MAURY USCG vessel records Sign in
← All vessels

POLK TIDE

POLK TIDE is a 1982 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1982, most recently in November 2008, along with 100 deficiencies and 2 casualty investigations in 2002.

Records from 1982 to 2008. Most recent: inspection, 9 November 2008.

Built
1982
Last inspected
9 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8218976 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB3677
Flag
VANUATU
366890080, 368164000 (licence lapsed)
Maury page id
psix-54371

Inspections, by type

…with no type recorded14
Years with a record 26 calendar years (1982–2008)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it296 - Regulatory (Subpart C or D), Gross Ton
874 - Convention (Subpart B), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
262 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB3677MMSI 366890080 · cancelled · compulsorily equipped · granted 17 April 2003, cancelled 28 August 2007
WCZ6129MMSI not assigned · cancelled · compulsorily equipped · granted 5 January 2000, cancelled 15 May 2003
WAS2427MMSI 368164000 · cancelled · compulsorily equipped · granted 22 January 1998, cancelled 7 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ENSCO 84 Mobile Offshore Drilling Unit · MISLE 52770 · 1 March 2002 · activity 1493352ATLAS TIDE Offshore Supply Vessel · MISLE 54790 · 1 March 2002 · activity 1493352SEACOR TEXAS Offshore Supply Vessel · MISLE 229724 · 15 May 1995 · activity 86534OCEAN WINNER Mobile Offshore Drilling Unit · MISLE 259610 · 15 May 1995 · activity 86534

Inspection history · 54

9 November 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3360193
27 January 2007 Deficiency Check · COI Inspection
Physical examination · Activities Europe · Activity 2851880
9 July 2006 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Activities Europe · Activity 2712199
11 April 2006 Internal Structural Exam · Annual Inspection
Physical examination · Activities Europe · Activity 2607156
7 October 2005 Deficiency Check
Physical examination · Activities Europe · Activity 2509599
14 April 2005 Periodic Inspection
Physical examination · Activities Europe · Activity 2324429
25 February 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2299037
4 August 2004 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2155481
29 May 2004 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2083295
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971318
24 June 2003 Hull Examination · Re-Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1825289
15 April 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1604826
1 March 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1493352
28 January 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1699852
24 January 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1480952
23 May 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1068393
11 April 2001 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448248
15 February 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059436
27 January 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 815946
27 January 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1403055
18 February 1999 Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1130560
28 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 20137
25 February 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1115173
4 February 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1438689
20 March 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402410
12 August 1996 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1388094
9 February 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360412
15 May 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 86534
22 March 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460773
11 February 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453014
12 May 1993 Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445986
16 April 1992 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269774
12 March 1992 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948757
9 March 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 175132
14 January 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1269167
12 December 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1257792
10 January 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219490
3 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925714
26 November 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910781
6 November 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928647
8 December 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219766
2 February 1989 Hull Examination · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1032563
15 November 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1205553
12 May 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1347594
4 December 1987 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1314709
10 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324518
23 December 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004136
24 November 1986 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026061
30 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301876
16 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982295
20 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978861
25 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279621
29 December 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968028
29 December 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971003

