CAPITAL COMMODORE

CAPITAL COMMODORE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in August 2025, along with 36 deficiencies — 1 with no resolution recorded —, 3 operational controls and 1 casualty investigation in 2008.

Records from 2008 to 2025. Most recent: inspection, 4 August 2025.

Built
1982
Last inspected
4 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2025
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBR2335
Flag
UNITED STATES
Maury page id
psix-54373

Documentation record

Registered dimensions (L × B × D)97.2 ft × 23.0 ft × 7.4 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC. · PATTERSON, LA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSACRAMENTO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

4 August 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8196926
7 July 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8178422
15 April 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8116375
16 July 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7959488
6 February 2024 Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7861179
27 July 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7751233
16 May 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7689604
4 May 2022 COI Inspection · Internal Structural Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7444201
4 March 2022 Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7397570
14 July 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7249956
26 February 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7147269
13 July 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7005226
6 February 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904313
12 August 2019 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6781049
7 February 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6621312
2 November 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6573611
26 September 2018 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6547155
21 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6545701
25 September 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6274382
17 July 2017 In-Service Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Plan Review (Other than "T") · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6212314
19 September 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6004562
30 July 2016 Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962776
14 May 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5880712

Deficiency record · 36

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating, and planking, voids, and ballast, cargo, and fuel oil tanks. MI observed significant pitting in centerline of tank space, ultrasonic test the space to determine hull thickness. 46 CFR 176.610
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 August 2024
Resolution: Operator conducted ultra sonic testing and determined hull thickness in area of concern.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 16 July 2024 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI observed loose port rudder angle indicator being secured by ziptie, make permanent repairs to MI satisfaction. 46 CFR 115.814
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: MI observed sat repair made of permanent installation of port rudder angle indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2024 Resolved
Exhaust gas must not leak from piping or any connections. Both engines and generator had exhaust leaks in engine room, repair to MI satisfaction. 46 CFR 119.430 (b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Vessel operator took apart affect areas with exhaust leaks, reinstalled tightning areas, and conducted soap test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull and its appurtenances, including the following; inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. MI observed 3 cracks in 3 different welds in starboard forepeak top of frame 4. Make permanent repairs to MI satisfaction prior to next credit drydock. 46 CFR 115.802
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified repaired welds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2024 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. 01 KAPOK PFD found UNSAT for continued use. Replace PFD to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Operator replaced old PFD with new PFD.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2024 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route. Bottom starboard window allowed water intrusion with wood damage, repair to MI satisfaction. 46 CFR 116.1020
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Operator replaced old deteriorated wood in damaged area and affected permanent.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat or out of the water and consists of a complete examination of the vessel’s main strength members, including the major internal framing, the hull plating, and planking, voids, and ballast, cargo, and fuel oil tanks. Operator conducted ultrasonic testing in centerline of forward void tank space identifying areas containing more than 25% wastage. Clean affected areas identified by ultra-sonic test report marked red and apply corrosion resistant protective compound to MI satisfaction. Operator must submit repair plan to be approved by attending marine inspector prior to 28FEB2025 to receive next credit dry dock. 46 CFR 176.610
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified permanent repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2024 Resolved
If the annual inspection reveals deficiencies in your vessel's maintenance, you must make any or all repairs or improvements within the time period specified by the OCMI. Vessel has opted to not haul out and conduct repairs as previously agreed upon from prior annual inspection. Vessel is restricted from passenger carriage until all repairs are made to the satisfaction of the Marine Inspector. 46 CFR 115.500(b)(1)(iii)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 July 2026
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2024 Resolved
A drydock examination conducted in compliance with § 115.600 of this part must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Vessel conducted its drydock inspection on 06FEB2024, but has not been able to complete the required worklist items in a timely fashion. Vessel is not allowed to carry passengers until drydock worklist is completed. 46CFR115.610(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2024
Resolution: completed worklist items for dry dock
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child life jackets are not mistaken for adult life jackets. Adult and Child life jackets in stowage compartment near pilothouse are not appropriately separated and marked. Provide provisions for proper storage and marking to satisfaction of Marine Inspector. 46 CFR 117.78 (a) (5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 10 August 2023
Resolution: Separated child sized life preservers from adults.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket storage areas throughout vessel are improperly marked with number of life jackets inside. Ensure markings correspond with correct number of life jackets in each compartment to satisfaction of Marine Inspector. 46 CFR 122.604 (f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2023
Resolved 24 August 2023
Resolution: Markings provided via photos.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 May 2023 Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151, of this chapter no later than the month and year on its servicing sticker affixed. Vessel's IBA is expired for servicing. 46 CFR 122.730(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 7 June 2023
Resolution: IBAs serviced. Sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2023 Resolved
Kerosene are prohibited for cooking, heating, or lighting on ferry or passenger vessels. Multiple kerosene heaters/lights were found on the vessel. Remove kerosene heaters/lights to the satisfaction of the attending marine inspector. 46 CFR 147.50(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 7 June 2023
