MAURY USCG vessel records Sign in
← All vessels

CRUISN 1

CRUISN 1 is a 1979 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1985, most recently in May 2026, along with 140 deficiencies and 1 casualty investigation in 2009.

Records from 1985 to 2026. Most recent: inspection, 19 May 2026.

Built
1979
Last inspected
19 May 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE4444
Flag
UNITED STATES
367353290
Maury page id
psix-54403

Inspections, by type

…with no type recorded6
Years with a record 40 calendar years (1985–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.6 ft × 8.3 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE, INC. · PANAMA CITY, FL, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portATLANTIC CITY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Net Ton
79 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE4444MMSI 367353290 · active · compulsorily equipped · granted 28 February 2018, expires 1 May 2028
WTN8716MMSI not assigned · expired · compulsorily equipped · granted 4 June 1998, cancelled 22 September 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

19 May 2026 Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8357142
11 February 2026 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8308840
1 December 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8276279
3 April 2025 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8103902
10 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7931168
29 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7831325
10 October 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7806243
18 May 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7692389
22 June 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7484400
17 May 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7454452
5 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7345876
24 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7206314
30 March 2020 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6933327
14 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6855359
7 May 2019 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6678478
30 April 2018 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402262
5 December 2017 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6317906
22 March 2017 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6109815
13 April 2016 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5872386
5 January 2016 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5792108
22 May 2014 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4915209
20 March 2014 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4839239
15 May 2012 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4312933
9 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4204894
19 October 2010 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3874729
14 May 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3474626
3 December 2008 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3365287
22 May 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3213321
15 June 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2940040
9 May 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2641280
13 September 2005 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2492196
7 June 2005 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2382493
11 April 2005 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2329116
19 January 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2276245
10 May 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2080880
20 May 2003 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1796858
13 February 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1751002
26 April 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1616016
23 April 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1062682
6 March 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1058308
19 April 2000 COI Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1048551
20 May 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1190457
25 March 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 791847
29 April 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1124422
20 February 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 779445
30 April 1997 COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108268
20 February 1997 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1106049
10 April 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1385680
18 April 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1145468
12 April 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 924535
2 February 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 847407
22 June 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1022469
10 June 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324599
16 May 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 859212
9 May 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 859058
5 May 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 841274
16 April 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142531
6 May 1992 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 947267
28 June 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1244220
9 May 1991 Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1216102
6 June 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215792
30 April 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 899799
9 May 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 901958
19 August 1988 Deficiency Check · Drydock Extension
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1044173
5 May 1988 COI Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338049
10 November 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026561
2 September 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1312377
25 June 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1011740
22 May 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1335634
24 March 1987 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1018282
16 March 1987 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1016903
20 May 1986 Excursion Permit
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1296494
26 March 1986 Credit Drydock
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 997053
28 January 1986 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 996217
3 May 1985 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1289853

Deficiency record · 140

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 May 2026 Resolved
Each item of survival craft equipment must be of good quality. Vessel's life floats have numerous cracks that need to be repaired. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2026
Resolved 11 June 2026
Resolution: All life floats cracks have been repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 19 May 2026 Resolved
The maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Signage for passengers allowed on the upper deck is incorrect. 46 CFR 185.602
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 4 June 2026
