CAPE ANN DIVER II
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Northeast District (CGD-NE) · Other hulls named CAPE ANN DIVER II
CAPE ANN DIVER II is a 1982 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1985, most recently in October 2025, along with 75 deficiencies — 5 with no resolution recorded — and 6 casualty investigations between 2003 and 2023.
Records from 1985 to 2025. Most recent: inspection, 23 October 2025.
- Built
- 1982
- Last inspected
- 23 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 75 recorded · 5 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 6 investigations · 2003–2023
Identity
650868
WDJ9090
54485
Flag
UNITED STATES
367071340, 368176130
Maury page id
psix-54485
Inspections, by type
…with no type recorded13
Years with a record
38 calendar years (1985–2025)
The 88 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)44.3 ft × 15.1 ft × 5.8 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE WORK BOAT DIVISION · HAYES, VA, UNITED STATES · built 1982
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGLOUCESTER, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 21 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Net Ton
27 - Simplified, Gross Ton
27 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ4977MMSI 368176130 · active · compulsorily equipped · granted 12 July 2025, expires 12 July 2035
WDL9121MMSI 368176130 · cancelled · compulsorily equipped · granted 5 January 2021, cancelled 7 July 2025
WDJ9090MMSI 367071340 · active · compulsorily equipped · granted 9 February 2018, expires 9 February 2028
WDC7432MMSI 367071340 · cancelled · compulsorily equipped · granted 8 October 2015, cancelled 30 January 2018
WCR3534MMSI not assigned · expired · compulsorily equipped · granted 4 May 1995, cancelled 9 July 2005
WRB4147MMSI not assigned · expired · compulsorily equipped · granted 15 February 1994, cancelled 30 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 88
23 October 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8254017
8 July 2025
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8179299
8 May 2025
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8131751
7 January 2025
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8059524
14 May 2024
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7911459
5 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7863504
29 November 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7781184
13 May 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7687488
13 May 2023
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7687721
13 May 2023
Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 7691322
10 November 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7555187
21 July 2022
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7506314
25 March 2022
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7363250
2 November 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7341169
26 October 2020
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7084092
12 March 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6923913
6 November 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6849707
23 June 2019
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6723210
24 October 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6567816
30 May 2018
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6429903
26 May 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6424979
6 March 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6363764
30 October 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6298079
24 October 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6029067
30 March 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5843679
26 October 2015
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5746079
27 October 2014
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5012942
25 March 2014
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4823248
8 December 2011
Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4204097
25 October 2010
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3875326
29 March 2010
Drydock Exam · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3705277
28 October 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3352761
6 March 2008
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3159596
2 November 2007
Re-Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3091827
26 October 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2808640
1 September 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2770627
1 September 2006
Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 2771350
28 March 2006
Hull Examination · Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2585760
21 October 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2519171
27 October 2004
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2229163
26 March 2004
Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2031601
29 October 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1938132
10 February 2003
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1742416
30 October 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1731267
27 March 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1599562
31 October 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1393799
15 March 2001
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1060128
18 October 2000
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1403244
3 July 2000
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1050428
23 March 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1397378
5 November 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361200
27 October 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1381711
25 March 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 779461
28 October 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804070
24 March 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 787173
15 October 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 779163
6 November 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860392
30 October 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1167252
2 April 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1078182
26 March 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1077691
25 October 1995
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 883632
22 May 1995
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 874803
13 April 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1159062
24 October 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863439
14 March 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1166124
29 November 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158612
4 March 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 835174
25 November 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133010
3 March 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958868
30 October 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943058
6 March 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 910079
2 November 1990
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221415
1 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930058
19 March 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 904411
2 November 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 912273
8 May 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198401
9 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195586
9 November 1988
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196907
18 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337938
23 October 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018107
21 October 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1323407
25 March 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326480
2 December 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328853
7 November 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014966
17 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304561
7 November 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985361
26 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 981364
19 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289660
Deficiency record · 75
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2025
No resolution recorded
Ring life bouys grab line and life line were severely weathered.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 October 2025
No resolution recorded
Life float grab lines and painter as they were severely weathered.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 October 2025
No resolution recorded
Vessel had loose deck rails on port and stbd side cockpit deck.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 October 2025
No resolution recorded
Vessel had expired flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 October 2025
No resolution recorded
essels installed service generator is inoperable and generator is in poor condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 January 2025
Resolved
RAILS SHALL BE INSTALLED NEAR THE PERIPHERY OF ALL WEATHERDECKS ACCESSIBLE TO THE PASSENGERS AND CREWS.
