MAURY USCG vessel records Sign in
← All vessels

YUKON JACK

YUKON JACK is a 1982 passenger vessel (inspected). The Coast Guard has recorded 93 inspections since 1984, most recently in May 2025, along with 152 deficiencies and 13 operational controls.

Records from 1984 to 2025. Most recent: inspection, 12 May 2025.

Built
1982
Last inspected
12 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCX9285
Flag
UNITED STATES
—
Maury page id
psix-54483

Inspections, by type

…with no type recorded9
Years with a record 34 calendar years (1984–2025)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 12.0 ft × 5.2 ft
Registered tonnagegross 16 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBILL LEE YACHTS,INC · SOQUEL, CA, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Net Ton
16 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 93

12 May 2025 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8133174
25 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099635
17 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7896554
5 March 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7873344
25 October 2022 Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Plan Review "T" Boat · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7583836
8 November 2021 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7345998
3 November 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7343592
31 March 2021 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165247
24 February 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7145650
17 February 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7141825
27 January 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7131408
20 August 2020 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7038637
17 December 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6875319
2 December 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6865667
23 September 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6816996
6 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6618146
29 January 2019 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6616341
29 January 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6335159
16 December 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6058624
1 November 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6033156
30 December 2015 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5788813
16 November 2015 Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5778026
4 February 2011 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3938067
13 December 2010 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3911105
20 October 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3874535
16 December 2009 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3651249
28 January 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3396874
19 December 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3373970
14 November 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3099844
15 February 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872766
2 February 2007 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2866008
30 October 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2808223
26 January 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2574217
13 December 2005 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2521109
9 February 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2289208
6 January 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2266547
17 December 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2241693
14 January 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1984280
8 December 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1960462
11 September 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1902668
9 June 2003 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1813466
19 December 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1720904
15 November 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1705990
5 December 2001 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1436664
5 November 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379618
12 March 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1064519
9 November 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1421750
19 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790655
19 February 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806326
20 November 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805228
10 November 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 804966
30 December 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1378246
13 February 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1106615
17 January 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377924
7 January 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1380724
13 November 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1183414
3 February 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143619
22 December 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156769
17 November 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1177453
1 February 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852718
20 January 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851170
10 January 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850889
30 December 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140557
28 December 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138526
4 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132749
20 November 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827103
10 November 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957485
20 October 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 947031
15 October 1992 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 946728
24 June 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1260000
10 June 1992 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 949725
5 March 1992 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315347
17 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1261130
26 July 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1310979
28 September 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 919474
10 September 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 910971
31 August 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240624
19 July 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921226
17 April 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 903004
27 November 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1211083
14 September 1989 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203777
30 August 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043002
25 July 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1041106
27 July 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1033957
19 January 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324305
15 September 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313081
6 August 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012322
2 October 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006842
9 June 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 993691
4 September 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996376
31 July 1985 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1289001
22 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 982366
20 November 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977582

Deficiency record · 152

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 March 2025 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Lifelines were found loosened during inspection. Tighten all lifelines to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Operator demonstrated that Lifelines can be tightened to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 March 2025 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who holds a marine radio operator permit. FCC Marine Radio Operator Permit for the Captain was not available during inspection. Provide a copy. 47 CFR 80.159(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Received evidence of valid marine operator permit for vessel's captain.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 March 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Navigation chart was not up-to-date. Provide updated chart for intended voyage.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 July 2025
