MAURY USCG vessel records Sign in
← All vessels

EAGLE

EAGLE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1984, most recently in July 2021, along with 116 deficiencies, 1 operational control and 3 casualty investigations between 2001 and 2017.

Records from 1984 to 2021. Most recent: inspection, 22 July 2021.

Built
1981
Last inspected
22 July 2021
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5472
Flag
UNITED STATES
367158870
Maury page id
psix-54406

Inspections, by type

…with no type recorded13
Years with a record 34 calendar years (1984–2021)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)113.8 ft × 46.2 ft × 9.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderATLANTIC MARINE INC · FORT GEORGE ISLAND, FL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4279MMSI 367158870 · active · compulsorily equipped · granted 7 March 2017, expires 7 March 2027
WDD5472MMSI 367158870 · terminated · compulsorily equipped · granted 5 January 2007, cancelled 20 January 2017
WRA5151MMSI not assigned · expired · compulsorily equipped · granted 19 August 1996, cancelled 23 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

22 July 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7264045
13 November 2020 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7094785
20 February 2020 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6912489
21 November 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6859736
18 December 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6599820
2 November 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6299335
13 October 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6286985
13 October 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6289388
11 October 2017 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6285777
18 January 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6072925
10 November 2015 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5760836
27 August 2015 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5227492
9 February 2012 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4241131
26 July 2011 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4094546
3 February 2011 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3938293
26 January 2010 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3670161
12 February 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3416527
9 November 2007 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3095894
18 July 2007 Hull Examination
Physical examination · National Strike Force, Gulf Strike Team · Activity 2999109
17 January 2007 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2857086
5 January 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2561086
8 September 2005 Hull Examination · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486880
24 April 2005 Examination of Repairs · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2341567
7 December 2004 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2254775
8 April 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040166
14 October 2003 Hull Examination · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1928181
14 November 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1704330
12 December 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 773197
30 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1484536
28 November 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 772663
28 November 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1382447
4 October 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1414013
3 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1068154
2 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 43750
24 June 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 132200
24 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 179066
9 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 68399
3 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11523
31 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 159282
25 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 43180
29 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 812621
8 December 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 812555
17 November 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372827
28 October 1999 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1445537
2 December 1998 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1400885
2 December 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 176849
19 November 1997 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1109871
30 September 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 781715
21 November 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180189
12 January 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193017
13 December 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190358
27 November 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880227
6 October 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181386
9 August 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 881022
12 May 1995 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1216588
19 December 1994 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847941
10 January 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1414234
8 October 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 846113
11 January 1993 Drydock Extension · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1133470
20 October 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 934074
29 January 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1262211
9 August 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1001542
25 April 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 915814
24 January 1991 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1215121
1 February 1990 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 925614
21 July 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 896102
7 February 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1339976
21 April 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1039199
28 March 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1341476
12 February 1988 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1012082
10 June 1987 Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1335691
12 January 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1006169
13 January 1986 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299695
16 December 1985 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301139
26 October 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 993504