FORWARD STARBOARD RAILING WAS FOUND VERY LOOSE AND EASILY MOVED BEYOND ITS DESIGNED FIXED POSITION.
cite: 46 CFR 177.35-1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 January 2025
Resolved
THE POWER FIRE PUMP SHALL BE SELFPRIMING AND OF SUCH SIZE AS TO DISCHARGE AN EFFECTIVE STREAM FROM A HOSE CONNECTED TO THE HIGHEST OUTLET. INSTALLED FIRE PUMP AND ASSOCIATED EQUIPMENT COULD NOT BE TESTED DUE TO LOW AMBIENT TEMPERATURE HAVING FROZEN WATER IN THE SYSTEM. TO BE CONDUCTED PRIOR TO CARRYING PASSENGERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
46 CFR 176.810(a)(3)
46 CFR 181.10-1 (b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 January 2025
Resolved
ALL VESSELS SHALL BE FITTED WITH A SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATERTIGHT COMPARTMENT UNDER ALL CONDITIONS. INSTALLED BILGE PUMPING SYSTEM COULD NOT BE TESTED DUE TO LOW AMBIENT TEMPERATURE. TO BE CONDUCTED PRIOR TO CARRYING PASSENGERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
46 CFR 176.804(h)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 November 2023
Resolved
Each vessel operating beyond the high seas must have onboard a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. At the time of inspection, the hydrostatic release on the vessel's EPIRB was found to be expired. Vessel is restricted to within 3 nautical miles until the vessel is fitted with a functional hydrostatic release. 46CFR180.64
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 May 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel suffered a mechanical failure to its transmission while underway. Affect proper repairs and conduct sea trials to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2019
Resolved
All vessels shall be provided with a satisfactory
arrangement for draining any watertight compartment
other than small buoyancy compartments, under all
practical conditions. Found crack in bilge system
piping at overboard discharge inside engine
compartment. Renew section of piping with materials
in kind. 46 CFR 182.25-1
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 November 2019
Resolved
The float-free link required by §180.130(a)(1) must be
of proper strength for the size of the life float or
buoyant apparatus as indicated on its identification
tag. Float free link identification tag does not indicate
breaking strength or size. Provide a float free link with
with complete identification tag. 46 CFR 180.137(b)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 November 2019
Resolved
Life floats and buoyant apparatus When stowed in
tiers, the separate units must be kept apart by
spacers. No spacers separating life floats. Provide
spaces to separate life floats. 46 CFR 180.137(f)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 November 2019
Resolved
Lifeline and pendants. The lifeline and pendants must
be as furnished by the manufacturer with the approved
life float or buoyant apparatus. Replacement lifelines
and pendants must meet the requirements in Subpart
160.010 of this chapter. Life lines on both life floats
found in unserviceable conditions. Replace all worn
lifelines on both life floats with approved materials.
46 CFR 180.70(d)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2019
Resolved
Each ring life buoy with a floating waterlight must have
a lanyard of at least 910 millimeters (3 feet) in length,
but not more than 1,830 millimeters (6 feet), securing
the waterlight around the body of the ring life. When
attached around the body of the forward port life right,
the water light lanyard is not of adequate length.
Provide lanyard of adequate length. 46 CFR 180.70(d)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2019
Resolved
This part is intended to provide a minimum standard of
regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from
fire caused by and/or originating in electrical
equipment, and reasonably safe from electrical shock
of personnel. Electrical connections found in the
forward starboard engine compartment made with
exposed wire nuts. Make permanent electrical
connections and properly insulate them from contact
with the hull or personnel. 46 CFR 183.01-5
Lifesaving › Lifebuoys › Serviceable
Issued 30 October 2017
Resolved
Replace worn ring buoy on port side. Ensure light and line are attached to serviceable ring buoy.
Electrical › Electric Generation Source (service) › Generator
Issued 26 October 2015
Resolved
Hertze/cyc gauge for generator not working, have gauge repiared by 09NOV15.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 October 2014
Resolved
Only 32 adult and 0 child size PFD's onboard that are in serviceable condition. Vessel is restricted to 32 max persons onboard and cannot carry any person under 90lbs.