Resolution: Received photo evidence of correct navigation chart.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2025 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing (for fixed-gas fire extinguishing systems) to the marine inspector. Operator was unable to provide annual service certificate for fixed-gas fire extinguishing system. Provide a copy to the MI. 46 CFR 176.810(b)(1)(iv)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Current fixed gas service certificate was shown to MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Live dead-end wiring was found in battery compartment. Secure to satisfaction of MI.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 April 2025
Resolution: Live/dead-end wiring was found secured/removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2025 Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: On sailing vessels:(i) Masts, including integration into the ship's structure; and(ii) Rigging plan showing sail areas and centers of effort as well as the arrangement, dimensions, and connections of the standing rigging. Sail Rigging plan was not available during inspection. Provide to MI. 46 CFR 177.202(b)(12)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 8 July 2025
Resolution: Unable to find original MSC-stamped sail plan. Vessl provided current sail plan.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 April 2024 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employee. Vessel was unable to provide evidence of chemical testing for required number of crew members on Certificate of Inspection for Limited Coastwise route. 46 CFR 16.201(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 6 June 2024
Resolution: Operator showed proof of employee enrollment.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 17 April 2024 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). MI observed vessels VHF-DSC radio was not transmitting vessel position. 46 CFR 184.502 47 CFR 80.905(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 6 June 2024
Resolution: Ooerator repaired radio and had recertified by FCC.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 April 2024 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician. MI observed that VHF radio on the vessel was not broadcasting all required information. 47 CFR 80.903
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 6 June 2024
Resolution: Operator repaired radio and had recertified by FCC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2024 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. MI observed waterlight on ring life buoy is attached to grab line with a splice and no corrosion resistant clip is installed. 46 CFR 180.70(d)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 16 May 2024
Resolution: Received photograph of ring life buoy with removable waterlight correctly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2024 Resolved
...Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. MI observed deteriorated retroreflective material on life jackets. Additionally several snaps on lifejackets are corroded or deteriorating and need servicing/cleaning. 46 CFR 180.71(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 16 May 2024
Resolution: Received photographs of repairs to life jacket snaps.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 April 2024 Resolved
Each buoyant apparatus must be fitted with...a light. MI observed light installed on the buoyant apparatus with drained batteries, required lithium battery replacements were unavailable. 46 CFR 180.175(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 16 May 2024
Resolution: Operator provided photograph of L91 battery install.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024 Resolved
A vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not completed annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Vessel completed annual COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2024 Resolved
All engines must have at least two means for stopping the engine(s) under any operating conditions. The vessel was unable to operate the engine from the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Replaced starter relay switch, engine control reestablished at operating station.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 July 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure. Vessel had multiple holes due to missing handles, removed equipment, etc. Repair holes, making vessel watertight, to the satisfaction of the attending marine inspector. 46 CFR 176.802(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2023
Resolution: Installed equipment and sealed holes to make hull watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2023 Resolved
Except as otherwise provided in this section, machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads of double diagonal wood, marine plywood, steel plate, or equivalent construction. Where segregation can be obtained by means of a watertight and/or vapor tight engine box, this will be accepted as a substitute for the required bulkheads. Engine area had large hole where hoses leave space. Make engine area vapor tight to the satisfaction of the marine inspector. 46 CFR 182.35-1 "OLD T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 7 July 2023
Resolution: Added sealant to make space vapor tight.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 July 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. No alcohol testing devices were on board. Obtain alcohol testing devices. 46 CFR 185.212
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 11 July 2023
Resolution: Obtained alcohol test strips
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Hydraulic leak found starboard of engine compartment. Determine cause of leak and repair to the satisfaction of the marine inspector. 46 CFR 176.840
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 7 July 2023
Resolution: Investigated hydraulic leak. Could not find source of leak, but believe the hydraulic fluid was pooling and spilled when vessel was rocking. Will monitor area and have rebuild kit on board.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 5 July 2023 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. The hatch aft of the helm does not have a device to properly secure it. Provide way to secure hatch to the satisfaction of the marine inspector. 46 CFR 185.20-15 "OLD T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 7 July 2023
Resolution: Added hatch closure
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 February 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not completed worklist items by drydock due date to receive credit for drydock. Complete worklist items to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 April 2023
Resolution: Completed drydock items.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 December 2022 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fire suppression system has outdated annual service. Have system inspected on the vessel and provide the Marine Inspector a copy of the report.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 July 2023
Resolution: Inspection completed and servicing report provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel has had an engine casualty and is unable to get underway. Make repairs to the satisfaction of the attending Marine Inspector prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2023
Resolution: Replaced Engine
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 November 2021 Resolved
A vessel must be operated IAW applicable laws and regulations and in such manner as to afford adequate precaution against hazards that might endanger the vessel and persons being transported. Fire extinguishers and installed fire suppression are beyond service dates. Buoyant apparatus does not have required equipment (Light).