Deficiency record · 116

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 November 2019 Resolved
Numerous frames identified in rudder room #1 with chalk. Crop and renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2020
Resolution: Attended the vessel to inspect repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 21 November 2019 Resolved
Top rail on ladder to #1 wrap around is wasted. Replace or renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2020
Resolution: Attended the vessel to inspect repairs.
Construction/Loadline › Structures › Scuttle
Issued 2 November 2017 Resolved
REPAIR CRACK IN KNIFE'S EDGE TO #2 END SHAFT ALLEY. 46 CFR 179.360(a).
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: REPAIRED CRACK IN KNIFE'S EDGE TO #2 END SHAFT ALLEY.
Construction/Loadline › Structures › Trunk
Issued 2 November 2017 Resolved
CROP AND RENEW TO GOOD STEEL VERTICAL BEAM IN #1 END SHAFT ALLEY. 46 CFR 176.610(b).
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: CROPPED AND RENEWED TO GOOD STEEL THE VERTICAL BEAM IN #1 END SHAFT ALLEY.
Engineering › Bilge Water Management System › Piping
Issued 2 November 2017 Resolved
REPLACE PIPE FITTING FOR BILGE SUCTION IN #1 WRAP AROUND DECK SIDE. 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: REPLACED PIPE FITTING FOR BILGE SUCTION IN #1 WRAP AROUND DECK SIDE.
Construction/Loadline › Hull › Side Shell
Issued 2 November 2017 Resolved
CROP AND RENEW 09 DECK OVERHANGS. 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 29 December 2017
Resolution: CROPPED AND RENEWED 09 DECK OVERHANGS.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 October 2017 Resolved
46 CFR 183.01-10/46 CFR 183.310: Install guard on main engine belt.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 18 October 2017
Resolution: Guard installed
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 11 October 2017 Resolved
46 CFR 182.220(a): Gen #1 excessivley leaking oil, repair valve and replace gasket/seal.
Action required: 705 - Other - as specified
Due 16 October 2017
Resolved 18 October 2017
Resolution: Seals changed out
Engineering › Bilge Water Management System › Manifold
Issued 19 January 2017 Resolved
#2 shaft alley of bilge manifold in-op/cracked.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2017
Resolved 20 January 2017
Resolution: #2 shaft alley repaired and operable.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 19 January 2017 Resolved
Main fire pump needs repairs to seal leak.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2017
Resolved 20 January 2017
Resolution: Main fump pump repaired.
Electrical › Electric Generation Source (emergency) › Generator
Issued 19 January 2017 Resolved
Make repairs to Gen #1 fuel return leak.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2017
Resolved 20 January 2017
Resolution: Repairs made to secure Gen #1 fuel return leak.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 19 January 2017 Resolved
Provide chain or safety line for both steering compartment scuttles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 January 2017
Resolved 20 January 2017
Resolution: Chain provided to secure both steering compartment scuttles.
Electrical › Lighting (service) › Outlet Box
Issued 19 January 2017 Resolved
Install electric outlet cover in fiddley space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 20 January 2017
Resolution: Cover provided for electrical outlet in fiddley space.
Engineering › Bilge Water Management System › Piping
Issued 27 August 2015 Resolved
Operator to renew bilge piping in nbr2 shaft alley IWO deck side bulkhead shared with ballast tank due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Resolution: Operator renewed section of bilge piping.
Engineering › Bilge Water Management System › Piping
Issued 27 August 2015 Resolved
Operator to remove obsolete bilge discharge piping from through hull penetrations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Resolution: Operator removed section of piping and conducted permanent weld repair to hull penetration.
Construction/Loadline › Penetrations › Gasket
Issued 27 August 2015 Resolved
Operator to renew all scuttle gaskets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Resolution: Operator renewed all scuttle gaskets as required.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 August 2015 Resolved
Number 1 void; repair wastage at top of bulkhead shared w/shaft alley near midships ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 22 October 2015