Deficiency record · 100

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 27 January 2007 Resolved
Meet the requirements of the oil transfer procedure prior to conducting any bunking operation. Report cleared via E-mail 29 Jan 2007, Item remains open until cleared by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 27 January 2007 Resolved
Repair or replace fuel tank sighting tubes prior to getting underway. Report cleared via E-mail 29 Jan 2007, Item remains open until cleared by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 27 January 2007 Resolved
Meet the ISM code part 10, requirement for documenting the person completing system check-list. Report cleared via E-mail 26 Feb 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 27 January 2007 Resolved
Galley vent hood filters are to be installed. Report cleared via E-mail 26 Feb 2007, Item remains open until cleared by attending Marine Inspector.
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 27 January 2007 Resolved
Make permanent repairs to the paint Locker vent cover prior to getting underway. Report cleared via E-mail 29 Jan 2007, Item remains open until cleared by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 27 January 2007 Resolved
Remove all paint from any space other than the paint locker prior to getting underway. Report cleared via E-mail 29 Jan 2007, Item remains open until cleared by attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 January 2007 Resolved
Properly mark the engine room escape route. Report cleared via E-mail 26 Feb 2007, Item remains open until cleared by attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 27 January 2007 Resolved
Clean all alarms lights and signs of paint. Report cleared via E-mail 29 Jan 2007, Item remains open until cleared by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 21 July 2008
Resolution: Reflagged
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Due 19 November 2006
Resolved 30 December 2008
Resolution: VRP #04125 deactivated per correspondence dated 12/19/08
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006 Resolved
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization for the LA/Long Beach Captain of the Port zone
Due 19 November 2006
Resolved 30 December 2008
Resolution: VRP #04125 deactivated per correspondence dated 12/19/08
Construction/Loadline › Hull › Stringer
Issued 9 July 2006 Resolved
Complete steel work in Starboard chain locker: Doubler to be cropped and renewed nest to hatch, angle bar below hatch - partially cropped and renewed and spurling pipe - crop and renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2006
Electrical › Lighting (service) › Conductor
Issued 9 July 2006 Resolved
Fix light in Starboard Chain locker.
Action required: 705 - Other - as specified
Due 10 August 2006
Resolved 1 August 2006
Construction/Loadline › Hull › Girder
Issued 9 July 2006 Resolved
Complete steel work in port chain locker: Renew spurling pipe and overhead frames - crop and renew 2 overhead frames.
Action required: 705 - Other - as specified
Due 14 August 2006
Resolved 2 August 2006
Electrical › Lighting (service) › Conductor
Issued 9 July 2006 Resolved
Fix light in port chain locker.
Action required: 705 - Other - as specified
Due 1 August 2006
Resolved 1 August 2006
Construction/Loadline › Penetrations › Gasket
Issued 9 July 2006 Resolved
Replace gasket on hatch of port chain locker.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Construction/Loadline › Hull › Hull Plating
Issued 9 July 2006 Resolved
Complete steel work in aft peak stbd: Crop and renew 2 outboard side frames (buckeled iwo chine inset, one m2 bottom plating buckeld at chine - crop and renew, 2 insets next to roller - crop and renw and 1 bottom frame wsted below hatch.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Construction/Loadline › Hull › Hull Plating
Issued 9 July 2006 Resolved
Complete steel work in aft peak port: crop and renew inset next to roller.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Construction/Loadline › Hull › Girder
Issued 9 July 2006 Resolved
Complete steel work in #3 starboard ballast: replace 6 aft frames on floor.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 9 July 2006 Resolved
Source of leak on #2 Stbd bulk tank determined to be a pin hole in shell. Tank is to remain out of service until proper repairs are completed iaw 46 CFR Part 54 and ASME Code Section VIII. Prior to beginning any repairs, submit repair proposal to USCG. Received e-mail that tank is OOC. Verify tank status at next inspection in JAN 2007.
