← All vessels
YUKON JACK
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named YUKON JACK
YUKON JACK is a 1982 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 1984, most recently in May 2025, along with 152 deficiencies and 13 operational controls.
Records from 1984 to 2025. Most recent: inspection, 12 May 2025.
- Built
- 1982
- Last inspected
- 12 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 152 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
649711
WCX9285
54483
Flag
UNITED STATES
—
Maury page id
psix-54483
Inspections, by type
…with no type recorded9
Years with a record
34 calendar years (1984–2025)
The 93 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.5 ft × 12.0 ft × 5.2 ft
Registered tonnagegross 16 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBILL LEE YACHTS,INC · SOQUEL, CA, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Net Ton
16 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 93
12 May 2025
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8133174
25 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099635
17 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7896554
5 March 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7873344
25 October 2022
Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Plan Review "T" Boat · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7583836
8 November 2021
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7345998
3 November 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7343592
31 March 2021
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165247
24 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7145650
17 February 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141825
27 January 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7131408
20 August 2020
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7038637
17 December 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6875319
2 December 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6865667
23 September 2019
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6816996
6 February 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618146
29 January 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6616341
29 January 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6335159
16 December 2016
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6058624
1 November 2016
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6033156
30 December 2015
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5788813
16 November 2015
Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5778026
4 February 2011
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3938067
13 December 2010
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3911105
20 October 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3874535
16 December 2009
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3651249
28 January 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3396874
19 December 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3373970
14 November 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3099844
15 February 2007
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872766
2 February 2007
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2866008
30 October 2006
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2808223
26 January 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2574217
13 December 2005
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2521109
9 February 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2289208
6 January 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2266547
17 December 2004
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2241693
14 January 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1984280
8 December 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1960462
11 September 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1902668
9 June 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1813466
19 December 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1720904
15 November 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705990
5 December 2001
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1436664
5 November 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379618
12 March 2001
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1064519
9 November 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1421750
19 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790655
19 February 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806326
20 November 1998
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805228
10 November 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804966
30 December 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378246
13 February 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1106615
17 January 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377924
7 January 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1380724
13 November 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1183414
3 February 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143619
22 December 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156769
17 November 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1177453
1 February 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852718
20 January 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851170
10 January 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850889
30 December 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140557
28 December 1992
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138526
4 December 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132749
20 November 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827103
10 November 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957485
20 October 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 947031
15 October 1992
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 946728
24 June 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1260000
10 June 1992
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 949725
5 March 1992
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315347
17 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1261130
26 July 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1310979
28 September 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919474
10 September 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 910971
31 August 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240624
19 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921226
17 April 1990
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 903004
27 November 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1211083
14 September 1989
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203777
30 August 1989
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043002
25 July 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1041106
27 July 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1033957
19 January 1988
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324305
15 September 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313081
6 August 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012322
2 October 1986
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006842
9 June 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 993691
4 September 1985
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996376
31 July 1985
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1289001
22 April 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 982366
20 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977582
Deficiency record · 152
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 March 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails.
Lifelines were found loosened during inspection. Tighten all lifelines to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 March 2025
Resolved
Each ship transporting more than six passengers for hire
equipped with a radiotelephone station must carry a
radio operator who holds a marine radio operator permit.