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2021
Resolution: Vessel provided servicing reports and installed light on BA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. MI discovered numerous deficiencies with sail rigging. Seize all shackles. Secure all turnbuckles with cotter pins or similar to prevent inadvertent turning. Secure bolts that have back out in gooseneck fitting. Provide details of findings from monthly rigging inspections in PMP. Update PMP to reflect date of last and next mast unstepping (10 Year cycle).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2021
Resolved 23 November 2021
Resolution: Vessel submitted appropriate PMP and secured all turnbuckles with cotter pins.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2021 Resolved
The weather deck of a flush deck vessel must be watertight. Boot for baby-stay as it enters the deck has failed and needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2021
Resolved 23 November 2021
Resolution: Vessel appropriately covered baby-stay with new boot.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2021 Resolved
The items in first-aid kit shall be as listed in Table 160.054-4(b). Aspirin in first-aid kit has expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2021
Resolved 18 November 2021
Resolution: Vessel replaced all expired medicine.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2021 Resolved
For fixed-gas fire extinguishing systems, the inspections required by Table 176.810(b) of this section. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform required inspections. Fixed fire suppression system has lapsed on annual service. Have system inspected on vessel and provide technician report.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2021
Resolution: Vessel provided servicing reports of all firefighting equipment onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2021 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment including inspection of each fire extinguisher. All portable fire extinguisher are due for annual servicing. Have inspected and provide servicing report to MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 November 2021
Resolution: Vessel provided servicing reports for all firefighting equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 November 2021 Resolved
Each buoyant apparatus shall be equipped with a water light. Water light was missing at time of inspection. 46 CFR 180.15-1(b)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 23 November 2021
Resolved 23 November 2021
Resolution: Waterlight placed onboard and mounted appropriately.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021 Resolved
The intent of this part is to insure that all vessels be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards of an emergency naturewhich might endanger the vessel and the persons being transpored. Vessel's securing tag line to the back up jib halyard was showing signs of wear and fraying. 46 CFR 185.01-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 23 November 2021
Resolution: Back up jib halyard was secured using a metallic shackle.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 November 2021 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel's lifesaving maintenance logs lacked entries and details of actual maintenance performed. 46 CFR 176.810(b)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 23 November 2021
Resolution: Vessel prepared and submitted appropriate lifesaving equipment maintenance log.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021 Resolved
Monthly inspection required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel's firefighting maintenance records lacked entries and details of actual maintenance performed. 46 CFR 185.01-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 23 November 2021
Resolution: Vessel created and submitted appropriate firefighting equipment inspection log.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 8 November 2021 Resolved
Unless normal use of the radiotelephone installation demonstrates that the equipment is in proper operating condition, a test communication on a required frequency in the 1605 to 27500kHz band or the 156 to 162MHz band must be made by a qualified operator each day the vessel is navigated. If the equipment is not in proper operating condition, the master must be proptly notified. Vessel's VHF radio transmitted but was unable to receive. Operator identified speaker as the issue and replaced on the spot. Satisfactory test of the VHF radio was completed.
Action required: 10 - Deficiency Rectified
Due 8 November 2021
Resolved 8 November 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 November 2021 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection (COI). COI has expired.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2021
Resolution: Vessel completed COI inspection and received COI renewal.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 February 2021 Resolved
46 CFR 180.64 (a) Distress flares and smoke signals. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry- Six hand red flare distress signals Six hand orange smoke distress signals Flares missing. Replace flares
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2021
Resolved 6 April 2021
Resolution: Operator sent pictures of new flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2021 Resolved
46 CFR 176.808 (b) Lifesaving Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired. Replace worn out reflective tape on lifejackets
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2021
Resolved 6 April 2021
Resolution: Operator sent pictures of new reflective tape on subject life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 February 2021 Resolved
46 CFR 180.175 (a) Survival Craft Equipment Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Clean Buoyant Apparatus
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2021
Resolved 31 March 2021
Resolution: Operator sent picture of cleaned life saving.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 January 2021 Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has failed to schedule an annual inspection and is not in compliance with the annual inspection timeline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2021
Resolution: Vessel completed required annual inspection per #7141825.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2019 Resolved
At each initial and subsequent inspection for certification, the owner must be prepared to conduct tests and have the vessel ready for the following: inspection of each portable fire extinguisher. 01 portable extinguisher shown to be in the red gauge and no longer usable, requires recharging. Replace or service fire extinguisher before getting underway.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2020
Resolved 21 December 2019
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 September 2019 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the test required by 46 CFR 147.60 and 147.65. The owner/managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fixed fire fighting lacked current inspection tag/documentation. Provide CG Marine Inspector with current inspection documents for fixed fire fighting before taking passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2019
Resolved 9 October 2019
Resolution: Vessel owner sent picture of updated, inspected installed FF.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 September 2019 Resolved
