MAURY USCG vessel records
← All vessels

JOKER

JOKER is a 1967 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in April 2022, along with 44 deficiencies — 11 with no resolution recorded —, 2 operational controls and 1 casualty investigation in 2020.

Records from 2016 to 2022. Most recent: inspection, 21 April 2022.

Built
1967
Last inspected
21 April 2022
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2022
…with no type recorded2
…past their stated due date10
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB3086
Flag
UNITED STATES
Maury page id
psix-54376

Documentation record

Registered dimensions (L × B × D)42.5 ft × 14.0 ft × 6.1 ft
Registered tonnagegross 25 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAKE WASHINGTON SHIP YARD · HOUGHTON, WA, UNITED STATES · built 1967
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ORCHARD, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Net Ton
25 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 44 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

21 April 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435450
15 April 2022 Type not recorded
No type recorded · Station Port Angeles · USCG Northwest District (CGD-NW) · Activity 7431957
26 January 2021 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7131729
20 May 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6956896
9 April 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6937297
8 April 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6937727
30 November 2019 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6864684
30 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830002
19 February 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6626166
23 January 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6613282
29 January 2018 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6343574
22 February 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6092050
16 February 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6102212
8 February 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5810376

Deficiency record · 44

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 January 2021 No resolution recorded
Rails shall consist of evenly spaced courses and the spacing between courses shall be not greater than 12 inches. Rail courses onboard are greater than 12 inches. 46CFR177.35-1(b).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2021 No resolution recorded
CO2 system connection hose is heavily corroded, must be replaced. Vessel is detained until discrepancy is cleared. 46CFR147.65
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 February 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2021 No resolution recorded
A passenger accomodation space must be maintained to minimize fire hazard. A diesel fired heater was found installed in the bilge of accomodation space. Vessel is detained until discrepancy is cleared. 46CFR177.800(c); 46CFR177.005(d); 46CFR182.410(a).
Condition: Improper Installation
Action required: 30 - Ship detained
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 January 2021 No resolution recorded
Each hatch exposed to weather must be watertight or weathertight if used in conjuction with watertight combing. Fuel valve and engine room hatches were found missing gaskets to form seal. Remove or replace to form sea. 46CFR171.124
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 January 2021 No resolution recorded
Openings in the hull of a vessel must have a shutoff valve. The valve was removed, since the system was decomissioned. Provide a permanent repair or install a valve by July 31, 2021. 46CFR179.350c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2021 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 January 2021 No resolution recorded
Each blade of the propeller was found wasted. Repair or replace the propeller in-kind by Jyly 31, 2021. 46CFR182.05-1
Action required: 705 - Other - as specified
Due 31 July 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2021 No resolution recorded
Mark the fuel oil shutoff valve located on the starboard side in letters at least 1'' high. 46CFR185.608
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 26 January 2021 No resolution recorded
Replace the deteriorated life line on the main deck ring buoy. 46CFR100.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 January 2021 No resolution recorded
Replace deteriorated portable fire extinguisher located on the bridge at at the next annual service, March 2021. 46CFR176.810(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2021 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 January 2021 No resolution recorded
Mark the forward escape hatch, "emergency exit, keep clear." 46CFR185.606
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 January 2021 No resolution recorded
Replace the worn main raw water suction line by July 31, 2021. 46CFR182.40-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2021 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 May 2020 Resolved
Fixed C02 system cylinder is severely corroded and in a weakened condition. Renew cylinder and install IAW manufacturer instructions. System to be inspected and certified by a third party fire equipment servicing organization.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2020
Resolved 21 May 2020
Resolution: New fully charged Co2 cylinder was provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 October 2019 Resolved
Vessel observed with a barbeque grill on the upper deck and an open flame cook top in the cabin. Deckhouse is constructed with FRP over wood. Resin type is unknown therefore assumed to be general purpose. Cooking appliances on vessels constructed using general purpose resin must be surrounded by B-15 class boundaries. Open flame systems for cooking and heating are prohibited. 46CFR177.410(a),(b), & (c)
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Owner had deck hands remove the barbeque and open flame cooktop from the vessel in the presence of the attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2019 Resolved
Vessel installed a barbeque on the upper deck of an unknown weight. Any changes or modifications that affect the weight of the vessel, invalidate the approved stability letter, thus invalidating the COI. 46CFR176.100(a)
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel's owner had deckhands remove the barbeque grill in the presence of the attending marine inspectors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2019 Resolved
Repairs or alterations that affect the safety of the vessel must not be made without submitting a proposal in writing to the OCMI. The OCMI must approve the proposal. Vessel owner/operator must submit all future modifications in writing to the local OCMI. 46CFR176.700(a) & (b)
Action required: 10 - Deficiency Rectified
Due 4 October 2019
Resolved 4 October 2019
Resolution: Vessel owner verbally educated on the importance of submitting proposals in writing to any modification or alteration that may affect the safety of the vessel. Owner acknowledged the importance.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 January 2019 Resolved
Operator was unable to produce maintenance records for fixed-gas fire extinguishing system; available records indicated service had lapsed beyond tolerance.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2019
