CAPITAL COMMODORE

CAPITAL COMMODORE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 102 inspections since 1982, most recently in August 2025, along with 125 deficiencies — 1 with no resolution recorded —, 3 operational controls and 1 casualty investigation in 2008.

Records from 1982 to 2025. Most recent: inspection, 4 August 2025.

Built
1982
Last inspected
4 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBR2335
Flag
UNITED STATES
367107280
Maury page id
psix-54373

Inspections, by type

…with no type recorded31
…past their stated due date1
Years with a record 41 calendar years (1982–2025)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)97.2 ft × 23.0 ft × 7.4 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSACRAMENTO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBR2335MMSI 367107280 · active · compulsorily equipped · granted 14 February 2018, expires 1 April 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 102

4 August 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8196926
7 July 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8178422
15 April 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116375
16 July 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959488
6 February 2024 Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7861179
27 July 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7751233
16 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7689604
4 May 2022 COI Inspection · Internal Structural Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7444201
4 March 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7397570
14 July 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7249956
26 February 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7147269
13 July 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005226
6 February 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904313
12 August 2019 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6781049
7 February 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6621312
2 November 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6573611
26 September 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6547155
21 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6545701
25 September 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6274382
17 July 2017 In-Service Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Plan Review (Other than "T") · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212314
19 September 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6004562
30 July 2016 Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962776
14 May 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5880712
16 July 2015 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5186574
15 May 2012 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4321656
22 July 2011 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4090807
6 July 2009 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3525495
18 June 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3747534
14 June 2008 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3321188
28 May 2008 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3191589
12 September 2007 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3040619
31 May 2007 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2925140
24 May 2007 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2992551
1 June 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2634947
7 February 2006 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2551250
15 February 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2305820
1 June 2004 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2059906
16 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2025655
25 February 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2022123
23 December 2003 Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1968826
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970863
17 June 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1819697
2 July 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1640287
3 June 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1623030
22 January 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1480245
31 May 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391604
1 June 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1436394
17 May 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 175365
27 January 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393322
22 July 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1438877
21 July 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 169793
8 July 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391057
10 November 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1397020
16 July 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1129797
6 June 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471159
7 May 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 199741
7 May 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 763816
4 May 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 792299
24 February 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427468
30 January 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1121007
22 January 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 645935
17 December 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 82376
17 December 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 215006
17 December 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386151
14 October 1997 Drydock Extension · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1383684
4 June 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1427373
4 June 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1360556
31 October 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1367546
13 July 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 752550
12 July 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 191489
8 June 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1358851
11 March 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 159723
16 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1160324
13 June 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1326850
29 July 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 842427
22 June 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 843739
27 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 61605
16 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 834295
23 June 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 952839
25 September 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384947
25 June 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 907737
11 March 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1219499
26 December 1990 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1224266
6 August 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1233542
26 June 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1218506
23 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1220534