Resolution: Vessel added proper signage for upper deck.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessels has gone past its required dry dock exam date as stated on COI of 30 NOV 25. Complete credit drydock examination prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2026
Resolution: Vessel completed satisfactory Drydock
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 June 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life floats to be serviced or repaired with authorized materials; Painter line/ light to be affixed around the body of each life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2024
Resolution: Verified repair of life float, cleared deficiency accordingly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 May 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had life jacket donning instructions for over the head life jackets, but none posted for the clip front type life jackets on board. Post life jacket donning procedures for new life jackets in vicinity of where they are stowed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 2 June 2023
Resolution: Vessel provided photo of new lifejacket donning placard posted - see documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Two dead end, exposed, wires were hanging out of the top of the operation station. Remove wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 2 June 2023
Resolution: Vessel provided photo evidence of hazardous electrical wiring removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2022 Resolved
Vessel's crew unable to satisfactorily complete man overboard drills to the satisfaction of the USCG. Vessel to implement an extra roving watch until drills can be witnessed on 3JUNE2022. 46 CFR 185.520(a)
Action required: 705 - Other - as specified
Due 17 May 2022
Resolved 3 June 2022
Resolution: Re-attended vsl, crew demonstrated proficient knowledge and displayed safety.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022 Resolved
Emergency fuel shutoffs did not completely close valves when operated. Adjust remote operation for full closure. OLD T 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 3 June 2022
Resolution: VSL added reachrod to fuel shut-offs satisfacotriy showing full closure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2022 Resolved
Alcohol swabs onboard for drug and alcohol program were expired. Replace with new and ready for use swabs. 46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 3 June 2022
Resolution: Replaced expired alcohol swabs
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 May 2022 Resolved
Vessel had one inoperable portable light. Acquire working portable light 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 3 June 2022
Resolution: Aquired working portable light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Generator exhaust pipe has leak located at midpoint section located in steering compartment. Repair/replace section of pipe with leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 18 June 2021
Resolution: Leak was patched.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 May 2021 Resolved
Ten flares (6 red hand flares & 4 orange smoke/red flare) onboard. Add two additional flares to meet requirement for 6 hand red flares (night) and six hand orange smoke (day) signals.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 18 June 2021
Resolution: Flares procured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 May 2021 Resolved
Starboard side railing mount located midships had crack in weld where mounted to top of bulwark. Inspect and repair weld.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 29 June 2021
Resolution: Railing welded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021 Resolved
Extinguisher on main deck outside crew space does not have proper bracket. Install bracket as approved by extinguisher manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2021
Resolution: Extinguisher mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2021 Resolved
Space heater installed on upper deck using exposed twist on wire nuts and not in accordance with spacing required per label on heater. Remove heater and provide installation plans for USCG electrical plan review if re installation is desired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
Resolution: Heater removed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 April 2020 Resolved
Missing 01 required distress signals/flares. Replace with either a Hand Red Flare (Approval series 160.021), Hand Orange Smoke ("160.037), Floating Orange Smoke ("160.022), or a Rocket Parachute Flare ("160.036). Vessel is required to carry 12. 46 CFR 180.68
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2020
Resolved 8 April 2020
Resolution: Jeff showed a receipt from him buying another pack of approved flares
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 April 2020 Resolved
Vessel has 02 VHF radio installations sharing the same circuit breaker. A separate circuit, with over-current protection at the main distribution panel, must be provided for each radio installation. 46 CFR 183.392
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2020
Resolved 8 April 2020
Resolution: Jeff sent a video in showing each VHF radio being powered by seperate circuits
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2019 Resolved
Ensure Coast Guard oversight of repairs to wet exhaust piping.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 January 2020
Resolution: recieved photos showing fit up of stbd side, saw port side in person
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2019 Resolved
Repair/replace intake valve in lazarette, stbd side
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2019
Resolution: Valve has been replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2019 Resolved
Replace expired alcohol testing strips.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 11 May 2019
Resolution: Purchased new testing strips from local vendor.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2018 Resolved
Renew FCC Radio Safety Certificate. 47CFR80.1005
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 15 May 2018
Resolution: The vessel had a technician come out, service their radios and issue a new certificate.
Navigation › Piloting/Steering › Marine Charts
Issued 7 May 2018 Resolved
Provide proof of updated charts
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 15 May 2018
Resolution: Owner updated charts and sent photos.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2018 Resolved
Add MMSI data to DSC Radio. 47CFR80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 7 May 2018
Resolution: MMSI data was added to the radio.
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2018 Resolved
Remove extension cord that goes from engine room to accommodation space. Replace with properly sized boat cable and outlet that is wired into a breaker.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 15 May 2018
Resolution: The extension cord was removed and a perminent cable and outlet was installed.
