Records from 2008 to 2025. Most recent: inspection, 4 August 2025.
Inspection history · 23
4 August 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8196926
7 July 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8178422
15 April 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116375
16 July 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959488
6 February 2024
Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7861179
27 July 2023
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7751233
16 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7689604
4 May 2022
COI Inspection · Internal Structural Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7444201
4 March 2022
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7397570
14 July 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7249956
26 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7147269
13 July 2020
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005226
6 February 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904313
12 August 2019
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6781049
7 February 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6621312
2 November 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6573611
26 September 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6547155
21 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6545701
25 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6274382
17 July 2017
In-Service Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Plan Review (Other than "T") · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212314
19 September 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6004562
30 July 2016
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962776
14 May 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5880712
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024
Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating, and planking, voids, and ballast, cargo, and fuel oil tanks. MI observed significant pitting in centerline of tank space, ultrasonic test the space to determine hull thickness.
46 CFR 176.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Operator conducted ultra sonic testing and determined hull thickness in area of concern.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 July 2024
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI observed loose port rudder angle indicator being secured by ziptie, make permanent repairs to MI satisfaction.
46 CFR 115.814
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: MI observed sat repair made of permanent installation of port rudder angle indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2024
Resolved
Exhaust gas must not leak from piping or any connections. Both engines and generator had exhaust leaks in engine room, repair to MI satisfaction. 46 CFR 119.430 (b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Vessel operator took apart affect areas with exhaust leaks, reinstalled tightning areas, and conducted soap test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull and its appurtenances, including the following; inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. MI observed 3 cracks in 3 different welds in starboard forepeak top of frame 4. Make permanent repairs to MI satisfaction prior to next credit drydock.
46 CFR 115.802
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified repaired welds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2024
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. 01 KAPOK PFD found UNSAT for continued use. Replace PFD to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Operator replaced old PFD with new PFD.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2024
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route. Bottom starboard window allowed water intrusion with wood damage, repair to MI satisfaction.
46 CFR 116.1020
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Operator replaced old deteriorated wood in damaged area and affected permanent.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024
Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating, and planking, voids, and ballast, cargo, and fuel oil tanks. Operator conducted
ultrasonic testing in centerline of forward void tank space identifying areas containing more than 25% wastage. Clean affected areas identified by ultra-sonic test report marked red and apply corrosion resistant protective compound to MI satisfaction. Operator must submit repair plan to be approved by attending marine inspector prior to 28FEB2025 to receive next credit dry dock.
46 CFR 176.610
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified permanent repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024
Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel has opted to not haul out and conduct repairs as previously agreed upon from prior annual inspection. Vessel is restricted from passenger carriage until all repairs are made to the satisfaction of the Marine Inspector.
46 CFR 115.500(b)(1)(iii)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024
Resolved
A drydock examination conducted in compliance with § 115.600 of this part must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Vessel conducted its drydock inspection on 06FEB2024, but has not been able to complete the required worklist items in a timely fashion. Vessel is not allowed to carry passengers until drydock worklist is completed.
46CFR115.610(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2024
Resolution: completed worklist items for dry dock
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child life jackets are not mistaken for adult life jackets. Adult and Child life jackets in stowage compartment near pilothouse are not appropriately separated and marked. Provide provisions for proper storage and marking to satisfaction of Marine Inspector.
46 CFR 117.78 (a) (5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 10 August 2023
Resolution: Separated child sized life preservers from adults.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket storage areas throughout vessel are improperly marked with number of life jackets inside. Ensure markings correspond with correct number of life jackets in each compartment to satisfaction of Marine Inspector.
46 CFR 122.604 (f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 24 August 2023
Resolution: Markings provided via photos.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 May 2023
Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter no later than the month and year on its servicing sticker affixed. Vessel's IBA is expired for servicing.
46 CFR 122.730(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 7 June 2023
Resolution: IBAs serviced. Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023
Resolved
Kerosene are prohibited for cooking, heating, or lighting on ferry or passenger vessels. Multiple kerosene heaters/lights were found on the vessel. Remove kerosene heaters/lights to the satisfaction of the attending marine inspector.