27 June 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210543
21 June 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210540
25 January 1989 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205409
27 July 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1341588
17 November 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023729
15 October 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1321610
10 August 1987 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013441
18 November 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1325405
21 November 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986590
12 November 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1299686
2 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1285768
14 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976491
20 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977450
25 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977293
20 December 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278514
20 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970550

Deficiency record · 125

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating, and planking, voids, and ballast, cargo, and fuel oil tanks. MI observed significant pitting in centerline of tank space, ultrasonic test the space to determine hull thickness. 46 CFR 176.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Operator conducted ultra sonic testing and determined hull thickness in area of concern.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 July 2024 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI observed loose port rudder angle indicator being secured by ziptie, make permanent repairs to MI satisfaction. 46 CFR 115.814
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: MI observed sat repair made of permanent installation of port rudder angle indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2024 Resolved
Exhaust gas must not leak from piping or any connections. Both engines and generator had exhaust leaks in engine room, repair to MI satisfaction. 46 CFR 119.430 (b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Vessel operator took apart affect areas with exhaust leaks, reinstalled tightning areas, and conducted soap test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull and its appurtenances, including the following; inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. MI observed 3 cracks in 3 different welds in starboard forepeak top of frame 4. Make permanent repairs to MI satisfaction prior to next credit drydock. 46 CFR 115.802
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified repaired welds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2024 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. 01 KAPOK PFD found UNSAT for continued use. Replace PFD to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Operator replaced old PFD with new PFD.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2024 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route. Bottom starboard window allowed water intrusion with wood damage, repair to MI satisfaction. 46 CFR 116.1020
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Operator replaced old deteriorated wood in damaged area and affected permanent.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating, and planking, voids, and ballast, cargo, and fuel oil tanks. Operator conducted ultrasonic testing in centerline of forward void tank space identifying areas containing more than 25% wastage. Clean affected areas identified by ultra-sonic test report marked red and apply corrosion resistant protective compound to MI satisfaction. Operator must submit repair plan to be approved by attending marine inspector prior to 28FEB2025 to receive next credit dry dock. 46 CFR 176.610
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified permanent repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel has opted to not haul out and conduct repairs as previously agreed upon from prior annual inspection. Vessel is restricted from passenger carriage until all repairs are made to the satisfaction of the Marine Inspector. 46 CFR 115.500(b)(1)(iii)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024 Resolved
A drydock examination conducted in compliance with § 115.600 of this part must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Vessel conducted its drydock inspection on 06FEB2024, but has not been able to complete the required worklist items in a timely fashion. Vessel is not allowed to carry passengers until drydock worklist is completed. 46CFR115.610(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2024
Resolution: completed worklist items for dry dock
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child life jackets are not mistaken for adult life jackets. Adult and Child life jackets in stowage compartment near pilothouse are not appropriately separated and marked. Provide provisions for proper storage and marking to satisfaction of Marine Inspector. 46 CFR 117.78 (a) (5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 10 August 2023
Resolution: Separated child sized life preservers from adults.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket storage areas throughout vessel are improperly marked with number of life jackets inside. Ensure markings correspond with correct number of life jackets in each compartment to satisfaction of Marine Inspector. 46 CFR 122.604 (f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 24 August 2023
Resolution: Markings provided via photos.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 May 2023 Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter no later than the month and year on its servicing sticker affixed. Vessel's IBA is expired for servicing. 46 CFR 122.730(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 7 June 2023
Resolution: IBAs serviced. Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023 Resolved
Kerosene are prohibited for cooking, heating, or lighting on ferry or passenger vessels. Multiple kerosene heaters/lights were found on the vessel. Remove kerosene heaters/lights to the satisfaction of the attending marine inspector. 46 CFR 147.50(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 7 June 2023
Resolution: Kerosene equipments removed from vessel. Sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 May 2022 Resolved
An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hooks bolts is considered open to the weather if battening, caulking, or gaskets of any material are not used. Aft tonnage door on stern main deck caulked on outside and covered inside with paneling preventing its removal. Repair by next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 7 July 2025
Resolution: MI verified removal of caulking from aft tonnage opening.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 May 2022 No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspections of the hull structure including the following: inspection of all accessible parts of the exterior of the hull, the watertight bulkheads, and weather decks. Tank void aft starboard outboard bulkhead found with 3" horizontal fracture located 5" beneath overhead. Monitor condition of fracture through August 4 2022. If fracture has not progressed, repair at next credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 August 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2020 Resolved
