MAURY USCG vessel records Sign in
← All vessels

PELICAN PRINCESS

PELICAN PRINCESS is a 1982 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1985, most recently in October 1997, along with 121 deficiencies.

Records from 1985 to 1997. Most recent: inspection, 3 October 1997.

Built
1982
Last inspected
3 October 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTV4993
Flag
BAHAMAS, THE
—
Maury page id
psix-54413

Inspections, by type

…with no type recorded6
Years with a record 13 calendar years (1985–1997)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WTV4993MMSI not assigned · expired · compulsorily equipped · granted 6 June 1996, cancelled 21 October 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 41

3 October 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 789062
3 October 1997 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1121287
1 July 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 777640
2 June 1997 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109435
2 June 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1112611
26 July 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1092839
10 June 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1089381
6 June 1996 Hull Examination · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 875498
28 March 1996 Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1079441
26 July 1995 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 884222
13 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 840982
29 August 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1177440
10 August 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1174519
3 August 1994 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 867398
16 June 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1172477
9 May 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1014319
11 March 1994 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 855233
23 November 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1152494
22 October 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1449646
13 August 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1139465
8 June 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 838044
17 September 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1253351
17 August 1992 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 944634
31 March 1992 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 957433
22 August 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1268121
20 September 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 901454
24 August 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1228085
23 August 1990 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1223400
28 November 1989 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1238867
30 August 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1039268
1 March 1989 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1198209
1 February 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1210777
7 September 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1040562
15 September 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1313189
10 September 1987 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1003795
13 August 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336579
3 February 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1012033
25 August 1986 Deficiency Check · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991278
24 September 1985 Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1297884
30 August 1985 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1297882
25 April 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 983634

Deficiency record · 121

Documentation
Issued 26 July 1996 Resolved
INITIATE REQUIRED CREW TRAINING LOG BOOKS.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 26 July 1996 Resolved
PERMANENTLY CAP THE OLD GENERATOR EXHUAST PIPING RUNNING THROUGH THE TRANSOM.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Fire Fighting
Issued 26 July 1996 Resolved
RELOCATE FIRE AXE TO MAKE MORE ACCESSABLE (NOT IN ENGINE ROOM) FOR EMERGENCY USE.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 26 July 1996 Resolved
INSTALL LANYARD TO THE AFT DECK WATER TIGHT HATCH COVER.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Accommodation/Occupational Safety
Issued 26 July 1996 Resolved
INSURE MARINE SANITATION DEVICE'S OVERBOARD DISCHARGE VALVE IS LOCKED IN THE CLOSED POSITION WHEN VESSEL IS WITHIN THE THREE MILE LIMIT FROM SHORE.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Engineering
Issued 26 July 1996 Resolved
INSTALL DOUBLE LOCKING DEVICES ON ALL ENGINES THROTTLES AND REDUCTION GEARSCABLE CONNECTIONS.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Documentation
Issued 26 July 1996 Resolved
INITIATE AN APPROVED RANDOM DRUG TESTING PROGRAM FOR EMPLOYEES NOT COVERED WITH CONSORTIUM HIRED BY COMPANY.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Lifesaving
Issued 26 July 1996 Resolved
LABEL CHILD SIZE LIFE JACKET STORAGE CONTAINERS TO SHOW LOCATION AND AMOUNTOF JACKETS STOWED._x001C_
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Documentation
Issued 26 July 1996 Resolved
PROVIDE AND POST IN VESSEL'S BRIDGE, ORIGINAL SIGNED STABILITY LETTER ISSUED TO THE VESSEL.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Navigation
Issued 26 July 1996 Resolved
POST AT HELM STATION A CURRENT COMPASS DEVIATION TABLE.