Construction/Loadline › Hull › Hull Plating
Issued 5 December 2017 Resolved
Grind back to good glass and repair section on port side forward of shaft and section of aft keel.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 12 December 2017
Resolution: Item was repaired
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 5 December 2017 Resolved
Make propellers available for inspection.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 12 December 2017
Resolution: Props were SAT
Lifesaving › Lifefloat › Lifeline
Issued 20 April 2017 Resolved
Replace grab lines on lifering and lifefloats, and painters on lifefloats as discussed.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 2 May 2017
Resolution: Damaged grab lines and painters replaced.
Engineering › Bilge Water Management System › Valve
Issued 20 April 2017 Resolved
Provide each bilge suction line with a check valve.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 2 May 2017
Resolution: Bronze check valves installed on each bilge line.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 April 2017 Resolved
Repair cracked brackets on upper deck rail, stbd side as discussed.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 2 May 2017
Resolution: An additional bracket was installed as well as JB weld on cracks.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 22 March 2017 Resolved
Remove PVC penetration of lazarette bulkhead and replace with metallic piping or metallic penetration and valves on each side.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 2 May 2017
Resolution: Metallic nipple and bronze ball valves installed on each side of the bulkhead.
Lifesaving › Lifefloat › Serviceable
Issued 13 April 2016 Resolved
JE01 Repair life float IAW with manufactures recommendations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 25 April 2016
Resolution: Received email with photos showing life float had been properly repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2016 Resolved
JE02 Repair life ring IAW manufactures recommendation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 25 April 2016
Resolution: Received email with photos showing life ring properly repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 April 2016 Resolved
JE03 Provide first aid kit meeting requirements of 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 25 April 2016
Resolution: Received email with photos showing missing Ammonia Inhalants had be placed in first aid kit.
Lifesaving › Lifefloat › Serviceable
Issued 22 May 2014 Resolved
One of the five lifefloats needs to be repair with an approved [name withheld] repair kit. Vessel is restricted to 57 passenger and 60 total persons on a limited coastwise cold water route and 117 passengers and 120 total passengers on limited coastwise warm water and while within 3 NM from shore.
Action required: 705 - Other - as specified
Resolved 24 July 2014
Resolution: Owner repaired LF with [name withheld] repair kit.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 May 2014 Resolved
06 PFD where condemned owner must replace with 6 adult type 1 PFDs. Passenger count is already restricted to 120 total people because of lifefloat.
Action required: 705 - Other - as specified
Resolved 30 May 2014
Resolution: Photo received via email with 6 new PFDs
Engineering › Fuel Oil Service System › Piping
Issued 22 May 2014 Resolved
Vessel had flex hose fuel piping for generator penetrating watertight bulkheads. Owner must submit plan proposal to fix in accordance with regulations.
Action required: 705 - Other - as specified
Due 1 December 2014
Resolved 15 October 2014
Resolution: Owner sent photos of the bulkhead penetrations. Fittings will be closely inspected during next inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2014 Resolved
Deadend wiring and improper connections found throughout vessel. Showed to vessel owner. Repair as new.
Due 20 May 2014
Resolved 22 May 2014
Resolution: Deadend wires made safe.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 March 2014 Resolved
Repair/replace grounding wires for tanks/through hulls.
Due 20 May 2014
Resolved 22 May 2014
Resolution: Grounding wires replaced
Stability › Watertight Integrity › General
Issued 20 March 2014 Resolved
Ball valves for starboard engine intake and generator did not stop properly while exercising. Repair/replace as new.
Due 20 March 2014
Resolved 20 March 2014
Resolution: Ball valve handles were rewelded and valves closed properly.
Stability › Watertight Integrity › General
Issued 20 March 2014 Resolved
Seal bulkhead holes in collision bulkhead. Repair as new.
