MAURY USCG vessel records
← All vessels

EAGLE

EAGLE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2017, most recently in July 2021, along with 13 deficiencies, 1 operational control and 3 casualty investigations between 2001 and 2017.

Records from 2001 to 2021. Most recent: inspection, 22 July 2021.

Built
1981
Last inspected
22 July 2021
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 July 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD5472
Flag
UNITED STATES
Maury page id
psix-54406

Documentation record

Registered dimensions (L × B × D)113.8 ft × 46.2 ft × 9.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderATLANTIC MARINE INC · FORT GEORGE ISLAND, FL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

22 July 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7264045
13 November 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7094785
20 February 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6912489
21 November 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6859736
18 December 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6599820
2 November 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6299335
13 October 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6286985
13 October 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6289388
11 October 2017 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6285777
18 January 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6072925

Deficiency record · 13

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 November 2019 Resolved
Numerous frames identified in rudder room #1 with chalk. Crop and renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2020
Resolution: Attended the vessel to inspect repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 November 2019 Resolved
Top rail on ladder to #1 wrap around is wasted. Replace or renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2020
Resolution: Attended the vessel to inspect repairs.
Construction/Loadline › Structures › Scuttle
Issued 2 November 2017 Resolved
REPAIR CRACK IN KNIFE'S EDGE TO #2 END SHAFT ALLEY. 46 CFR 179.360(a).
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: REPAIRED CRACK IN KNIFE'S EDGE TO #2 END SHAFT ALLEY.
Construction/Loadline › Structures › Trunk
Issued 2 November 2017 Resolved
CROP AND RENEW TO GOOD STEEL VERTICAL BEAM IN #1 END SHAFT ALLEY. 46 CFR 176.610(b).
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: CROPPED AND RENEWED TO GOOD STEEL THE VERTICAL BEAM IN #1 END SHAFT ALLEY.
Engineering › Bilge Water Management System › Piping
Issued 2 November 2017 Resolved
REPLACE PIPE FITTING FOR BILGE SUCTION IN #1 WRAP AROUND DECK SIDE. 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: REPLACED PIPE FITTING FOR BILGE SUCTION IN #1 WRAP AROUND DECK SIDE.
Construction/Loadline › Hull › Side Shell
Issued 2 November 2017 Resolved
CROP AND RENEW 09 DECK OVERHANGS. 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: CROPPED AND RENEWED 09 DECK OVERHANGS.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 October 2017 Resolved
46 CFR 183.01-10/46 CFR 183.310: Install guard on main engine belt.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 18 October 2017
Resolution: Guard installed
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 11 October 2017 Resolved
46 CFR 182.220(a): Gen #1 excessivley leaking oil, repair valve and replace gasket/seal.
Action required: 705 - Other - as specified
Due 16 October 2017
Resolved 18 October 2017
Resolution: Seals changed out
Engineering › Bilge Water Management System › Manifold
Issued 19 January 2017 Resolved
#2 shaft alley of bilge manifold in-op/cracked.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2017
Resolved 20 January 2017
Resolution: #2 shaft alley repaired and operable.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 19 January 2017 Resolved
Main fire pump needs repairs to seal leak.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2017
Resolved 20 January 2017
Resolution: Main fump pump repaired.
Electrical › Electric Generation Source (emergency) › Generator
Issued 19 January 2017 Resolved
Make repairs to Gen #1 fuel return leak.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2017
Resolved 20 January 2017
Resolution: Repairs made to secure Gen #1 fuel return leak.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 19 January 2017 Resolved
Provide chain or safety line for both steering compartment scuttles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 20 January 2017
Resolution: Chain provided to secure both steering compartment scuttles.
Electrical › Lighting (service) › Outlet Box
Issued 19 January 2017 Resolved
Install electric outlet cover in fiddley space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 20 January 2017
Resolution: Cover provided for electrical outlet in fiddley space.

Casualty record · 3

30 November 2001Routine · role: Involved in a Marine Casualty · activity 1484536
12 March 2011Routine · role: Involved in a Marine Casualty · activity 3964676
13 October 2017Routine · role: Involved in a Marine Casualty · activity 6289388
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.