Resolution: Kerosene equipments removed from vessel. Sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 May 2022 Resolved
An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hooks bolts is considered open to the weather if battening, caulking, or gaskets of any material are not used. Aft tonnage door on stern main deck caulked on outside and covered inside with paneling preventing its removal. Repair by next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2024
Resolved 7 July 2025
Resolution: MI verified removal of caulking from aft tonnage opening.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 May 2022 No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to have the vessel ready for inspections of the hull structure including the following: inspection of all accessible parts of the exterior of the hull, the watertight bulkheads, and weather decks. Tank void aft starboard outboard bulkhead found with 3" horizontal fracture located 5" beneath overhead. Monitor condition of fracture through August 4 2022. If fracture has not progressed, repair at next credit drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 August 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2020 Resolved
At least one ring buoy must be fitted with a floating waterlight. Discovered expired battery on ring buoy waterlight on stbd bridge wing. Vessel operations restricted to daytime operations only. 46 CFR 117.70(d)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2020
Resolved 27 July 2020
Resolution: Received documentation depicting properly installed battery for operational waterlight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020 Resolved
Each life jacket must be marked with Type I retroreflective material. (17) Adult life jackets identified with worn retroreflective tape that requires replacement.46 CFR 122.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2020
Resolved 27 July 2020
Resolution: Received documentation from operator depicting properly affixed new retroreflective material on noted PFDs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2020 Resolved
Each life jacket kept in a stowage container must be readily available. Discovered broken hinges on PFD stowage compartment on second deck, fwd of pilothouse. 46 CFR 117.78(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 27 August 2020
Resolution: Received electronic documentation of properly replaced PFD storage hinges.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Lighting (Working spaces)
Issued 13 July 2020 Resolved
Each lighting fixture must have a guard. No light guard was present on second deck soda locker overhead light.46 CFR 120.410 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 27 August 2020
Resolution: Received electronic verification of properly affixed light guard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020 Resolved
The person in command of a documented vessel must have onboard that vessel the original Certificate of Documentation currently in effect for that vessel. The vessel does not have a Certificate of Documentation onboard.46 CFR 67.313
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 17 July 2020
Resolution: Received documentation from vessel rep with renewed COD.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 July 2020 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. Vessel's fire pump was not able to achieve a pressure of 60 pounds per square inch at the pump outlet. 46 CFR 181.10-1(c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2020
Resolved 4 May 2022
Resolution: Witnessed sat testing of fire pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 July 2020 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: (1) A hatch on a watertight trunk that extends 305 millimeters (12 inches) above the weather deck. Forward hatch coaming has several drilled holes, rendering hatch not weathertight.46 CFR 116.1160(a)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2020
Resolved 4 March 2022
Resolution: Operator repaired area where holes were present. Satisfactory weathertight hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 September 2018 Resolved
46CFR 170.270(e) - For each watertight door, an indicator must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. Watertight door leading to lazarette is missing appropriate indicator at operating station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 9 October 2018
Resolution: QAWTD indicator at operating station verified to operate satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2018 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. Stowed so that when the vessel sinks the survival craft floats free and inflates automatically. Survival craft stowed with painter line not secured to float-free link. Painter line left unsecured, craft would not auto inflate.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 September 2018
Resolved 27 September 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018 Resolved
AIS PLACEMENT NOT PROVIDED: incomplete dimension information (AIS Antenna Position “X” equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 May 2022
Resolution: Witnessed proper display of outstanding AIS info.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2017 Resolved
Remove hanging light mounted to the wall near ice chest; 120 V without grounding pol
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed hanging lights near ice chest.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 September 2017 Resolved
provide cover in overhead light near ice chest in lower bar area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Provided cover for light.
Electrical › Lighting (service) › Grounding Conductor
Issued 25 September 2017 Resolved
Remove track lighting (120v) in bar area replace with lighting utilizing a grounding pole (3 prong)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed track lighting.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 September 2017 Resolved
Replace trash cans with metallic bins
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: New metallic bins were ordered for the vessel.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 September 2017 Resolved
Remove ext. cord in bar
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Removed extension cords.
Engineering › Pressure Vessel › Weld
Issued 25 September 2017 Resolved
Hydrostatically test the stbd compressor or remove from service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Disconnected the air compressor and will not be using it.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 September 2017 Resolved
provide ammonia inhalants in first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Provided new ammonia inhalants
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 25 September 2017 Resolved
replace lagging in generator room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Replaced lagging in generator room.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 September 2017 Resolved
Seal exposed wiring at fridge outlet
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2017
Resolved 25 October 2017
Resolution: Seal exposed wires at the fridge outlet.
Construction/Loadline › Penetrations › Valve Flange
Issued 17 July 2017 Resolved
Replace raw water overboard valve assembly #2 due to wear in ball valve (see DOCUMENTS tab).
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 23 August 2017
Resolution: Marine Inspector visited vessel and ensured raw water overboard valve assembly was replaced.
Construction/Loadline › Hull › Side Shell
Issued 17 July 2017 Resolved
Repair starboard side sponson and make watertight; ensure watertight integrity via pressure test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 23 August 2017
Resolution: Marine Inspector visited vessel and witnessed satisfactory repairs and pressure test.

Casualty record · 1

18 June 2008Routine · role: Involved in a Marine Casualty · activity 3747534
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PACIFIC HORNBLOWER (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.