Industrial Vessel · Miscellaneous Vessel class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named EAGLE
EAGLE is a 1982 industrial vessel. The Coast Guard has recorded 57 inspections since 1982, most recently in January 2024, along with 40 deficiencies, 6 operational controls and 1 casualty investigation in 2010.
Records from 1982 to 2024. Most recent: inspection, 28 January 2024.
- Built
- 1982
- Last inspected
- 28 January 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 40 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2010
Identity
653836
8030714 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5VFV5
54363
Flag
TOGO
367198110 (licence lapsed)
Maury page id
psix-54363
Inspections, by type
…with no type recorded13
Years with a record
29 calendar years (1982–2024)
The 57 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Tonnage as PSIX records it693 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDI6884MMSI 367198110 · expired · compulsorily equipped · granted 24 March 2016, cancelled 30 May 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD8357MMSI 367198110 · cancelled · compulsorily equipped · granted 20 June 2007, cancelled 22 March 2016
WRB5838MMSI not assigned · cancelled · compulsorily equipped · granted 16 September 1997, cancelled 9 February 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 57
28 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856872
2 December 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7099030
28 October 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7084626
25 September 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7064393
14 August 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7031025
14 August 2020
PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7031905
31 May 2018
Deficiency Check · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6430195
30 May 2017
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6160684
14 February 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6088473
11 February 2016
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5813651
7 August 2015
Plan Review (Other than "T") · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5201354
23 January 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4223727
4 November 2010
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3885276
9 March 2009
Excursion Permit
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3431181
25 January 2009
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3400255
5 November 2008
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3344726
12 September 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3323288
3 July 2008
Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3255716
8 March 2008
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3160714
15 June 2007
COI Inspection · MTSA/ISPS Verification · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3042307
15 February 2007
Load Line/Change of Employment · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2872486
11 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1477968
19 March 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1060905
19 March 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449440
31 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047366
28 March 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372931
30 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810871
22 October 1998
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803969
17 September 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799518
17 September 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799931
3 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786391
23 September 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368409
3 March 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442519
19 September 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1377825
17 November 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442319
15 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 761213
14 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195379
23 September 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455192
3 December 1993
Re-Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422311
6 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 832059
2 November 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426734
10 January 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1269053
17 December 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221015
8 November 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212317
27 December 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927635
21 August 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349354
16 November 1988
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 895137
8 February 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1024254
17 December 1986
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1007736
2 September 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009985
25 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298714
14 August 1985
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1292758
18 January 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 979088
13 December 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 980721
21 June 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280355
30 December 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274563
22 July 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272657
Deficiency record · 40
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2020
Resolved
Emergency fire pump shall be an independently driven self contained pump positioned in a safe place outside the engine room and permanently connected to the fire mains.Emergency fire pump was not permanently connnected to the fire main system. CCSSC CH. 3/REG. 3.3.10.1
CODE: 17BC
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 25 September 2020
Resolved
The certificate referred to in 1.12.1 shall be supplemented by a record of equipment and ship information which shall be permanently attached thereto. Vessel's Caribbean Cargo Ship Safety Certificate is not accompanied by the required supplement. CCSSC 2018 Reg 1.12.1 Code: 10C
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 25 September 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 September 2020
Resolved
Medical Certificate shall remain Valid for a maximum period of 2 years. Master C. Rhoden's Medical Certificate has an expiration date of 05/06/2020
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 25 September 2020
Resolved
The garbage record book shall be in the form specified in the appendix of this annex...The entry for each discharge or incineration shall include...Category of the garbage and the estimated amount discharged or incinerated. Vessel's garbage record book does no account for E-waste as required by resolution MEPC.277(70) MARPOL (17 CONS) Annex V/REG. 10.3.2
CODE:50BC
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 13 June 2018
Resolved
Every ship of 400 gross tons and above shall be provided with a tank of adequate capacity. Waste oil tank at full capacity and bilge near half full.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 31 May 2018
Resolved
Ships shall carry a line throwing appliance of an approved type. The appliance shall capable of carrying a line of not less than 230 meters with reasonable accuracy and not less than 4 projectiles and 4 lines. projectiles on board of old shotgun style model with crew unfamiliar with its use.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 31 May 2018
Resolved
Every ship shall be provided with a satilite emergency positioning indicating radio beacon. Vesel's EPIRB service expired and needs vessel specific information updated with new information.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 31 May 2018
Resolved
Each opperator of a vesel described in 33CFR138.15 Must Establish evidence of financial responsibility (COFR). Vessel does not have a COFR.
Navigation › Piloting/Steering › Magnetic Compass
Issued 31 May 2018
Resolved
All ships 500 gross tons and above shall be fitted with a spare magnetic comass. Ship does not have a spare on board.