Due 20 May 2014
Resolved 22 May 2014
Resolution: Holes sealed
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2014 Resolved
In 2nd compartment lights were missing guard/glass protectors. Repair/replace as new.
Due 20 May 2014
Resolved 22 May 2014
Resolution: guards and glass replaced
Construction/Loadline › Penetrations › Gasket
Issued 15 May 2012 Resolved
Repair fire hydrant valve to stop rain water from leaking through, traveling through natural ventilation to engine room, and onto engine room wiring to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 23 May 2012
Resolution: O/O provided photograph showing new caulking surrounding fire hydrant''s penetration through bulkhead to seal off leaks into engine room.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 14 May 2009 Resolved
Replace to new condition the lanyards for four (4) of the floating waterlights on the lifesaving appliances. Correct deficiency to the satisfaction of the marine inspector prior to carrying passengers at night.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 May 2009
Resolution: Owner replaced all four (4) lanyards for the floating waterlights.
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 22 May 2008 Resolved
Perform housekeeping on all BA's and better organize all lines by 27May08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2008
Resolved 10 June 2008
Resolution: Attended vessel to verify that housekeeping and organization of the BA lifelines had been performed, all sat.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 15 June 2007 Resolved
Vessels Safety Radio Cert was expired.
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 20 June 2007
Lifesaving › Lifejacket/PFD (Type II) › Marking
Issued 15 June 2007 Resolved
Properly replace the retro on 05 L/Js
Due 22 June 2007
Resolved 20 June 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 June 2007 Resolved
Properly securethe vessels overboard sewage valve.
Due 15 June 2007
Resolved 22 June 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 15 June 2007 Resolved
Properly cap the unused valve in the lazarette.
Due 15 June 2007
Resolved 22 June 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 May 2006 Resolved
Provide 6 year service on B-1, B-II, and B-III extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2006
Resolved 16 May 2006
Resolution: O/O provided service report from A.W.T. [name withheld] indicating that required servicing had been completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 9 May 2006 Resolved
Prove proper operation of heat sensor in engine room and associated alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2006
Resolved 16 May 2006
Resolution: O/O faxed in service report attesting to repair of heat sensor and that it is now working properly.
Communications › Radio Communications › EPIRB
Issued 9 May 2006 Resolved
Replace expired HRU in EPIRB. Vessel restricted to carrying passengers NMT 3 miles until cleared.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. HRU in EPIRB has been replaced with a new unit.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 9 May 2006 Resolved
Enroll Kenneth Wescoat into consortium. [name withheld] not to serve as Master or deckhand until requirement is met.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. [name withheld] is in full compliance.
Navigation › Piloting/Steering › Marine Charts
Issued 9 May 2006 Resolved
Provide updated chart #12316
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. New chart on board.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 May 2006 Resolved
Repair broken waterlight bracket (port bridge life ring).
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. New bracket is in place.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 May 2006 Resolved
Replace wasted running light shields.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. Shields have been renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 May 2006 Resolved
Prove proper operation of starboard running light and anchor light.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. All nav lights working properly.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 May 2006 Resolved
Repair/Replace electrical box forward overhead/main deck.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. Area of concern has been sealed with silicon as a temporary measure. A new box is on order.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 9 May 2006 Resolved
Remove/Replace broken grab rail outside exit, port side.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. A new grab rail is in place.
Fire Fighting › Combustible Materials › Ceilings
Issued 9 May 2006 Resolved
Remove peeling paint from overhead in engine room.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 25 May 2006
Resolution: Attended vessel. Peeling paint has been removed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 April 2005 Resolved
Lengthen lines on life float lights to 18 feet.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 18 May 2005
Resolution: Attended vessel. Verified that lanyards on life float waterlights are now 18 feet in length.
Engineering › Fuel Oil Service System › Valve
Issued 11 April 2005 Resolved
Anchor emergency shutoff linkage to valve handle.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 18 May 2005
Resolution: Attended vessel. Verified that remote handles are fast to the valves and operate as required.
