MAURY USCG vessel records Sign in
← All vessels

SAN CRISTOBAL

SAN CRISTOBAL is a 1982 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 1985, most recently in June 2023, along with 48 deficiencies.

Records from 1985 to 2023. Most recent: inspection, 12 June 2023.

Built
1982
Last inspected
12 June 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBN5033
Flag
UNITED STATES
338330000 (licence lapsed)
Maury page id
psix-54457

Inspections, by type

…with no type recorded6
Years with a record 18 calendar years (1985–2023)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Net Ton
32 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA2995MMSI 338330000 · cancelled · compulsorily equipped · granted 30 November 2000, cancelled 28 May 2002
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 35

12 June 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7713303
15 February 2001 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1437849
11 August 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 821730
8 August 2000 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406772
20 September 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1454712
17 August 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378777
23 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 231794
19 October 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 801543
31 July 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1131080
23 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113197
13 August 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404436
5 August 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1380954
8 August 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085227
30 July 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089380
17 August 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 875668
1 January 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 114840
15 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 109103
22 August 1994 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 868885
3 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 69137
22 September 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1151501
19 August 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1156351
17 January 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 108790
18 August 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253423
20 August 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1248765
25 February 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1228868
21 August 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 907097
31 August 1989 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1351258
23 August 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1038391
23 February 1988 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330656
2 November 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1019229
24 August 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1030247
6 April 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1021784
30 December 1986 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1000307
18 August 1986 Credit Drydock · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1316074
27 August 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988816