Navigation › Piloting/Steering › Gyro Compass
Issued 31 May 2018
Resolved
All ships 500 gross tons and above shall be fitted with a gyro compass. Vessel is not outfitted with a gyro compass.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 31 May 2018
Resolved
Ships 500 gross tons and above shall have an automatic tracking aid. Ship noot outfitted with an ARPA.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 31 May 2018
Resolved
Company and ship shall comply with the ISM code. Ship does not have applicable Safety management certificates.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 May 2018
Resolved
Every ship of 400 gross tons and above but less than 10,000 gross tons shall be fitted with oil filtering equipment. no OWS installed on vessel.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 30 May 2017
Resolved
Demonstrate proper operation of the propulsion system and arrangement.
Engineering › Generator (propulsion/auxiliary-electric) › Transformer Circuitry
Issued 11 February 2016
Resolved
Make forward generator ready for inspection.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 4 November 2010
Resolved
Prove proper operation of both SSDG over speed trip protection.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 4 November 2010
Resolved
Repair/replace starboard controller box for steering rudder indicator.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 4 November 2010
Resolved
Prove proper operation of all fuel shut off valves.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 November 2010
Resolved
Renew holed ballast water discharge piping
Engineering › Bilge Water Management System › Valve
Issued 4 November 2010
Resolved
Prove proper operation of secondary fire pump. (relief valve).
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 4 November 2010
Resolved
Provide automation procedures for approval, In accordance with 46 CFR 62, NVIC 1-78
Documentation › Logs/Records › Drug Test Records
Issued 4 November 2010
Resolved
Vessel's chemical testing program is not in compliance with 46CFR16, and 46CFR4. Company must provide proof that testing program is in place prior to sailing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 4 November 2010
Resolved
Paint locker has a fixed fire extinguishing system installed, however, paint lock is not properly sealed.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 November 2010
Resolved
Vessel's two radios are out for service. Radios must be on-board and tested prior to sailing.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 5 November 2008
Resolved
Repair/Replace CO2 head in engine room.
Communications › Internal Communications System › Sound-powered Telephone
Issued 5 November 2008
Resolved
Repair/Replace sound powered phone in engine room.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 5 November 2008
Resolved
Renew forward and aft starboard #1 fuel vent flame screens.
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 5 November 2008
Resolved
Renew upper starboard lube oil vent flame screen.
Construction/Loadline › Hull › Bottom Plating
Issued 8 March 2008
Resolved
Provide permanent repairs to vessel where temporary repairs have been conducted. Also provide permanent repairs to any areas not requiring temporary repairs at this time but are found to be outside wastage limits.
Construction/Loadline › Hull › Bottom Plating
Issued 7 March 2008
Resolved
Provide temporary repairs to holes in rudder compartment.
Lifesaving
Issued 28 March 2000
Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH COAST GUARD DISTRICT POLICY LETTER DATED 12NOV98 "RESCUE BOATS ON OFFSHORE SUPPLY VESSELS" TO THE SATISFACTIONOF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Navigation
Issued 19 September 1996
Resolved
REPAIR/REPLACE PORT RUDDER POST BRACKET AT NEXT DRY DOCK, BUT NLT 10JAN97.
Lifesaving
Issued 19 September 1996
Resolved
PROVIDE JACOBS LADDER.
Fire Fighting
Issued 19 September 1996
Resolved
REPLACE/REPAIR SLIDE BRACKET ON FIRE MONITOR.
Deck/Cargo
Issued 13 December 1984
Resolved
ALL FOUR LIQUID BULK TANKS TO BE INTERNALLY AND EXTERNALLY EXAMINED
Lifesaving
Issued 13 December 1984
Resolved
REPLACE 1 DEFECTIVE LIFE JACKET DUE TO TEAR. TOTAL ON BOARD TO BE 19
Unknown
Issued 13 December 1984
Resolved
REPAINT OFFICIAL NO. NET TONS ON ENGIN ROOM BKHD. WHERE IT IS PERMANENTLY MARKED ON THE PORT SIDE AFT BKHD.
Engineering
Issued 13 December 1984
Resolved
MARK ALARM LITES ON ENGIN ROOM ALARM PANEL TO SHOW WHAT ALARMS THEY ARE SOUNDING FOR. SEVERAL ARE JUST A FLASHING RED LITE WITH NO MARKING.
Unknown
Issued 13 December 1984
Resolved
ALL FOUR DRY BULK TANKS TO BE INTERNALLY EXAMINED
Casualty record · 1
7 June 2010Routine · role: Involved in a Marine Casualty · activity 3762214
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SPT VIGILANCE (2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.