Condition: Unknown
Due 26 July 1996
Resolved 26 July 1996
Navigation
Issued 6 June 1996 Resolved
Repair & make operable the rudder packing gland nuts, prior to carrying passengers.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Construction/Loadline
Issued 6 June 1996 Resolved
Remark draft markings prior to carrying passengers.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Navigation
Issued 6 June 1996 Resolved
Replace wasted gussets on steering gear framing, aftersteering space, priorto carrying passengers.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Accommodation/Occupational Safety
Issued 6 June 1996 Resolved
Retighten hand rail attachments throughout vessel, to be accomplished priorto carrying passengers.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Construction/Loadline
Issued 26 July 1995 Resolved
Effect permanent repairs in way of the rot area to the transverse support deck beam, port side collision compartment (forepeak)
Condition: Unknown
Due 26 July 1995
Resolved 26 July 1995
Engineering
Issued 26 July 1995 Resolved
Modify fuel tank vent lines to terminate above the Main Deck in a "U-bend" as required by 46 CFR 182.20-35(c)
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Documentation
Issued 26 July 1995 Resolved
Post the vessel Stability Letter on the bridge so that all pages are visible.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Accommodation/Occupational Safety
Issued 26 July 1995 Resolved
Effect permanent repairs to forward C/L passenger cabin window.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Electrical
Issued 26 July 1995 Resolved
Effect permanent repairs and prove proper operation of STBD Diesel Generator.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 26 July 1995 Resolved
Effect permanent repairs and prove operation of the port diesel engine Jabsco fire/bilge pump.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Lifesaving
Issued 26 July 1995 Resolved
Replace retroflective tape on all PFDs as needed.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Fire Fighting
Issued 26 July 1995 Resolved
Provide a spanner wrench for each of the 1 1/4 inch fire hose stations.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Engineering
Issued 26 July 1995 Resolved
Extend engine room exhaust vent duct to a point near the bottom of the compartment as required by 46 CFR 182.20-45(c)
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Lifesaving
Issued 26 July 1995 Resolved
Provide grab lines for the STBD life float
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Electrical
Issued 3 August 1994 Resolved
HARNESS ALL ELECTRICAL WIRING IN THE ENGINE COMPARTMENT OVERHEAD WITH METALSUPPORTS.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Construction/Loadline
Issued 3 August 1994 Resolved
PROVE PROPER OPERATION OF THE VESSELS BILGE SYSTEM.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 3 August 1994 Resolved
REFASTEN HAND RAILS, FORWARD ON BOTH THE PORT & STBD SIDES.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Construction/Loadline
Issued 3 August 1994 Resolved
EFFECT PERMANENT REPAIRS AND PROVE PROPER OPERATION TO THE MDE BELT DRIVEN FIRE/BILGE PUMP.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Navigation
Issued 3 August 1994 Resolved
PROVIDE NAVIGATION PUBLICATIONS, NOTICES, LISTS, AND TIDE TABLES.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 3 August 1994 Resolved
PROVIDE A TALK BACK COMMUNICATION SYSTEM OR HAND PORTABLE VHF RADIO'S. _x001C_DURING PERSON OVERBOARD RECOVERY OPERATIONS. LOCATIONS THE MAIN DECK AND THE MASTER IN PILOT HOUSE.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Navigation
Issued 3 August 1994 Resolved
CROP AND RENEW THE DETERIORATED STEEL GUSSET SUPPORTS TO THE STBD HYDRAULICOIL PISTON ON THE STEERING SYSTEM.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 3 August 1994 Resolved
REFASTEN THE GALLEY 110V ELECTRICAL COOKING GRILL.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Accommodation/Occupational Safety
Issued 3 August 1994 Resolved
REFASTEN THE AFT LADDER TO THE UPPER DECK. CROP AND RENEW ROT FACING BOARD LOCATED AFT, ADJACENT TO WOOD LADDER ON UPPER DECK.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 3 August 1994 Resolved
LIFE FLOATS: PROVIDE TWO (2) 100' PAINTER LINES (LOCATED BETWEEN LIFE FLOAT AND FLOAT FREE LINK). PROVIDE WATERLIGHT FOR STBD LIFEFLOAT.
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Lifesaving
Issued 3 August 1994 Resolved
EPIRB: RENEW BATTERY AND PROVE PROPER OPERATION.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 3 August 1994 Resolved
RING BUOYS: 2ND DECK-PROVIDE RING BUOY OR REPAIR GRAB LINES. _x001C_ MAIN DECK-RENEW RING BUOY RETROREFLECTIVE TAPE.
