Records from 1984 to 2025. Most recent: inspection, 19 August 2025.
Inspection history · 56
19 August 2025
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8213493
13 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8001236
12 March 2024
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7877911
24 July 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7703455
8 September 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7554436
2 November 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7344161
7 June 2021
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7209061
19 January 2021
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7126640
3 December 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7116643
19 November 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6862237
29 April 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6672605
3 December 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6590904
23 October 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6293522
1 November 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6032616
28 July 2015
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5198590
27 December 2011
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4215649
27 October 2008
Simplified Stability Test · Internal Structural Exam · Examination of Repairs · Plan Review "T" Boat · COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3352955
24 October 2006
Hull Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2807017
18 June 2002
Hull Examination · Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1492884
24 April 2001
Re-Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1403328
27 March 2000
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1450430
10 May 1999
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 804750
19 April 1999
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1365218
19 March 1999
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1365125
8 August 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 117619
21 July 1998
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 795315
10 May 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 792468
27 April 1998
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1125121
2 April 1998
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1454535
25 April 1997
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1095643
2 April 1997
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1392648
15 February 1996
Deficiency Check · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1435727
13 February 1995
Re-Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1394248
25 March 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1166257
16 February 1994
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1417611
9 March 1993
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1438027
10 April 1992
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 957697
6 April 1992
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1259551
1 August 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 935865
1 August 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 936235
8 February 1991
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1214849
16 November 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1229851
12 March 1990
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 921123
20 February 1990
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1233774
24 February 1989
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1043274
17 November 1988
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1204056
25 February 1988
COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1328380
15 December 1987
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1004332
3 December 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1027510
18 June 1987
Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1006696
5 March 1987
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1014376
9 February 1987
Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1319211
19 February 1986
Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1296554
9 December 1985
Credit Drydock
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1299997
19 February 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1284270
5 December 1984
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1284814
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2024
Resolved
Lifejacket storage locker had gear that did not belong in there and were prohibitting access to lifejackets
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 13 September 2024
Resolution: Gear was moved
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2024
Resolved
Waterlight was not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 17 September 2024
Resolution: All sat
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 September 2024
Resolved
Gauge on fire pump discharge was inop
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 17 September 2024
Resolution: Gauge was replaced
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 July 2023
Resolved
Public announcement system on board not working.
Required working public announcement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2023
Resolved 8 August 2023
Resolution: System working onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 July 2023
Resolved
Engine room fixed and portable extinguishers expired
service. Provide evidence of servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2023
Resolved 8 August 2023
Resolution: All has been serviced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 July 2023
Resolved
Engine room and steering compartment missing device to
secure watertight hatches to vessel. Provide way to
attach.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2023
Resolved 8 August 2023
Resolution: All hatches are secured with lanyard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 September 2022
Resolved
Provide logbook at operating station.
12/5: updated to prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 September 2022
Resolved
Provide bilge high level alarms in spaces required (attached). Need to be audible and visual at the operating station. E/R bilge High level was the only one working at time of inspection.
12/5: updated to prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 September 2022
Resolved
Provide working tachometer at the operating station for the starboard engine.
12/5: Updated to prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 September 2022
Resolved
Ring Life Buoy on port upper deck needs attention. Provide new grab lines, darken name and add retro.
12/5: Updated to prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 September 2022
Resolved
Child PFD's need to be stowed seperate from Adult PFD's so as not to confuse them. Please seperate child PFD's from Adult PFD's in both stowage locations.
12/5: Updated to prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2022
Resolved
Attach bilge strainer on bilge piping in steering compartment.
12/5: Updated to prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 9 September 2022
Resolved
Post emergency instructions at operating station per 46 CFR 185.510 & 512
12/5: Updated to prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2022
Resolved 9 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 September 2022
Resolved
Complete annual inspection prior to oeprating with passengers. 46 CFR 176.500 (b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2022
Resolved 9 September 2022
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 November 2019
Resolved
Provide copy of FCC Station License. Vessel restricted to 1000' from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2022
Resolution: Vessel route within 1000' from shore.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 October 2017
Resolved
Provide valid COD onboard vessel.
Due 23 November 2017
Resolved 27 October 2017
Resolution: COD provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 October 2017
Resolved
Provide operational bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2017
Resolution: Bilge alarm repaired.
Engineering › Bilge Water Management System › Piping
Issued 1 November 2016
Resolved
Demonstrate proper operation of bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2017
Resolution: Bilge system repaired and tested satisfactory.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 November 2016
Resolved
Conduct annual servicing of engine room fire system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: System serviced.
Stability › Weathertight Integrity › General
Issued 1 November 2016
Resolved
Adjust engine room weather tight door.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 June 2017
Resolution: New gasket installed.