Resolution: Operator preformed permanent repair to bulkhead. MI observed satisfactory air test of weld.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 August 2015 Resolved
Number 1 Shaft alley; secure cables IWO midships bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 22 October 2015
Resolution: Operator secured all cable runs.
Construction/Loadline › Hull › Transverse Frame
Issued 27 August 2015 Resolved
Number 1 wrap-around, deck side; gouge and re-weld cracked frame IWO 2nd transverse fwd from ladder IWO centerline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 9 October 2015
Resolution: Operator had permanent weld repair conducted.
Construction/Loadline › Structures › Air Pipe
Issued 27 July 2011 Resolved
Crop & renew wasted vent pipe in way of #2 cross over deck side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Engineering › Bilge Water Management System › Piping
Issued 27 July 2011 Resolved
Crop & Renew wasted bilge pipe elbow in the #1 ballast tank in way of ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 27 July 2011 Resolved
Install metallic cable supports for electric cables in #1 & #2 steering compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 July 2011 Resolved
Repack & make watertight the receptacle box in the #1 steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 July 2011 Resolved
Secure hatches for #2 & #1 steering compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Stability › Freeing Ports › General
Issued 27 July 2011 Resolved
Remove all debris & install strainer for the #2 01 deck scupper.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Electrical › Electrical Distribution System (service) › Cable
Issued 27 July 2011 Resolved
Remove wire nuts and properly splice the cable with pressure type connectors in the #2 A/C compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Deck/Cargo › Ballast › Tank
Issued 26 July 2011 Resolved
Crop & renew base vertical angle iron deck support in #2 wheelhouse cross-over tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2011
Construction/Loadline › Structures › Manhole
Issued 12 February 2009 Resolved
Make permanent repairs to holed and wasted steel IWO access cover to the #2 crossover trunk.
Action required: 705 - Other - as specified
Due 28 February 2009
Resolved 9 December 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 14 November 2007 Resolved
Make proper repairs to #1 Main engine fuel distribution and injection systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2007
Resolved 14 November 2007
Resolution: fax
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 July 2007 Resolved
Descale #2 wrap around IWO alley and present for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 11 September 2007
Resolution: onboard
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 July 2007 Resolved
Gauge bulkhead between eng room and #1 cross flooding tank on wheel house side and provide report.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 11 September 2007
Resolution: onboard
Engineering › Bilge Water Management System › Strainer
Issued 18 July 2007 Resolved
Descale/clean paint off bilge pump (strainer) in #1 wrap around.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 11 September 2007
Resolution: onboard
Engineering › Bilge Water Management System › Piping
Issued 18 July 2007 Resolved
Make proper repair to bilge suction pipe in #2 wrap around on deck side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 7 September 2007
Resolution: onboard
Engineering › Bilge Water Management System › Pump
Issued 18 July 2007 Resolved
Prove proper operation of bilge dewatering system and fire monitor.
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 5 September 2007
Resolution: onboard
Engineering › Compressed Air System (control) › Valve
Issued 17 January 2007 Resolved
Provide a proper size safety relief valve on compressor tank.
Due 17 January 2007
Resolved 17 January 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 January 2006 Resolved
Reach rod tool missing.
Due 5 February 2006
Resolved 6 January 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 January 2006 Resolved
Support bracket bolts for #1 reach rod are wasted.
Condition: Unknown
Due 5 February 2006
Resolved 6 January 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 January 2006 Resolved
Engine room bilge alarms not working.
Due 5 February 2006
Resolved 6 January 2006
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 5 January 2006 Resolved
Fire alarm located in engine room not working.
Condition: Unknown
Due 5 February 2006
Resolved 6 January 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 14 September 2005 Resolved