Resolved 24 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 23 January 2019 Resolved
There wre several containers of fuel found in the battery stowage area below decks; space was unprotected by fixed-gas system and had no ventilation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 23 January 2019 Resolved
Bilges contained excessive oily-water and debris; potential for clogging bilge pumps or pollution
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 23 January 2019
Resolution: master had crew vaccuum bilges of oily water and clear out debris
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 7 February 2018 Resolved
PORT BANK OF MAIN ENGINE LEAKING OIL EXHAUST AFT. CORRECT OIL/EXHAUST LEAK. PENDING CORRECTION MONITOR AND KEEP WIPED UP ANY OIL ACCUMULATION.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 2 March 2018
Resolution: RESOLVED
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 29 January 2018 Resolved
No DAPI documentation for deckhand. Provide negative result and consortium enrollment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: DOCUMENTATION PROVIDED.
Lifesaving › Hand Flares › Not on Board
Issued 29 January 2018 Resolved
No orange day smokes on board. Provide valid orange day smoke distress signals (3).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: PROVIDED REQ'D DISTRESS SIGNALS
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 29 January 2018 Resolved
Liferaft(IBA) servicing not completed. Provide servicing documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: IBA FULLY SERVICED.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 January 2018 Resolved
Provide new lifejacket donning placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: New placard placed on vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 January 2018 Resolved
Re-mark lifering on main passenger deck with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: Lifering properly marked with permanent marker.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 January 2018 Resolved
Re-mark lifering on fly bridge with vessel name.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 29 January 2018
Resolution: Lifering properly marked.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2018 Resolved
Battery in water light expired since 2014. Replace water light battery.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 February 2018
Resolution: RESOLVED, NEW BATTERY INSTALLED
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 January 2018 Resolved
Port side nav. light not operable. Repair nav light.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2018
Resolved 3 February 2018
Personnel › Training › First Aid/CPR
Issued 29 January 2018 Resolved
Provide CPR certification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 7 February 2018
Resolution: PROVIDED CPR CARD
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 January 2018 Resolved
Asprin in first aid kit expired. Replace asprin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 7 February 2018
Resolution: RESOLVED, REPLACED EXP. ASPRIN
Operations/Management › Pollution › Retention of Oily Mixture
Issued 29 January 2018 Resolved
Accumulation of oil in engine space exhaust manifold, etc. Excessive, presents fire hazard. Remove, clean. Identify and correct source.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2018
Resolved 7 February 2018
Resolution: RESOLVED, MI ATTENDED DETERMINED LEAK IDENTIFIED AND REPAIRED
Accommodation/Occupational Safety › Heating › Piping
Issued 29 January 2018 Resolved
Insulate exhaust ducting. Near combustible materials, presents fire hazard.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 29 January 2018
Resolved 7 February 2018
Resolution: RESOLVED, MI ATTENDED, VERIFIED REPAIR
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 February 2017 Resolved
Raw water line from heat exchanger to STBD exhaust has soft patch forward and automotive radiator hose flex joint aft, installed with single hose clamp each end. Renew rawater line w/ approved materials and with SAE J1942 hoses and double clamped.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 February 2017 Resolved
Flex joint hose, port raw water line to exhaust single clamped. Double clamp flex joint
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Engineering › Fuel Oil Service System › Hose
Issued 16 February 2017 Resolved
Various fuel hoses installed on M/E not fire rated, hoses include (46 CFR 182.720 (e)) -F/O Hose to and from both cylinder heads -F/O return to tank from port cylinder head. -F/O to and from pump -F/O from primary to secondary spin on filters
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017 Resolved
Dead end wiring behind main operating station and STBD side flying bridge previous running light. Properly terminate/remove dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 10 March 2017
Lifesaving › Lifebuoys › Serviceable
Issued 16 February 2017 Resolved
Lifering buoy not servicable due to broken fill plug.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Replaced with new buoy.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 February 2017 Resolved
COD not on board or valid
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2017
Resolved 9 March 2017
Resolution: Contacted NVDC and verified oin MISLE that COD is now valid. Informed operator he can sail, approved by CDV.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 February 2016 Resolved
Provide operable emergency remote fuel shut-off valve for both port fuel tanks. (Old "T") 182.15-40(b)(3)
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 9 February 2016
Resolution: Replaced chain with cable and relocated eyelet.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 February 2016 Resolved
Repair port running light. (New "T") 46 CFR 183.420
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 8 February 2016
Resolution: Repaired port navigation light by adjusting light fixture frame.
Communications › Radio Communications › EPIRB
Issued 8 February 2016 Resolved
Replace old HRU on EPIRB. (Old "T") 46 CFR 180.40-1(a)(3)
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 February 2016
Resolution: Removed EPIRB from vessel (EPIRB not required due to route).
Communications › Radio Communications › EPIRB
Issued 8 February 2016 Resolved
Replace EPIRB battery with new battery. (New "T") 46 CFR 185.726(d)
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 February 2016
Resolution: Removed EPIRB from vessel (EPIRB not required due to route).
Communications › Radio Communications › EPIRB
Issued 8 February 2016 Resolved
Securely mount EPIRB. (Old "T") 46 CFR 180.40-1
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 15 February 2016
Resolution: Removed EPIRB from vessel (EPIRB not required due to route).
Stability › Watertight Integrity › General
Issued 8 February 2016 Resolved
Provide means to properly secure aft hatch. (Old "T") 46 CFR 185.20-15
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 8 February 2016
Resolution: Repaired aft hatch securing device.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 February 2016 Resolved
Provide proper first aid kit. (New "T") 46 CFR 184.710
Action required: 705 - Other - as specified
Due 15 February 2016
Resolved 3 March 2016
Resolution: Verified acquisition of first aid kit.

Casualty record · 1

8 April 2020Routine · role: Involved in a Marine Casualty · activity 6937727
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.