Fire Fighting › Ventilation Systems › Ducts
Issued 11 April 2005 Resolved
Provide means to secure engine room ventilation.
Action required: 705 - Other - as specified
Due 18 June 2005
Resolved 13 September 2005
Resolution: Attended vessel. O/O has installed means to secure ventilation duct using a metal slat that slides into a guideway. Installed on both port and starboard sides.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 April 2005 Resolved
Repair inoperative lighting fixture in cabin (32V light).
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 18 May 2005
Resolution: Attended vessel. Verified that light has been repaired and is operational.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 11 April 2005 Resolved
Repair starboard engine oil pressure and water temperature gages at the bridge operating station.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 18 May 2005
Resolution: Attended vessel. Started starboard engine and verified proper operation of all gauges.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 April 2005 Resolved
Provide proof of enrollment of Fred Hample into vessel consortium. Fred Hample may not serve as a Master or Crewman until this requirement has been cleared.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 18 May 2005
Resolution: Attended vessel. [name withheld] verified as being on the covered employee list for the vessel.
Construction/Loadline › Hull › Side Shell
Issued 19 January 2005 Resolved
Make repairs to indicated areas of the hull.
Due 19 February 2005
Resolved 15 February 2005
Resolution: Attended vessel and verified that areas marked for attention were properly repaired.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 19 January 2005 Resolved
Repair cracked welds on anchor bracket.
Due 19 February 2005
Resolved 15 February 2005
Resolution: Attended vessel. Cracks on both port and starboard weld seams of anchor bracket have been repaired satisfactory.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 January 2005 Resolved
Crop/Renew rotted areas of overhead in engine room. (port side)
Due 19 February 2005
Resolved 15 February 2005
Resolution: Attended vessel. Rotted overhead panel has been replaced.
Engineering › Sea-water System (primary cooling) › Valve
Issued 19 January 2005 Resolved
Replace 1 1/2" gate valve for MSD intake due to cracks in seat.
Due 19 February 2005
Resolved 15 February 2005
Resolution: Attended vessel. Faulty gate valve was replaced with new ball valve. Tested satisfacory.
Lifesaving
Issued 10 May 2004 Resolved
Replace lines on top life float.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Replaced all lines on top life float.
Lifesaving
Issued 10 May 2004 Resolved
Replace pendant lines on port life float.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Pendant lines replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 May 2004 Resolved
Vessel restricted to 145 passengers. Two life jackets missing.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Provided 2 additional life jackets.
Navigation
Issued 10 May 2004 Resolved
Replace chart #12316, #12324 and Coast Pilot and Light List.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Updated all above items.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 May 2004 Resolved
Replace eye wash in first aid kit.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Replaced eye wash in first aid kit.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 10 May 2004 Resolved
Replace broken wire on generator.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Installed new wire.
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 10 May 2004 Resolved
Install bowls on each fuel filter.
Due 30 May 2004
Resolved 27 May 2004
Resolution: Installed bowls on each fuel filter. Inspected sat.
Lifesaving
Issued 20 May 2003 Resolved
Secure water light lines to life float.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Secured water lights lines to life floats.
Lifesaving
Issued 20 May 2003 Resolved
Secure new oars to life floats.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Secured new oars to each life float.
Accommodation/Occupational Safety
Issued 20 May 2003 Resolved
Stencil upper deck with maximum passengers allowed.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Upper deck stenciled with max passenger allowed.
Lifesaving
Issued 20 May 2003 Resolved
Provide and mount additional ring buoy with line. Vessel has required amount. Recommended addistional ring buoy due to location of existing ring buoy.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Mounted an additional ring buoy with heaving line on stbd side, just outside door into cabin space.
Lifesaving
Issued 20 May 2003 Resolved
Stencil number of lifejackets on lockers.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Stenciled number of lifejackets on life jacket lockers.
Lifesaving
Issued 20 May 2003 Resolved
Separate child PFD's from adult PFD's and stencil with correct number for each.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Placed a partion in between adult and child life jackets under bench.