Abandon ship, man overboard, and firefighting drills and training shall be logged or otherwise documented for review by the CG upon request, with the date of the drill and description. Vessel missing current logs for all drills; begin documenting monthly drills IAW CFR requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 17 December 2019
Resolution: Vessel rep supplied required documentation on annual inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2019 Resolved
Employers must maintain records of chemical tests and must make these records available to CG upon request. The records shall ID the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required, including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Vessel lacking DAPI documentation for all crew members; provided updated DAPI for all crew members on board to CG inspector. 46 CFR 16.260 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 17 December 2019
Resolution: Vessel rep supplied required DAPI information on annual audit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2019 Resolved
A space containing diesel machinery must be fitted with two ducts to furnish natural or powered supply and exhaust ventilations. Engine room space lacking proper ventilations; install proper ventilations for engine space IAW CFR.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 21 December 2019
Resolution: Operator added second air duct to machinery space
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 September 2019 Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per subpart 177.30-7 of this subchapter. Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered automatically operated lights in strategic locations. These lights shall have an automatic battery charger, shall not be readily portable, and shall have sufficient capacity for 6 hours continuous operation. Vessel lacked any emergency lighting for egress and had only handheld flashlights throughout the vessel. Install required emergency lighting for safe egress. Updated due date to additional days from annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2020
Resolved 31 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2019 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Unidentified wire on engine not properly terminated. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 1 March 2019
Resolution: Pictures provided to show proper repair of wire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 February 2019 Resolved
The number and identification of the items stowed inside must be marked in clearly legible letters and numbers on each container for life jackets. Label port and starboard stowage locations for life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 11 February 2019
Resolution: Properly labeled port and starboard berths where lifejackets are stored.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 February 2019 Resolved
On a vessel of at least 26 ft, a visual and audible alarm must be provided at the operating station. The bilge high level alarm was not labeled; add label for clarity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 11 February 2019
Resolution: Properly labeled bilge high level alarm.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 February 2019 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. Label location of fire extinguishers since they are located under the table in the main cabin. 46 CFR 181.30-10(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2019
Resolved 11 February 2019
Resolution: Labeled location of the fire extinguishers with p-touch label on the table.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 January 2018 Resolved
Obtain valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 7 August 2018
Resolution: COD dated 8/2/18-8/31/19
Engineering › Bilge Water Management System › Pump
Issued 29 January 2018 Resolved
Prove proper operation of fixed hand bilge pump.46 CFR 182.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2018
Resolved 1 October 2018
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 January 2018 Resolved
Provide valid FCC Radio Station Authorization.46 CFR 80.13
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 February 2018
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 29 January 2018 Resolved
Remove and replace upper and lower sewage hoses.33 CFR 159
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 July 2018
Resolution: Photo provided documenting hose renewal.
Documentation › Certificates/Documents › Letter of Substantial Compliance (DAPI)
Issued 29 January 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 19 July 2018
Electrical › Electric Generation Source (service) › Generator
Issued 29 January 2018 Resolved
Remove dead end wiring associated with generator.46 CFR 183.200
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 July 2018
Resolution: Photo provided detailing removal of dead-end wiring.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2018 Resolved
Replace battery for Lifebuoy light.46 CFR 180.70(d)
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 July 2018
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2018 Resolved
Replace air supply ducting to engine space with a ridged permanent type. 46 CFR 182.20-45(d)
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 1 October 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 December 2015 Resolved
Move emergency fuel cut off wire to supply valve on fuel tank. Wire is currently to valve between fuel filter and engine.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 25 January 2016
Resolution: Remote Shutoff now at Fuel Tank outlet valve.
Communications › Radio Communications › EPIRB
Issued 30 December 2015 Resolved
Install new Hydrostatic release on EPIRB. Place Noaa Registration sticker on EPIRB. Vessel is prohibited from carrying passengers on the High Seas (>3nm from Baseline).
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 25 January 2016
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 20 October 2010 Resolved
Portable space heaters did not have thermal cutouts IAW with 46 CFR 184.210.
Condition: Design Flaw
Due 20 October 2010
Resolved 20 October 2010
Resolution: Vessel rep removed heater from vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 October 2010 Resolved
Life ring buoy lifeline was only 20ft. Operator installed a new 60ft lifeline before we left the vessel.
Condition: Improper Installation
Due 20 October 2010
Resolved 20 October 2010
Construction/Loadline › Structures › Superstructure
Issued 20 October 2010 Resolved
The lower forestay toggle is mushroomed at load point. Replace toggle with new.
Condition: Improper/Lack of Maintenance
Due 20 November 2010
Resolved 23 November 2010
Resolution: Verified new toggle was installed.
Construction/Loadline › Structures › Superstructure
Issued 20 October 2010 Resolved
Complete Rig survey and provide results to OCMI.
Condition: Improper/Lack of Maintenance
Due 31 December 2010
Resolved 10 February 2011
Resolution: O/O conducted rig survey and provided pictures of the mast and all anchoring point of rigging on mast. Pictures are in documents section of this case.
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 October 2010 Resolved
E/R hatch cover does not seal as designed. Repair E/R hatch cover to maintain vapor boundary’s IAW 46CFR 177.405.