FCC Marine Radio Operator Permit for the Captain was not
available during inspection. Provide a copy. 47 CFR 80.159(e)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 March 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Navigation chart was not up-to-date. Provide updated chart for intended voyage.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2025
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing (for fixed-gas fire extinguishing systems) to the marine inspector. Operator was unable to provide annual service certificate for fixed-gas fire extinguishing system. Provide a copy to the MI. 46 CFR 176.810(b)(1)(iv)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Live dead-end wiring was found in battery compartment. Secure to satisfaction of MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2025
Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: On sailing vessels:(i) Masts, including integration into the ship's structure; and(ii) Rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and
connections of the standing rigging. Sail Rigging plan
was not available during inspection. Provide to MI. 46 CFR 177.202(b)(12)(ii)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 April 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employee. Vessel was unable to provide evidence of chemical testing for required number of crew members on Certificate of Inspection for Limited Coastwise route. 46 CFR 16.201(a)
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 17 April 2024
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). MI observed vessels VHF-DSC radio was not transmitting vessel position. 46 CFR 184.502
47 CFR 80.905(a)(1)
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 April 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician. MI observed that VHF radio on the vessel was not broadcasting all required information. 47 CFR 80.903
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2024
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. MI observed waterlight on ring life buoy is attached to grab line with a splice and no corrosion resistant clip is installed. 46 CFR 180.70(d)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2024
Resolved
...Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. MI observed deteriorated retroreflective material on life jackets. Additionally several snaps on lifejackets are corroded or deteriorating and need servicing/cleaning. 46 CFR 180.71(c)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 April 2024
Resolved
Each buoyant apparatus must be fitted with...a light. MI observed light installed on the buoyant apparatus with drained batteries, required lithium battery replacements were unavailable. 46 CFR 180.175(e)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024
Resolved
A vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not completed annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2024
Resolved
All engines must have at least two means for stopping the engine(s) under any operating conditions. The vessel was unable to operate the engine from the operating station.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 July 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure. Vessel had multiple holes due to missing handles, removed equipment, etc. Repair holes, making vessel watertight, to the satisfaction of the attending marine inspector. 46 CFR 176.802(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2023
Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. Where segregation can be obtained by means of a watertight and/or vapor tight engine box, this will be accepted as a substitute for the required bulkheads. Engine area had large hole where hoses leave space. Make engine area vapor tight to the satisfaction of the marine inspector.
46 CFR 182.35-1
"OLD T"
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 July 2023
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. No alcohol testing
devices were on board. Obtain alcohol testing devices.
46 CFR 185.212
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Hydraulic leak found starboard of engine compartment. Determine cause of leak and repair to the satisfaction of the marine inspector.
46 CFR 176.840
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 July 2023
Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other
than protected waters. The hatch aft of the helm does not have a device to properly secure it. Provide way to secure hatch to the satisfaction of the marine inspector.
46 CFR 185.20-15
"OLD T"
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 February 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not completed worklist items by drydock due date to receive credit for drydock. Complete worklist items to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 December 2022
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fire suppression system has outdated annual service. Have system inspected on the vessel and provide the Marine Inspector a copy of the report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel has had an engine casualty and is unable to get underway. Make repairs to the satisfaction of the attending Marine Inspector prior to the carriage of passengers.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 November 2021
Resolved
A vessel must be operated IAW applicable laws and regulations and in such manner as to afford adequate precaution against hazards that might endanger the vessel and persons being transported. Fire extinguishers and installed fire suppression are beyond service dates. Buoyant apparatus does not have required equipment (Light).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. MI discovered numerous deficiencies with sail rigging. Seize all shackles. Secure all turnbuckles with cotter pins or similar to prevent inadvertent turning. Secure bolts that have back out in gooseneck fitting. Provide details of findings from monthly rigging inspections in PMP. Update PMP to reflect date of last and next mast unstepping (10 Year cycle).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2021
Resolved
The weather deck of a flush deck vessel must be watertight. Boot for baby-stay as it enters the deck has failed and needs replacement.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2021
Resolved
The items in first-aid kit shall be as listed in Table 160.054-4(b). Aspirin in first-aid kit has expired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2021
Resolved
For fixed-gas fire extinguishing systems, the inspections required by Table 176.810(b) of this section. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform required inspections. Fixed fire suppression system has lapsed on annual service. Have system inspected on vessel and provide technician report.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2021
Resolved
At each initial and subsequent inspection for
certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment including inspection of each fire extinguisher. All portable fire extinguisher are due for annual servicing. Have
inspected and provide servicing report to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 November 2021
Resolved
Each buoyant apparatus shall be equipped with a water
light. Water light was missing at time of inspection.
