CRUISN 1

CRUISN 1 is a 1979 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in May 2026, along with 33 deficiencies and 1 casualty investigation in 2009.

Records from 2009 to 2026. Most recent: inspection, 19 May 2026.

Built
1979
Last inspected
19 May 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE4444
Flag
UNITED STATES
Maury page id
psix-54403

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.6 ft × 8.3 ft
Registered tonnagegross 79 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE, INC. · PANAMA CITY, FL, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portATLANTIC CITY, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Net Ton
79 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

19 May 2026 Annual Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8357142
11 February 2026 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8308840
1 December 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8276279
3 April 2025 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8103902
10 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7931168
29 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7831325
10 October 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7806243
18 May 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7692389
22 June 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7484400
17 May 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7454452
5 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7345876
24 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7206314
30 March 2020 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6933327
14 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6855359
7 May 2019 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6678478
30 April 2018 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402262
5 December 2017 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6317906
22 March 2017 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6109815
13 April 2016 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5872386
5 January 2016 Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5792108

Deficiency record · 33

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 May 2026 Resolved
Each item of survival craft equipment must be of good quality. Vessel's life floats have numerous cracks that need to be repaired. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2026
Resolved 11 June 2026
Resolution: All life floats cracks have been repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 19 May 2026 Resolved
The maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Signage for passengers allowed on the upper deck is incorrect. 46 CFR 185.602
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2026
Resolved 4 June 2026
Resolution: Vessel added proper signage for upper deck.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessels has gone past its required dry dock exam date as stated on COI of 30 NOV 25. Complete credit drydock examination prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2026
Resolution: Vessel completed satisfactory Drydock
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 June 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life floats to be serviced or repaired with authorized materials; Painter line/ light to be affixed around the body of each life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2024
Resolution: Verified repair of life float, cleared deficiency accordingly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 May 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had life jacket donning instructions for over the head life jackets, but none posted for the clip front type life jackets on board. Post life jacket donning procedures for new life jackets in vicinity of where they are stowed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 2 June 2023
Resolution: Vessel provided photo of new lifejacket donning placard posted - see documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Two dead end, exposed, wires were hanging out of the top of the operation station. Remove wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 2 June 2023
Resolution: Vessel provided photo evidence of hazardous electrical wiring removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2022 Resolved
Vessel's crew unable to satisfactorily complete man overboard drills to the satisfaction of the USCG. Vessel to implement an extra roving watch until drills can be witnessed on 3JUNE2022. 46 CFR 185.520(a)
Action required: 705 - Other - as specified
Due 17 May 2022
Resolved 3 June 2022
Resolution: Re-attended vsl, crew demonstrated proficient knowledge and displayed safety.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2022 Resolved
Emergency fuel shutoffs did not completely close valves when operated. Adjust remote operation for full closure. OLD T 46 CFR 182.20-40(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 3 June 2022
Resolution: VSL added reachrod to fuel shut-offs satisfacotriy showing full closure.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 May 2022 Resolved
Alcohol swabs onboard for drug and alcohol program were expired. Replace with new and ready for use swabs. 46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 3 June 2022
Resolution: Replaced expired alcohol swabs
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 May 2022 Resolved
Vessel had one inoperable portable light. Acquire working portable light 46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 3 June 2022
Resolution: Aquired working portable light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Generator exhaust pipe has leak located at midpoint section located in steering compartment. Repair/replace section of pipe with leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 18 June 2021
Resolution: Leak was patched.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 May 2021 Resolved
Ten flares (6 red hand flares & 4 orange smoke/red flare) onboard. Add two additional flares to meet requirement for 6 hand red flares (night) and six hand orange smoke (day) signals.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 18 June 2021
Resolution: Flares procured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 May 2021 Resolved
