MAURY USCG vessel records Sign in
← All vessels

MS ALISSA

MS ALISSA is a 1983 offshore supply vessel. The Coast Guard has recorded 45 inspections since 1983, most recently in March 2019, along with 22 deficiencies and 1 casualty investigation in 2003.

Records from 1983 to 2019. Most recent: inspection, 7 March 2019.

Built
1983
Last inspected
7 March 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8737
Flag
UNITED STATES
338898000, 366927010, 367092320 (licence lapsed)
Maury page id
psix-54405

Inspections, by type

…with no type recorded10
Years with a record 28 calendar years (1983–2019)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Net Ton
94 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC8737MMSI 367092320 · cancelled · compulsorily equipped · granted 12 February 2016, cancelled 6 September 2019
WDB6584MMSI 366927010 · cancelled · compulsorily equipped · granted 25 February 2004, cancelled 3 June 2011 · licensed under a name not among this hull’s recorded names (not shown)
WRB5735MMSI 338898000 · cancelled · compulsorily equipped · granted 30 November 1998, cancelled 6 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

7 March 2019 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6638350
9 February 2018 Internal Structural Exam · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6352815
13 March 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6104047
21 January 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5801410
11 January 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5795380
19 January 2011 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3929217
7 May 2009 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3469653
28 May 2008 Internal Structural Exam · Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3219334
24 March 2008 Examination of Repairs · Ballast Water Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3170390
28 February 2007 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2879436
31 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2864559
8 February 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2578931
8 December 2005 Examination of Repairs · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2547787
6 December 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2547135
25 November 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2546285
23 February 2005 Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2298116
30 January 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1997578
16 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971715
8 December 2003 Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1960350
10 October 2003 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1940914
10 October 2003 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1950712
6 February 2003 Damage Survey · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1740864
2 February 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1767686
22 January 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1479289
4 January 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1489657
10 August 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1074352
6 January 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450383
11 December 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395074
18 November 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430478
15 November 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463278
30 January 1996 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427171
12 January 1996 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377588
23 November 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356926
2 December 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394032
19 November 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376893
31 October 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243792
20 November 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901779
24 January 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236577
22 November 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897107
29 December 1987 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1011196
20 November 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022491
16 January 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292633
30 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978103
8 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279451
3 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274742

Deficiency record · 22

Electrical › Electrical Distribution System (service) › Cable
Issued 22 January 2016 Resolved
Multiple cable runs were found to be missing metal supports
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 January 2016
Resolution: Metal supports installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 January 2011 Resolved
Provide dual nav. lights for vessel. Due to keel laid date vessel is required to have dual Nav. lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2011
Construction/Loadline › Hull › Bottom Plating
Issued 20 March 2008 Resolved
Temporary repair was authorized to the keel Cooler due to Drydock interval in December 2008, in which repairs will be conducted to origanal scantlings. Vessel will have 30 days after their drydock period to complete repairs to the satisfaction of the local marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 28 May 2008
Resolution: Permanent repairs complete.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 March 2008 Resolved
Temporary repair was authorized to the Port side Engine room exhaust (next to engine room ladder) due to Dry-dock interval in December 2008, in which repairs will be conducted to original scantlings. Vessel will have 30 days after their dry-dock period to complete repairs to the satisfaction of the local marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 28 May 2008
Resolution: Permanent repairs completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 March 2008 Resolved
fractures to exterior exhaust vents (Port and STBD)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 21 March 2008
Resolution: Gouged out and welded fractures to exterior exhaust vents (Port and STBD)
Construction/Loadline › Structures › Ventilators
Issued 31 January 2007 Resolved
Provide tank and void vent closures as required by 46 CFR 56.50-85.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 28 February 2007
Resolution: Provided.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 January 2007 Resolved
Provide fire safety plan for approval.
Action required: 705 - Other - as specified
Due 15 March 2007
Resolved 28 February 2007
Resolution: Provided.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2005 Resolved
Conduct permanent repairs to stbd side shell plate and framing in E/R at next drydock.
Action required: 705 - Other - as specified
Due 7 December 2005
Resolved 9 February 2006
Resolution: Side shell repaired during dry dock.
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 23 February 2005 Resolved
Provide shaft tachs or equivilent in pilothouse as required by 46 CFR 113.37 (old "I").
Action required: 705 - Other - as specified
Due 25 March 2005
Resolved 13 February 2006
Documentation › Certificates/Documents
Issued 8 December 2003 Resolved
Provide new documentation showing name change and owner change. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 18 December 2003
Communications › Internal Communications System › Sound-powered Telephone
Issued 8 December 2003 Resolved
Repair ringer for pilothouse sound power phone.
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 18 December 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 8 December 2003 Resolved
Provide and install cover for galley hood light.
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 18 December 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 8 December 2003 Resolved
Remove extension cords used as permanent wiring.
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 18 December 2003
Engineering › Fuel Oil Service System
Issued 8 December 2003 Resolved
Repair fuel oil reach rod bracket. LEGACY COMPONENT DESC: Reach Rod
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 18 December 2003
Electrical › Electrical Distribution System (service)
Issued 8 December 2003 Resolved
Provide and install breaker blanks on main switchboard in open spaces. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 18 December 2003
Navigation › Piloting/Steering › Compass Deviation Table
Issued 20 February 2003 Resolved
PROVIDE UPDATED COMPASS DEVIATION CARD.
Action required: 705 - Other - as specified
Due 20 March 2003
Resolved 21 February 2003
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 February 2003 Resolved
REPAIR RUDDER ANGLE INDICATOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2003
Resolved 21 February 2003
Fire Fighting › Fire Main › Material
Issued 20 February 2003 Resolved
RENEW RUPTURED FIREMAIN PIPING IN PASSAGEWAY UNDER LADDER.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2003
Resolved 21 February 2003
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 February 2003 Resolved
PROVIDE EMERGENCY LIGHT FOR ESCAPE HATCH IN ENGINEROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2003
Resolved 21 February 2003
Electrical › Electrical Distribution System (service) › Switchboard
Issued 20 February 2003 Resolved
PROVIDE SCREWS FOR MAIN SWITCHBOARD COVER PANEL.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2003
Resolved 21 February 2003
Electrical › Electric Generation Source (service)
Issued 22 January 2002 Resolved
Port generator battery cable is corroded. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2002
Resolved 22 January 2002
Resolution: Renewed corroded battery cable.
Engineering › Fuel Oil Storage/Transfer System
Issued 22 January 2002 Resolved
Missing coupling guard for fuel transfer pump, and port generator vibration damper. LEGACY COMPONENT DESC: coupling guard
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2002
Resolved 22 January 2002
Resolution: Installed guards

Casualty record · 1

2 February 2003Routine · role: Involved in a Marine Casualty · activity 1767686
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

M/V PHILOCLES (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.