MAURY USCG vessel records
← All vessels

CBR 100

Built
1981
Last inspected
20 September 2017
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 20 September 2017
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1983–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-54388

Documentation record

Tonnage as PSIX records it382 - Regulatory (Subpart C or D), Net Ton
382 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 44 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 44

20 September 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6270867
30 June 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5924635
17 August 2015 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5219269
28 November 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5036362
26 September 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5005786
5 August 2013 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4675644
12 July 2012 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4376384
10 August 2010 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3816337
10 July 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3530155
5 January 2009 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3389026
14 January 2008 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3130218
28 August 2007 Deficiency Check · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3041203
30 October 2006 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2810631
30 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2504747
13 September 2005 Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 2491391
16 August 2005 Damage Survey · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2474127
14 June 2005 MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390668
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999131
14 January 2004 Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1984323
3 December 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1958291
24 October 2003 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1935303
14 August 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1661296
2 October 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418980
16 August 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393743
3 November 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455776
20 January 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395092
19 August 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472916
11 August 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390587
17 August 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377844
10 January 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880808
19 September 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414363
16 November 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161606
21 October 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403558
15 October 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1245398
12 December 1991 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957146
9 November 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 995392
18 January 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216839
30 November 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209453
10 November 1988 Hull Examination · COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209448
31 December 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316199
31 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299906
11 September 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990524
19 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979107
14 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967212

Deficiency record · 8

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 December 2008 Resolved
Per reg 33 CFR 155.1045(i), the TVRP must amend the geographic-specific appendix for the Mobile Bay Drilling Area to include notification to the state of Louisiana.
Due 10 January 2009
Resolved 22 July 2009
Resolution: Plan holder amended the TVRP to include the proper notification. Deficiency closed. TVRP expires 12/02/2013
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 August 2007 Resolved
Draft marks were not in contrasting colors with the vessels hull. Repaint draft marks.
Condition: Improper/Lack of Maintenance
Due 4 September 2007
Resolved 29 August 2007
Engineering › Diesel Engine (auxiliary) › Valve
Issued 28 August 2007 Resolved
The cargo pumps prime mover emergency shutdown cable broke during emergency shutdown test. Replace emergency shut-down cable.
Condition: Unknown
Due 4 September 2007
Resolved 29 August 2007
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 28 August 2007 Resolved
Flames screens on all 4 cargo tank goose neck vents were wasted. Replace all flame screens.
Condition: Unknown
Due 4 September 2007
Resolved 29 August 2007
Deck/Cargo
Issued 15 October 1992 Resolved
REPLACE 6 IN. DRESSLER COUPLING AND 6 IN. BUTTERFLY VALVE ON CARGO PIPING AT CENTER SECTION OVERHEAD BETWEEN CARGO PUMPS. HYDRO TEST IN PRESENCE OF COAST GUARD MARINE INSPECTOR AT 1 1/2 TIMES THE MAWP.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Deck/Cargo
Issued 15 October 1992 Resolved
PROVE PROPER OPERATION OF BOTH CARGO PUMPS AND EMERGENCY SHUT-DOWNS IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Deck/Cargo
Issued 15 October 1992 Resolved
REPLACE/PERMANENTLY REPAIR UPPER 2 1/2 IN. CARGO PIPING FROM 6 IN. HEADER TO BUTTERFLY VALVE (PORT/STBD SIDES/ALL (12) TWELVE SECTIONS) AND FROM BUTTERFLY TO 90 DEGREES ELBOW. REPAIRS TO BE MADE TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Deck/Cargo
Issued 15 October 1992 Resolved
HYDRO TEST CARGO PIPING TO 1 1/2 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE AFTER REPAIRS TO ITEMS #2 AND #3 IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992

Ownership record