Records from 1985 to 2020. Most recent: inspection, 7 January 2020.
Inspection history · 62
7 January 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6883234
10 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5812537
27 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5804571
6 July 2012
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4369595
12 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4223598
21 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4212172
30 June 2008
Damage Survey · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3254958
23 June 2008
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3249401
5 June 2008
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3234839
5 June 2007
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2951660
30 May 2006
Hull Examination · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2664702
12 January 2004
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1981820
13 October 2003
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1938949
25 March 2003
Hull Examination · Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1762574
24 April 2002
Hull Examination · COI Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1617818
16 August 2001
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1071133
20 October 2000
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1054859
24 August 2000
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 820934
2 May 2000
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 820500
2 November 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 818528
28 October 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1131725
27 May 1999
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1453614
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788836
28 July 1998
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1423051
22 April 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 131825
12 November 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1388405
8 September 1997
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1424482
4 August 1997
Excursion Permit
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 782151
30 June 1997
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1112097
30 June 1997
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1416544
22 November 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1179801
29 May 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1087139
15 May 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1084934
23 October 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182662
20 September 1995
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186693
27 June 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882787
12 June 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878288
6 June 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 222037
27 October 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870595
9 May 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870527
26 April 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1389804
18 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854749
9 November 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163043
13 May 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154405
15 May 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947660
8 April 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 947574
12 December 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947313
21 May 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235599
30 June 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926077
1 June 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 899806
18 May 1990
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 906933
5 May 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1351535
12 July 1988
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1207889
11 July 1988
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 896241
20 May 1987
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1024730
19 March 1987
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1017140
26 February 1987
Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1000587
2 June 1986
COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1294709
4 March 1986
Examination of Repairs
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 988002
2 January 1986
Examination of Repairs
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1294535
23 May 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1291733
17 April 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1290076
Construction/Loadline › Hull › Side Shell
Issued 6 July 2012
No resolution recorded
Numerous planks on starboard and port sides loose and require refastening. See narrative for detailed discrepancies and locations.
Action required: 705 - Other - as specified
Due 1 January 2013 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Tank
Issued 30 June 2008
Resolved
Ground fuel tank deck fill connection to tank.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 3 July 2008
Resolution: Had phonecon with O/O. He stated that the tank/connection have been grounded.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 30 June 2008
Resolved
Repair or replace and relocate emergency fuel shutoff valve.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 3 July 2008
Resolution: Had phonecon with O/O. He stated that a new ball valve was put in place and the valve is now 8" from the deck.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 30 June 2008
Resolved
Replace belt on auxiliary take off pump.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 3 July 2008
Resolution: Had phonecon with O/O. He stated that the belt has been replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 30 June 2008
Resolved
Provide servicing of fixed and portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2008
Resolved 1 July 2008
Resolution: Service invoice provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 June 2008
Resolved
Repair manual actuator on bottle to make as original installation.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 3 July 2008
Resolution: Had phonecon with O/O. The arangement has been fixed with the appropriate required part as it was in original installation.
Construction/Loadline › Hull › Bottom Plating
Issued 30 June 2008
Resolved
Make repairs to damage on port side resulting from vessel grounding. Repair to be inspected by USCG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2008
Resolved 30 June 2008
Resolution: Atteneded vessel for annual inspection. Conducted satisfcatory check ride and examination of repair.
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2007
Resolved
Provide valid FCC Station License.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 30 June 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 June 2007
Resolved
Mouse shackles used in rigging.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 2 July 2008
Resolution: Examined rigging satisfactory.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2007
Resolved
Provide halyard clip on waterlight.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 2 July 2008
Resolution: Halyard clips in place.
Engineering › Bilge Water Management System › Pump
Issued 5 June 2007
Resolved
Secure mounting of bilge bellows pump.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 2 July 2008
Resolution: Pump Secured.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 June 2007
Resolved
Provide servicing of fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2007
Resolved 30 June 2008
Resolution: Item was cleared last year by gary Moores but was vot cleared in MISLE.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 June 2007
Resolved
Prove proper operation of fixed system activation alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2007
Resolved 2 July 2008
Resolution: Tested system satisfactory.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 June 2007
Resolved
Repair leak at stuffing box.
Action required: 705 - Other - as specified
Due 5 July 2007
Resolved 2 July 2008
Resolution: Conducted check ride noting no leakage.