Condition: Unknown
Due 4 August 1994
Resolved 4 August 1994
Lifesaving
Issued 3 August 1994 Resolved
LIFE PRESERVERS: PROVIDE 4 ADULT AND 1 CHILDS LIFE PRESERVER, TYPE I._x001C_ RENEW RETROREFLECTIVE TAPE ON BOTH ADULT AND CHILDRENS LIFE PRESERVERS AS NEEDED.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Lifesaving
Issued 3 August 1994 Resolved
LIFE PRESERVERS: PROVIDE 55 PFD WATERLIGHTS.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Electrical
Issued 3 August 1994 Resolved
ENGINE ROOM: REMOVE DEAD END 110V/12V ELECTRICAL WIRING FROM THE OVERHEAD AND ABOVE THE MAIN DIESEL ENGINES. REMOVE WIRE NUTS THROUGH OUT VESSEL.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Navigation
Issued 3 August 1994 Resolved
EFECT PERMANENT REPAIRS TO THE PORT SIDE STEERING SYSTEM IN WAY OF A HYDRAULIC OIL PISTON LEAKING SEAL.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Construction/Loadline
Issued 11 March 1994 Resolved
IN THE ENGINEROOM, REMOVE ALL DRY ROT AND REPAIR TO ORIGINAL THE DECK GUSSETS 2,4,5,6, & 7 ON BOTH PORT & STBD SIDES.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Construction/Loadline
Issued 11 March 1994 Resolved
IN THE ENGINEROOM, REMOVE AND REPAIR TO ORIGINAL THE PORT AND STBD PLYWOOD VENTS.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Engineering
Issued 11 March 1994 Resolved
MAKE PERMANENT REPAIRS TO THE PORT MDE EXHAUST PIPE.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 11 March 1994 Resolved
EFFECT PERMANENT REPAIRS TO THE FRP FRACTURES AND CRACKED WOOD RUB RAIL, LOACATED ON PORT SIDE ADJACENT TO FORWARD TOWING BITT.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 11 March 1994 Resolved
IN THE ENGINEROOM, REMOVE ALL DRY ROT AND REPAIR TO ORIGINAL THE PORT AND STBD LONGITUDINAL UNDERDECK BEAMS.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Construction/Loadline
Issued 11 March 1994 Resolved
IN THE ENGINEROOM, REMOVE ALL DRY ROT AND REPAIR TO ORIGINAL THE MAIN DECK CLAMP IN WAY OF FRAMES 8 & 9 PORT, FRAME 5 & 6 PORT, FRAME 10 & 11 STBD, AND FRAME 5 & 6 STBD.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Construction/Loadline
Issued 11 March 1994 Resolved
IN THE ENGINEROOM, REPAIR THE STBD PLYWOOD VENT BOX AFT OF THE ENGINE.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 11 March 1994 Resolved
IN THE FORWARD COMPARTMENT, REMOVE AND REPAIR TO ORIGINAL THE PORT SIDE FRAMES 1,2, & 3, STBD SIDE FRAME 2. DECK CLAMP PORT SIDE ADJACENT TO FRAMES 1-4.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 11 March 1994 Resolved
REPLACE MISSING THROUGH BOLT FASTENERS ON PORT AND STBD DECK CLAMPS.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Electrical
Issued 11 March 1994 Resolved
RENEW THE PORT DIESEL GENERATOR EXPANSION TANK.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 11 March 1994 Resolved
REMOVE THE HARD WIRED ELECTRICAL EXTENSION CORD WITH PROPER CABLE.
Condition: Unknown
Due 9 May 1994
Resolved 23 May 1994
Electrical
Issued 11 March 1994 Resolved
RENEW THE IMPROPER FOUR RECEPTACLE PLUG IN THE ENGINEROOM TO A MARINE TYPE.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Deck/Cargo
Issued 11 March 1994 Resolved
REPAIR THE ALUM BOW SPRINT, IN WAY OF WASTED AND FRACTURED SUPPORT PLATE.
Condition: Unknown
Due 11 March 1994
Resolved 11 March 1994
Electrical
Issued 23 November 1993 Resolved
SHOW PROPER OPERATION OF THE OVERSPEED DEVICE ON THE PORT GENERATOR.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Lifesaving
Issued 22 October 1993 Resolved
PRIOR TO THE MOVEMENT OF THE VESSEL, THE OPERATOR IS TO NOTIFY COAST GUARD MARINE SAFETY DETACHMENT PORT CANAVERAL OR THE OFFICER IN CHARGE MARINE INSPECTION JACKSONVILLE FL 24 HOURS IN ADVANCE.
