Records from 1982 to 1991. Most recent: inspection, 16 September 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 15 May 1991
Resolved
PROVIDE EVIDENCE THAT A TOTAL OF 129 CG APPROVED OCEAN SERVICE LIFE PRESERVERS ARE ON BOARD. VSL IS LIMITED TO THE CARRIAGE OF 85 PERSONS UNTIL COMPLIANCE. EVIDENCE PROVIDED MAY INCLUDE A STATEMENT FRO OIM AND ORRECEIPTS.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Lifesaving
Issued 23 April 1991
Resolved
PROVIDE CG APPROVED RING BUOYS AT THE FOLLOWING STATIONS; P AND S QUICK RELEASE STATIONS, MAIN DECK STBD SIDE CHISSON #5 MAIN DECK PORT QUARTER.
Condition: Unknown
Due 4 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 23 April 1991
Resolved
PROVIDE O2/EXPLOSIVE METER FOR FIREMANS SUITS.
Condition: Unknown
Due 4 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 23 April 1991
Resolved
SUBMIT EVIDENCE TO COMMANDANT G-MFR TO AMEND CERT. OF FINANCIAL RESPONSIBILITY TO REFLECT WESTERNS COMPANY AS OWNER.
Condition: Unknown
Due 4 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 23 April 1991
Resolved
PROVIDE THE FOLLOWING LICENSED CREW COMPLEMENT ABOARD THE VESSEL: 1 OFFSHORE INSTALLTAION MANAGER, 1 BARGE SUPERVISOR, 2 BALLAST CONTROL OPERATORS.
Condition: Unknown
Due 4 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 23 April 1991
Resolved
PROVIDE DAVIT LAUNCHED LIFERAFTS TO ACCOMODATE THE TOTAL NUMBER OF PERSONS ALLOWED ABOARD AS AUTHORIZED ON THE CERT. OF INSPECTION.
Condition: Unknown
Due 1 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 23 April 1991
Resolved
REPLACE APPROVED FIRE EXTINGUISHERS IN BOTH LIFEBOATS.
Condition: Unknown
Due 4 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 21 May 1990
Resolved
SUBMIT REVISIONS TO OPERATING MANUAL TO MARINE SAFETY CENTER PER MSO PORT ARTHUR LTR OF 21 MAY 90.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Electrical
Issued 5 December 1989
Resolved
CONDUCT OPERATIONAL TEST OF AUTOMATIC BUS TRANSFER.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Lifesaving
Issued 30 November 1988
Resolved
CONDUCT FIRE AND BOAT DRILL WHEN VESSEL IS FULLY MANNED AND NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Lifesaving
Issued 30 November 1988
Resolved
PROVIDE INFLATABLE LIFERAFTS ON STATION. VESSEL'S CREW REDUCED TO 12, AND IN STACKED CONDITION. VESSEL'S MANNING REDUCED TO 64 UNTIL REQUIREMENT IS CLEARED.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Engineering
Issued 30 November 1988
Resolved
CONDUCT TEST OF PORT PROPULSION ASSIST.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Engineering
Issued 30 November 1988
Resolved
CONDUCT TEST OF EMERGENCY GENERATOR OVERSPEED TRIP AND LOW OIL PRESSURE SHUTDOWN.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Fire Fighting
Issued 30 November 1988
Resolved
PROVIDE COPY OF FIRE FIGHTING FOAM ANALYSIS.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
ALL LADDER AND PLATFORM REPAIRS TO INCLUDE PLATFORM GRATINGS, HAND RAILS, AND RUNGS.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
CONDUCT UNDERWATER EXAMINATION OF PONTOON HULLS, SEACHEST, AND PROPELLERS AND RECORD WITH UNDERWATER TELEVISION AS PER INSPECTION PLAN DATED 19 AUG 1988.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO NO. 5 CAISSON TO THE INSET AREA BETWEEN 57' - 63' LEVEL. REPAIRS TO INCLUDE SIDE SHELL AND INTERNAL STRUCTURAL MEMBERS.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO NO. 6 CAISSON TO THE INSET AREA BETWEEN 58' - 65'LEVEL. REPAIRS TO INCLUDE ANY DAMAGED SIDE SHELL AND INTERNAL STRUCTURAL MEMBERS.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO DIAGONAL BRACE (VERTICAL BRACE) BETWEEN STAR- BOARD CAISSONS NO. 4 AND NO. 5 AT APPROXIMATELY 60' LEVEL.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO DIAGONAL VERTICAL BRACE BETWEEN STARBOARD CAISSONS NO. 5 AND NO. 6 AT THE 60' - 65' LEVEL.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO THE VERTICAL DIAGONAL BETWEEN PORT CAISSONS NO. 2 AND NO. 3 AT THE 60' LEVEL.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Lifesaving
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO ALL CAISSON ESCAPE LADDERS AND LADDER PLATFORMS.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 2 November 1988
Resolved
MAKE PERMANENT REPAIRS TO "K" JOINT ACCESS PLATFORMS LOCATED UNDER UPPER HULL.