Communications › Radio Communications › VHF Radiotelephone
Issued 30 May 2006
Resolved
PROVIDE AN UPDATED RADIO SAFETY CERTICATE.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 31 May 2006
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 30 May 2006
Resolved
ENSURE THE EAP PHONE NUMBER IS CURRENT.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 31 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2006
Resolved
REPLACE FIRST AID KIT.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 28 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 30 May 2006
Resolved
PROVIDE 2 ADULT SIZE LIFE JACKETS.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 31 May 2006
Lifesaving › Lifejacket/PFD (Type IV) › Condition
Issued 30 May 2006
Resolved
PROVIDE 3 RING LIFE BOUYS AND OUTFIT THEM I.A.W. 46 CFR 180.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2006
Resolved 30 May 2006
Engineering › Bilge Water Management System › Strainer
Issued 30 May 2006
Resolved
INSTALL BILGE SUCTION STRAINER IN MID-SHIP COMPARTMENT.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 28 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 30 May 2006
Resolved
PROVIDE VENT CLOSURES FOR ENGINE COMPARTMENT.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 28 June 2006
Communications › Internal Communications System › Sound-powered Telephone
Issued 30 May 2006
Resolved
MAKE OPERABLE PUBLIC ADDRESS SYSTEM.
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 31 May 2006
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 30 May 2006
Resolved
TIGHTEN ALL LIFE LINES AROUND DECK.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 May 2006
Resolved
REMOVE ALL EXCESS HAND TOOLS, POWER TOOLS, AND GEAR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 May 2006
Resolved
COMPLETE SAIL RIG AND MOUSE/SEIZE ALL HOOKS AND SHACKLES.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 January 2004
Resolved
Install wire brackets in aft cabin for radar cable.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 29 July 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 12 January 2004
Resolved
Provide and post an emergnecy broadcast placard.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 21 July 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 January 2004
Resolved
Tighten safety rail stanchions as pointed out by the marine inspector.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 21 July 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 January 2004
Resolved
Properly mark life jacket stowage boxes.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 21 July 2004
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 January 2004
Resolved
Remove flammable liquids from #2 cabin.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 21 July 2004
Engineering › Bilge Water Management System › Manifold
Issued 12 January 2004
Resolved
Double clamp hoses on bilge manifold.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 29 July 2004
Electrical › Electrical Distribution System (service)
Issued 25 March 2003
Resolved
Dress up wiring in 12 volt distribution panel. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 3 June 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 March 2003
Resolved
Make operable the audible high bilge alarm in the captain's compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 3 June 2003
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 25 March 2003
Resolved
Weigh the engine compartment fixed fire extinguishing bottle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 3 June 2003
Lifesaving › Buoyant Apparatus
Issued 25 March 2003
Resolved
Install 2 float lights on lifefloats.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 3 June 2003
Communications › Radio Communications › EPIRB
Issued 25 March 2003
Resolved
Install new hydrostatic release on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 3 June 2003
Construction/Loadline › Hull › Bottom Plating
Issued 24 April 2002
Resolved
Investigate loose plank ends marked by the marine inspector and refasten to good wood.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2002
Construction/Loadline › Hull › Bottom Plating
Issued 24 April 2002
Resolved
Repair plank stbd side loacted below waterline as pointed out by the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2002
Construction/Loadline › Structures
Issued 24 April 2002
Resolved
Investigate and repair deck beams on port side main deck in way of cabins 2 & 4 to a satisfactory condition. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Investigate loose portside chain plate bolts as pointed out by the marine inspector. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Documentation
Issued 24 August 2000
Resolved
POST COI
Condition: Unknown
Due 24 September 2000
Resolved 29 August 2000
Lifesaving
Issued 24 August 2000
Resolved
RENEW ALL (3) RING BUOYS.
Condition: Unknown
Due 24 August 2000
Resolved 29 August 2000
Fire Fighting
Issued 24 August 2000
Resolved
INSTALL SMOKE DETECTORS IN ALL OVERNIGHT ACCOMODATION SPACES.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Lifesaving
Issued 24 August 2000
Resolved
PROVIDE PML'S FOR ALL LIFEJACKETS.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Documentation
Issued 24 August 2000
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 24 September 2000
Resolved 29 August 2000
Fire Fighting
Issued 24 August 2000
Resolved
REPAIR FIRE AND BILGE PUMP
Condition: Unknown
Due 24 August 2000
Resolved 29 August 2000
Lifesaving
Issued 27 May 1999
Resolved
HAVE LIFE RAFTS SERVICED AT A CERTIFIED LIFE RAFT FACILITY.