At least one ring buoy must be fitted with a floating waterlight. Discovered expired battery on ring buoy waterlight on stbd bridge wing. Vessel operations restricted to daytime operations only. 46 CFR 117.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2020
Resolved 27 July 2020
Resolution: Received documentation depicting properly installed battery for operational waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020 Resolved
Each life jacket must be marked with Type I retroreflective material. (17) Adult life jackets identified with worn retroreflective tape that requires replacement.46 CFR 122.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 27 July 2020
Resolution: Received documentation from operator depicting properly affixed new retroreflective material on noted PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020 Resolved
Each life jacket kept in a stowage container must be readily available. Discovered broken hinges on PFD stowage compartment on second deck, fwd of pilothouse. 46 CFR 117.78(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 27 August 2020
Resolution: Received electronic documentation of properly replaced PFD storage hinges.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Working spaces)
Issued 13 July 2020 Resolved
Each lighting fixture must have a guard. No light guard was present on second deck soda locker overhead light.46 CFR 120.410 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 27 August 2020
Resolution: Received electronic verification of properly affixed light guard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020 Resolved
The person in command of a documented vessel must have onboard that vessel the original Certificate of Documentation currently in effect for that vessel. The vessel does not have a Certificate of Documentation onboard.46 CFR 67.313
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 17 July 2020
Resolution: Received documentation from vessel rep with renewed COD.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2020 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. Vessel's fire pump was not able to achieve a pressure of 60 pounds per square inch at the pump outlet. 46 CFR 181.10-1(c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 4 May 2022
Resolution: Witnessed sat testing of fire pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 July 2020 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends 305 millimeters (12 inches) above the weather deck. Forward hatch coaming has several drilled holes, rendering hatch not weathertight.46 CFR 116.1160(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 4 March 2022
Resolution: Operator repaired area where holes were present. Satisfactory weathertight hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 September 2018 Resolved
46CFR 170.270(e) - For each watertight door, an indicator must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. Watertight door leading to lazarette is missing appropriate indicator at operating station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 9 October 2018
Resolution: QAWTD indicator at operating station verified to operate satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2018 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Stowed so that when the vessel sinks the survival craft floats free and inflates automatically. Survival craft stowed with painter line not secured to float-free link. Painter line left unsecured, craft would not auto inflate.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 September 2018
Resolved 27 September 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018 Resolved
AIS PLACEMENT NOT PROVIDED: incomplete dimension information (AIS Antenna Position “X” equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 May 2022
Resolution: Witnessed proper display of outstanding AIS info.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2017 Resolved
Remove hanging light mounted to the wall near ice chest; 120 V without grounding pol
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed hanging lights near ice chest.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 September 2017 Resolved
provide cover in overhead light near ice chest in lower bar area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Provided cover for light.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2017 Resolved
Remove track lighting (120v) in bar area replace with lighting utilizing a grounding pole (3 prong)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed track lighting.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 September 2017 Resolved
Replace trash cans with metallic bins
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: New metallic bins were ordered for the vessel.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 September 2017 Resolved
Remove ext. cord in bar
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed extension cords.
Engineering › Pressure Vessel › Weld
Issued 25 September 2017 Resolved
Hydrostatically test the stbd compressor or remove from service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Disconnected the air compressor and will not be using it.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 September 2017 Resolved
provide ammonia inhalants in first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Provided new ammonia inhalants
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 25 September 2017 Resolved
replace lagging in generator room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Replaced lagging in generator room.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 September 2017 Resolved
Seal exposed wiring at fridge outlet
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Seal exposed wires at the fridge outlet.
Construction/Loadline › Penetrations › Valve Flange
Issued 17 July 2017 Resolved
Replace raw water overboard valve assembly #2 due to wear in ball valve (see DOCUMENTS tab).
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 23 August 2017
Resolution: Marine Inspector visited vessel and ensured raw water overboard valve assembly was replaced.
Construction/Loadline › Hull › Side Shell
Issued 17 July 2017 Resolved
Repair starboard side sponson and make watertight; ensure watertight integrity via pressure test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 23 August 2017
Resolution: Marine Inspector visited vessel and witnessed satisfactory repairs and pressure test.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Engineering › Pressure Vessel › Foundation
Issued 8 September 2011 Resolved
Provide repair proposal for leak found on portside air reciver.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 September 2011
Resolution: Replaced air compressor with a smaller size. Inspected the installation, all sat.