Condition: Unknown
Due 2 November 1988
Resolved 2 November 1988
Construction/Loadline
Issued 9 December 1987
Resolved
REPAIR/REPLACE ALL SPRUNG AND/OR WASTED WATERTIGHT/WEATHERTIGHT VENT.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Navigation
Issued 9 December 1987
Resolved
REPLACE CRACKED OBSTRUCTION LIGHT COVER/LENS LOCATED FORWARD PORT CORNER.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Lifesaving
Issued 9 December 1987
Resolved
PROVIDE TWO MORE SERVICE & PROJECTILES FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Lifesaving
Issued 9 December 1987
Resolved
PROVIDE ON BOARD A SUFFICIENT QUANTITY OF APPROVED PACKAGED WATER TO REPLACTEMPORARY INSTALLATION OF JUG WATER IN AFT LIFEBOAT. TEST.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Documentation
Issued 9 December 1987
Resolved
PROVIDE THIS OFFICE WITH A CURRENT COPY OF YOUR SOLAS EXEMTION CERTIFICATE OR TELEPHONY/TELEGRAPH CERTIFICATE AND A COPY OF YOUR CURRENT AFF FOAM TEST
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Navigation
Issued 9 December 1987
Resolved
PROVIDE GUARDS FOR HELIDECK PERIMETER LIGHTS OR REPLACE GLASS GLOBES WITH PLASTIC ONES.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Accommodation/Occupational Safety
Issued 9 December 1987
Resolved
REPAIR OR MAKE PHYSICALLY UNUSABLE/INACCESSIBLE THE TWO(2) EMERGENCY ESCAPELADDERS.APPROPIATELY DESIGNATE THE TWO (2) REMAINING ACCESSES EMERGENCY ESCAPE TO WATER AND DESIGNATE THIS ON YOUR FIRE AND SAFETY PLAN.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Electrical
Issued 9 December 1987
Resolved
MAKE OPERABLE THE OVERSPEED SHUTDOWN, LOW LUBE OIL PRESSURE ALARM, AND HIGHWATER JACKET TEMPERATURE ALARM ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Electrical
Issued 9 December 1987
Resolved
REPLACE ALL LIGHTS AND OTHER ELECTRICAL FITTINGS WITH APPLIANCES MEETING THE EXPLOSION PROOF STANDARDS OF UL,CSA,FM, LOCATED SFT OUTSIDE ALL DOORS WINDOWS, VENTS ETC. ON PERIMETER OF DRILL FLOOR (CLASS1 DIV1 AREA)
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Electrical
Issued 9 December 1987
Resolved
INSTALL EYS FITTINGS ON FOLLOWING ELECTRICAL CABLES IN SHAKEY AREA: 2 ON JUNCTION BOX ON BULKHEAD BETWEEN CYCLONE AND DEGASSER UNITS, 2 ON JUNCTION BOX BY TELEPHONE, 2 ON JUNCTION BOX BY CAMERA(UPPER LEVEL)1 ON JUNCTION BOXOVER MUD TROUGH AFT AREA OF SPACE OVER POOL AREA.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Electrical
Issued 9 December 1987
Resolved
PROPERLY SUPPORT THE TWO LARGE ELECTRICAL CABLES RUNNING ALONG OVERHEAD IN FWD AREA.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Construction/Loadline
Issued 9 December 1987
Resolved
REPAIR PACKING ON BALLAST PUMP (BROKEN STUD BOLT) IN STBD PUMP RM.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Electrical
Issued 9 December 1987
Resolved
REPAIR INOPERATIVE PORT THRUSTER COLUMN ELEVATOR
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Accommodation/Occupational Safety
Issued 9 December 1987
Resolved
REPLACE 140 PSI RELIEF VALVES ON ALL HOT WATER HEATERS WITH ONES SET AT NOTABOVE 100 PSI AND 210 DEGREES F.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Accommodation/Occupational Safety
Issued 9 December 1987
Resolved