46 CFR 180.15-1(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021
Resolved
The intent of this part is to insure that all vessels be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards of an emergency naturewhich might endanger the vessel and the persons being transpored. Vessel's securing tag line to the back up jib halyard was showing signs of wear and fraying.
46 CFR 185.01-5
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2021
Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel's lifesaving maintenance logs lacked entries and details of actual maintenance performed.
46 CFR 176.810(b)(ii)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021
Resolved
Monthly inspection required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel's firefighting maintenance records lacked entries and details of actual maintenance performed.
46 CFR 185.01-5
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 8 November 2021
Resolved
Unless normal use of the radiotelephone installation demonstrates that the equipment is in proper operating condition, a test communication on a required frequency in the 1605 to 27500kHz band or the 156 to 162MHz band must be made by a qualified operator each day the vessel is navigated. If the equipment is not in proper operating condition, the master must be proptly notified. Vessel's VHF radio transmitted but was unable to receive. Operator identified speaker as the issue and replaced on the spot. Satisfactory test of the VHF radio was completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 November 2021
Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection (COI). COI has expired.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 February 2021
Resolved
46 CFR 180.64 (a) Distress flares and smoke signals.
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry-
Six hand red flare distress signals
Six hand orange smoke distress signals
Flares missing. Replace flares
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2021
Resolved
46 CFR 176.808 (b) Lifesaving
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired. Replace worn out reflective tape on lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 February 2021
Resolved
46 CFR 180.175 (a) Survival Craft Equipment
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Clean Buoyant Apparatus
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 January 2021
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has failed to schedule an annual inspection and is not in compliance with the annual inspection timeline.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2019
Resolved
At each initial and subsequent inspection for certification, the owner must be prepared to conduct tests and have the vessel ready for the following: inspection of each portable fire extinguisher. 01 portable extinguisher shown to be in the red gauge and no longer usable, requires recharging. Replace or service fire extinguisher before getting underway.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 September 2019
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the test required by 46 CFR 147.60 and 147.65. The owner/managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fixed fire fighting lacked current inspection tag/documentation. Provide CG Marine Inspector with current inspection documents for fixed fire fighting before taking passengers.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 September 2019
Resolved
Abandon ship, man overboard, and firefighting drills and training shall be logged or otherwise documented for review by the CG upon request, with the date of the drill and description. Vessel missing current logs for all drills; begin documenting monthly drills IAW CFR requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2019
Resolved
Employers must maintain records of chemical tests and must make these records available to CG upon request. The records shall ID the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required, including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Vessel lacking DAPI documentation for all crew members; provided updated DAPI for all crew members on board to CG inspector.
46 CFR 16.260 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2019
Resolved
A space containing diesel machinery must be fitted with two ducts to furnish natural or powered supply and exhaust ventilations. Engine room space lacking proper ventilations; install proper ventilations for engine space IAW CFR.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 September 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per subpart 177.30-7 of this subchapter. Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered automatically operated lights in strategic locations. These lights shall have an automatic battery charger, shall not be readily portable, and shall have sufficient capacity for 6 hours continuous operation. Vessel lacked any emergency lighting for egress and had only handheld flashlights throughout the vessel. Install required emergency lighting for safe egress.
Updated due date to additional days from annual inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2019
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Unidentified wire on engine not properly terminated. 46 CFR 183.01-15
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 February 2019
Resolved
The number and identification of the items stowed inside must be marked in clearly legible letters and numbers on each container for life jackets. Label port and starboard stowage locations for life jackets.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 February 2019
Resolved
On a vessel of at least 26 ft, a visual and audible alarm must be provided at the operating station. The bilge high level alarm was not labeled; add label for clarity.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 February 2019
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Label location of fire extinguishers since they are located under the table in the main cabin. 46 CFR 181.30-10(b)
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 January 2018
Resolved
Obtain valid Certificate of Documentation.