Crop and renew bulkhead in shaft alley appox. 3'x8'.
Due 14 October 2005
Resolved 4 October 2005
Construction/Loadline › Hull › Stiffener
Issued 14 September 2005 Resolved
Crop and renew the wasted flanges of overhead brackets in rudder void space.
Due 14 October 2005
Resolved 4 October 2005
Construction/Loadline › Hull › Stiffener
Issued 14 September 2005 Resolved
Crop and renew vertical flat bar stiffeners in transverse tunnel of old ballast tanks.
Due 14 October 2005
Resolved 4 October 2005
Engineering › Steering Gear System › Actuator
Issued 24 April 2005 Resolved
Prove proper operation of steering system in all modes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2005
Resolved 25 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 December 2004 Resolved
Divide child and adult life jackets.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 December 2004 Resolved
Properly label breakers in enginerom electrical panel.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 December 2004 Resolved
Provide drip shield for switchboard.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 7 December 2004 Resolved
Provide matting for deck around switchboard.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 7 December 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 December 2004 Resolved
Provide safety seal for CO2 extinguisher on deck.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 7 December 2004
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 7 December 2004 Resolved
Provide valve plug for oil tank drain valve.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 December 2004 Resolved
Provide oil pressure and jacket water temp guages for #2 SSDG.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 December 2004 Resolved
Properly repair lube oil guages for both MDE oat operating station.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 December 2004 Resolved
Provide clear access to man overboard recovery station.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2004
Resolved 6 January 2006
Documentation › Certificates/Documents › FCC SSL
Issued 7 December 2004 Resolved
Provide FCC Radio Safety Certificate.
Condition: Placed in Improper Service
Due 7 January 2005
Resolved 6 January 2006
Communications › Alarms/Indicators
Issued 24 December 2003 Resolved
Properly label alarm panels in wheelhouse. LEGACY COMPONENT DESC: High Water Alarm
Due 23 January 2004
Resolved 22 January 2004
Engineering › Bilge Water Management System › Piping
Issued 23 December 2003 Resolved
Provide a fixed means to de-water the void tanks (x-ballast tanks) .
Due 23 December 2005
Resolved 6 January 2006
Electrical › Electric Generation Source (service)
Issued 23 December 2003 Resolved
Repair/ replace frequency meter on main switch board. LEGACY COMPONENT DESC: Panelboard
Due 23 January 2004
Resolved 22 January 2004
Electrical › Electric Generation Source (service)
Issued 23 December 2003 Resolved
Repair/replace voltage meter on #1 genset. LEGACY COMPONENT DESC: Panelboard
Due 23 January 2004
Resolved 22 January 2004
Communications › Alarms/Indicators
Issued 23 December 2003 Resolved
Prove proper operation of fire detector in engine room. LEGACY COMPONENT DESC: Fire Alarm
Due 23 January 2004
Resolved 22 January 2004
Documentation › Markings/Placards
Issued 23 December 2003 Resolved
Provide a legible oil pollution placard. LEGACY COMPONENT DESC: Oil Discharge Placard
Due 23 January 2004
Resolved 22 January 2004
Engineering › Compressed Air System (start air)
Issued 23 December 2003 Resolved
Hydro-test air recievers in engine room. LEGACY COMPONENT DESC: Receiver/Bottle
Due 23 January 2004
Resolved 22 January 2004
Electrical › Electrical Distribution System (service)
Issued 14 October 2003 Resolved
Remove or prove safe all dead ended cables in engine room. LEGACY COMPONENT DESC: Wiring
Due 14 November 2003
Resolved 23 December 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 October 2003 Resolved
Renew flexible fuel hose pig tails at #1 main engine.
Due 14 November 2003
Resolved 23 December 2003
Engineering › Compressed Air System (start air)
Issued 14 October 2003 Resolved
Remove un-used piping in engine room. LEGACY COMPONENT DESC: Piping
Due 14 November 2003
Resolved 23 December 2003
Engineering › Bilge Water Management System
Issued 14 October 2003 Resolved
Prove suction through fixed bilge pipng in all spaces served. LEGACY COMPONENT DESC: Piping
Due 14 November 2003
Resolved 23 December 2003
Electrical › Electric Generation Source (service)
Issued 14 October 2003 Resolved
