Records from 1985 to 2008. Most recent: inspection, 5 November 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
5 November 2008
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3358043
12 June 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 957018
6 June 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1242204
9 May 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 907162
20 September 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 931850
15 May 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1225508
1 December 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 928925
23 October 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 893824
23 August 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037682
22 May 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 970853
19 July 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1344033
6 June 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1200846
24 May 1988
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197040
3 August 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1333435
15 May 1987
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1332242
11 June 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1299360
15 December 1985
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301271
8 August 1985
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984116
25 June 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978573
Construction/Loadline
Issued 9 May 1991
Resolved
PROVIDE SISTER FRAME FOR FRACTURED FRAME AFT OF OUTBOARD HATCH, PORT SIDE.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Unknown
Issued 9 May 1991
Resolved
REPLACE PORT SIDE FUEL OIL VENT AND INSTALL 30 X 30 MESH FLAME SCREEN FOR THE SAME.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
INSTALL STAINLESS STEEL FLAME DEFLECTOR SHIELD AND METALLIC DRAIN PLUG FOR THE RACOR FUEL FILTER.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Engineering
Issued 9 May 1991
Resolved
REPLACE FUEL HOSE ON DIESEL ENGINE WITH COAST GUARD APPROVED TYPE.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Construction/Loadline
Issued 23 October 1989
Resolved
PROVIDE VENTILATION FOR BOTH PORT AND STARBOARD PONTOON HULLS THIS SHALL BEDONE TO THE SATISFACTION OF AN ATTENDING C.G. MARINE INSPECTOR AND NO LATERTHAN THE COMPLIANCE DATE.
Condition: Unknown
Due 23 October 1989
Resolved 23 October 1989
Navigation
Issued 22 May 1989
Resolved
PROVIDE AN AUXILIARY STEERING TILLER OPERABLE FROM THE WEATHER DECK.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Fire Fighting
Issued 22 May 1989
Resolved
PROVIDE ONE ADDITIONAL TYPE B-II PORTABLE FIRE EXTINGUISHER IN SERVICABLE CONDITION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Lifesaving
Issued 24 May 1988
Resolved
REPAIR PROTECTIVE COVERING ON BOTH BUOYANT APPARATUS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
STENCIL VESSEL NAME ON BOTH BUOYANT APPARATUS, LIFE-RING BUOY AND LIFE JACKETS.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Lifesaving
Issued 24 May 1988
Resolved
REPAIR PROTECTIVE COVERING ON LIFE-RING BUOY AND DEMONSTRATE OPERATION OF WATER LIGHT.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Fire Fighting
Issued 24 May 1988
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Engineering
Issued 24 May 1988
Resolved
DEMONSTRATE OPERATION OF PROPULSION ENGINE AND PILOTHOUSE CONTROL.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Accommodation/Occupational Safety
Issued 24 May 1988
Resolved
PROVIDE ADDITIONAL VENTILATION FOR ENGINEROOM AND AFT BATTERY STORAGE SPACE. ONE VENT TO BE DUCTED TO NEAR BILGE LEVEL.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988
Resolved
DEMONSTRATE PROPER OPERATION OF MAIN AND AUXILIARY STEERING.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Accommodation/Occupational Safety
Issued 24 May 1988
Resolved
MAKE AVAILABLE FOR INSPECTION THE 4 DRAINS RELOCATED ABOVE WATERLINE MARGIN.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988
Resolved
DEMONSTRATE NAVIGATION LIGHT OPERATION.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Navigation
Issued 24 May 1988
Resolved
DEMONSTRATE VHF RADIO OPERATION.
Condition: Unknown
Due 24 May 1988
Resolved 24 May 1988
Unknown
Issued 25 June 1985
Resolved
PROVIDE EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Unknown
Issued 25 June 1985
Resolved
PROVIDE DRAWING AND ENGINE SPECIFICATIONS FOR NEW ENGINE INSTALLATION.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985
Unknown
Issued 25 June 1985
Resolved
MAKE REPAIRS TO BOTH BUOYANT APPARATUS IN WAY OF SMALL HOLES.
Condition: Unknown
Due 25 June 1985
Resolved 25 June 1985