Operations/Management
Issued 20 May 2003 Resolved
Post waste management plan and life jacket donning placard on 2nd deck.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Posted placards on 2nd deck.
Lifesaving
Issued 20 May 2003 Resolved
Replace grab lines, patch two holes, and replace cotton line on bottom life floats.
Due 11 June 2003
Resolved 11 June 2003
Resolution: Completed all items required by marine inspector.
Documentation
Issued 26 April 2002 Resolved
Post satbility letter in pilothouse.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Posted stability letter in pilothouse.
Navigation
Issued 26 April 2002 Resolved
Update all vessel's charts for area.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Purchased all new charts.
Lifesaving
Issued 26 April 2002 Resolved
Replace water lights on lifefloats.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Purchased and installed new waterlights on lifefloats.
Lifesaving
Issued 26 April 2002 Resolved
Rpl;ace ring buoy.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Installed new ring buoy.
Lifesaving
Issued 26 April 2002 Resolved
Make repairs to 3 lifefloats.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Repaired 3 lifefloats.
Lifesaving
Issued 26 April 2002 Resolved
Replace sea painters on life floats.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Installed all new sea painters on life floats.
Electrical › Lighting (service)
Issued 26 April 2002 Resolved
Install cover on light in engine room.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Installed new cover on light in engine room.
Electrical
Issued 26 April 2002 Resolved
Remove dead end wires in steering compartment.
Due 17 May 2002
Resolved 9 May 2002
Resolution: Removed dead end wires.
Engineering
Issued 26 April 2002 Resolved
Install double hose clamps on generator wet exhaust in steering compartment
Due 17 May 2002
Resolved 9 May 2002
Resolution: Installed double hose clamps on generator exhaust in steering comparment.
Engineering
Issued 6 March 2001 Resolved
REPAIR LEAK ON SALT WATER DISCHARGE LINE.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Construction/Loadline
Issued 6 March 2001 Resolved
REPLACE BILGE/FIRE PUMP HOSE.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Construction/Loadline
Issued 6 March 2001 Resolved
REPLACE ZINCS.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Lifesaving
Issued 6 March 2001 Resolved
COMMENCING 11MAR01, VESSEL IS LIMITED TO 73 PASSENGERS WHEN OPERATING BEYOND 3 MILES ON LIMITED COASTWISE ROUTE DURING COLD WATER MONTHS (01NOV- 31MAY), IN ADDITION TO ANY OTHER RESTRICTIONS ON CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 4 July 2001
Resolved 21 May 2001
Engineering
Issued 6 March 2001 Resolved
DOUBLE CLAMP HOSES.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Accommodation/Occupational Safety
Issued 6 March 2001 Resolved
REPLACE MSD DISCHARGE VALVE.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Lifesaving
Issued 19 April 2000 Resolved
REDUCE NUMBER OF PERSONS CARRIED TO 143 DUE TO 143 ACCEPTABLE ADULT LIFE JACKETS ON BOARD.
Condition: Unknown
Due 19 May 2000
Resolved 2 May 2000
Documentation
Issued 19 April 2000 Resolved
VESSEL OPERATOR TO PROCURE A RADIO OPERATOR PERMIT, VESSEL OPERATION RESTRICTED TO 1000 FT FROM SHORE.
Condition: Unknown
Due 19 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 20 May 1999 Resolved
CORRECT MALFUNCTION OF BILGE HIGH LEVEL AUDIBLE ALARM.
Condition: Unknown
Due 20 June 1999
Resolved 23 July 1999
Fire Fighting
Issued 20 May 1999 Resolved
COMPLETE INSTALLATION OF FIXED FIRE DETECTION AND FIRE EXTINGUISHING SYSTEM, AND PRESENT FOR TESTING AND INSPECTION IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 20 June 1999
Resolved 23 July 1999
Accommodation/Occupational Safety
Issued 30 April 1997 Resolved
REWELD CRACKS IN HANDRAIL ON LADDER.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Lifesaving
Issued 30 April 1997 Resolved
REPAIR/REPLACE ALL 06 LIFEFLOATS, VSL LIMITED TO A RIVERS ROUTE.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 30 April 1997 Resolved
PROVIDE APPROVED FIRST AID KIT, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 30 April 1997 Resolved
PROVIDE 10 ADULT PFD'S, VSL LIMITED TO 140 TOTAL PERSONS.