PROVIDE EYE WASH EQUIPMENT PER 33CFR 142 IN ALL MUD AREAS (DRILL FLOOR, MUDPITS AND SHAKER AREA 33CFR 142.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Construction/Loadline
Issued 17 April 1987
Resolved
MAKE THE LOW SEA SUCTION VALVE FOR THE NO. ONE SEA-WATER PUMP OPERATIONAL.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Fire Fighting
Issued 17 April 1987
Resolved
PROVIDE ONBOARD A COPY OF LATEST FOAM FIREFIGHTING REPORT.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Construction/Loadline
Issued 17 April 1987
Resolved
REMOVE OR REPAIR LOCAL CONTROLS FOR THE PNUEMATIC CONTROLS OF THE 27P AND 29P VALVES IN THE PORT PUMP RM.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Electrical
Issued 17 April 1987
Resolved
REPAIR ELECTRICAL JURY RIG TO NO. ONE SEA-WATER PUMP IN THE PORT PUMP RM.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Deck/Cargo
Issued 20 December 1986
Resolved
HYDROSTATICALLY TEST FUEL HOSE, HOSE FOR GAS/OIL SERVICE AND MARK HOSES PER33 CFR 155.800.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
MAKE OPERABLE THE MACHINERY SPACE INTAKE VENTS (OPEN-CLOSE).
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Electrical
Issued 20 December 1986
Resolved
REPAIR/RENEW BROKEN OR MISSING BATTERY BOX VENTS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
MAKE OPERABLE VALVES 27S AND 29S IN STBD PUMPROOM.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
MAKE PROPER ELECTRICAL CONNECTIONS TO MAIN SALT WATER HIGH AND LOW SUCTION VALVES, PORT PUMP ROOM. ALSO MAKE OPERABLE VALVES 27P AND 29P IN PORT PUMP ROOM.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
MAKE PERMANENT REPAIRS TO THE CENTER COLUMN #5 AT THE 61' DRAFT 25SQ.FT. OFPLATE RENEWAL AND VERTICAL LONGS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Navigation
Issued 20 December 1986
Resolved
UPDATE REQUIRED NAVIGATIONAL CHARTS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Documentation
Issued 20 December 1986
Resolved
PROVIDE ONBOARD A VALID SAFETY EQUIPMENT CERTIFICATE. (SOLAS)
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
RENEW DRILL WATER TO SALT WATER CROSS CONNECTION LINE IN PORT PUMP ROOM.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Engineering
Issued 20 December 1986
Resolved
PROVIDE INFORMATION TO THE [name withheld] THE TAILSHAFTS WERE LAST PULLED AND INSPECTION RESULTS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Navigation
Issued 20 December 1986
Resolved
MAKE OPERATIONAL THE GYRO COMPASS AND RADAR.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Fire Fighting
Issued 20 December 1986
Resolved
CONDUCT FIRE AND BOAT DRILL 48 HOURS PRIOR TO COMMENCING NEXT DRILLING OPERATIONS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Accommodation/Occupational Safety
Issued 20 December 1986
Resolved
REMOVE FIXED ACETYLENE AND OXYGEN SYSTEM OR PROVIDE APPROVED INSTALLATION DATA AND PERIODIC TEST RESULTS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Navigation
Issued 20 December 1986
Resolved
REPAINT LOADLINE MARKS ON BOTH CENTER COLUMNS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Fire Fighting
Issued 20 December 1986
Resolved
HYDROSTATIC TEST THE TWO (02) SPARE SCBA BOTTLES FOR THE FIREMAN OUTFITS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Lifesaving
Issued 20 December 1986
Resolved
