← All vessels
SIGLOO POLAR
SIGLOO POLAR is a tank ship. The Coast Guard has recorded 56 inspections since 1985, most recently in April 2009, along with 26 deficiencies and 10 operational controls.
Records from 1985 to 2009. Most recent: inspection, 19 April 2009.
- Built
- Not recorded
- Last inspected
- 19 April 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8107141 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LLQP3
54398
Flag
NORWAY
—
Maury page id
psix-54398
Inspections, by type
…with no type recorded32
Years with a record
20 calendar years (1985–2009)
The 56 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8878 - Regulatory (Subpart C or D), Gross Ton
2663 - Regulatory (Subpart C or D), Net Ton
12426 - Dead Weight, Ton
2663 - Regulatory (Subpart C or D), Net Ton
12426 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 56
19 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3452668
27 February 2009
COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3424921
8 October 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3340884
26 August 2008
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3309617
9 April 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3180568
29 February 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · COC-GAS Renew · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3156014
4 December 2007
PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3109476
11 May 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2928078
6 April 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2902872
20 February 2007
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2874749
5 February 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2867467
3 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2849519
15 October 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2800947
22 June 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2688435
8 June 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2673992
16 February 2006
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2586886
17 August 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2168873
23 February 2004
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2011629
21 February 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2011706
17 August 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292980
7 July 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292610
10 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275645
10 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 436045
10 March 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1047390
19 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 428800
19 May 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 797658
27 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412164
27 January 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1118594
19 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411860
20 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403856
13 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403584
31 January 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 399919
29 February 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 388282
29 February 1996
MARPOL Annex I Examination · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1387941
23 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 384158
9 May 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 378476
4 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 437076
1 July 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 368290
1 July 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1164982
9 May 1994
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1168979
1 February 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853706
29 November 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 646787
23 November 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 534251
23 November 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1452994
23 August 1993
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 846693
3 June 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135468
8 February 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 826389
8 February 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1271065
3 October 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 464802
3 October 1990
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 907963
2 July 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 509151
20 December 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 907292
28 November 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 472069
24 October 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1327402
10 October 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1323652
25 March 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1290595
Deficiency record · 26
Fire Fighting › Fire Main › Condition
Issued 29 February 2008
Resolved
Vessel has damage on the main line of the fire monitor. Vessel shall submit a report attesting to temporary repairs as well as a condition of class.
Lifesaving › Lifebuoys › Stowage
Issued 29 February 2008
Resolved
Vessel's quick release lifebuoys on Port and Starboard side are not capable of quick release from the bridge due to deterioration and rust.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 20 February 2007
Resolved
Vessel's High Level Alarms are inoperable. The vessel must verify the High Level Alarms on all the tanks are in working order and submit a class report attesting to the proper operation prior to loading chemical cargos.
Deck/Cargo › Vapor Control Systems › Remotely Operated Cargo Vapor Shutoff Valve
Issued 20 February 2007
Resolved
Quick closing valves on the vessels vapor lines located on both manifolds are not operating properly. All vapor lines showed intermittent operation. The vessel must have valves serviced prior to loading cargo and submit a class report attesting to their proper repair and operation.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 20 February 2007
Resolved
Deck water spray sprinklers for the accommodation and cargo tank dome #6 are not providing a uniformly distributed water spray. The vessel must make repairs prior to loading cargo and submit a class report attesting to their proper operation.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 January 2007
Resolved
Vessel requset inbound deviation for the secondary marine radar system
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 16 February 2006
Resolved
Vessel's fixed gas detection system is unable to measure gas concentrations of 0-100 per cent by volume in the forecastle, compressor room, and motor room.
Deck/Cargo › Vapor Control Systems
Issued 23 February 2004
Resolved
Vapor collection system (VCS) lines are improperly painted and missing 1 inch stud (46 CFR 39.10-13(d)). Properly paint and replace stud on all vapor lines to the satisfaction of the attending USCG Marine Inspector prior to 07Mar04. LEGACY COMPONENT DESC: Piping/Hoses
Deck/Cargo
Issued 23 February 2004
Resolved
Vessel cannot demonstrate proper operation of its explosive meters. Meters operating improperly. IGC 13.6.6 Repair or replace explosive meters and demonstrate proer operation to the satisfaction of the certificate issuing authority prior to 07Mar04.