Condition: Improper Installation
Due 3 November 2010
Resolved 19 November 2010
Resolution: Verified that E/R Hatch was properly fitted to make an air tight seal.
Communications › Radio Communications › EPIRB
Issued 20 October 2010 Resolved
EPIRB had been sent out for servicing. Provide proof of valid battery and hydrostatic release for EPIRB
Condition: Improper/Lack of Maintenance
Due 3 November 2010
Resolved 19 November 2010
Resolution: Received service report for EPIRB and verified currency of battery and hydrostatic release.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 October 2010 Resolved
Mast light assembly was damaged. Prove proper operation of mast light.
Condition: Damaged By Earlier Event
Due 3 November 2010
Resolved 19 November 2010
Resolution: Vessel installed new light assembly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 October 2010 Resolved
Visual alarm for bilge was not operable. Prove proper operation of bilge high level visual alarm.
Condition: Improper/Lack of Maintenance
Due 3 November 2010
Resolved 20 October 2010
Resolution: Vessel replaced bulb.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 October 2010 Resolved
Visual alarm for fire boy did not illuminate. Prove proper operation of fire boy visual extinguished light.
Condition: Improper/Lack of Maintenance
Due 3 November 2010
Resolved 23 November 2010
Resolution: Vessel replaced with new.
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 16 December 2009 Resolved
Repair stbd engine vent piping/ducting.
Due 16 January 2010
Resolved 15 January 2010
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 16 December 2009 Resolved
Renew port E/R vent ducting or remove and plug opening.
Due 16 January 2010
Resolved 15 January 2010
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 16 December 2009 Resolved
Cover and seal hole in aft bulkhead of eng/gen space.
Due 16 January 2010
Resolved 15 January 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 December 2009 Resolved
Provide DAPI paperwork.
Due 16 January 2010
Resolved 18 December 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 October 2006 Resolved
Post placard stating number and type of lifejackets on forward stowage area.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 7 November 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 30 October 2006 Resolved
Make repairs to machinery ventilation in way of aft starboard machinery space.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2006
Operations/Management › Drills/Instruction › Fire
Issued 30 October 2006 Resolved
Perform satisfactory firefighting drill.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 7 November 2006
Electrical › Electric Supply System (service) › Cable
Issued 13 December 2005 Resolved
Secure grounding wire to prevent chaffing and from being entangled in alternator belt.
Condition: Improper Installation
Due 13 December 2005
Resolved 13 December 2005
Resolution: Corrected on the spot
Accommodation/Occupational Safety › Potable Water System › General
Issued 13 December 2005 Resolved
Renew hot water heater inlet hose to prevent water leakage at connection.
Condition: Improper/Lack of Maintenance
Due 13 January 2006
Resolved 26 January 2006
Engineering › Bilge Water Management System › Hose
Issued 13 December 2005 Resolved
Renew aft bilge pump hose in way of lazarette to prevent water leakage at overboard discharge thru hull fitting.
Condition: Improper/Lack of Maintenance
Due 13 January 2006
Resolved 26 January 2006
Engineering › Electric Propulsion System › Battery Charging Circuitry
Issued 13 December 2005 Resolved
Tighten main engine alternator belt.
Condition: Improper/Lack of Maintenance
Due 13 January 2006
Resolved 26 January 2006
Documentation › Logs/Records › MIS Form
Issued 13 December 2005 Resolved
Provide a copy of the latest MIS report that was submitted to the USCG.
Condition: Unknown
Due 13 January 2006
Resolved 26 January 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 December 2005 Resolved
Renew 02 child PFD's that are ripped and have a broken clasp, and 01 ripped adult PFD.
Condition: Damaged By Earlier Event
Due 13 December 2005
Resolved 13 December 2005
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 December 2005 Resolved
Tag out circuit that supplies power to the freezer generator.
Due 13 December 2005
Resolved 13 December 2005
Resolution: Corrected on the spot.
Construction/Loadline › Penetrations › Pipe Flange
Issued 9 February 2005 Resolved
Properly replace or repair the through hull valve for the port aft bilge overboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2005
Resolved 10 March 2005
Engineering › Bilge Water Management System › Pump
Issued 9 February 2005 Resolved
Prove proper operation of the manual bilge at the aft operating station.
Due 23 February 2005
Resolved 10 March 2005
Electrical › Electric Generation Source (service) › Generator
Issued 9 February 2005 Resolved
Prove proper operation of the generator IAW 46CFR176.25-15 (OLD T). Generator cannot be operated with passengers until this deficiency is cleared.