REFILL AIR BOTTLES FOR #1 LIFEBOAT.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Deck/Cargo
Issued 20 December 1986
Resolved
RENEW VALVE HAND WHEEL AT TUGGER WINCH LOCATED FORWARD OF PIPE RACK. ALSO RENEW OR REMOVE AIR SUPPLY PIPE TO AIR HOSE CONNECTION IN WAY OF WINCH.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Navigation
Issued 20 December 1986
Resolved
PROVIDE ONBOARD MANEURVERING INFORMATION.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Electrical
Issued 20 December 1986
Resolved
REPLACE THE FLEXIBLE COUPLINGS THAT ARE CRACKED ON #2 AND 3 EMD DIESEL ENGINES IN WAY OF THE HEAT EXCHANGER.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
MAKE PERMANENT REPAIRS TO THE VERTICAL DIAGONALS AT THE 63' DRAFT BETWEEN COLUMN 4 AND 5, 5 AND 6.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 20 December 1986
Resolved
REPLACE THE SPOOL PIECE ON THE SALT WATER SEA CHEST SUCTION LINE, SUCTION SIDE OF THE "Y" PIECE, IN STBD PUMP ROOM.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Construction/Loadline
Issued 24 September 1986
Resolved
PROVIDE MANUFACTURER DATA AND DESCRIPTION (SKETCH IF POSSIBLE SHOWING ALL PARTS) OF SEA VALVES INSTALLED IN PUMP RMS.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Construction/Loadline
Issued 24 September 1986
Resolved
PORVIDE COPY OF ULTRASONIC GAGING RPT. TO OUR OFFICE. ORIGINAL PLATE THICKNESS DATE SHOULD ALSO BE SUBMITTED WITH THIS RPT.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Construction/Loadline
Issued 24 September 1986
Resolved
REPAIR HIGH SEA CHEST VALVE (VALVE CAN'T OPEN OR CLOSE ALL THE WAY). PROVEOPERATION OF VALVE TO MARINE INSPECTOR. VALVE LOCATED IN PORT PUMP RM.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Construction/Loadline
Issued 24 September 1986
Resolved
REPAIR SEA WATER PUMP NO. 1P IN THE PORT PUMP RM.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Construction/Loadline
Issued 24 September 1986
Resolved
REPAIR MANUAL CONTROL FOR HIGH SEA CHEST VALVE IN STBVS PUMP RM. PROBLEMS: (1) SLEEVE CRACKED ON MANUAL CONTROL; (2) VAVLE WON'T OPEN COMPLETELY WITH MANUAL WHEEL; (3) MANUAL WHEEL RUBS AGAINST NEARBY ANGLE.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Unknown
Issued 11 August 1986
Resolved
CONDUCT A VISUAL INSPECTION OF THE SEACHESTS AND VALVE OPERATION, PROPELLERS AND SHAFTING.
Condition: Unknown
Due 11 August 1986
Resolved 11 August 1986
Construction/Loadline
Issued 11 August 1986
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED SUPPORT MEMBERS ON THE AFT SIDE OF NUMBERSIX CAISSON.
Condition: Unknown
Due 11 August 1986
Resolved 11 August 1986
Construction/Loadline
Issued 11 August 1986
Resolved
CONDUCT A VISUAL INSPECTION ON THE BOTTOM, SIDES AND TOP OF LOWER HULLS.
Condition: Unknown
Due 11 August 1986
Resolved 11 August 1986
Construction/Loadline
Issued 11 August 1986
Resolved
CONDUCT AN ULTRASONIC TESTING FOR THICKNESS GAUGING ON LOWER HULLS.
Condition: Unknown
Due 11 August 1986
Resolved 11 August 1986
Unknown
Issued 7 July 1986
Resolved
MAKE THE UNIT AVAILABLE FOR DRYDOCK EXAMINATION OR SPECIAL UNDERWATER EXAM IN LIEU OF DRYDOCKING. A PROPOSAL MEETING THE REQUIREMENTS OF 46 CFR 107.265 MUST BE SUBMITTED TO THE COGNIZANT OFFICER IN CHARGE OF MARINE INSPECTION 30 DAYS IN ADVANCE IF A SPECIAL UNDERWATER EXAM IS PLANNED.