Condition: Unknown
Due 7 October 1997
Resolved 7 October 1997
Lifesaving
Issued 12 April 1995 Resolved
PRIOR TO CARRYING MORE THAN 127 PASSENGERS, MAKE PROPER REPAIRS TO THE 10 PERSON JIM BUOY LIFEFLOAT.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995 Resolved
PRIOR TO CARRYING MORE THAN 144 PASSENGERS, PROVIDE 3 ADDITIONAL USCG APPROVED TYPE I ADULT-SIZE LIFE PRESERVERS.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Electrical
Issued 16 May 1994 Resolved
PROVIDE PROPER WIRING CONNECTIONS ON THE 32 VOLT LIGHT IN THE FUEL COMPARTMENT.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Lifesaving
Issued 16 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW THE HANG LINES ON THE LOWER PORT SIDE LIFEFLOAT.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Fire Fighting
Issued 16 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROPERLY SERVICE ALL PORTABLE FIRE EXTINGUISHERS EXCEPT THE B-I ON THE BRIDGE AND THE B-II IN THE ENGINEROOM.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Construction/Loadline
Issued 16 May 1994 Resolved
DEMONSTRATE PROPER OPERATION OF THE BILGE PUMP.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Engineering
Issued 16 May 1994 Resolved
MAKE PERMANENT REPAIRS TO THE FUEL TANK VENT (AFT).
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Construction/Loadline
Issued 16 May 1994 Resolved
PROVIDE A KEEPER CHAIN FOR THE FORWARD DECK HATCH.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Lifesaving
Issued 16 May 1994 Resolved
PRIOR TO CARRYING MORE THAN 132 PASSENGERS, PROVIDE 15 ADDITIONAL ADULT AND1 ADDITIONAL CHILD-SIZE TYPE I USCG APPROVED LIFE PRESERVERS.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Lifesaving
Issued 16 May 1994 Resolved
PRIOR TO CARRYING PASSENGERS, RENEW WATERLIGHT LINES ON ALL LIFEFLOATS AND THE RING BUOY.
Condition: Unknown
Due 16 May 1994
Resolved 16 May 1994
Fire Fighting
Issued 5 May 1993 Resolved
PROVIDE PROFESSIONAL SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Documentation
Issued 5 May 1993 Resolved
RENEW THE FCC OPERATORS PERMIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Accommodation/Occupational Safety
Issued 5 May 1993 Resolved
PROVIDE A POSTED COPY OF THE WASTE MANAGEMENT PLAN ON BOTH PASSENGER DECKS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Navigation
Issued 5 May 1993 Resolved
PROVIDE A CURRENT COPY, OR APPLICABLE EXTRACT FROM, THE U.S. COAST PILOT AND LIGHT LIST. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1993
Resolved 7 June 1993
Navigation
Issued 6 May 1992 Resolved
OBTAIN NEW CHARTS FOR THE ROUTE SPECIFIED ON THE COI.