46 CFR 147.50(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 7 June 2023
Resolution: Kerosene equipments removed from vessel. Sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 May 2022
Resolved
An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hooks bolts is considered open to the weather if battening, caulking, or gaskets of any material are not used. Aft tonnage door on stern main deck caulked on outside and covered inside with paneling preventing its removal. Repair by next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 7 July 2025
Resolution: MI verified removal of caulking from aft tonnage opening.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 May 2022
No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspections of the hull structure including the following: inspection of all accessible parts of the exterior of the hull, the watertight bulkheads, and weather decks. Tank void aft starboard outboard bulkhead found with 3" horizontal fracture located 5" beneath overhead. Monitor condition of fracture through August 4 2022. If fracture has not progressed, repair at next credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 August 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2020
Resolved
At least one ring buoy must be fitted with a floating waterlight. Discovered expired battery on ring buoy waterlight on stbd bridge wing. Vessel operations restricted to daytime operations only. 46 CFR 117.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2020
Resolved 27 July 2020
Resolution: Received documentation depicting properly installed battery for operational waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020
Resolved
Each life jacket must be marked with Type I retroreflective material. (17) Adult life jackets identified with worn retroreflective tape that requires replacement.46 CFR 122.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 27 July 2020
Resolution: Received documentation from operator depicting properly affixed new retroreflective material on noted PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020
Resolved
Each life jacket kept in a stowage container must be readily available. Discovered broken hinges on PFD stowage compartment on second deck, fwd of pilothouse. 46 CFR 117.78(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 27 August 2020
Resolution: Received electronic documentation of properly replaced PFD storage hinges.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Working spaces)
Issued 13 July 2020
Resolved
Each lighting fixture must have a guard. No light guard was present on second deck soda locker overhead light.46 CFR 120.410 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 27 August 2020
Resolution: Received electronic verification of properly affixed light guard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020
Resolved
The person in command of a documented vessel must have onboard that vessel the original Certificate of Documentation currently in effect for that vessel. The vessel does not have a Certificate of Documentation onboard.46 CFR 67.313
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 17 July 2020
Resolution: Received documentation from vessel rep with renewed COD.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2020
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. Vessel's fire pump was not able to achieve a pressure of 60 pounds per square inch at the pump outlet. 46 CFR 181.10-1(c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 4 May 2022
Resolution: Witnessed sat testing of fire pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 July 2020
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends 305 millimeters (12 inches) above the weather deck. Forward hatch coaming has several drilled holes, rendering hatch not weathertight.46 CFR 116.1160(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 4 March 2022
Resolution: Operator repaired area where holes were present. Satisfactory weathertight hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 September 2018
Resolved
46CFR 170.270(e) - For each watertight door, an indicator must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. Watertight door leading to lazarette is missing appropriate indicator at operating station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 9 October 2018
Resolution: QAWTD indicator at operating station verified to operate satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2018
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Stowed so that when the vessel sinks the survival craft floats free and inflates automatically. Survival craft stowed with painter line not secured to float-free link. Painter line left unsecured, craft would not auto inflate.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 September 2018
Resolved 27 September 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018
Resolved
AIS PLACEMENT NOT PROVIDED: incomplete dimension information (AIS Antenna Position “X” equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 May 2022
Resolution: Witnessed proper display of outstanding AIS info.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2017
Resolved
Remove hanging light mounted to the wall near ice chest; 120 V without grounding pol
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed hanging lights near ice chest.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 September 2017
Resolved
provide cover in overhead light near ice chest in lower bar area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Provided cover for light.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2017
Resolved
Remove track lighting (120v) in bar area replace with lighting utilizing a grounding pole (3 prong)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed track lighting.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 September 2017
Resolved
Replace trash cans with metallic bins
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: New metallic bins were ordered for the vessel.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 September 2017
Resolved
Remove ext. cord in bar
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed extension cords.
Engineering › Pressure Vessel › Weld
Issued 25 September 2017
Resolved
Hydrostatically test the stbd compressor or remove from service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Disconnected the air compressor and will not be using it.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 September 2017
Resolved
provide ammonia inhalants in first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Provided new ammonia inhalants
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 25 September 2017
Resolved
replace lagging in generator room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Replaced lagging in generator room.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 September 2017
Resolved
Seal exposed wiring at fridge outlet
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Seal exposed wires at the fridge outlet.
Construction/Loadline › Penetrations › Valve Flange
Issued 17 July 2017
Resolved
Replace raw water overboard valve assembly #2 due to wear in ball valve (see DOCUMENTS tab).
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 23 August 2017
Resolution: Marine Inspector visited vessel and ensured raw water overboard valve assembly was replaced.
Construction/Loadline › Hull › Side Shell
Issued 17 July 2017
Resolved
Repair starboard side sponson and make watertight; ensure watertight integrity via pressure test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 23 August 2017
Resolution: Marine Inspector visited vessel and witnessed satisfactory repairs and pressure test.