Starboard side railing mount located midships had crack in weld where mounted to top of bulwark. Inspect and repair weld.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2021
Resolved 29 June 2021
Resolution: Railing welded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021 Resolved
Extinguisher on main deck outside crew space does not have proper bracket. Install bracket as approved by extinguisher manufacturer.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2021
Resolution: Extinguisher mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2021 Resolved
Space heater installed on upper deck using exposed twist on wire nuts and not in accordance with spacing required per label on heater. Remove heater and provide installation plans for USCG electrical plan review if re installation is desired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2021
Resolution: Heater removed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 April 2020 Resolved
Missing 01 required distress signals/flares. Replace with either a Hand Red Flare (Approval series 160.021), Hand Orange Smoke ("160.037), Floating Orange Smoke ("160.022), or a Rocket Parachute Flare ("160.036). Vessel is required to carry 12. 46 CFR 180.68
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2020
Resolved 8 April 2020
Resolution: Jeff showed a receipt from him buying another pack of approved flares
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 April 2020 Resolved
Vessel has 02 VHF radio installations sharing the same circuit breaker. A separate circuit, with over-current protection at the main distribution panel, must be provided for each radio installation. 46 CFR 183.392
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2020
Resolved 8 April 2020
Resolution: Jeff sent a video in showing each VHF radio being powered by seperate circuits
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2019 Resolved
Ensure Coast Guard oversight of repairs to wet exhaust piping.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 January 2020
Resolution: recieved photos showing fit up of stbd side, saw port side in person
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2019 Resolved
Repair/replace intake valve in lazarette, stbd side
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2019
Resolution: Valve has been replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2019 Resolved
Replace expired alcohol testing strips.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 11 May 2019
Resolution: Purchased new testing strips from local vendor.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2018 Resolved
Renew FCC Radio Safety Certificate. 47CFR80.1005
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 15 May 2018
Resolution: The vessel had a technician come out, service their radios and issue a new certificate.
Navigation › Piloting/Steering › Marine Charts
Issued 7 May 2018 Resolved
Provide proof of updated charts
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 15 May 2018
Resolution: Owner updated charts and sent photos.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2018 Resolved
Add MMSI data to DSC Radio. 47CFR80
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 7 May 2018
Resolution: MMSI data was added to the radio.
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2018 Resolved
Remove extension cord that goes from engine room to accommodation space. Replace with properly sized boat cable and outlet that is wired into a breaker.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2018
Resolved 15 May 2018
Resolution: The extension cord was removed and a perminent cable and outlet was installed.
Construction/Loadline › Hull › Hull Plating
Issued 5 December 2017 Resolved
Grind back to good glass and repair section on port side forward of shaft and section of aft keel.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 12 December 2017
Resolution: Item was repaired
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 5 December 2017 Resolved
Make propellers available for inspection.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 12 December 2017
Resolution: Props were SAT
Lifesaving › Lifefloat › Lifeline
Issued 20 April 2017 Resolved
Replace grab lines on lifering and lifefloats, and painters on lifefloats as discussed.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 2 May 2017
Resolution: Damaged grab lines and painters replaced.
Engineering › Bilge Water Management System › Valve
Issued 20 April 2017 Resolved
Provide each bilge suction line with a check valve.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 2 May 2017
Resolution: Bronze check valves installed on each bilge line.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 April 2017 Resolved
Repair cracked brackets on upper deck rail, stbd side as discussed.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 2 May 2017
Resolution: An additional bracket was installed as well as JB weld on cracks.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 22 March 2017 Resolved
Remove PVC penetration of lazarette bulkhead and replace with metallic piping or metallic penetration and valves on each side.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 2 May 2017
Resolution: Metallic nipple and bronze ball valves installed on each side of the bulkhead.
Lifesaving › Lifefloat › Serviceable
Issued 13 April 2016 Resolved
JE01 Repair life float IAW with manufactures recommendations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 25 April 2016
Resolution: Received email with photos showing life float had been properly repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2016 Resolved
JE02 Repair life ring IAW manufactures recommendation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 25 April 2016
Resolution: Received email with photos showing life ring properly repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 April 2016 Resolved
JE03 Provide first aid kit meeting requirements of 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 25 April 2016
Resolution: Received email with photos showing missing Ammonia Inhalants had be placed in first aid kit.

Casualty record · 1

28 September 2009Routine · role: Involved in a Marine Casualty · activity 3605555
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.