Engineering › Pressure Vessel › Foundation
Issued 8 September 2011 Resolved
Repair or replace the portside air receiver to satisfy section VIII of the ASME code and the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2011
Resolved 30 September 2011
Resolution: The vessel rep renewed the air receiver with a pressure vessel of a smaller size. Inspected the installation and tested the relief valve.
Engineering › Pressure Vessel › Foundation
Issued 8 September 2011 Resolved
If the air receiver is repaired, then hydrostatically test the receiver at 1.5 times the MAWP in the presence of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2011
Resolved 30 September 2011
Resolution: Installed a new receiver of a smaller size. Inspected the installation and tested.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 August 2011 Resolved
Install a working latch on portside galley breaker panel.
Action required: 705 - Other - as specified
Due 23 August 2011
Resolved 8 September 2011
Resolution: Installed a latch.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2011 Resolved
Provide aspirin for first aid kit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 August 2011
Resolved 8 September 2011
Engineering › Pressure Vessel › Weld
Issued 22 July 2011 Resolved
Conduct a hydrostatic test for cause on both unfired pressure vessels in the presence of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2011
Resolved 8 September 2011
Resolution: Conducted a hydrostatic test on both unfired pressure vessels. Both vessels were pressed up to 300psi. Found a pin hole leak on the portside receiver. Issued a seperated CG-835. see narrative for details.
Lifesaving › Lifefloat › Capacity
Issued 16 July 2009 Resolved
Provide prope lifesaving capacity for vessel to operate on a limitied coastwise route, restricted to 100 passnegers on limited coastwise route and 200 passengers on lakes, bays and sounds route.
Action required: 705 - Other - as specified
Resolved 19 May 2010
Resolution: Vessel has been accepted to SFVMAP program. Lifesaving capacity is within compliance.
Engineering › Bilge Water Management System › Manifold
Issued 16 July 2009 Resolved
Repair bilge manifold leak and renew piping with existing hole above stbd bilge pump.
Due 16 August 2009
Resolved 13 August 2010
Resolution: Manifold & piping have been repaired and properly tested
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 14 June 2008 Resolved
Repair/replace port MDE. While backing down, sea water entered port exhaust piping and reached the port MDE causing hydrolock and damage to engine. Vessel authorized to continue operations, with restrictions (see Activity narrative).
Action required: 705 - Other - as specified
Due 22 September 2008
Resolved 12 September 2008
Fire Fighting › Combustible Materials › Insulation
Issued 28 May 2008 Resolved
Renew lagging for exhaust piping for both P&S main engines, between engines and cooling water injection point.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Operations/Management › Pollution › Retention of Oily Mixture
Issued 28 May 2008 Resolved
Remove oily water in E/R and generator room bilges.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 18 June 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 28 May 2008 Resolved
Repair leaking cooling water hose (pedro) on stbd main engine.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Operations/Management › Pollution › Retention of Oily Mixture
Issued 28 May 2008 Resolved
Repair leaking hydraulic line in forepeak.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 May 2008 Resolved
Provide an additional (6) adult Type-1 PFDs (5 condemned, 1 missing).
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 May 2008 Resolved
Replace expired EPIRB battery.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 18 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008 Resolved
Use, remove, or terminate dead-end wires under bridge console and replace cracked electrical junction box cover.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 May 2008 Resolved
Prove proper operation of audible and visual bilge alarms in all required spaces.
Action required: 705 - Other - as specified
Due 28 June 2008
Resolved 29 May 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 31 May 2007 Resolved
Provide proper bulkhead penetration valves for PVC galley sink lines penetrating WT bulkhead separating the galley and sewage tank void.
Due 11 July 2007
Resolved 11 July 2007
Resolution: One line was not in use and capped off, the 2nd line had valves installed.
