 Resolved
ALL HOOKS AND EYELETS WHICH PROVIDE FOR SECURING FIRE SCREEN DOORS OPEN SHALL BE REMOVED OR A WAIVER PROVIDED. THE PADS SHALL NOT BE REINSTALLED ORTHE DOOR HELD BACK IN MANNER UNTIL THE WAIVER LETTER HAS BEEN PROVIDED WITHAPPROVED PLANS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Fire Fighting
Issued 17 January 1988 Resolved
REPAIR OR REPLACE GENERAL ALARM BELL 01-53-6.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Fire Fighting
Issued 17 January 1988 Resolved
REPAIR OR REPLACE RELIEF VALVE FOR TURBINE FIRE PUMP.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
ALL LIFE RAFT DAVITS SHALL BE WEIGHT TESTED.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
LIFEBOAT DAVITS #2,4,6,8,10,11, & 12 SHALL BE WEIGHT TESTED AND LIFEBOATS SHALL BE RELEASED AND OPERATED IN WATER AS REQUIRED BY ANNUAL COI.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Construction/Loadline
Issued 17 January 1988 Resolved
REPAIR OR REPLACE DOORS FOR MEDICAL STORE RM 02-78-0 AND 02-69-1. DOORS WILL NOT CLOSE PROPERLY AND CRASHBAR IS DAMAGED.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Fire Fighting
Issued 17 January 1988 Resolved
REPAIR THE FOLLOWING LEAKING FIRE STATIONS: #6, 15, 140, 31, 65, 118, 122, 123.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
THE VESSEL IS LIMITED TO CARRYING 2100 TOTAL PERSONS. 46 CFR 75.10-10(B). IN ADDITION TO ANY OTHER REQUIRED EQUIPMENT, APPROVED LIFE RAFTS WITH AGGREGATE CAPACITY OF AT LEAST 25 PERCENT OF THE PERSONS ON BOARD SHALL BE PROVIDED.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
46 CFR 78.47-47 PROVIDE LAMINATED STATEROOM NOTICES IN ALL STATEROOMS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
PROVIDE WRITTEN PROCEDURE FOR MOVING PATIENTS DURING ABANDONING SHIP. POST PROCEDURE IN ALL WARDS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
PROVIDE A-15 CERTIFICATION FROM MANUFACTURER WITH PURCHASE ORDER OR REMOVE.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
CONDUCT ANNUAL BOILER HYDRO ON BOTH BOILERS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
REPAIR AND TEST FRESH WATER RELIEF VALVE.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
REPAIR AND TEST HOT FRESH WATER TANK RELIEF VALVE.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
TEST DC HEATER RELIEF VALVE.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
PLACE 'NO HOT WORK' WARNING ON L/O GRAVITY TANK.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
PLACE 'NO HOT WORD' WARNING ON DFM WING STORAGE TANKS (PORT AND STBD)IN E/R
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
REPLACE LIGHT FOR PORT BOILER DRUM GAGE GLASS
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Electrical
Issued 17 January 1988 Resolved
INSTALL GUARDS ON EXPLOSION PROOF LIGHTS IN EMERGENCY BATTERY ROOM.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Engineering
Issued 17 January 1988 Resolved
REPLACE TWO EXPANSION JOINTS, ONE IN EACH CIRC. PUMP SUCTION LINE.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
REPLACE MISSING CERTIFICATION PLATE ON DAVIT #2.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
REPAIR ALL MANUAL PULL VENTS LOCATED THROUGHOUT INDIVIDUAL FIRE ZONES AND PROVE OPERATION.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
2192 ADULT & 226 CHILDS L/P HAVE BEEN STAMPED & PASSED. VESSEL'S PRIOR CERTWAS FOR 2466 ADULT & 247 CHILDS LIFE PRESERVERS. VESSEL IS LIMITED TO CARRYING A TOTAL 2100 PERSONS BY 46CFR75.10-15(B). IF VESSEL COMPLIES WITH PRIMARY & SECONDARY L/S THEN 274 ADULT & 21 CHILDS L/P SHALL BE PROVIDED.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
INSTALL DONNING PLACARDS FOR LIFE JACKETS ON ALL STOWAGE LOCKERS AND MESS DECKS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Construction/Loadline
Issued 17 January 1988 Resolved
REMOVE PLIABLE SEALANT FROM PANEL L602 ON 01 LEVEL MAIN LAB. ALL ILLEGAL SPONGE AND PLIABLE SEALANT SHALL BE IDENTIFIED AND REMOVED FROM WIRE RUNS. MATERIAL SHALL BE REPLACED WITH CG APPROVED MATERIAL. SPONGE HAS BEEN IDENTIFIED ON 01 LEVEL AND IN VARIOUS OTHER LOCATIONS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Accommodation/Occupational Safety
Issued 17 January 1988 Resolved
REPLACE HANDLE ON GAYLORD VENT IN AFT GALLEY.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Fire Fighting
Issued 17 January 1988 Resolved
REPAIR LEAKING FLANGE IN FIREMAIN ISOLATION VALVE FF-84 IN 02 GENERATION ROOM.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
INSTALL CLEATS FOR LIFEBOAT PAINTERS AND LIFE RAFT PAINTERS.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Lifesaving
Issued 17 January 1988 Resolved
MOUNT ALL FLOAT FREE RING BUOY WATERLIGHTS PROPERLY.
Condition: Unknown
Due 17 January 1988
Resolved 17 January 1988
Unknown
Issued 4 July 1987 Resolved
EFFECT PERMANENT REPAIRS TO #1 BOILER, AFT HEADER DRAIN LINE BETWEEN HEADERAND STOP VALVE.
Condition: Unknown
Due 4 July 1987
Resolved 4 July 1987

Casualty record · 9

26 September 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2512201
17 August 2017Routine · role: Involved in a Marine Casualty · activity 6256897
12 April 2018Routine · role: Involved in a Marine Casualty · activity 6685314
29 June 2020Routine · role: Involved in a Marine Casualty · activity 7021147
6 July 2020Routine · role: Involved in a Marine Casualty · activity 7003131
29 April 2021Routine · role: Involved in a Marine Casualty · activity 7214472
24 June 2022Routine · role: Involved in a Marine Casualty · activity 7540235
7 January 2024Routine · role: Involved in a Marine Casualty · activity 7847448
26 May 2024Routine · role: Involved in a Marine Casualty · activity 7924799
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.