Documentation › Markings/Placards › Warning Signs
Issued 1 November 2016
Resolved
Provide emergency instruction placard IAW 46CFR185.510.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 June 2017
Resolution: Emergency instructions provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 November 2016
Resolved
Provide emergency radio broadcast placard.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 June 2017
Resolution: Emergency radio broadcast placard provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 November 2016
Resolved
Clean heating system battery terminals.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 1 June 2017
Resolution: Batteries replaced.
Engineering › Fuel Oil Service System › Valve
Issued 15 September 2015
Resolved
Label emergency fuel shut off.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: Valve labeled.
Fire Fighting › Fire Main › Condition
Issued 14 September 2015
Resolved
Fire main leaking in engine room when system was charged.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: Fire main tested. All Sat
Engineering › Bilge Water Management System › Pump
Issued 14 September 2015
Resolved
Secure bilge pump in transome.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: Bilge pump secured.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 14 September 2015
Resolved
Label life jacket locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: Life jacket locker labeled.
Engineering › Bilge Water Management System › Not Operational
Issued 14 September 2015
Resolved
Prove operation of bilge system. The bilge in the forepeak and transome works. The rest of the system needs to tested. A check valve was not working in the void aft of the forepeak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 29 October 2015
Resolution: Bilge system repaired and tested satisfactorily.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 September 2015
Resolved
Add refleftive tape to ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 29 October 2015
Resolution: Tape provided.
Engineering › Lubricating Oil Service System › Inlet
Issued 14 September 2015
Resolved
Repair oil leak on PS MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: Oil leak repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 September 2015
Resolved
Replace exhaust cooling hose on STBD MDE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: Cooling hose replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2015
Resolved
Install first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 23 September 2015
Resolution: First aid kit installed.
Lifesaving
Issued 19 April 1999
Resolved
Mount PFD donning placard.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 19 April 1999
Resolved
Mount junction box for spotlight in wheel house.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Lifesaving
Issued 19 April 1999
Resolved
Mark upper deck with max # of passengers allowed as per stability letter.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Construction/Loadline
Issued 19 April 1999
Resolved
Secure manholes to provide for a watertight hull.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Electrical
Issued 19 April 1999
Resolved
Remove or disable 120V shore tie.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 19 April 1999
Resolved
Provide light for compass
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 19 April 1999
Resolved
Provide evidence of nautical chart.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Construction/Loadline
Issued 19 March 1999
Resolved
Repair bow cleat and surrounding structure as original.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Engineering
Issued 19 March 1999
Resolved
Replace or repair flame screen for fuel tank vent, starboard side, forward.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 19 March 1999
Resolved
Reapair valve and reach-rod in collision bulkhead. Valve must be operable using the reach-rod.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 19 March 1999
Resolved
Cap off old bilge discharge in engine room, port side, forward.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 19 March 1999
Resolved
Make permanent repair to steel plating on main deck. Main deck and hatchesshall be made watertight. Repairs shall be made prior to carrying passengers.
Condition: Unknown
Due 30 April 1999
Resolved 2 April 1999
Electrical
Issued 19 March 1999
Resolved
Remove unused conduit from engine room, forward, center. Remove all the way up to the wheel house.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Electrical
Issued 19 March 1999
Resolved
Attach horizontal runs of wire to bulkheads with metal wire ties.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Construction/Loadline
Issued 2 April 1998
Resolved
Provide fastners and cable for all hatch openings.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide first aid kit as required by 46 CFR 184.710.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Engineering
Issued 2 April 1998
Resolved
Provide ventilation closing devices for main engine room.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide a watertight container for distress flares and proper markings as required by 46 CFR 185.614.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide life jacket stowage and markings as required by 46 CFR 180.78.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide emergency instructions as required by 46 CFR 185.510.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide emergency drills and log same as required by 46 CFR 185.524 and 46 CFR 185.520.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Fire Fighting
Issued 2 April 1998
Resolved
Provide servicing for all portable fire fighting appliances as required by 46 CFR 176.810 (b)(1).
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide twelve (12) additional adult PFD's for passenger count of 149.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Lifesaving
Issued 2 April 1998
Resolved
Provide markings on emergency fuel stops as required by 46 CFR 185.608.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Construction/Loadline
Issued 2 April 1998
Resolved
Crop and renew to good steel area where wasted located below the starboard marine sanitation device.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Construction/Loadline
Issued 2 April 1998
Resolved
Crop and renew decking aft port side of pilot station in area where wasted.
Condition: Unknown
Due 2 April 1998
Resolved 2 April 1998
Unknown
Issued 2 April 1997
Resolved
Provide window located on portside of pilothouse.
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Unknown
Issued 2 April 1997
Resolved
Provide holding tank for installed MSD. Vessel is restricted to a (30) minute run until acceptable repairs are made to the satisfaction of a CoastGuard Inspector.
