Records from 2016 to 2022. Most recent: inspection, 21 April 2022.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 January 2021
No resolution recorded
Rails shall consist of evenly spaced courses and the spacing between courses shall be not greater than 12 inches. Rail courses onboard are greater than 12 inches. 46CFR177.35-1(b).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2021
No resolution recorded
CO2 system connection hose is heavily corroded, must be replaced. Vessel is detained until discrepancy is cleared. 46CFR147.65
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 February 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2021
No resolution recorded
A passenger accomodation space must be maintained to minimize fire hazard. A diesel fired heater was found installed in the bilge of accomodation space. Vessel is detained until discrepancy is cleared. 46CFR177.800(c); 46CFR177.005(d); 46CFR182.410(a).
Condition: Improper Installation
Action required: 30 - Ship detained
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 January 2021
No resolution recorded
Each hatch exposed to weather must be watertight or weathertight if used in conjuction with watertight combing. Fuel valve and engine room hatches were found missing gaskets to form seal. Remove or replace to form sea. 46CFR171.124
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2021
No resolution recorded
Openings in the hull of a vessel must have a shutoff valve. The valve was removed, since the system was decomissioned. Provide a permanent repair or install a valve by July 31, 2021. 46CFR179.350c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2021 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2021
No resolution recorded
Each blade of the propeller was found wasted. Repair or replace the propeller in-kind by Jyly 31, 2021. 46CFR182.05-1
Action required: 705 - Other - as specified
Due 31 July 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2021
No resolution recorded
Mark the fuel oil shutoff valve located on the starboard side in letters at least 1'' high. 46CFR185.608
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 26 January 2021
No resolution recorded
Replace the deteriorated life line on the main deck ring buoy. 46CFR100.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2021
No resolution recorded
Replace deteriorated portable fire extinguisher located on the bridge at at the next annual service, March 2021. 46CFR176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 January 2021
No resolution recorded
Mark the forward escape hatch, "emergency exit, keep clear." 46CFR185.606
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 January 2021
No resolution recorded
Replace the worn main raw water suction line by July 31, 2021. 46CFR182.40-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 May 2020
Resolved
Fixed C02 system cylinder is severely corroded and in a weakened condition. Renew cylinder and install IAW manufacturer instructions. System to be inspected and certified by a third party fire equipment servicing organization.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2020
Resolved 21 May 2020
Resolution: New fully charged Co2 cylinder was provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 October 2019
Resolved
Vessel observed with a barbeque grill on the upper deck and an open flame cook top in the cabin. Deckhouse is constructed with FRP over wood. Resin type is unknown therefore assumed to be general purpose. Cooking appliances on vessels constructed using general purpose resin must be surrounded by B-15 class boundaries. Open flame systems for cooking and heating are prohibited.
46CFR177.410(a),(b), & (c)
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Owner had deck hands remove the barbeque and open flame cooktop from the vessel in the presence of the attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2019
Resolved
Vessel installed a barbeque on the upper deck of an unknown weight. Any changes or modifications that affect the weight of the vessel, invalidate the approved stability letter, thus invalidating the COI.
46CFR176.100(a)
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel's owner had deckhands remove the barbeque grill in the presence of the attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2019
Resolved
Repairs or alterations that affect the safety of the vessel must not be made without submitting a proposal in writing to the OCMI. The OCMI must approve the proposal. Vessel owner/operator must submit all future modifications in writing to the local OCMI.
46CFR176.700(a) & (b)
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel owner verbally educated on the importance of submitting proposals in writing to any modification or alteration that may affect the safety of the vessel. Owner acknowledged the importance.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 January 2019
Resolved
Operator was unable to produce maintenance records for fixed-gas fire extinguishing system; available records indicated service had lapsed beyond tolerance.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2019
Resolved 24 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 23 January 2019
Resolved
There wre several containers of fuel found in the battery stowage area below decks; space was unprotected by fixed-gas system and had no ventilation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 23 January 2019
Resolved
Bilges contained excessive oily-water and debris; potential for clogging bilge pumps or pollution
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: master had crew vaccuum bilges of oily water and clear out debris
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 7 February 2018
Resolved
PORT BANK OF MAIN ENGINE LEAKING OIL EXHAUST AFT. CORRECT OIL/EXHAUST LEAK. PENDING CORRECTION MONITOR AND KEEP WIPED UP ANY OIL ACCUMULATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 2 March 2018
Resolution: RESOLVED
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 29 January 2018
Resolved
No DAPI documentation for deckhand. Provide negative result and consortium enrollment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: DOCUMENTATION PROVIDED.