Deficiency record · 48

Navigation › Emergency Steering › Communications to Emergency Steering
Issued 15 February 2001 Resolved
Renew and make operational copper steering lines in engine room.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 February 2001 Resolved
Provide evidence of enrollment in random drug testing program.
Condition: Unknown
Due 23 February 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 February 2001 Resolved
Provide operational starboard navigation light.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 15 February 2001 Resolved
Install fixed firefighting system.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Fire Main › Condition
Issued 15 February 2001 Resolved
Renew all inoperative valves in engine room.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 February 2001 Resolved
Provide repair proposal for pitted hole on port exhaust piping at the transverse bulkhead penetration.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 February 2001 Resolved
Cap exposed overgoard fitting in the engine room.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 15 February 2001 Resolved
Repair inoperable emergency fuel shutoff valve in lazarette.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2001 Resolved
Provide approved wiring hold down fittings (no plastic wire ties) throughout vessel.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Electrical › Lighting (service) › Conductor
Issued 15 February 2001 Resolved
Remove all twist-type wire connectors and replace with crimped connections throughout vessel.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline
Issued 15 February 2001 Resolved
Renew inoperative high bilge level alarm in steering compartment.
Condition: Unknown
Due 15 March 2001
Resolved 20 February 2001
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 15 February 2001 Resolved
Replace clear hose for sewage system in cabin.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 February 2001 Resolved
Refasten hanging insulation in engine room.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 February 2001 Resolved
Replace/repair all inoperative guages on the bridge.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Hull › Bottom Plating
Issued 15 February 2001 Resolved
Clean all steel deposits in anchor locker.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Drills/Instruction › Fire
Issued 15 February 2001 Resolved
Conducte fire and man overboard drills in presence of CG inspector.
Condition: Unknown
Due 15 March 2001
Resolved 12 June 2023
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Hull › Bottom Plating
Issued 15 February 2001 Resolved
Crop out and renew all welding fractures along butt of transom and hull bottom.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 15 February 2001 Resolved
Renew light in steering compartment.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering › Compressed Air System (start air) › Piping
Issued 15 February 2001 Resolved
Double clamp all hose fittings in engine room.
Condition: Unknown
Due 15 March 2001
Resolved 6 October 2004
Resolution: 06OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Fire Fighting
Issued 13 August 1997 Resolved
Provide approved brackets for 2 B-II fire extinguishers.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Construction/Loadline
Issued 13 August 1997 Resolved
Renew gasket for steering comparment hatch.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 13 August 1997 Resolved
Provide a vessel specific emergency checklist.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 13 August 1997 Resolved
Provide 1 additional paddle with correct markings for lifefloat.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Engineering
Issued 13 August 1997 Resolved
Properly repair deteriorated hydraulic hose fitting in lazarette compartment.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Engineering
Issued 5 August 1997 Resolved
Replace 2 gate valves for engine exhaust cooling intake and 1 ball valve.
Condition: Unknown
Due 13 August 1997
Resolved 25 August 1997
Lifesaving
Issued 22 August 1994 Resolved
REPAIR L/F AT APPROVED SERVICING FACILITY.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Engineering
Issued 22 August 1994 Resolved
determine and repair fuel leak in lazarette.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Navigation
Issued 22 August 1994 Resolved
replace missing cotter pins in aft steering system.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Electrical
Issued 22 August 1994 Resolved
repair overhead lighting in engineroom space.
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Electrical
Issued 22 August 1994 Resolved
hardwire battery charger
Condition: Unknown
Due 22 August 1994
Resolved 22 August 1994
Lifesaving
Issued 19 August 1993 Resolved
PROVIDE 5 ADDITIONAL ADULT LIFEJACKETS, VESSEL RESTRICTED TO NOT MORE THAN 20 PERSONS ONBOARD UNTIL COMPLIANCE.
Condition: Unknown
Due 19 August 1993
Resolved 19 August 1993
Engineering
Issued 19 August 1993 Resolved
RENEW FUEL TANK FILL HOSE, REPAIR EMERGENCY- SHUT OFF VALVE, AND RENEW GALVANIZED PIPING FROM FUEL TANK TO BULKHEAD PENETRATION.
Condition: Unknown
Due 19 August 1993
Resolved 19 August 1993
Engineering
Issued 23 February 1988 Resolved
INSTALL EXHAUST COOLING ALARM IN ACCORDANCE WITH 46 CFR 182.15-15(B)(5).
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Construction/Loadline
Issued 23 February 1988 Resolved
WELD TWO FRACTURES IN WAY OF DOUBLER PLATE AT PORT SHAFT STRUT.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Construction/Loadline
Issued 23 February 1988 Resolved
WELD FRACTURE AT MSD HAND PUMP OVERBOARD IN #2 COMPARTMENT.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Lifesaving
Issued 24 August 1987 Resolved
MISSING 3 ADULT PFD'S.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Lifesaving
Issued 24 August 1987 Resolved
LABEL STOWAGE FOR CHILD PFD'S.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Lifesaving
Issued 24 August 1987 Resolved
LINES ON RING BUOYS WASTED, RE-NEW.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Lifesaving
Issued 24 August 1987 Resolved
FLOAT-FREE LINK FOR LIFE FLOAT CORRODED AWAY. RE-NEW.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Lifesaving
Issued 24 August 1987 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Lifesaving
Issued 24 August 1987 Resolved
PADDLES FOR LIFE FLOAT NOT MARKED WITH NAME OF VESSEL.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Construction/Loadline
Issued 24 August 1987 Resolved
WATERTIGHT HATCH ON MAIN DECK IN WAY OF GALLEY HAS NO LANYARD TO SECURE HATCH TO VESSEL.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Engineering
Issued 24 August 1987 Resolved
LUBE OIL FILTERS FOR MAIN ENGINES HAVE NO SHIELDS TO PROTECT THEM IN THE EVENT OF A BILGE FIRE.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Electrical
Issued 24 August 1987 Resolved
RE-WIRE IMPROPERLY WIRED SHORE TIE POWER PANEL IN MSD COMPARTMENT FORWARD OF WHEELHOUSE.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Engineering
Issued 24 August 1987 Resolved
RAW WATER HOSES FOR MAIN ENGINE COOLING ARE NOT DOUBLE-CLAMPED AT CONNECTIONS.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Electrical
Issued 24 August 1987 Resolved
BATTERIES HAVE NO HOLDING TRAY. INSTALL TRAY OF LEAD OR FIBERGLAS.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Construction/Loadline
Issued 24 August 1987 Resolved
DOGS FOR MAIN ENGINE WATERTIGHT HATCHES ARE NOT ACCESSIBLE AND NO MEANS IS PROVIDED TO OPERATE DOGS TO MAKE HATCHES WATERTIGHT.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Documentation
Issued 24 August 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.