Engineering › Bilge Water Management System › Pump
Issued 29 January 2018
Resolved
Prove proper operation of fixed hand bilge pump.46 CFR 182.25-10
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 January 2018
Resolved
Provide valid FCC Radio Station Authorization.46 CFR 80.13
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 29 January 2018
Resolved
Remove and replace upper and lower sewage hoses.33 CFR 159
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 29 January 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electric Generation Source (service) › Generator
Issued 29 January 2018
Resolved
Remove dead end wiring associated with generator.46 CFR 183.200
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2018
Resolved
Replace battery for Lifebuoy light.46 CFR 180.70(d)
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2018
Resolved
Replace air supply ducting to engine space with a ridged permanent type. 46 CFR 182.20-45(d)
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 December 2015
Resolved
Move emergency fuel cut off wire to supply valve on fuel tank. Wire is currently to valve between fuel filter and engine.
Communications › Radio Communications › EPIRB
Issued 30 December 2015
Resolved
Install new Hydrostatic release on EPIRB. Place Noaa Registration sticker on EPIRB. Vessel is prohibited from carrying passengers on the High Seas (>3nm from Baseline).
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 20 October 2010
Resolved
Portable space heaters did not have thermal cutouts IAW with 46 CFR 184.210.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 October 2010
Resolved
Life ring buoy lifeline was only 20ft. Operator installed a new 60ft lifeline before we left the vessel.
Construction/Loadline › Structures › Superstructure
Issued 20 October 2010
Resolved
The lower forestay toggle is mushroomed at load point. Replace toggle with new.
Construction/Loadline › Structures › Superstructure
Issued 20 October 2010
Resolved
Complete Rig survey and provide results to OCMI.
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 October 2010
Resolved
E/R hatch cover does not seal as designed. Repair E/R hatch cover to maintain vapor boundary’s IAW 46CFR 177.405.
Communications › Radio Communications › EPIRB
Issued 20 October 2010
Resolved
EPIRB had been sent out for servicing. Provide proof of valid battery and hydrostatic release for EPIRB
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 October 2010
Resolved
Mast light assembly was damaged. Prove proper operation of mast light.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 October 2010
Resolved
Visual alarm for bilge was not operable. Prove proper operation of bilge high level visual alarm.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 October 2010
Resolved
Visual alarm for fire boy did not illuminate. Prove proper operation of fire boy visual extinguished light.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 16 December 2009
Resolved
Repair stbd engine vent piping/ducting.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 16 December 2009
Resolved
Renew port E/R vent ducting or remove and plug opening.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 16 December 2009
Resolved
Cover and seal hole in aft bulkhead of eng/gen space.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 December 2009
Resolved
Provide DAPI paperwork.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 October 2006
Resolved
Post placard stating number and type of lifejackets on forward stowage area.
Fire Fighting › Ventilation Systems › Ducts
Issued 30 October 2006
Resolved
Make repairs to machinery ventilation in way of aft starboard machinery space.
Operations/Management › Drills/Instruction › Fire
Issued 30 October 2006
Resolved
Perform satisfactory firefighting drill.
Electrical › Electric Supply System (service) › Cable
Issued 13 December 2005
Resolved
Secure grounding wire to prevent chaffing and from being entangled in alternator belt.
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 December 2005
Resolved
Renew hot water heater inlet hose to prevent water leakage at connection.
Engineering › Bilge Water Management System › Hose
Issued 13 December 2005
Resolved
Renew aft bilge pump hose in way of lazarette to prevent water leakage at overboard discharge thru hull fitting.
Engineering › Electric Propulsion System › Battery Charging Circuitry
Issued 13 December 2005
Resolved
Tighten main engine alternator belt.