Condition: Unknown
Due 30 October 1993
Resolved 29 October 1993
Engineering
Issued 22 October 1993 Resolved
CORRECT THE OIL LEAK AT THE FRONT OF THE PORT ENGINE AND CORRECT THE EXCESSIVE CRANKCASE PRESSURE IN THE PORT ENGINE.
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Accommodation/Occupational Safety
Issued 13 August 1993 Resolved
REPAIR BROKEN BASE PLATE ON HAND RAIL, UPPER DECK STARBOARD SIDE._x001C_
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Engineering
Issued 13 August 1993 Resolved
INSTALL DUCTING FOR VENTILATION SYSTEM IN ENGINE ROOM, IAW 46 CFR 182.020- 45 (c) AND (d).
Condition: Unknown
Due 13 September 1993
Resolved 7 September 1993
Electrical
Issued 13 August 1993 Resolved
PROVE PROPER OPERATION OF ALL ENGINE CONTROL INSTRUMENTS, GAUGES, TO THE BRIDGE.
Condition: Unknown
Due 1 November 1993
Resolved 1 November 1993
Electrical
Issued 13 August 1993 Resolved
PROVE PROPER OPERATION OF OVERSPEED, HI-TEMP, LOW LUBE SHUTDOWNS AND ALARMSON BOTH GENERATORS.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Engineering
Issued 17 August 1992 Resolved
DOULBE HOSE CLAMP ALL WATER LINES IN MACHINERY SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Electrical
Issued 17 August 1992 Resolved
INSTALL DRIP SHIELDS OVER SWITCHBOARDS AND BATTERYU CHARGERS IN MACHINERY_x001C_ SPACE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Engineering
Issued 17 August 1992 Resolved
SUPPORT ALL PVC PIPING IN ENGINE ROOM, HANGERS OR BRACKETS REQUIRED ON EACHFOUR (4) FEET._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Accommodation/Occupational Safety
Issued 17 August 1992 Resolved
STELCIL AREA OF OVERBOARD DISCHARGE FROM SEWAGE, DO NOT OPEN WHILE IN U.S._x001C_WATERS (3 MILES)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Accommodation/Occupational Safety
Issued 17 August 1992 Resolved
INSTALL GATE VALVE AT THRU HULL PENETRATION FOR SEWAGE TANK OVERFLOW LINE._x001C_STENCIL SAME AS ITEM 9._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Engineering
Issued 17 August 1992 Resolved
HARD PIPE FUEL SYSTEM TO STARBOARD GENERATOR 30" FLEXIBLE LINE ALLOWED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Navigation
Issued 17 August 1992 Resolved
INSTALL FLAT WASHERS TO THE TOP OF THE PINS ON BOTH STEERING RAM ATTACHMENTS (TOTAL OF 4)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Lifesaving
Issued 17 August 1992 Resolved
INSTALL HYDROSTATIC RELEASES ON BOTH LIFEFLOATS OR CHANGE ARRANGEMENT TO_x001C_ FLOAT FREE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Lifesaving
Issued 17 August 1992 Resolved
REPLACE PADDLES IN BOTH LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Lifesaving
Issued 17 August 1992 Resolved
CORRECT OPERATION OF FLOAT LIGHT FOR WHEEL HOUSE LIFE RING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Electrical
Issued 17 August 1992 Resolved
RELABLE SWITCHBOARD FOR GENERATOR IN MACHINERY SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Navigation
Issued 17 August 1992 Resolved
REPLACE THE HF/SSB RADIO PRIOR TO COMPLETION DATE. ROUTE LIMITED TO 20 MILES UNTILL CORRECTED.
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Lifesaving
Issued 17 August 1992 Resolved
PROVIDE A SUITABLE RESCUE BOAT SATISFACTORY TO THE [name withheld]._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Electrical
Issued 17 August 1992 Resolved
RESET OVERSPEED TRIP ON STARBOARD GENERATOR TO TRIP NOT GREATER THAN 15%_x001C_ ABOVE 1200 RPM'S OR 1380 RPM'S._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Construction/Loadline
Issued 24 August 1990 Resolved
REPLACE HATCH GASKET FOR AFT LAZARETTE.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Construction/Loadline
Issued 24 August 1990 Resolved
MAKE PERMANENT REPAIRS TO WATERTIGHT BULKHEAD BETWEEN ENGINE ROOM AND AFT LAZARETTE ALL THRU BULKHEAD EXHAUST PIPES CONNECTIONS TO BULKHEAD ARE CRACKED.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Accommodation/Occupational Safety
Issued 24 August 1990 Resolved
INSTALL MARPOL V (GARBAGE) PLACARDS THROUGH OUT VESSEL AND PREPARE THE REQUIRED WASTE MANAGEMENT PLAN FOR INSPECTION.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Construction/Loadline
Issued 24 August 1990 Resolved
PROVE WATERTIGHT INTEGRITY OF WATERTIGHT BULKHEADS AT FRAMES 4, 14, 24, AND39.