Due 9 May 2005
Resolved 10 February 2005
Communications › Radio Communications › EPIRB
Issued 18 January 2005 Resolved
Provide proof that the EPIRB hydrostatic release unit has not passed its expiration date; otherwise, replace hydrostatic release IAW 46CFR185.740. Vessel limited to not more than 3 NM from shore until corrected.
Due 7 February 2005
Resolved 9 February 2005
Resolution: Operator had the EPIRB professionally serviced, the batteries and hydrostatic release were both replaced. The batteries expire on FEB 2010, the hydrostatic release expires JAN 2007.
Communications › Radio Communications › EPIRB
Issued 7 January 2005 Resolved
Provide proof that the EPIRB battery has not passed its expiration date; otherwise, replace battery IAW 46CFR185.726(e). Vessel limited to not more than 3 nautical miles from shore.
Due 7 February 2005
Resolved 9 February 2005
Resolution: Operator had the EPIRB professionally serviced, the batteries and hydrostatic release were both replaced. The batteries expire on FEB 2010, the hydrostatic release expires JAN 2007.
Documentation › Logs/Records › Logbook (official)
Issued 7 January 2005 Resolved
Provide a lifesaving inspection log IAW 46CFR185.702(d).
Due 7 February 2005
Resolved 9 February 2005
Electrical › Electric Generation Source (service) › Generator
Issued 7 January 2005 Resolved
Prove proper operation of generator IAW 46CFR176.25-15 (OLD T).
Due 7 February 2005
Resolved 9 February 2005
Resolution: Reissued requirement specifying that the generator cannot be operated with passengers onboard until this deficiency is cleared.
Construction/Loadline › Penetrations › Valve Flange
Issued 6 January 2005 Resolved
Replace handles on the following through hull ball valves: (1) Starboard aft generator exhaust, (2) Port aft main diesel engine exhaust, (3) Port aft bilge overboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Resolution: Operator corrected the problem for the stbd aft generator exhaust valve & the port aft main diesel engine exhaust valve.The port aft bilge overboard repair was unsatisfactory.Issued requirement to replace/repair the port aft bilge ovrbrd thru hull valve.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 January 2005 Resolved
Prove proper operation of the bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Engineering › Bilge Water Management System › Not Operational
Issued 6 January 2005 Resolved
Prove proper operation of manual overboard bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Resolution: Operator proved proper operation of the manual bilge at the cabin operating station; however, the manual bilge was still inop from the aft operating station. Issued requirement to prove proper operation from the aft operating station.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 6 January 2005 Resolved
Repair/replace lifelines on buoyant apparatus and properly re-install on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 6 January 2005 Resolved
Provide proof of participation in a drug and alcohol program and that crewmembers are enrolled in a random drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Stability › Watertight Integrity › General
Issued 17 November 2004 Resolved
Reseal collision bulkhead to hull in way of forepeak, make watertight. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: Cleaned and resealed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 November 2004 Resolved
Renew watertight hatch securing device in way of forepeak, make watertight. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: Removed hatch fairing and re-sealed area. Hatch was watertight. A new fairing piece was ordered from the manufacturer but is not required to maintain watertight integrity in this area.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 November 2004 Resolved
Renew watertight hatch securing devices on both main cabin hatches near aft ladder, and on head hatch, make watertight.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 21 December 2004
Resolution: Renewed
Stability › Watertight Integrity › General
Issued 17 November 2004 Resolved
Reseal forepeak hatch frame to deck making it watertight. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: cleaned and resealed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 November 2004 Resolved
Renew two securing devices on escape hatch in way of FWD berthing. Prove watertight integrity.
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 21 December 2004
Resolution: Replaced.
Engineering › Fuel Oil Service System › Piping
Issued 17 November 2004 Resolved
Renew strainer housing on main engine salt walter thru valve. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Due 21 December 2004
Resolved 21 December 2004
Resolution: Replaced entire strainer assembly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 November 2004 Resolved
Provide proof of annual service of fixed fire fighting extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2004
Resolution: Bottles weighed and inspected by yard.
Stability › Watertight Integrity › General
Issued 17 November 2004 Resolved
Repair blisters on hull in way of keel as indentified by attending marine inspector in accordance with NVIC 8-87. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: Sanded and faired. Satisfactory.
Stability › Watertight Integrity › General
Issued 17 November 2004 Resolved
Repair thru hull openings as identified by attending marine inspector in accordance with NVIC 8-87. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: 5200 sealant removed and repaired IAW NVIC 8-87.
Stability › Watertight Integrity › General
Issued 17 November 2004 Resolved
Repair crack in faring aft of keel. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: Repaired and re-faired.