Action required: 705 - Other - as specified
Due 1 August 2006
Resolved 1 August 2006
Deck/Cargo › Ballast › Tank
Issued 9 July 2006 Resolved
Clean and gauge all void spaces in #2 and #3 Ballast Tanks.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Construction/Loadline › Structures › End Bulkhead
Issued 9 July 2006 Resolved
Engine Room bulkhead to #3 port fuel tank - replace soft patch with insert.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Resolution: Pin hole was along the weld seam. Rewelded seam and corrected hole.
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 July 2006 Resolved
Complete steel work in steering room: Replace tow longs port (entire length) and starboard (partial) on either side of centerline and all additional areas as marked after gauging was completed.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Construction/Loadline › Hull › Bottom Plating
Issued 9 July 2006 Resolved
In Passageways additional gauging on bottom frames.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Construction/Loadline › Hull › Bottom Plating
Issued 9 July 2006 Resolved
In passageway guaging iwo of transducer.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Fire Fighting › Fire Hoses › Condition
Issued 9 July 2006 Resolved
Pressure tes firefighting test hoses above 100 psi.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 July 2006 Resolved
CO2 servicing - provide copy of service report. Include record of time delay and insure contents measured by weighing vice liquid level gauging.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 21 July 2006
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 9 July 2006 Resolved
Remove/replace teakettle and toaster in the galley. Both are fire hazards. Auto shut off does not work on either unit.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 1 August 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 July 2006 Resolved
Repair sink in head on 01 level.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 July 2006 Resolved
Provide name, phone and email for operator. Compare with ISSC, COI, and CSR.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 1 August 2006
Lifesaving › Launching Appliances › Falls
Issued 9 July 2006 Resolved
Falls were installed in APR2001. Replace falls and complete overload and light load tests with ABS inspector.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 2 August 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 July 2006 Resolved
Swing compass and provide new deviation table after completion of drydock.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 15 August 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 9 July 2006 Resolved
Complete annual hydrostatic pressure testing iaw 33 CFR 156.170.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 19 October 2006
Resolution: Last pressure test was completed on 10/11/05
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 9 July 2006 Resolved
Galley vent closure outside the superstructure is missing. Replace closing flap.
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 24 October 2006
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 9 July 2006 Resolved
Vessel does have an class approved ISM system onboard. Vessel is required by CG regs iaw NVIC 11-93, Ch-3 to comply with international conventions which took affect after 1982 (ie ISM and ISPS). The applicable tonnage for the new regs is the ITC tonnage.
Condition: Placed in Improper Service
Due 28 January 2007
Resolved 27 January 2007
Resolution: Sighted SMC.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 April 2006 Resolved
Label the breakers in the distribution panels in the E/R.
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 9 July 2006
Resolution: Breakers are labeled.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 11 April 2006 Resolved
Replace RPM gauge on #1 generator.
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 9 July 2006
Resolution: RPM gauge has been replaced.
Fire Fighting › Means of Escape › Doorways
Issued 11 April 2006 Resolved
Escape hatches from the engine room to deck were again found unopenable by 1 man exiting engineroom and the dogs were not properly adjusted to make watertight seal. Vessel adjusted tension spring and dogs to demonstrate adequate operation prior to end of exam. Springs still need to be replaced at drydocking to insure def does not repeat again.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2006
Resolved 1 August 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 11 April 2006 Resolved