Deck/Cargo
Issued 7 July 2001
Resolved
Inert Gas System not functioning properly & unable to test alarms & shut- downs .Repair/prove proper operation of I.G. to the satisfaction of the certificate issuing authority prior to loading cargoes requiring inert gas IAW SOLAS 74 AMENDED CHAPTER II-2 REGULATION 62
Deck/Cargo
Issued 7 July 2001
Resolved
Outer air lock door has no self-closing mechanism. Install to the satisfaction of the certificate issuing authority IAW Gas Carrier Code Chapter III Regulation 3.6
Deck/Cargo
Issued 10 March 2000
Resolved
VENTILATION DUCTS ARE FROZEN SHUT IN COMPRESSOR ROOM IAW BCH III/A. CORRECT TO THE SATISFACTION OF CERTIFICATE ISSUING AUTHORITY PRIOR TO LOADING CARGOES, NLT 10MAR00.
Deck/Cargo
Issued 10 March 2000
Resolved
ON CARGO TANK #4 THE 95% ALARM IS UNOPERABLE IAW BCH & GAS CODE, CORRECT TO THE SATIFACTION OF CERTIFICATE ISSUING AUTHORITY TO LOADING CARGOES IN THAT TANK.
Unknown
Issued 19 May 1999
Resolved
IMPROPER STOWAGE OF PAINT IN FORWARD BOSUN STORE ROOM. SPACE NOT DESIGNATED NOR EQUIPPED WITH EXPLOSION PROOF FITTINGS FOR PAINT STORAGE. PAINT IS TO BE REMOVED AND PROPERLY STOWED PRIOR TO NEXT U.S. VOYAGE, AND NOT LATER THAN 19 JUNE 1999.
Fire Fighting
Issued 27 January 1998
Resolved
Provide Class Society (DNV) report attesting to satisfactory coverage of Deck Water Spray System forward at cargo tanks #1 and 2, compressor room and deckhouse, IAW SOLAS 74 II-2/21.
Navigation
Issued 31 January 1997
Resolved
Install Auto Pilot [name withheld] 33 CFR 157.440 NLT 03Mar97 or next U.S. port.
Deck/Cargo
Issued 31 January 1997
Resolved
Prove proper operation of IGS IAW Chapter 4 of the IMO IGS 1990 Edition to the satisfaction of class (DNV) prior to next onload of cargo, NLT 03Feb97.
Lifesaving
Issued 31 January 1997
Resolved
Provide Annual Service Certificates for SCBA's/EEBA's IAW BCH 3.16.8 NLT 05Feb97. Class issued Condition of Class to correct NLT 04May97
Documentation
Issued 9 May 1994
Resolved
PRIOR TO NEXT U.S. VOYAGE REVISE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH33 CFR 155.750(a) TO INCLUDE ALL REQUIRED INFORMATION BY 33 CFR 155.750(a)-(d).
Documentation
Issued 9 May 1994
Resolved
PROVIDE TABLE 1 MARPOL II INFORMATION IN P&A MANUAL AS REQUIRED.
Construction/Loadline
Issued 23 November 1993
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE OIL DISCHARGE MONITOR PRIOR TO CARRYING OIL CARGOES (SYSTEM DISMANTLED).
Deck/Cargo
Issued 23 November 1993
Resolved
OBTAIN COAST GUARD/COMMANDANT APPROVAL (G-MSC) APPROVAL PRIOR TO CARRYING OIL CARGOES IN U.S. WATERS AFTER THE NEXT CARRIAGE OF ACIDS I.A.W. 46CFR153.1052 (VESSEL HAS BEEN CARRYING ACIDS).
Deck/Cargo
Issued 23 November 1993
Resolved
PROVIDE CLASS SOCIETY REPORT OF INSPECTION OF THE COMPRESSOR MOTOR ROOM SHAFT SEALS PRIOR TO THE NEXT USE OF THE COMPRESSORS. (OIL SEALS WERE LEAKING)
Documentation
Issued 3 June 1993
Resolved
SUBMIT VESSEL RESPONSE PLAN TO U. S. COAST GUARD (G-MER-6) AND PLACE REQUIRED SECTIONS ON BOARD.
Lifesaving
Issued 3 June 1993
Resolved
PROVIDE DOCUMENTATION THAT SELF CONTAINED BREATHING APPARATI HAVE BEEN SERVICED WITHIN LAST 12 MONTHS AT FIRST U. S. PORT, NEXT U. S. VOYAGE.
Engineering
Issued 20 December 1989
Resolved
RENEW INCINERATOR OVERBOARD DISCHARGE SEA VALVE
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.