Documentation › Logs/Records › MIS Form
Issued 13 December 2005
Resolved
Provide a copy of the latest MIS report that was submitted to the USCG.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 December 2005
Resolved
Renew 02 child PFD's that are ripped and have a broken clasp, and 01 ripped adult PFD.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 December 2005
Resolved
Tag out circuit that supplies power to the freezer generator.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 February 2005
Resolved
Properly replace or repair the through hull valve for the port aft bilge overboard.
Engineering › Bilge Water Management System › Pump
Issued 9 February 2005
Resolved
Prove proper operation of the manual bilge at the aft operating station.
Electrical › Electric Generation Source (service) › Generator
Issued 9 February 2005
Resolved
Prove proper operation of the generator IAW 46CFR176.25-15 (OLD T). Generator cannot be operated with passengers until this deficiency is cleared.
Communications › Radio Communications › EPIRB
Issued 18 January 2005
Resolved
Provide proof that the EPIRB hydrostatic release unit has not passed its expiration date; otherwise, replace hydrostatic release IAW 46CFR185.740. Vessel limited to not more than 3 NM from shore until corrected.
Communications › Radio Communications › EPIRB
Issued 7 January 2005
Resolved
Provide proof that the EPIRB battery has not passed its expiration date; otherwise, replace battery IAW 46CFR185.726(e). Vessel limited to not more than 3 nautical miles from shore.
Documentation › Logs/Records › Logbook (official)
Issued 7 January 2005
Resolved
Provide a lifesaving inspection log IAW 46CFR185.702(d).
Electrical › Electric Generation Source (service) › Generator
Issued 7 January 2005
Resolved
Prove proper operation of generator IAW 46CFR176.25-15 (OLD T).
Construction/Loadline › Penetrations › Valve Flange
Issued 6 January 2005
Resolved
Replace handles on the following through hull ball valves: (1) Starboard aft generator exhaust, (2) Port aft main diesel engine exhaust, (3) Port aft bilge overboard.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 January 2005
Resolved
Prove proper operation of the bilge high level alarm.
Engineering › Bilge Water Management System › Not Operational
Issued 6 January 2005
Resolved
Prove proper operation of manual overboard bilge pump.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 6 January 2005
Resolved
Repair/replace lifelines on buoyant apparatus and properly re-install on vessel.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 6 January 2005
Resolved
Provide proof of participation in a drug and alcohol program and that crewmembers are enrolled in a random drug testing program.
Stability › Watertight Integrity › General
Issued 17 November 2004
Resolved
Reseal collision bulkhead to hull in way of forepeak, make watertight. Prior to receiving credit for dry dock.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 November 2004
Resolved
Renew watertight hatch securing device in way of forepeak, make watertight. Prior to receiving credit for dry dock.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 November 2004
Resolved
Renew watertight hatch securing devices on both main cabin hatches near aft ladder, and on head hatch, make watertight.
Stability › Watertight Integrity › General
Issued 17 November 2004
Resolved
Reseal forepeak hatch frame to deck making it watertight. Prior to receiving credit for dry dock.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 November 2004
Resolved
Renew two securing devices on escape hatch in way of FWD berthing. Prove watertight integrity.
Engineering › Fuel Oil Service System › Piping
Issued 17 November 2004
Resolved
Renew strainer housing on main engine salt walter thru valve. Prior to receiving credit for dry dock.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 November 2004
Resolved
Provide proof of annual service of fixed fire fighting extinguishing system.
Stability › Watertight Integrity › General
Issued 17 November 2004
Resolved
Repair blisters on hull in way of keel as indentified by attending marine inspector in accordance with NVIC 8-87. Prior to receiving credit for dry dock.
Stability › Watertight Integrity › General
Issued 17 November 2004
Resolved
Repair thru hull openings as identified by attending marine inspector in accordance with NVIC 8-87. Prior to receiving credit for dry dock.
Stability › Watertight Integrity › General
Issued 17 November 2004
Resolved
Repair crack in faring aft of keel. Prior to receiving credit for dry dock.
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 November 2004
Resolved
Prove proper operation of overboard sewage valve on port side head. Prior to receiving credit for dry dock.