Condition: Unknown
Due 24 August 1990
Resolved 24 August 1990
Lifesaving
Issued 23 August 1990 Resolved
RELOCATE/INSTALL ONE RING LIFE BOUY FORWARD AND ONE AFT ON THE MAIN DECK. RING LIFE BOUY WITH LIGHT SHOULD REMAIN AT WHEEL HOUSE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
REPAIR AND TEST FRESH WATER TANK AND PROVE OPERATION OF VESSEL'S FRESH WATER SYSTEM.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
REMOVE PLASTIC LEVEL INDICATING TUBING FROM FUEL TANKS AND CAP OFF ALL CONNECTIONS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REPAIR EMERGENCY LIGHT IN WHEEL HOUSE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
REPLACE PVC PIPING IN BOTH GENERATOR SALT WATER COOLING SYSTEMS WITH CORROSION RESISTANT METALLIC PIPE AND FITTINGS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
INSTALL OIL POLLUTION PLACARD AT ELECTRIC CONTROLS FOR SUBMERSIBLE BILGE PUMPS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REPAIR DOOR ON CIRCUIT BREAKER PANEL IN ENGINE ROOM. ALSO IDENTIFY/LIST SERVICE OF EACH CIRCUIT BREAKER INSIDE DOOR.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
GALLEY ELECTRIC PANEL, INSTALL BLANKS OR BREAKERS IN MISSING BREAKER SLOTS. ALSO IDENTIFY/LIST SERVICE OF EACH CIRCUIT BREAKER INSIDE DOOR.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Navigation
Issued 23 August 1990 Resolved
REPAIR AND PROVE OPERATION OF VESSEL'S SINGLE SIDE BAND RADIO. THE VESSEL IS RESTRICTED TO COASTWISE NOT MORE THAN 20 MILES FROM SHORE UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Fire Fighting
Issued 23 August 1990 Resolved
PROVIDE AND PROVE OPERATION OF A HAND PORTABLE FIRE/BILGE PUMP WITH SUCTION AND DISCHARGE HOSES.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Documentation
Issued 23 August 1990 Resolved
PROVIDE PROOF OF ADDRESS CHANGE FOR THE VESSEL FROM MIAMI CG DOCUMENTATION OFFICE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REPAIR THE INOP DECK LIGHTS PORT AND STBD.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REPAIR SEARCHLIGHT.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
REWIRE WATER WASH DOWN PUMP ELECTRIC MOTOR. REMOVE SPLICED WIRES. USE APPROVED WIRE. USE DOUBLE HOSE CLAMPS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REATTACH VARIOUS LOOSE GROUND WIRES IN BILGES.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
INSTALL PROPER LAGGING ON ALL DIESEL ENGINE EXHAUST SYSTEMS FROM THE ENGINE MANIFOLD OUTLET TO EXHAUST WATER COOLING CONNECTION. ALSO LAG ALL TURBO HOT SURFACES.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
AFT LAZARETTE REMOVE HOSES/WIRING FOR TRIM TABS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
WHEEL HOUSE 110 VOLT BREAKER BOX INSTALL BLANKS OR MISSING BREAKERS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Lifesaving
Issued 23 August 1990 Resolved
PAINT LIFEFLOATS INTERNATIONAL ORANGE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Deck/Cargo
Issued 23 August 1990 Resolved
REPLACE DECK WINCH FORWARD.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
STOP ALL WATER LEAKS FROM HEADS AND PLUMBING PIPING INTO ENGINE ROOM. ALSO CONNECT ALL PLUMBING/OVERBOARD DRAINS PERMANENTLY.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
REPAIR WATER LEAKS ON FLEX HOSES ON PORT MDE EXHAUST PIPES.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
REPAIR PIN HOLE WATER LEAK IN CENTER MDE STBD SIDE EXHAUST PIPE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REPLACE LIGHT FIXTURE SCREENS OVER GLASS GLOBES IN ENGINE ROOM.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