Provide a battery box for starting battery of #2 genset. LEGACY COMPONENT DESC: Generator
Due 14 November 2003
Resolved 23 December 2003
Construction/Loadline › Structures
Issued 14 October 2003 Resolved
Make repairs to void stiffeners as marked. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 14 November 2003
Resolved 23 December 2003
Construction/Loadline
Issued 28 November 2001 Resolved
Replace corroded/inop handle for bilge system leading to steering compartment No. 1.
Condition: Unknown
Due 8 December 2001
Resolved 30 November 2001
Electrical
Issued 28 November 2001 Resolved
Repair watertight cover on exposed area(s) of shore-tie.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Lifesaving
Issued 28 November 2001 Resolved
Prover proper operation of winch used to rescue a man overboard.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Electrical
Issued 28 November 2001 Resolved
Renew frayed/split electrical cable shield leading to junction/outlet box in steering compartment No. 1.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Construction/Loadline
Issued 28 November 2001 Resolved
Replace broken reach rod for bilge system leading to steering compartment No. 2.
Condition: Unknown
Due 8 December 2001
Resolved 30 November 2001
Lifesaving
Issued 28 November 2001 Resolved
Replace inop batter in ring buoy light.
Condition: Unknown
Due 8 December 2001
Resolved 30 November 2001
Electrical
Issued 28 November 2001 Resolved
Replace wire/wing nuts on elcetrical steering controller in steering compartment No. 2 with proper watertight connections.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Construction/Loadline
Issued 28 November 2001 Resolved
Prove proper operation of the #2 shaft alley high level bilge alarm resulting in a visual and audio indication.
Condition: Unknown
Due 28 November 2001
Resolved 28 November 2001
Construction/Loadline
Issued 4 October 2001 Resolved
CROP AND RENEW THE TWO(2) MANHOLE RINGS IN THE MAIN DECK FOR THE #2 WRAP AROUND TANK.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Construction/Loadline
Issued 4 October 2001 Resolved
IN THE ENGINEROOM, REPAIR THE SIX (6) OVERHEAD TRANSVERSE ANGLE STIFFENERS HAVING SQUARE CUT HOLES.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Electrical
Issued 17 November 1999 Resolved
ADJUST OR MODIFY MAIN ELECTRICAL POWER PANEL DOOR LOCATED IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Lifesaving
Issued 17 November 1999 Resolved
AFTER RELOCATION, PRESENT FOR INSPECTION NEW START/STOP SWITCH, OIL PRESSURE, WATER TEMP GAUGE PANEL FOR BOTH MAIN ENGINES.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 17 November 1999 Resolved
REPLACE WASTED WATERTIGHT HATCHES ON SECOND DECK, FORE AND AFT OF BRIDGE.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Documentation
Issued 17 November 1999 Resolved
UPDATE EMERGENCY CHECKOFF LIST TO CORRECTLY REFLECT VESSEL CONFIGURATION AND PROCEDURES.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Documentation
Issued 19 November 1997 Resolved
PROVIDE COMPLETE DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 CFR PART 16.
Condition: Unknown
Due 18 December 1997
Resolved 31 December 1997
Documentation
Issued 13 December 1995 Resolved
Provide current documentation certificate.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Fire Fighting
Issued 13 December 1995 Resolved
Provide suitable portable hand fire pump.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Lifesaving
Issued 13 December 1995 Resolved
Provide Instructions for PFDs on board.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Engineering
Issued 13 December 1995 Resolved
Provide Coast Guard approved fuel hoses for Main Diesel engines.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Fire Fighting
Issued 13 December 1995 Resolved
Prove proper operation of ships fire pump.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Engineering
Issued 13 December 1995 Resolved
Properly label fuel cut off valves.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Documentation
Issued 13 December 1995 Resolved
Provide current copy of required CFRs, Nav rules & charts.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Navigation
Issued 13 December 1995 Resolved
Provide proper navigational lights.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Fire Fighting
Issued 13 December 1995 Resolved
Move CO2 extinguisher at Eng room door to ensure horn is not used as door holder.
Condition: Unknown
Due 1 February 1996
Resolved 1 February 1996
Documentation
Issued 6 October 1995 Resolved
Provide copy of ABS drydock report to include all readings and clearances taken.