Lifesaving › Lifefloat › Markings
Issued 27 October 2014
Resolved
Life floats need to have capacity marked, along with one paddle that is not marked. Retro reflective tape needs to be replaced/added to life float.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 October 2014
Resolved
Proper publications are not onboard. Vessel needs Coast Pilot, CG Light and Tide Tables.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 October 2014
Resolved
Lifejacket stowage needs to be marked with size and amount.
Lifesaving › Lifebuoys › Serviceable
Issued 25 October 2010
Resolved
Replace the starboard side life ring.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 25 October 2010
Resolved
Provide valid radio telephone cert.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 October 2010
Resolved
Replace the outdated the first aid kit.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 October 2010
Resolved
Provide a valid copy of the COD.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 25 October 2010
Resolved
Fixed fire extinguishers bottle is out of hydro date. Hydro test or replace the bottle.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 October 2008
Resolved
Service one B-I extingusher on bridge
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 October 2008
Resolved
Repair bilge alarm indicatot light on bridge console
Lifesaving › Lifebuoys › Serviceable
Issued 28 October 2008
Resolved
Renew Lifering
Lifesaving › Lifefloat › Paddle
Issued 28 October 2008
Resolved
Renew four paddles
Lifesaving › Lifefloat › Serviceable
Issued 28 October 2008
Resolved
Repair areas identified with approved materials and approved procedures
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 November 2007
Resolved
Fire extinguisher servicing dates expired.
Communications › Radio Communications › EPIRB
Issued 2 November 2007
Resolved
Epirb battery beyond service date, expired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 October 2005
Resolved
Service portable fire extinguishers.
Engineering › Bilge Water Management System › Pump
Issued 21 October 2005
Resolved
Renew mechanical bilge pump.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 October 2005
Resolved
Provide placards labeling the emergency fuel shut-offs.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 October 2004
Resolved
VESSEL IS LIMITED TO 28 PASSENGERS UNTIL 39 TYPE I LIFE JACKETS ARE PROVIDED
Communications › Radio Communications › EPIRB
Issued 27 October 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Communications › Radio Communications › VHF Radiotelephone
Issued 27 October 2004
Resolved
REPLACE EMERGENCY BROADCAST PLACARD.
Electrical › Electric Supply System (service)
Issued 26 March 2004
Resolved
Secure battery covers on the port side in the engine room. LEGACY COMPONENT DESC: Battery Installation
Accommodation/Occupational Safety › Occupational Safety
Issued 26 March 2004
Resolved
Tighten all stanchons to the bulwark on vessel. LEGACY COMPONENT DESC: Deck Rail
Accommodation/Occupational Safety › Occupational Safety
Issued 26 March 2004
Resolved
Weld fracture in the hand rail, port side, aft. LEGACY COMPONENT DESC: Deck Rail
Documentation
Issued 31 October 2001
Resolved
Post the drug and alcohol policy and hotline numbers
Fire Fighting
Issued 31 October 2001
Resolved
Hydrostatic test the B-II extinguisher in the accommodation space (replaced)
Electrical
Issued 31 October 2001
Resolved
Provide two portable flashlights
Fire Fighting
Issued 31 October 2001
Resolved
Weigh the fixed and portable fire extinguishers
Lifesaving
Issued 18 October 2000
Resolved
Properly attach buoyant apparatus lanyard to weak link.
Fire Fighting
Issued 27 October 1999
Resolved
PROPERLY LOG INSTRUCTION AND DUTY TRAINING GIVEN TO CREW MENBERS IAW 46CFR 185.420.(a)_x001C_ PROPERLY LOG MONTHLY EPIRB TESTS IAW 46CFR 185.728.
Construction/Loadline
Issued 27 October 1999
Resolved
PROPERLY SECURE BROKEN BONDING WIRE FOR THE SEA VALVE PORT SIDE FORWARD.
Lifesaving
Issued 27 October 1999
Resolved
RETRO REFLECTIVE TAPE WEATHERED ON APPROXIMATELY 12 ADULT LIFE PRESERVERS. PROPERLY MARK ALL LIFE PRESERVERS WITH RETRO REFLECTIVE TAPE.
Documentation
Issued 27 October 1999
Resolved
RADIO SAFETY TELEPHONY CERTIFICATE EXPIRED. RENEW SAFETY CERTIFICATE PRIORTO OPERATING MORE THAN 1000 FEET FROM SHORE.
Fire Fighting
Issued 27 October 1999
Resolved
PROVIDE MEANS OF CLOSING THE VENTILATION TO THE SPACES PROVIDED WITH A FIXED GAS FIRE SYSTEM. IAW 46CFR 182.465(h).