REPAIR AND TEST 2O KW GENERATOR PINHOLE LEAKS IN ALUMINUM EXHAUST PIPE IN AFT LAZARETTE. RENEW ALL PVC EXHAUST PIPE WITH METALLIC PIPE IN AFT LAZAR- ETTE AND ENGINE ROOM, FLEX HOSE CONNECTIONS ARE TO BE AS SHORT AS POSSIBLE.RENEW ALL PVC PIPE IN SALT WATER LINE TO PRIME MOVER WITH METAL PIPE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
RENEW OIL SOAKED PLYWOOD DECK PLATES IN ENGINE ROOM AS NEEDED.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
FIBERGLASS BOTH GENERATOR BATTERY BOXES OR INSTALL LEAD TRAY AS REQUIRED.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
REPLACE V-BELTS AND PROVE OPERATION OF PORT AND STBD AIR FANS. ALSO, INSTALL SCREENS OR ENCLOSE DUCT AT AFT END OF PORT FAN.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Engineering
Issued 23 August 1990 Resolved
PROVIDE MAIN DIESEL ENGINE MANUFACTURER'S RECOMMENDED METHOD FOR ELIMINATING BLOW BY OIL FROM ENGINE VALVE COVER VENTS AND INSTALL SAME.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 23 August 1990 Resolved
REPLACE GUARD OVER AIR COMPRESSOR V-BELT AND PULLEYS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Electrical
Issued 23 August 1990 Resolved
REWIRE CENTER ENGINE ALTERNATOR REPLACE SPLICED WIRE CONNECTIONS.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Fire Fighting
Issued 23 August 1990 Resolved
REPLACE GAUGE ON ELECTRIC FIRE PUMP DISCHARGE. ALSO TEST PUMP, MUST HAVE MIN. 60 PSI DISCHARGE PRESSURE.
Condition: Unknown
Due 23 August 1990
Resolved 23 August 1990
Accommodation/Occupational Safety
Issued 30 August 1989 Resolved
PROVIDE GUARDS (SCREENS) FOR BOTH ENGINE COMPARTMENT ELECTRICAL SUPPLY AND EXHAUST FANS/MOTORS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Navigation
Issued 30 August 1989 Resolved
PROVE PROPER OPERATION OF THE STERN NAVIGATION LIGHT AND SPOT LIGHT.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Construction/Loadline
Issued 30 August 1989 Resolved
MAKE WATER TIGHT OR REMOVE FROM THE FORWARD STEERING COMPARTMENT BULKHEAD. THE 12V WIRING AND BILGE PUMP DISCHARGE HOSE PENETRATING THE BULKHEAD.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Engineering
Issued 1 February 1989 Resolved
RECONNECT THE ATTACHED BONDING WIRE TO THE PORT AND STARBOARD FUEL TANKS FILL MAIN DECK CONNECTION.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Engineering
Issued 1 February 1989 Resolved
RENEW THE FLEXIBLE NONMETALLIC FUEL OIL FILL HOSES FROM THE TANK TOP TO MAIN DECK FILL CONNECTIONS PORT AND STARBOARD.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Lifesaving
Issued 7 September 1988 Resolved
PRIOR TO OPERATING VESSEL ONE HUNDRED (100) MILES FROM A HARBOUR OF SAFE REFUGE, PROVIDE EVIDENCE OF AN EPIRB INSTALLATION ABOARD VESSEL.
Condition: Unknown
Due 7 September 1988
Resolved 7 September 1988
Engineering
Issued 13 August 1987 Resolved
REPLACE CENTERLINE MAIN ENGINE EXHAUST EXPANSION JOINT
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Engineering
Issued 13 August 1987 Resolved
PROVIDE GROUNDING STRAPS TOP AND BOTTOM FOR FUEL TANKS
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Electrical
Issued 13 August 1987 Resolved
REPLACE ALL BATTERY BOXES
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Engineering
Issued 25 August 1986 Resolved
INSTALL PROPER TYPE FUEL OIL LINE TO S/S GENERATOR.
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986
Engineering
Issued 25 August 1986 Resolved
INSTALL FLAME SCREENS ON PORT AND STARBOARD FUEL OIL VENTS.
Condition: Unknown
Due 25 August 1986
Resolved 25 August 1986

Ownership record