Found jury rigged temp light installed in the passageway leading to engineroom. Permanently fix light into distribution system and install permanent fixture.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 August 2006
Resolved 1 August 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 11 April 2006 Resolved
Conduct annual pressure tests on cargo transfer hoses iaw 33 CFR 156.170.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 1 August 2006
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 11 April 2006 Resolved
Galley exhaust duct is missing the vent closure. Replace duct closure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 1 August 2006
Lifesaving › Launching Appliances › Falls
Issued 11 April 2006 Resolved
Falls on rescue boat davit have not been replaced since 2001. Replace fall at upcoming drydock and complete required testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 2 August 2006
Engineering › Compressed Air System (start air) › Valve
Issued 11 April 2006 Resolved
Complete testing on the relief valves for bulk tanks, bulk compressors, and air receivers.
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 2 August 2006
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 11 April 2006 Resolved
Hydraulic oil leaking from anchor windlass motor. Overhaul motor and seal during upcoming drydock and make repairs to clutch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 2 August 2006
Construction/Loadline › Hull › Hull Plating
Issued 11 April 2006 Resolved
Crop and renew sharp insets in the stern on either side of the stern roller.
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 2 August 2006
Navigation › Piloting/Steering › Compass Deviation Table
Issued 11 April 2006 Resolved
Swing compass and provide new compass deviation table after upcoming drydock.
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 19 October 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 21 April 2005 Resolved
Hydro test f/o transfer hose per 33 CFR 154.500
Due 20 May 2005
Resolved 19 May 2005
Resolution: Rcvd e-mail copy of cert for hose. T.G. [name withheld], LT
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 21 April 2005 Resolved
Replace rubber dryer vent hose with metal ducting.
Due 20 May 2005
Resolved 21 May 2005
Resolution: Corrected. T.G. [name withheld], LT
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 April 2005 Resolved
Adjust assist springs on Port and Stbd engine room escape hatches.
Due 20 May 2005
Resolved 21 May 2005
Resolution: Hatch springs adjusted, verified via e-mail w/[name withheld] and statement from vsl master [name withheld] [name withheld], LT
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 April 2005 Resolved
Use contrasting colors to mark the security latching devices for Port and Stbd engine room escape hatches.
Due 20 May 2005
Resolved 21 May 2005
Resolution: Verified via phonecon w/[name withheld], LT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 April 2005 Resolved
Hydro test for CO2 bottles due in Oct 05, hydro or replacement of bottles to be accomplished during the required Jul 05 annual servicing. Servicing to be witnessed by a competent crew member. A copy of the servicing report and statement of satisfactory completion of service to be submitted to MIO EUROPE by the Master.
Due 31 July 2005
Resolved 11 August 2005
Resolution: Rcvd fax from technical manger providing copy of required hydro tests.
Engineering › Bilge Water Management System › Piping
Issued 21 April 2005 Resolved
Renew bilge discharge line at first tee fitting from pump, soft patch currently marking area to be repaired.
Due 20 May 2005
Resolved 21 May 2005
Resolution: Resolved. T.G. [name withheld], LT
Engineering › Fuel Oil Service System › Valve
Issued 21 April 2005 Resolved
Properly mark remote emergency fuel shut off valves on deck.
Due 20 May 2005
Resolved 21 May 2005
Resolution: New markings verified via e-mail from master [name withheld] [name withheld], LT
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 April 2005 Resolved
Replace eye wash solution on stations as required.
Due 20 May 2005
Resolved 21 May 2005
Resolution: Verified via phonecon w/ [name withheld]. T.G. [name withheld], LT
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 21 April 2005 Resolved
Clean air intakes and filters for main diesel engines.
Due 20 May 2005
Resolved 21 May 2005
Resolution: Verified via phonecon w/[name withheld]. T.G. [name withheld], LT
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 April 2005 Resolved