Construction/Loadline › Hull › Hull Plating
Issued 31 May 2007 Resolved
Provide proper closure devices on starboard side sponson access penetrations (remove wood DC plugs). Correct prior to receiving credit dry-dock.
Due 1 February 2008
Resolved 11 July 2007
Resolution: Welded new threaded flanges with threaded plugs.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 1 June 2006 Resolved
Provide IBA's onboard per COI. Vessel restricted to LBS route until corrected.
Due 21 June 2006
Resolved 21 June 2006
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2006 Resolved
Update/currently correct all marine charts, light list, and coast pilot for areas transisted.
Due 21 June 2006
Resolved 21 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 June 2006 Resolved
Replace 10 lifejackets and ensure total onboard equals 275. Vessel restricted to not more than 265 total persons until corrected.
Due 21 June 2006
Resolved 21 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 June 2006 Resolved
Replace/repair retro-reflective tape on approx 60 lifejackets.
Due 21 June 2006
Resolved 21 June 2006
Fire Fighting › Grease Extraction Hood › General
Issued 1 June 2006 Resolved
Clean galley hood and ducting.
Due 21 June 2006
Resolved 21 June 2006
Pollution Prevention/Response › Prevention Equipment
Issued 23 December 2003 Resolved
Seal grey and black water tanks. Remove wooden tank top from tank in forward compartment. Remove liquid from bilges. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 June 2003 Resolved
Install cover on outlet in port side engineroom.
Due 24 June 2003
Resolved 17 June 2003
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 June 2003 Resolved
Place cover on junction box under console on bridge.
Due 24 June 2003
Resolved 17 June 2003
Engineering › Sea-water System (primary cooling) › Pump
Issued 17 June 2003 Resolved
Mount pump in stbd forward engineroom.
Due 24 June 2003
Resolved 17 June 2003
Electrical › Lighting (emergency)
Issued 3 June 2002 Resolved
Show proper operation of emergy lighting system.
Condition: Improper/Lack of Maintenance
Due 3 July 2002
Resolved 8 July 2002
Construction/Loadline › Structures
Issued 3 June 2002 Resolved
Re-attach hatch cover to fore peak. LEGACY COMPONENT DESC: Scuttle
Due 3 July 2002
Resolved 8 July 2002
Construction/Loadline › Structures
Issued 3 June 2002 Resolved
Re-attach ladder to fore peak. LEGACY COMPONENT DESC: Trunk
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 June 2002 Resolved
Clean oil residue from engines.
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 June 2002 Resolved
Repair salt water leak on exhaust system for center engine. LEGACY COMPONENT DESC: Piping (exhaust)
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-electric)
Issued 3 June 2002 Resolved
Replace pedro hose on starb gen. sea suction.
Due 3 July 2002
Resolved 8 July 2002
Electrical › Electric Generation Source (service)
Issued 3 June 2002 Resolved
Repair frayed wire on port gen. sending unit.
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 June 2002 Resolved
Re-torque all motor mount bolts.
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 June 2002 Resolved
Re-torque all hose clamps on engine exhaust systems. LEGACY COMPONENT DESC: Piping (exhaust)
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-electric)
Issued 3 June 2002 Resolved
Repair salt water leak on center engine exhaust pipe.
Due 3 July 2002
Resolved 8 July 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 June 2002 Resolved
Replace window on main deck, starb forward.
Due 3 July 2002
Resolved 8 July 2002
Fire Fighting › Fire Pumps
Issued 3 June 2002 Resolved
Repair leak on overboard discharge line. LEGACY COMPONENT DESC: Over board discharge line.