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 November 2004 Resolved
Prove proper operation of overboard sewage valve on port side head. Prior to receiving credit for dry dock.
Action required: 705 - Other - as specified
Resolved 21 December 2004
Resolution: Modified handle to ball valve to allow for proper closing of the valve.
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 December 2003 Resolved
Renew expired burn cream and eye dressing in first aid kit. Pictures may be emailed.
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 14 January 2004
Resolution: Pictures emailed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 December 2003 Resolved
Renew retroreflective tape on 7 adult lifejackets. Pictures may be emailed. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 8 January 2004
Resolved 14 January 2004
Resolution: Pictures emailed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 December 2002 Resolved
Renew and or repair as new 1 torn lifejacket
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 December 2002
Resolved 19 December 2002
Resolution: Replaced during inspection.
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 19 December 2002 Resolved
Meet passageway width requirements of 46 CFR 177.30 "Old T".
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 8 December 2003
Resolution: Owner accepted resolution spelled out in MSO SF letter #113-03.
Operations/Management › Drug and Alcohol Testing
Issued 19 December 2002 Resolved
Meet requirements of Drug and Alcohol program of 46 CFR part 16. LEGACY COMPONENT DESC: Recordkeeping
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Met requirement.
Navigation › Piloting/Steering
Issued 19 December 2002 Resolved
Update chart corrections to current Notice to Mariners. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Updated charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 December 2002 Resolved
Update First Aid Kit.
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Updated kit.
Construction/Loadline › Structures › Superstructure
Issued 19 December 2002 Resolved
Repair as new shroud stay on port side in way of mast stays.
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Repaired shroud.
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 December 2002 Resolved
Have on board a current copy of the Coast Pilot, Lightlist and navigation charts for the area of operation.
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Provided current copies.
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 December 2002 Resolved
Provide compass light.
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Provided light.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 19 December 2002 Resolved
Replace as new starboard engine intake vent hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Replaced vent hose.
Accommodation/Occupational Safety › Potable Water System
Issued 19 December 2002 Resolved
Replace as new, hotwater heater pressure temperature relief valve (100 psi) LEGACY COMPONENT DESC: Hotwater heater
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Replaced valve.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 December 2002 Resolved
Provide wire clamp for A/C wires supplying water heater.
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Provided wire clamp.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 December 2002 Resolved
Provide fixed fire extinguisher instructions near operating station or outside machinery space IAW 46CFR185.612
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Provided instructions.
Operations/Management › Drills/Instruction
Issued 19 December 2002 Resolved
Conduct operational test of vessel while underway and conduct fire and man overboard drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 30 January 2003
Resolution: Conducted drills.
Fire Fighting
Issued 5 November 2001 Resolved
Incorporate engine room power ventilation with fixed firefighting system, ventilation shall automatically shut down upon fixed firefighting system discharge I.A.W. 46 CFR 181.420(a)(3).
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Engineering
Issued 5 November 2001 Resolved
Prove proper operation of the remote fuel oil shutoff valve.
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Engineering
Issued 5 November 2001 Resolved
Install flame impingement bowl on the main diesel engine fuel oil filter.
Condition: Unknown
Due 5 November 2001
Resolved 5 November 2001
Accommodation/Occupational Safety
Issued 7 January 1997 Resolved
REPAIR LEAK IN RAW WATER PUMP IN FREEZER UNIT.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Navigation
Issued 7 January 1997 Resolved
PROVIDE COPY OF OPERATORS RADIO PERMIT.
Condition: Unknown
Due 7 February 1997
Resolved 8 January 1997
Fire Fighting
Issued 7 January 1997 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE AT LEAST TWO, TWO AND A HALF GALLON FIRE BUCKETS WITH LANYARD.
Condition: Unknown
Due 7 February 1997
Resolved 21 January 1997
Lifesaving
Issued 7 January 1997 Resolved
PROVIDE DOCUMENTION THAT EPIRB MEETS REQUIREMENTS OF A CLASS "A" MANUFACTURED AFTER 1988.
Condition: Unknown
Due 7 February 1997
Resolved 21 January 1997
Engineering
Issued 3 February 1995 Resolved
DEMONSTRATE PROPER OPERATION OF THROTTLE CONTROL ON ENGINE DURING U/W TEST.