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Lifesaving
Issued 6 May 1992 Resolved
OBTAIN 9 ADULT PFDs FOR A TOTAL OF 150 ADULT PFDs. THE TOTAL NUMBER OF PERSONS IS RESTRICTED TO 141 UNTIL THE REQUIRED NUMBER OF PFDs ARE ON BOARD
Condition: Unknown
Due 28 September 1992
Resolved 28 September 1992
Navigation
Issued 9 May 1991 Resolved
PROVIDE ANCHOR DAY SHAPE (BLACK BALL)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Lifesaving
Issued 9 May 1991 Resolved
MAKE REPAIRS TO 15 MAN LIFEFLOAT (REMOVED FROM VESSEL). UNTIL SUCH TIME ASREPAIRS ARE COMPLETED, THE VESSEL IS RESTRICTED TO CARRYING NO MORE THAN 120 PERSONS.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Lifesaving
Issued 9 May 1991 Resolved
REPLACE 18 ADULTS LIFEJACKETS WHERE WORN. UNTIL SUCH TIME AS THEY ARE REPLACED, THE VESSEL IS LIMITED TO CARRYING NOT MORE THAN 132 ADULTS.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Navigation
Issued 9 May 1991 Resolved
PROVIDE CURRENT NAVIGATION CHARTS FOR ARE OF OPERATION, SANDY HOOK, NJ TO CAPE MAY, NJ.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 30 April 1990 Resolved
PROVIDE OPERATIONAL TEST OF BELT DRIVEN BILGE PUMP PRESENTLY INOPERABLE, VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS CORRECTED
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Lifesaving
Issued 30 April 1990 Resolved
REPAIR OR REPLACE (1)FLOATING WATER FOR LIFE FLOAT PRESENTLY INOPERABLE, VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS CORRECT ED.
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Construction/Loadline
Issued 30 April 1990 Resolved
MAKE PERMANENT REPAIRS TO PORT MAIN DIESEL ENGINE SEA WATER STRAINER PRE- SENTLY TAKING ON WATER,VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Construction/Loadline
Issued 30 April 1990 Resolved
MAKE PERMANENT REPAIRS TO PORT STREN CORNER WHERE CRACKED AT THE MAIN DECK ITEM TO BE CORRECTED AT NEXT REGULARILY SCHEDULED D/D EXAM.
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Lifesaving
Issued 30 April 1990 Resolved
MAKE REPAIRS TO (3) ADULT PFD'S WHERE STITCHING AROUND SHOULDER AREA IS MISSING,VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS CORRECTED
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Lifesaving
Issued 30 April 1990 Resolved
MARK OR STENCIL ALL ADULT PFD STOWAGE COMPARTMENTS WITH THE SIZE AND AMOUNTOF PFD'S STOWED INSIDE.
Condition: Unknown
Due 30 April 1990
Resolved 30 April 1990
Engineering
Issued 5 May 1988 Resolved
REFIT STRAINER BOLT WHERE MISSING FROM THE PORT MAIN ENGINE RAW WATER SUCTION STRAINER COVER PRIOR TO CARRYING PASSENGERS FOR HIRE. (ORIGINAL COMPLIANCE DATE IS 05JUN88)
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988
Lifesaving
Issued 5 May 1988 Resolved
PROVIDE TWO ADULT TYPE I LIFE PRESERVERS. (ORIGINAL COMPLIANCE DATE IS 05JUN88)
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988
Construction/Loadline
Issued 5 May 1988 Resolved
MAKE REPAIRS IN WAY OF LIFTED STARBOARD BOW BULWORK WHERE IT HAS LIFTED FROM THE HULL STRUCTURE PRIOR TO CARRYING PASSENGERS FOR HIRE. (ORIGINAL COMPLIANCE DATE IS 05JUN88)
Condition: Unknown
Due 5 May 1988
Resolved 5 May 1988
Engineering
Issued 22 May 1987 Resolved
PRIOR TO CARRYING PASSENGERS, REFIT THE BILGE SYSTEM WITH NON-COLLAPSIBLE HOSE AND PROPER STRAINERS.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Lifesaving
Issued 22 May 1987 Resolved
MARK THE LIFE FLOATS AND OARS WITH THE VESSEL'S NAME.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Lifesaving
Issued 22 May 1987 Resolved
RENEW THE LIFE FLOAT'S WEAK LINKS TWO (2).
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Construction/Loadline
Issued 22 May 1987 Resolved
REWELD AFT RAIL WHERE CRACKED.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987

Casualty record · 1

28 September 2009Routine · role: Involved in a Marine Casualty · activity 3605555
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record