Due 3 July 2002
Resolved 8 July 2002
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 22 January 2002 Resolved
Install exhaust lagging in engineroom
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 29 January 2002
Construction/Loadline › Structures
Issued 22 January 2002 Resolved
Support fractured deck in forepeak LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Due 30 January 2002
Resolved 29 January 2002
Lifesaving
Issued 31 May 2001 Resolved
Clean portside aft adult PFD stowage container and dry PFDs.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Unknown
Issued 31 May 2001 Resolved
Expired medication in first aid kit needs to be replaced.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Documentation
Issued 31 May 2001 Resolved
Provide annual drug program report.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Construction/Loadline
Issued 31 May 2001 Resolved
Provide shutoff valves for (2) through hull penetrations in front of stbd MDE.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Fire Fighting
Issued 31 May 2001 Resolved
Provide remote operation of fire pump from operating station.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Engineering
Issued 31 May 2001 Resolved
Provide sound pipes with openings at least as high as fill pipe openings.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Engineering
Issued 31 May 2001 Resolved
Remove non-metallic fuel hose used as filling hose.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Fire Fighting
Issued 31 May 2001 Resolved
Remove door stops on fire doors at top of stairway leading from galley.
Condition: Unknown
Due 6 June 2001
Resolved 6 June 2001
Lifesaving
Issued 6 June 1998 Resolved
Replace lines on 12 man lifefloats.
Condition: Unknown
Due 6 June 1998
Resolved 6 June 1998
Engineering
Issued 6 June 1998 Resolved
Repair exhaust leak on port main diesel engine.
Condition: Unknown
Due 20 June 1998
Resolved 28 July 1998
Lifesaving
Issued 6 June 1998 Resolved
Provide proper type (orange) ring buoy.
Condition: Unknown
Due 6 June 1998
Resolved 6 June 1998
Electrical
Issued 6 June 1998 Resolved
Install lens cover over light in MSD compartment.
Condition: Unknown
Due 6 June 1998
Resolved 6 June 1998
Lifesaving
Issued 4 May 1998 Resolved
COMPARTMENT ON BOW INCORRECTLY LABELED AS CONTAINING PFD'S.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Lifesaving
Issued 4 May 1998 Resolved
EXCESS OIL IN BILGES
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Engineering
Issued 24 February 1998 Resolved
Repair leaking main diesel engine exhaust on both port and starboard engines.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 24 February 1998 Resolved
Repair and adjust watertight doors to provide a watertight seal.
Condition: Unknown
Due 24 February 1998
Resolved 24 February 1998
Construction/Loadline
Issued 24 February 1998 Resolved
Repair cracked weldment in two generator overboards.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 17 December 1997 Resolved
Renew as original entire bilge piping system.
Condition: Unknown
Due 17 December 1997
Resolved 17 December 1997
Construction/Loadline
Issued 14 October 1997 Resolved
MAKE FORWARD GALLEY BULKHEAD WATERTIGHT
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Construction/Loadline
Issued 14 October 1997 Resolved
MAKE AFT GALLEY BULKHEAD WATERTIGHT.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Engineering
Issued 14 October 1997 Resolved
REPAIR RAW WATER LEAKAGE IN PORT AND STARBOARD MAIN ENGINE EXHAUST COOLING SYSTEM.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Fire Fighting
Issued 22 June 1993 Resolved
REPLACE PRESSURE GAUGE ON FIRE PUMP.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Fire Fighting
Issued 22 June 1993 Resolved
REPAIR SEEPAGE LEAKING FROM THE DISCHARGE PIPING OF THE FIRE PUMP AT THE REDUCING FITTING BY REWELDING.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 22 June 1993 Resolved