Condition: Unknown
Due 3 February 1995
Resolved 3 February 1995
Documentation
Issued 17 November 1994 Resolved
PROVIDE THE FOLLOWING INFO FOR DRUG TESTING PROGRAM (VIA FAX): (A) DESCRIBEHOW RANDOM TESTING IS CONDUCTED (B) NAME/ADDRESS/PHONE # FOR MRO/COLLECTIONSITE/LAB.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Lifesaving
Issued 17 November 1994 Resolved
PROVIDE REFLECTIVE TAPE FOR 4 ADULT PFD'S. NUMBER OF PASSENGERS LIMITED TO21 UNTIL COMPLETED.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Lifesaving
Issued 17 November 1994 Resolved
PROVIDE 2 LIFELINES (12' LONG, ATTACHED, DOUBLED, TIED) FOR B/A. <NO-SAIL ITEM>.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Lifesaving
Issued 17 November 1994 Resolved
PROVIDE 1 CLIP FOR RING BUOY WATERLIGHT. <NO-SAIL ITEM>.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Electrical
Issued 17 November 1994 Resolved
PROVIDE FREQUENCY METER FOR A/C GENERATOR.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Fire Fighting
Issued 17 November 1994 Resolved
REPLACE 1 B-I FIRE EXTINGUISHER. <NO-SAIL ITEM>.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Engineering
Issued 17 November 1994 Resolved
REPLACE ENGINE/GENERATOR AREA EXHAUST VENTILATION HOSES (2) W/METALLIC HOSE.
Condition: Unknown
Due 17 November 1994
Resolved 17 November 1994
Electrical
Issued 20 November 1992 Resolved
PROVE PROPER OPERATION OF VESSEL GENERATOR.
Condition: Unknown
Due 5 December 1992
Resolved 7 December 1992
Engineering
Issued 10 September 1990 Resolved
REPLACE STAINLESS STEEL STBD MAIN SHROUD ROD.
Condition: Unknown
Due 10 September 1990
Resolved 10 September 1990
Engineering
Issued 31 August 1990 Resolved
INSTALL AND PROVE OPERATION OF MANUAL REMOTE FUEL SHUTOFF LOCATED AS CLOSE AS POSSIBLE TO THE FUEL TANK.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Lifesaving
Issued 31 August 1990 Resolved
PROVIDE 3 ADULT LIFE JACKETS. VESSEL IS RESTRICTED TO 24TOTAL PERSONS.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Accommodation/Occupational Safety
Issued 31 August 1990 Resolved
RESECURE PULPIT DECK FITTINGS AND RESEAL TO PREVENT LEAKAGE.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Construction/Loadline
Issued 17 April 1990 Resolved
REPLACE TWO BROKEN DOGS ON THE WATER TIGHT ESCAPE SCUTTLE ON THE BOW.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Electrical
Issued 17 April 1990 Resolved
REPLACE MISSING LIGHT COVER ON LIGHT ON THE STARBOARD SIDE OUTBOARD OF THE ENGINE COMPARTMENT.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Navigation
Issued 25 July 1989 Resolved
REMOVE EPIRB FROM VESSEL UNTIL SERVICED.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Documentation
Issued 25 July 1989 Resolved
POST EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Lifesaving
Issued 25 July 1989 Resolved
PROVIDE PROPOSAL FOR FLOAT-FREE ARRANGEMENT OF BOUYANT APPARTUS BY 11AUG89.COMPLETE INSTALLATION WITHIN 30 DAYS OF PLAN APPROVAL.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Engineering
Issued 25 July 1989 Resolved
CROP BACK ENGINE BOX MOULDING TO STOP CHAFING IN WAY OF FUEL HOSES AND PULLEY.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Electrical
Issued 25 July 1989 Resolved
PROVIDE COVER FOR FORWARD CABIN LIGHT.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Navigation
Issued 25 July 1989 Resolved
MOUSE STEERING GEAQR SHACKLE FOR STOPPER WIRE.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Deck/Cargo
Issued 25 July 1989 Resolved
PROVIDE SURVEYOR'S REPORT OF ROD STAY DYE CHECK (APPROXIMATELY 24 LOCATIONSAT DECK LEVEL AND ALOFT) PER COINST 16711.8 PROVIDED.
Condition: Unknown
Due 25 July 1989
Resolved 25 July 1989
Engineering
Issued 6 August 1987 Resolved
REPLACE ENGINE FUEL HOSES WITH APPVD FLEX FUEL HOSES.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Deck/Cargo
Issued 6 August 1987 Resolved
PERMENATLY REPAIR, OR REPLACE MAST. REPAIR OR REPLACEMENT MUST BE CONDUCTEDIN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Engineering
Issued 31 July 1985 Resolved
INSTALL AND PROVE OPERATION OF EMERGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985
Lifesaving
Issued 31 July 1985 Resolved
LABEL BUOYANT APPARATUS WITH VESSEL NAME.
Condition: Unknown
Due 31 July 1985
Resolved 31 July 1985