Condition: Unknown
Due 30 June 1999
Resolved 20 July 1999
Fire Fighting
Issued 27 May 1999
Resolved
INSTALL AUTOMATIC ACTIVATION AND AUTOMATIC ENGINE SHUTDOWN FEATURE ON THE ENGINE COMPARTMENT FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 6 August 1999
Resolved 9 August 1999
Lifesaving
Issued 27 May 1999
Resolved
PURCHASE SIX PERSONAL MARKER LIGHTS FOR LIFE PRESERVERS. VESSEL IS RESTICTED TO 16 PASSENGERS ON OCEAN VOYAGES UNTIL THIS REQUIREMENT IS CORRECTED.
Condition: Unknown
Due 30 June 1999
Resolved 20 July 1999
Electrical
Issued 28 July 1998
Resolved
Replace the batteries in the flashlights used for emergency lighting as necessary.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Engineering
Issued 28 July 1998
Resolved
Replace worn hose on wet exhaust.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Lifesaving
Issued 28 July 1998
Resolved
Add lights to child size life jackets.
Condition: Unknown
Due 31 August 1998
Resolved 11 August 1998
Documentation
Issued 28 July 1998
Resolved
Develop and maintain a log of crew training, man overboard, abandon ship, and other drills, EPIRB tests, and inspections of emergency equipment and steering gear.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Fire Fighting
Issued 28 July 1998
Resolved
Replace the mount for the portable extinguisher in the forward passenger compartment.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Electrical
Issued 28 July 1998
Resolved
Properly shield bare bulbs in the accomodation spaces.
Condition: Unknown
Due 10 October 1998
Resolved 11 August 1998
Navigation
Issued 28 July 1998
Resolved
Properly attach the single side band radio antenna to the cable.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Electrical
Issued 28 July 1998
Resolved
Place VHF radio on emergency battery.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Documentation
Issued 28 July 1998
Resolved
Captain must obtain 60 minutes of training related to drug and alcohol use.
Condition: Unknown
Due 10 October 1998
Resolved 11 August 1998
Navigation
Issued 28 July 1998
Resolved
Mount emergency broadcast instruction where they are visible from the radio.
Condition: Unknown
Due 10 August 1998
Resolved 11 August 1998
Lifesaving
Issued 29 May 1996
Resolved
Provide 1 adult and 2 child size life preservers. Vessel restricted to no more than 33 adults and 2 children until cleared.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Lifesaving
Issued 29 May 1996
Resolved
Replace Epirb hydrostatic release. Vessel restricted to no more than 20 miles from a harbor of safe refuge until completed.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Lifesaving
Issued 12 June 1995
Resolved
VESSEL WILL CARRY NO MORE THAN (8) PERSONS ONBOARD ON AN OCEANS VOYAGE UNTIL PROOF OF 14 MAN APPROVED PFD WATER LIGHTS IS PROVIDED.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Lifesaving
Issued 1 June 1990
Resolved
PROVIDE SIX (06) ORANGE HAND-HELD FLARES PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Accommodation/Occupational Safety
Issued 1 June 1990
Resolved
ADD ANOTHER COURSE TO LIFELINES, OR NETTING, TO REDUCE OPENING TO TWELVE (12) INCHES.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Accommodation/Occupational Safety
Issued 1 June 1990
Resolved
SERVE ALL WIRE ENDS IN LIFELINES.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Lifesaving
Issued 1 June 1990
Resolved
REPAIR OR REPLACE TWO (02) CHILD AND FIVE (05) ADULT LIFE PRESERVERS PRIOR TO CARRYING MORE THAN TWO (02) CHILDREN UNDER NINETY (90) POUNDS, OR MORE THAN TWENTY-NINE (29) TOTAL PERSONS ON BOARD.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Navigation
Issued 1 June 1990
Resolved
MAKE RADAR OPERATIONAL.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990
Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Lifesaving
Issued 20 May 1987
Resolved
PROVIDE PROPER SECURING ARRANGEMENT FOR BUOYANT APPARRTUS WITH ADEQUITE SIZE WEAK LINK AND 100' PAINTER PRIOR TO PASSENGER SERVICE.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Construction/Loadline
Issued 2 January 1986
Resolved
RENEW DETERIORATED FRAMES AND PLANKS AT TRANSOM AND IN PORT QUARTER. REPAIRS ARE TO BE COMPLETED PRIOR TO PLACING VESSEL BACK IN SERVICE.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986