Condition: Unknown
Due 6 November 1995
Resolved 27 November 1995
Navigation
Issued 12 May 1995 Resolved
Properly repair damaged rudder pintle bearing. Provide copy of final ABS report to clear.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Navigation
Issued 19 December 1994 Resolved
Properly mount hydraulic block located in #1 steering system.
Condition: Unknown
Due 25 January 1995
Resolved 25 January 1995
Accommodation/Occupational Safety
Issued 19 December 1994 Resolved
Replace ladder in shaft alley #1 end.
Condition: Unknown
Due 25 January 1995
Resolved 25 January 1995
Construction/Loadline
Issued 19 December 1994 Resolved
Prove proper operation of both fixed bilge system pumps no later than 26DEC94.
Condition: Unknown
Due 20 December 1994
Resolved 23 December 1994
Engineering
Issued 19 December 1994 Resolved
Hydrostatically test air receivers and related relief valves.
Condition: Unknown
Due 25 January 1995
Resolved 25 January 1995
Documentation
Issued 29 January 1992 Resolved
3: PROVIDE A WRITTEN WASTE MANAGEMENT PLAN
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Electrical
Issued 29 January 1992 Resolved
6: PROVIDE COVERS AND BLOCK BATTERY FROM MOVEMENT
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Fire Fighting
Issued 29 January 1992 Resolved
4: REPLACE FLEX HOSE ON THE DISCHARGE SIDE OF THE FIRE PUMP.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Fire Fighting
Issued 29 January 1992 Resolved
5: PROVE PROPER OPERATION OF CO2 OPERATED VENT, DAMPER, AND TIME DELAY W/_x001C_ SIREN.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Lifesaving
Issued 29 January 1992 Resolved
7: RE-ATTACH THE HYDROLIC LINE PIPE BRACKETS 1ST COMPT. AFT AREA.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Lifesaving
Issued 29 January 1992 Resolved
8: PROVIDE SUPPORTS FOR ALL CABLES & PIPING AS REQUIRED BELOW MAIN DECK
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Lifesaving
Issued 29 January 1992 Resolved
9: PROVIDE PROTECTIVE GLOBES FOR LIGHT FIXTURES
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Navigation
Issued 29 January 1992 Resolved
PROVIDE AND POST OPERATING INSTRUCTIONS FOR STEERING GEAR SYSTEM (HAND OPERATION).
Condition: Unknown
Due 29 January 1992
Resolved 29 January 1992
Fire Fighting
Issued 29 January 1992 Resolved
PROVE PROPER OPERATION OF THE INSTALLED FIRE PUMP.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Lifesaving
Issued 24 January 1991 Resolved
PROVIDE A RESCUE PLATFORM OR PROVE THE VESSEL CAN ACT AS THE PLATFORM IAW MEMO LETTER DATED 01JUN82 AND 46 CFR 180.10-35.
Condition: Unknown
Due 15 March 1991
Resolved 7 October 1991
Construction/Loadline
Issued 24 January 1991 Resolved
MAKE THE AFT STEERING COMPT FORWARD BULKHEAD WATERTIGHT IN WAY OF THE HYDRAULIC LINES PENETRATE.
Condition: Unknown
Due 15 March 1991
Resolved 7 October 1991
Fire Fighting
Issued 24 January 1991 Resolved
PROVIDE AND PROVE PROPER OPERATION OF THE HAND PORTABLE FIRE PUMP IAW 46 CFR 181.10-5.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 1 February 1990 Resolved
PROVE OPERATION OF BOTH COLLOSION COMPARTMENT BILGE VALVES SHUT-OFFS.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Electrical
Issued 1 February 1990 Resolved
PROVIDE COVERS FOR LIGHTS IN ENGINE ROOM.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Electrical
Issued 1 February 1990 Resolved
PROVIDE COVERS FOR ELECTRICAL JUNCTION BOXES TO STEERING PUMPS IN ENGINE ROOM.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Engineering
Issued 1 February 1990 Resolved
PROVIDE 1 INCH INSIDE DIAMETER, MINIMUM, PRESSURE RELIEF VALVES FOR AIR RECEIVERS.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Navigation
Issued 12 February 1988 Resolved
REPLACE BROKEN STERN LIGHT.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Engineering
Issued 12 February 1988 Resolved
INSTALL GUARDS OVER FWD. AND AFT. MN. ENG. POWER TAKE-OFFS.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Electrical
Issued 12 February 1988 Resolved
PROVIDE PROPER METAL CUPS UNDER RACOR FUEL FILTERS FOR #2 S/S GEN.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Electrical
Issued 12 February 1988 Resolved
REPLACE ALL UNAPPROVED FLEX. FUEL HOSES WITH AN APPROVED TYPE ON #2 S/S GEN
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988

Casualty record · 3

30 November 2001Routine · role: Involved in a Marine Casualty · activity 1484536
12 March 2011Routine · role: Involved in a Marine Casualty · activity 3964676
13 October 2017Routine · role: Involved in a Marine Casualty · activity 6289388
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record