Provide USCG approved machinery automation procedure and test all required engine shutdowns and alarms IAW automation procedures. Full engine room manning requirements per COI to remain in place until deficiency is cleared.
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 25 September 2005
Resolution: Rcvd fax from technical manager providing copies of completed test procedures.
Navigation › Piloting/Steering
Issued 29 May 2004 Resolved
Update or provide new charts for operation area prior to getting underway. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2004
Resolved 2 June 2004
Engineering › Bilge Water Management System
Issued 29 May 2004 Resolved
Remove all oil from engineroom bilges prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2004
Resolved 31 May 2004
Electrical › Electric Supply System (service)
Issued 29 May 2004 Resolved
Install drip shields for battery chargers on bridge for emergency lights and general alarm. LEGACY COMPONENT DESC: Battery Charger
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 31 May 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 24 January 2002 Resolved
CURRENT COPY OF NAV RULES NOT PROVIDED.
Condition: Unknown
Due 28 January 2002
Resolved 28 January 2002
Fire Fighting › Fire Main
Issued 24 January 2002 Resolved
FIRE MONITOR PIPING ABOVE PILOT HOUSE WAS FOUND TO HAVE A DOUBLER PLATE. C/R PIPING AS NECESSARY. LEGACY COMPONENT DESC: PIPING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Construction/Loadline › Structures › Air Pipe
Issued 24 January 2002 Resolved
FLAME SCREEN NOT INSTALLED IN SEWAGE VENT.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Accommodation/Occupational Safety
Issued 24 January 2002 Resolved
WASHER AND DRYER NOT SECURED. LEGACY COMPONENT DESC: WASHER AND DRYER
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Electrical › Electric Supply System (service) › Cable
Issued 24 January 2002 Resolved
EXTENTION CORD WIRED INTO ELECTRICAL DISTRIBUTION BOX INSIDE REFRIDGERATION COMP.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 24 January 2002 Resolved
MAIN SWITCHBOARD HAD BAD GROUND.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering › Fuel Oil Service System › Filter
Issued 24 January 2002 Resolved
FLAME BOWLS NOT PROVIDED FOR ON THREE FUEL FILTERS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 January 2002 Resolved
BOTH SHAFT PACKINGS EXCESSIVLEY LEAKING. LEGACY COMPONENT DESC: SHAFTS
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Engineering › Fuel Oil Service System › Hose
Issued 24 January 2002 Resolved
CONDEMENED TWO FUEL OIL HOSES ON PORT GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering
Issued 24 January 2002 Resolved
EXHAUST LAGGING MISSING ON STARBOARD GENERATOR PIPING. LEGACY COMPONENT DESC: LAGGING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering › Fuel Oil Service System
Issued 24 January 2002 Resolved
FUEL OIL LEAK ON PORT LIQUID MUD ENGINE FUEL OIL PIPING. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering › Steering Gear System › Hydraulic Hose
Issued 24 January 2002 Resolved
CONDEMENED TWO HYDRALIC HOSES ON STARBOARD STEERING SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Electrical › Electrical Distribution System (service) › Switch
Issued 24 January 2002 Resolved
REMOTE FUEL OIL SWITCH NOT WORKING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering › Fuel Oil Service System › Piping
Issued 24 January 2002 Resolved
C/R APPROX 6FT FUEL OIL PIPING IN ENGINE ROOM DUE TO WASTAGE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Construction/Loadline › Structures › Door
Issued 24 January 2002 Resolved
RUDDER ROOM WATERTIGHT DOOR OUT OF ADJUSTMENT.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Electrical › Lighting (service)
Issued 24 January 2002 Resolved
GUARD NOT PROVIDED FOR RUDDER ROOM LIGHT FIXTURE. LEGACY COMPONENT DESC: GUARD
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Construction/Loadline › Hull › Transverse Frame
Issued 24 January 2002 Resolved
C/R IWO RUDDER ROOM (3) DEEP FRAMES.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Engineering
Issued 24 January 2002 Resolved
CHAFFING GEAR NOT PROVIDED ON NUMERUOUS HOSES THROUGHOUT ENGINE ROOM. LEGACY COMPONENT DESC: CHAFFING GEAR
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Deck/Cargo › Cargo Stowage
Issued 24 January 2002 Resolved
ALL LIQUID MUD VENTS NOT PROVIDED WITH FLAME SCREENS. LEGACY COMPONENT DESC: VENTS
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Engineering › Lubricating Oil Service System › Piping