REPLACE MANLINES ON PORTSIDE FLOATS INBOARD SIDE AND STBD FLOATS OUTBOARD SIDE.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 22 June 1993 Resolved
REPAIR 12 MAN LIFEFLOAT, MANLINE ATTACTMENT EYES.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Accommodation/Occupational Safety
Issued 16 April 1993 Resolved
REPLACE BROKEN WINDOW.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Navigation
Issued 16 April 1993 Resolved
PROPERLY REPAIR HYDRAULIC PIPING ADJACENT TO GALLEY SPACE AND CLEAN HYDRAULIC OIL THAT HAS SPILLED ONTO OVERHEAD PANELS.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Fire Fighting
Issued 23 June 1992 Resolved
HAVE ALL 3 CO2 FIRE EXTINGUISHERS HYDROSTATICALLY TESTED.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Navigation
Issued 23 June 1992 Resolved
PROVE PROPER OPERATION OF ALL RUDDER ANGLE INDICATORS (3) ON BRIDGE.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Electrical
Issued 23 June 1992 Resolved
PROVIDE COVER FOR ELECTRICAL WIRING PANEL ON PORT WATER HEATER.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Navigation
Issued 23 June 1992 Resolved
PROVIDE NOTICE TO MARINER CORRECTIONS TO CORRESPONDING OPERATING CHARTS.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Lifesaving
Issued 23 June 1992 Resolved
PROVIDE A PHYSICAL BOUNDARY TO SEPARATE CHILD AND ADULT LIFE PRESERVERS IN UPPER DECK STOWAGE AREA.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Deck/Cargo
Issued 23 June 1992 Resolved
REMOVE OR PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Unknown
Issued 23 June 1992 Resolved
INVESTIGATE THE CAUSE OF THE DISCOLORATION (BLACK) ON ALL COPPER AND BRONZEFITTINGS AND PIPING IN THE SEWAGE TANK ROOM.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Navigation
Issued 26 June 1990 Resolved
PROVIDE VESSEL WITH ONE ADDITIONAL ANCHOR.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Engineering
Issued 26 June 1990 Resolved
PROVE OPERATION OF PORT MDE OIL GAUGE ON BRIDGE.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Construction/Loadline
Issued 26 June 1990 Resolved
MAKE PENETRATIONS TO TOP OF PORT AFT ENGINE ROOM BULKHEAD WATERTIGHT.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Electrical
Issued 26 June 1990 Resolved
REMOVE OR PROPERLY DEADEND WIRES UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Electrical
Issued 26 June 1990 Resolved
HARDWIRE OR RELOCATE BATTERY CHARGER TO STBD GENERATOR.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Accommodation/Occupational Safety
Issued 26 June 1990 Resolved
PROVIDE A SAFETY RELIEF VALVE FOR EACH HOT WATER HEATER THAT RELIEVES AT 100 PSI AND 200 DEGREES F.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Electrical
Issued 27 June 1989 Resolved
PROPERLY SECURE BATTERY BOX IN BRIDGE CONSOLE.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Accommodation/Occupational Safety
Issued 27 June 1989 Resolved
PROPERLY LABEL EMERGENCY ESCAPES.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Lifesaving
Issued 15 October 1987 Resolved
SUBMIT A PROPOSAL FOR THE RELOCATION OF LIFEJACKETS SO THAT THEY ARE EVENLYDISPERSED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 15 October 1987
Resolved 15 October 1987
Documentation
Issued 10 August 1987 Resolved
VESSEL SHALL NOT BE PLACED INTO PASSENGER CARRYING SERVICE UNTIL A COAST GUARD STABILITY LETTER AHS BEEN ISSUED AND POSTED IN ACCORDANCE WITH 46 CFR 185.12-1.
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987
Documentation
Issued 10 August 1987 Resolved
HAVE VESSEL'S CERTIFICATE OF DOCUMENTATION CORRECTED TO SHOW THE CORRECT TONNAGES AND LENGTH, BREDTH, AND DEPTH IN ACCORDANCE WITH THE CERTIFICATE OF (RE)ADMEASUREMENT DATED 16JUN87.
Condition: Unknown
Due 10 August 1987
Resolved 10 August 1987

Casualty record · 1

18 June 2008Routine · role: Involved in a Marine Casualty · activity 3747534
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PACIFIC HORNBLOWER (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.