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986
Unknown
Issued 28 May 1986
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED STARBOARD DIAGONAL SUPPORT MEMBERS. REPAIRS MUST BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE OF MARINE INSPECTION.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Electrical
Issued 5 December 1985
Resolved
PROVIDE EYS PROTECTION FOR JUNCTION BOX LOCATED BEHIND CAMERA CONTROL IN DRILLERS SHACK.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 5 December 1985
Resolved
REPLACE DOOR CLOSURE; PROPERLY CAP OFF JUNCTION BOX WIRES; PROVIDE EYS PROTECTION FOR 3 LEVEL INDICATORS IN MUD PITS.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Lifesaving
Issued 5 December 1985
Resolved
PROVIDE SERVICING CERTIFICATES (COPY) FOR #1, 4 & 7 LIFERAFTS.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Fire Fighting
Issued 5 December 1985
Resolved
PROVIDE TWO (2) FIRE HOSES (2 1/2 X 50' LENGTHS) ABOARD FOR HYDRANT STATIONS AS APROPRIATE.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Navigation
Issued 5 December 1985
Resolved
INSTALL CORRECT BULBS FOR RUNNING LIGHTS AS NECESSARY.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 7 February 1985
Resolved
REMOVE THE DEAD END WIRE AND PLACE THE COVER ON THE ELECTRICAL BOX IN THE STOREROOM. 46CFR111.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Engineering
Issued 7 February 1985
Resolved
REPAIR THE REVERSE POWER RELAY ON THE NO2 MAIN GENERATOR. 46CFR107.231.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Navigation
Issued 7 February 1985
Resolved
PRIOR TO NEXT COMPLETED RIG MOVE REPAINT THE VESSEL'S LOAD LINE MARKS. 46CFR108.661
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985
Resolved
MAKE OPERATIVE THE GENERAL BELLS IN THE QUARTERS (NEAR ROOM 114 AND 204), AND IN THE MOTOR ROOM; LABEL THE GENERAL ALARM BELLS ON THE DRILL FLOOR 46CFR113.25.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Engineering
Issued 7 February 1985
Resolved
MAKE AVAILABLE FOR INSPECTION THE HIGH PRESSURE TENSIONING BOTTLES, DRILL FLOOR AIR RECEIVER, AND ANCHOR WINCH AIR RECEIVERS. 46CFR61.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
INSTALL DRUM GUARDS ON THE DECK WINCHES. 46CFR107.231
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
PROVIDE AN OPERATING INDICATOR LIGHT ON THE HELICOPTER FUELING PUMP. 46CFR108.239
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Navigation
Issued 7 February 1985
Resolved
PROVIDE ABOARD THE RIG THE CURRENT SOLAS EQUIPMENT CERTIFICATE SOLAS SAFETYRADIO TELEPHONE CERTIFICATE AND FCC EXEMPTION CERTIFICATE. 46CFR107.413.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985
Resolved
SUBMIT TO THE [name withheld] A COPY OF FOAM ANALYSIS 46CFR108.431.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985
Resolved
PROVIDE ABOARD LIFEBOAT NUMBER ONE AIR BOTTLE CYLINDER (FRESH AIR BOTTLE) 46CFR109.21.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985
Resolved
PROVIDE EMERGENCY LIGHTS TO FOCUS ON THE WATER FOR LIFERAFT STATIONS NO 1, 2,4 AND 7. 46CFR111.75-16.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Unknown
Issued 7 February 1985
Resolved
MAKE THE MAGNETIC COMPASS VISIBLE THROUGH THE SITE TUBE ON THE BRIDGE. 46CFR1136.30-35.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Navigation
Issued 7 February 1985
Resolved
PROVIDE A MAGNETIC COMPASS DEVIATION TABLE. 46CFR113.30-35.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Navigation
Issued 7 February 1985
Resolved
MOUNT A WIND SOCK ADJACENT TO THE HELICOPTER DECK. 46CFR108.223.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Unknown
Issued 7 February 1985
Resolved
RENEW THE MISSING TIE DOWNS ON THE HELICOPTER DECK. 46CFR108.223
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Navigation
Issued 7 February 1985
Resolved
MAKE OPERATIVE ALL OF THE AMBER LIGHTS ON THE HELICOPTER DECK. 46CFR108. 223.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
PROVIDE P-TANK RELIEF VALVES WITH A SET PRESSURE OF 40 OSI OR LESS. 46CFR54
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Engineering
Issued 7 February 1985
Resolved
DEMONSTRATE A SATISFACTORY OPERATIONAL TEST OF THE STREAM GENERATOR SAFETY DEVICE. THIS TEST IS TO BE WITNESSED BY A COAST GUARD INSPECTOR. 46CFR61.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985
Resolved
REPLACE THE VALVE HANDLES TO BOTH FOAM STATIONS NEAR THE HELICOPTER DECK 46CFR108.419
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
REPLACE THE FUEL HOSE AND CONNECTIONS ON THE TWO (2) MARINE PORTABLE TANKS (MUST BE NFPA APPROVED HOSE) 46CFR64.1
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
REPLACE THE FUEL HOSES ON THE THREE (3) CRANES WITH NFPA APPROVED HOSES. 46CFR108.419.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
PROVIDE A CAGE AROUND THE 20FT LADDER EXTENDING UP TO THE AFT CRANE STATION46CFR108.223
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Deck/Cargo
Issued 7 February 1985
Resolved
PROVIDE DOT HAZARD LABELS FOR THE DOT TANKS. 49CFR172.101.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985
Resolved
PROVIDE 4FT AND 10FT APPLICATORS WHICH PROPERLY FIT INTO THE FIRE NOZZLES. 46CFR108.404.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Navigation
Issued 7 February 1985
Resolved
PROVIDE AN OPERATING ALDIS LIGHT 46CFR111.75
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985
Resolved
HAVE THE BII FIRE EXTINQUISHER IN THE NO. 2 LIFEBOAT PROPERLY SERVICED. 46CFR108.404.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985
Resolved
PROVIDE (12) TWELVE APPROVED HAND HELD FLARES FOR THE NO 2. LIFEBOAT. 46CFR 109.217(B)
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Documentation
Issued 6 January 1984
Resolved
PROVIDE AND MAINTAIN VESSEL LOG IN ACCORDANCE WITH 46 CFR 109.431 AND .433.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Fire Fighting
Issued 6 January 1984
Resolved
PROVIDE LOW VELOCITY FOG APPLICATORS TO FIRE HOSE STATIONS SERVING THE HELIPORT. 46 CFR 108.425(D).