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 December 2003
Resolved
Renew expired burn cream and eye dressing in first aid kit. Pictures may be emailed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 December 2003
Resolved
Renew retroreflective tape on 7 adult lifejackets. Pictures may be emailed. LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 December 2002
Resolved
Renew and or repair as new 1 torn lifejacket
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 19 December 2002
Resolved
Meet passageway width requirements of 46 CFR 177.30 "Old T".
Operations/Management › Drug and Alcohol Testing
Issued 19 December 2002
Resolved
Meet requirements of Drug and Alcohol program of 46 CFR part 16. LEGACY COMPONENT DESC: Recordkeeping
Navigation › Piloting/Steering
Issued 19 December 2002
Resolved
Update chart corrections to current Notice to Mariners. LEGACY COMPONENT DESC: Marine Charts
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 December 2002
Resolved
Update First Aid Kit.
Construction/Loadline › Structures › Superstructure
Issued 19 December 2002
Resolved
Repair as new shroud stay on port side in way of mast stays.
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 December 2002
Resolved
Have on board a current copy of the Coast Pilot, Lightlist and navigation charts for the area of operation.
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 December 2002
Resolved
Provide compass light.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 19 December 2002
Resolved
Replace as new starboard engine intake vent hose.
Accommodation/Occupational Safety › Potable Water System
Issued 19 December 2002
Resolved
Replace as new, hotwater heater pressure temperature relief valve (100 psi) LEGACY COMPONENT DESC: Hotwater heater
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 December 2002
Resolved
Provide wire clamp for A/C wires supplying water heater.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 December 2002
Resolved
Provide fixed fire extinguisher instructions near operating station or outside machinery space IAW 46CFR185.612
Operations/Management › Drills/Instruction
Issued 19 December 2002
Resolved
Conduct operational test of vessel while underway and conduct fire and man overboard drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Fire Fighting
Issued 5 November 2001
Resolved
Incorporate engine room power ventilation with fixed firefighting system, ventilation shall automatically shut down upon fixed firefighting system discharge I.A.W. 46 CFR 181.420(a)(3).
Engineering
Issued 5 November 2001
Resolved
Prove proper operation of the remote fuel oil shutoff valve.
Engineering
Issued 5 November 2001
Resolved
Install flame impingement bowl on the main diesel engine fuel oil filter.
Accommodation/Occupational Safety
Issued 7 January 1997
Resolved
REPAIR LEAK IN RAW WATER PUMP IN FREEZER UNIT.
Navigation
Issued 7 January 1997
Resolved
PROVIDE COPY OF OPERATORS RADIO PERMIT.
Fire Fighting
Issued 7 January 1997
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE AT LEAST TWO, TWO AND A HALF GALLON FIRE BUCKETS WITH LANYARD.
Lifesaving
Issued 7 January 1997
Resolved
PROVIDE DOCUMENTION THAT EPIRB MEETS REQUIREMENTS OF A CLASS "A" MANUFACTURED AFTER 1988.
Engineering
Issued 3 February 1995
Resolved
DEMONSTRATE PROPER OPERATION OF THROTTLE CONTROL ON ENGINE DURING U/W TEST.
Documentation
Issued 17 November 1994
Resolved
PROVIDE THE FOLLOWING INFO FOR DRUG TESTING PROGRAM (VIA FAX): (A) DESCRIBEHOW RANDOM TESTING IS CONDUCTED (B) NAME/ADDRESS/PHONE # FOR MRO/COLLECTIONSITE/LAB.
Lifesaving
Issued 17 November 1994
Resolved
PROVIDE REFLECTIVE TAPE FOR 4 ADULT PFD'S. NUMBER OF PASSENGERS LIMITED TO21 UNTIL COMPLETED.
Lifesaving
Issued 17 November 1994
Resolved
PROVIDE 2 LIFELINES (12' LONG, ATTACHED, DOUBLED, TIED) FOR B/A. <NO-SAIL ITEM>.