Issued 24 January 2002 Resolved
LUBE OIL SOUNDING TUBE AT MAIN DECK BROKEN.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 January 2002 Resolved
ELECTRICAL FIXTURE IN PORT DECK LOCKER NOT PROVIDED WITH ELECTRICAL PACKING.
Condition: Improper/Lack of Maintenance
Due 28 January 2002
Resolved 28 January 2002
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 24 January 2002 Resolved
CONDEMENED ONE FUEL OIL CARGO HOSE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2002
Resolved 28 January 2002
Lifesaving › Rescue Boat Equipment
Issued 24 January 2002 Resolved
ALL RESCUE BOAT EQIPMENT NOT PROVIDED. LEGACY COMPONENT DESC: ALL EQUIPMENT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2002
Resolved 28 January 2002
Construction/Loadline
Issued 11 April 2001 Resolved
Various frames throughout the vessel were deteriorated and required to be replaced as original.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Numerous stiffeners throughout vessel deteriorated and required to renew asoriginal.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Renew as original, plating under freezer in #1 stbd ballast tank where two small holes were detected.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Pad weld deteriorated area on bottom plate under stbd keel cooler as determined by gauging.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Detected 04 small pinhole leaks during air test of collision blkhd. Corrected on the spot.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Construction/Loadline
Issued 4 February 1998 Resolved
RENEW WASTED #1 (OUTBOARD) LONGITUDINAL FLOOR FRAMES ON BOTH THE PORT AND STARBOARD SIDE OF THE RUDDER ROOM.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Construction/Loadline
Issued 4 February 1998 Resolved
RENEW WASTED #1 (FWD) TRANSVERSE FLOOR FRAME LOCATED IN THE RUDDER ROOM.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Deck/Cargo
Issued 4 February 1998 Resolved
RENEW INSULATION BLANKET ON EXHAUST AIR PIPE FROM THE BULK TANK COMPRESSOR LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Electrical
Issued 4 February 1998 Resolved
PROVIDE SWITCH KNOB MISSING FROM GENERATOR PANEL FOR THE #1 GENERATOR.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Electrical
Issued 4 February 1998 Resolved
CLEAN PORT AND STARBOARD GENERATOR WINDINGS AND COVER VENTS.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Lifesaving
Issued 4 February 1998 Resolved
DRAIN OIL FROM AND SECURE FROM MOVEMENT THE OIL FILTER DRAIN BOX LOCATED INTHE ENGINE ROOM.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Lifesaving
Issued 4 February 1998 Resolved
RENEW SUN DETERIORATED LINE ON RING BOUY LOCATED ON PORT SIDE OF WHEEL HOUSE.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Construction/Loadline
Issued 4 February 1998 Resolved
REPAINT FADED LOADLINE MARKINGS ON BOTH SIDES OF VESSEL.
Condition: Unknown
Due 4 February 1998
Resolved 4 February 1998
Construction/Loadline
Issued 16 April 1992 Resolved
DRYDOCK VESSEL TO ASSESS GROUNDING DAMAGE IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR. VESSEL'S OPERATION IS RESTRICTED UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Construction/Loadline
Issued 12 March 1992 Resolved
DRYDOCK VESSEL TO ASSESS GROUNDING DAMAGE IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR. VESSEL'S OPERATION IS RESTRICTED UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Deck/Cargo
Issued 6 November 1990 Resolved
HAVE P-TANKS CLEANED DUST FREE AND GAS FREED BY MARINE CHEMIST AND READY FOR INTERNAL INSPECTION BY COAST GUARD INSPECTOR AT NEXT CREDIT DRYDOCK.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Documentation
Issued 6 November 1990 Resolved
SUBMIT FIRE CONTROL PLAN TO [name withheld] FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Deck/Cargo
Issued 24 November 1986 Resolved
PROVIDE TWO SEALED RELIEF VALVES FOR THE BULK CEMENT AIR COMPRESSERS.
Condition: Unknown
Due 24 November 1986
Resolved 24 November 1986
Documentation
Issued 24 November 1986 Resolved
PROVIDE ONE (1) APPROVED DRAWING SHOWING ALL PORTABLE FIRE EXTINGUSER LOCATIONS. (FIRE CONTROL PLAN).
Condition: Unknown
Due 24 November 1986
Resolved 24 November 1986

Casualty record · 2

28 January 2002Routine · role: Involved in a Marine Casualty · activity 1699852
1 March 2002Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1493352
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

., ENSCO REPUBLIC, MOSS POINT MARINE HULL #035, NI (2002), ENSCO REPUBLIC (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.