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
THE FOLLOWING DEIFICIENCIES PERTAIN TO THE MODU ALASKAN STAR DN577932.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Accommodation/Occupational Safety
Issued 6 January 1984
Resolved
PROVIDE NON-SKID SURFACE TO HELIPORT. 46 CFR 108.235.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Fire Fighting
Issued 6 January 1984
Resolved
PROVIDE COPY OF FIRE EXTINGUISHER SERVICING REPORT, REPORT TO RIG. 46 CFR 109.435
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 2 CONT. AND 2 SPARE BULBS FOR EACH FLASHLIGHT. 46 CFR 108.497.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Fire Fighting
Issued 6 January 1984
Resolved
PROVIDE A 3 CELL EXPLOSION PROOF FLASHLIGHT TO EACH FIREMAN'S OUTFIT WITH A SET OF SPARE BATTERIES,
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 11-A CONT. DOCUMENTATION TO BE PLACED ON RIG.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Electrical
Issued 6 January 1984
Resolved
PROVIDE DOCUMENTATION AS TO SUITABILITY FOR USE IN A CLASSIFIED LOCATION OFTHE EXLOG KELLY HEIGHT MONITORING DEVICE LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 6 February 1984
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 January 1984
Resolved
REPAIR LOSS OF PURGE AIR ALARM TO ROSS HILL CONTROLL PANNEL ON DRILL FLOOR.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Electrical
Issued 6 January 1984
Resolved
LABEL MOTOR CONTROLLERS IN THE MUD PIT ROOM TO SHOW WHICH MOTOR IS CONTROLLED. 46 CFR 111.70-20.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Navigation
Issued 6 January 1984
Resolved
PROVIDE THE CORRECT BULBS TO THE PORT, STARBOARD AND STERN RUNNING LIGHTS IAW MANUFACTURERS DIRECTIONS. 72 COLREGS.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Fire Fighting
Issued 6 January 1984
Resolved
PROVIDE 2 PORTABLE VL, FM OR CSA APPROVED OXYGEN AND COMBUSTIBLE GAS DETECTORS ABOARD THE RIG. 46 CFR 108.497(C).
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Lifesaving
Issued 6 January 1984
Resolved
PROVIDE LIFEBOAT EQUIPMENT LISTS STOWED IN EACH LIFEBOAT. 46 CFR 108.503(D).
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Lifesaving
Issued 6 January 1984
Resolved
REPAIR/REPLACE NO.1 LIFE BOAT SHAFT TO ELIMINATE WOBBLE.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 14 July 1983
Resolved
COMPLETE UNDERWATER PORTION OF SPECIAL EXAM IN ACCORDANCE WITH PROPOSAL OF 03JUN83 AND NOTIFY [name withheld] IN WRITING UPON COMPLETION.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Unknown
Issued 14 July 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE MODU ALASKAN STAR, DN577932
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Accommodation/Occupational Safety
Issued 12 November 1982
Resolved
REPLACE DAMAGED LOW PRESSURE AIR RECEIVER FOR TENSIONER SYSTEM.
Condition: Unknown
Due 12 November 1982
Resolved 12 November 1982
Electrical
Issued 12 November 1982
Resolved
MAKE THE TERMINAL CONNECTIONS FOR THE DRAW WORKS AND ROTARY TABLE MOTORS SUITABLE FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 12 November 1982
Resolved 12 November 1982