Electrical
Issued 30 October 1996
Resolved
PROVIDE A SUITABLE COVER FOR THE BATTERIES LOCATED IN THE ENGINE ROOM.
Electrical
Issued 30 October 1996
Resolved
DOUBLE CLAMP THE GENSET COOLING WATER INTAKE HOSE FROM THE SEA VALVE TO THESTRAINER.
Engineering
Issued 30 October 1996
Resolved
RENEW THE EXHAUST COOLING WATER HOSE.
Electrical
Issued 30 October 1996
Resolved
PROVE PROPER OPERATION OF THE GENSET FREQUENCY METER.
Construction/Loadline
Issued 26 March 1996
Resolved
PRIOR TO PLACING VESSEL IN SERVICE OR CARRYING PASSENGERS, RENEW THA MAIN CABIN BILGE SUCTION LINE WHERE HOLED.
Navigation
Issued 25 October 1995
Resolved
PROVIDE PIN FOR RUDDER ASSEMBLY ALLOWING PROPER OPERATION OF EMERGENCY TILLER.
Fire Fighting
Issued 25 October 1995
Resolved
SERVICE FIXED HALON SYSTEM PROVING PROPER OPERATION OF ALARMS, PRIOR TO VESSEL OPERATION.
Documentation
Issued 25 October 1995
Resolved
PROVIDE CURRENT FCC RADIOTELEPHONY CERTIFICATE.
Lifesaving
Issued 2 November 1990
Resolved
PROVIDE BUOYANT APPARATUS OF LIFEBOAT THIS IS IN SAT. CONDITION.
Navigation
Issued 2 November 1990
Resolved
PROVIDED 2 ADDITIONAL RED FLARES SIGNAL.
Lifesaving
Issued 9 November 1988
Resolved
RENEW SEA PAINTER ON LIFE FLOAT.
Lifesaving
Issued 9 November 1988
Resolved
RENEW LIFE LINE ON RING BUOY.
Engineering
Issued 9 November 1988
Resolved
RE MARK EMERGENCY FUEL SHUT OFF VALVE.
Electrical
Issued 9 November 1988
Resolved
REMOVE EXTRA BATTERY FROM BILGE AND INSTALL A PROPER LINED BATTERY BOX.
Electrical
Issued 9 November 1988
Resolved
REPAIR PORT SIDE LIGHT AND MAST HEAD LIGHT.
Lifesaving
Issued 9 November 1988
Resolved
PAINT AND RE MARK LIFE FLOAT.
Accommodation/Occupational Safety
Issued 21 October 1987
Resolved
REMOVE DIRECT DISCHARGE/BY-PASS LINE FROM INSTALLED MSD.
Navigation
Issued 21 October 1987
Resolved
PROVIDE CURRENT CHARTS, TIDE TABLES, AND TIDAL CURRENT TABLES.
Construction/Loadline
Issued 7 November 1986
Resolved
PROVIDE CAPTIVE CHAINS FOR ALL THREE MAIN DECK HATCHES. TO BE CORRECTED PRIOR TO CARRYING PASSENGERS OR NO LATER THAN 1 DEC 86.
Fire Fighting
Issued 7 November 1986
Resolved
PROVIDE PROOF OF SERVICING FOR FIXED HALON SYSTEM IN MACHINERY SPACE, INCLUDING PROOF OF OPERATION OF ACTIVATING DEVICE. TO BE CORRECTED PRIOR TO CARRYING PASENGERS OR NO LATER THAN 1 DECEMBER 1986.
Lifesaving
Issued 7 November 1986
Resolved
RENEW LIFELINES AND GRABLING ON LIFEFLOAT. TO BE CORRECTED PRIOR TO CARRYING PASSENGERS OR NO LATER THAN 1 DECEMBER 1986.
Engineering
Issued 7 November 1986
Resolved
PROVIDE SUPPORT TO COOLING WATER OVERFLOW PIPING. TO BE CORRECTED PRIOR TOCARRYING PASSENGERS OR NO LATER THAN 1 DECEMBER 1986.
Casualty record · 6
10 February 2003Significant Marine Casualty · role: Moored/Anchored in Vicinity of Primary Subject · 1 dead · activity 1742416
1 September 2006Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 2770627
21 April 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4576274
26 May 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6424979
23 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6723210
13 May 2023Routine · role: Involved in a Marine Casualty · activity 7687488
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.