Lifesaving
Issued 17 November 1994
Resolved
PROVIDE 1 CLIP FOR RING BUOY WATERLIGHT. <NO-SAIL ITEM>.
Electrical
Issued 17 November 1994
Resolved
PROVIDE FREQUENCY METER FOR A/C GENERATOR.
Fire Fighting
Issued 17 November 1994
Resolved
REPLACE 1 B-I FIRE EXTINGUISHER. <NO-SAIL ITEM>.
Engineering
Issued 17 November 1994
Resolved
REPLACE ENGINE/GENERATOR AREA EXHAUST VENTILATION HOSES (2) W/METALLIC HOSE.
Electrical
Issued 20 November 1992
Resolved
PROVE PROPER OPERATION OF VESSEL GENERATOR.
Engineering
Issued 10 September 1990
Resolved
REPLACE STAINLESS STEEL STBD MAIN SHROUD ROD.
Engineering
Issued 31 August 1990
Resolved
INSTALL AND PROVE OPERATION OF MANUAL REMOTE FUEL SHUTOFF LOCATED AS CLOSE AS POSSIBLE TO THE FUEL TANK.
Lifesaving
Issued 31 August 1990
Resolved
PROVIDE 3 ADULT LIFE JACKETS. VESSEL IS RESTRICTED TO 24TOTAL PERSONS.
Accommodation/Occupational Safety
Issued 31 August 1990
Resolved
RESECURE PULPIT DECK FITTINGS AND RESEAL TO PREVENT LEAKAGE.
Construction/Loadline
Issued 17 April 1990
Resolved
REPLACE TWO BROKEN DOGS ON THE WATER TIGHT ESCAPE SCUTTLE ON THE BOW.
Electrical
Issued 17 April 1990
Resolved
REPLACE MISSING LIGHT COVER ON LIGHT ON THE STARBOARD SIDE OUTBOARD OF THE ENGINE COMPARTMENT.
Navigation
Issued 25 July 1989
Resolved
REMOVE EPIRB FROM VESSEL UNTIL SERVICED.
Documentation
Issued 25 July 1989
Resolved
POST EMERGENCY CHECK-OFF LIST.
Lifesaving
Issued 25 July 1989
Resolved
PROVIDE PROPOSAL FOR FLOAT-FREE ARRANGEMENT OF BOUYANT APPARTUS BY 11AUG89.COMPLETE INSTALLATION WITHIN 30 DAYS OF PLAN APPROVAL.
Engineering
Issued 25 July 1989
Resolved
CROP BACK ENGINE BOX MOULDING TO STOP CHAFING IN WAY OF FUEL HOSES AND PULLEY.
Electrical
Issued 25 July 1989
Resolved
PROVIDE COVER FOR FORWARD CABIN LIGHT.
Navigation
Issued 25 July 1989
Resolved
MOUSE STEERING GEAQR SHACKLE FOR STOPPER WIRE.
Deck/Cargo
Issued 25 July 1989
Resolved
PROVIDE SURVEYOR'S REPORT OF ROD STAY DYE CHECK (APPROXIMATELY 24 LOCATIONSAT DECK LEVEL AND ALOFT) PER COINST 16711.8 PROVIDED.
Engineering
Issued 6 August 1987
Resolved
REPLACE ENGINE FUEL HOSES WITH APPVD FLEX FUEL HOSES.
Deck/Cargo
Issued 6 August 1987
Resolved
PERMENATLY REPAIR, OR REPLACE MAST. REPAIR OR REPLACEMENT MUST BE CONDUCTEDIN THE PRESENCE OF A MARINE INSPECTOR.
Engineering
Issued 31 July 1985
Resolved
INSTALL AND PROVE OPERATION OF EMERGENCY FUEL SHUTOFF VALVE.
Lifesaving
Issued 31 July 1985
Resolved
LABEL BUOYANT APPARATUS WITH VESSEL NAME.
Ownership record