Lifesaving › Hand Flares › Not on Board
Issued 29 January 2018
Resolved
No orange day smokes on board. Provide valid orange day smoke distress signals (3).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: PROVIDED REQ'D DISTRESS SIGNALS
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 29 January 2018
Resolved
Liferaft(IBA) servicing not completed. Provide servicing documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: IBA FULLY SERVICED.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 January 2018
Resolved
Provide new lifejacket donning placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: New placard placed on vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 January 2018
Resolved
Re-mark lifering on main passenger deck with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: Lifering properly marked with permanent marker.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 January 2018
Resolved
Re-mark lifering on fly bridge with vessel name.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: Lifering properly marked.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2018
Resolved
Battery in water light expired since 2014. Replace water light battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: RESOLVED, NEW BATTERY INSTALLED
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 January 2018
Resolved
Port side nav. light not operable. Repair nav light.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2018
Resolved 3 February 2018
Personnel › Training › First Aid/CPR
Issued 29 January 2018
Resolved
Provide CPR certification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 7 February 2018
Resolution: PROVIDED CPR CARD
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 January 2018
Resolved
Asprin in first aid kit expired. Replace asprin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 7 February 2018
Resolution: RESOLVED, REPLACED EXP. ASPRIN
Operations/Management › Pollution › Retention of Oily Mixture
Issued 29 January 2018
Resolved
Accumulation of oil in engine space exhaust manifold, etc. Excessive, presents fire hazard. Remove, clean. Identify and correct source.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2018
Resolved 7 February 2018
Resolution: RESOLVED, MI ATTENDED DETERMINED LEAK IDENTIFIED AND REPAIRED
Accommodation/Occupational Safety › Heating › Piping
Issued 29 January 2018
Resolved
Insulate exhaust ducting. Near combustible materials, presents fire hazard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2018
Resolved 7 February 2018
Resolution: RESOLVED, MI ATTENDED, VERIFIED REPAIR
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 February 2017
Resolved
Raw water line from heat exchanger to STBD exhaust has soft patch forward and automotive radiator hose flex joint aft, installed with single hose clamp each end. Renew rawater line w/ approved materials and with SAE J1942 hoses and double clamped.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 February 2017
Resolved
Flex joint hose, port raw water line to exhaust single clamped. Double clamp flex joint
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Engineering › Fuel Oil Service System › Hose
Issued 16 February 2017
Resolved
Various fuel hoses installed on M/E not fire rated, hoses include (46 CFR 182.720 (e))
-F/O Hose to and from both cylinder heads
-F/O return to tank from port cylinder head.
-F/O to and from pump
-F/O from primary to secondary spin on filters
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017
Resolved
Dead end wiring behind main operating station and STBD side flying bridge previous running light. Properly terminate/remove dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Lifesaving › Lifebuoys › Serviceable
Issued 16 February 2017
Resolved
Lifering buoy not servicable due to broken fill plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Replaced with new buoy.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 February 2017
Resolved
COD not on board or valid
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2017
Resolved 9 March 2017
Resolution: Contacted NVDC and verified oin MISLE that COD is now valid. Informed operator he can sail, approved by CDV.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2016
Resolved
Provide operable emergency remote fuel shut-off valve for both port fuel tanks. (Old "T") 182.15-40(b)(3)
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 9 February 2016
Resolution: Replaced chain with cable and relocated eyelet.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2016
Resolved
Repair port running light. (New "T") 46 CFR 183.420
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 8 February 2016
Resolution: Repaired port navigation light by adjusting light fixture frame.
Communications › Radio Communications › EPIRB
Issued 8 February 2016
Resolved
Replace old HRU on EPIRB. (Old "T") 46 CFR 180.40-1(a)(3)
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 February 2016
Resolution: Removed EPIRB from vessel (EPIRB not required due to route).
Communications › Radio Communications › EPIRB
Issued 8 February 2016
Resolved
Replace EPIRB battery with new battery. (New "T") 46 CFR 185.726(d)
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 February 2016
Resolution: Removed EPIRB from vessel (EPIRB not required due to route).
Communications › Radio Communications › EPIRB
Issued 8 February 2016
Resolved
Securely mount EPIRB. (Old "T") 46 CFR 180.40-1
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 February 2016
Resolution: Removed EPIRB from vessel (EPIRB not required due to route).
Stability › Watertight Integrity › General
Issued 8 February 2016
Resolved
Provide means to properly secure aft hatch. (Old "T") 46 CFR 185.20-15
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 8 February 2016
Resolution: Repaired aft hatch securing device.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 February 2016
Resolved
Provide proper first aid kit. (New "T") 46 CFR 184.710
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 3 March 2016
Resolution: Verified acquisition of first aid kit.