Condition: Unknown
Due 30 April 1997
Resolved 11 April 1997
Unknown
Issued 2 April 1997
Resolved
Provide repairs to main deck house window located aft, midships.
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Unknown
Issued 2 April 1997
Resolved
Provide mounting bracket for horn relay located in pilothouse.
Condition: Unknown
Due 2 April 1997
Resolved 2 April 1997
Lifesaving
Issued 15 February 1996
Resolved
Provide nine additional PFD's. Vessel limited to 143 total persons until provided.
Condition: Unknown
Due 25 February 1996
Resolved 20 February 1996
Lifesaving
Issued 15 February 1996
Resolved
Clean all void spaces of trash and debris.
Condition: Unknown
Due 25 February 1996
Resolved 23 February 1996
Lifesaving
Issued 15 February 1996
Resolved
Provide guard for belt/pulley on S/S air compressor.
Condition: Unknown
Due 25 February 1996
Resolved 23 February 1996
Lifesaving
Issued 13 February 1995
Resolved
Provide 42 additional adult life jackets, type I. Vessel is limited to 95 adults until provided.
Condition: Unknown
Due 13 February 1995
Resolved 13 February 1995
Electrical
Issued 16 February 1994
Resolved
PROVIDE COVER FOR ELECTRICAL BREAKER BOX, 110 VOLT PANAL, IN ENGINE ROOM. PANAL DOOR TO REMAIN CLOSED AT ALL TIMES.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994
Lifesaving
Issued 16 February 1994
Resolved
PROVIDE 29 ADDITIONAL ADULT LIFE PRESERVERS. TOTAL PERSONS ALLOWED LIMITED TO 123 UNTIL PROVIDED.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994
Documentation
Issued 16 February 1994
Resolved
PROVIDE COPY OF NAVIGATIONAL RULES.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994
Documentation
Issued 16 February 1994
Resolved
PROVIDE RADOM DRUG TESTING PROGRAM AND PROVIDE PRE-EMPLOYMENT DRUG TESTING FOR MEMBERS OF CREW NOT TESTED AS REQUIRED BY 46 CFR PART 16.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994
Construction/Loadline
Issued 8 February 1991
Resolved
Properly repair two leaks in sewage holding tanks._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Navigation
Issued 8 February 1991
Resolved
VHF radio failed to shift to any frequency exceot channel 16._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Navigation
Issued 8 February 1991
Resolved
provide push button switch for horn_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Fire Fighting
Issued 8 February 1991
Resolved
Service BII extinguisher in engine room_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Documentation
Issued 8 February 1991
Resolved
Provide tide tables, tidal current tables, light list and nav rules._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Electrical
Issued 8 February 1991
Resolved
Replace 2 battery caps on starting batteries for main engines._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Engineering
Issued 8 February 1991
Resolved
Stencil emergency fuel shut offs on main deck_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Lifesaving
Issued 8 February 1991
Resolved
Provide 6 red and 6 orange hand held flares._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1991
Resolved 8 February 1991
Accommodation/Occupational Safety
Issued 16 November 1990
Resolved
ISSUED REQUIREMENT TO MAKE TYPE III MSD OPERABLE.
Condition: Unknown
Due 16 November 1990
Resolved 16 November 1990
Navigation
Issued 12 March 1990
Resolved
ANCHOR LT & PORT SIDELIGHT INOP.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Lifesaving
Issued 12 March 1990
Resolved
8 ADULT LIFE PRESERVERS CONDEMNED.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Fire Fighting
Issued 12 March 1990
Resolved
B-I PORTABLE CO2 EXTINGUISHER NEEDS TO BE WEIGHED.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Electrical
Issued 12 March 1990
Resolved
REMOVE EXCESS WIRING.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Fire Fighting
Issued 24 February 1989
Resolved
SERVICE BI FIRE EXTINGUISHER IN PILOT HOUSE
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Electrical
Issued 24 February 1989
Resolved
REMOVE HARD WIRE FROM BATTERIES IN ER TO POWER CONVERTER
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Lifesaving
Issued 24 February 1989
Resolved
PROCURE 19 CG APPROVED ADULT PFD'S.
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Construction/Loadline
Issued 17 November 1988
Resolved
RENEW SEA VALVE TO GENERATOR SET
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988
Resolved
REMOVE EXCESS UNUSED WIRING IN ENGINEROOM
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Construction/Loadline
Issued 17 November 1988
Resolved
REMOVE ALL STANDING OIL AND WATER IN ENGINE ROOM BILGE AND FUEL TANK COMPARTMENT
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988
Resolved
MAKE PROPER REPAIRS TO PACKING GLAND THRU DECK FITTINGS FOR EMERGENCY FUEL SHUTOFFS AND FORWARD COMPARTMENT BILGE PIPING
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 25 February 1988
Resolved
PROVE PROPER OPERATION OF ANCHOR LIGHT
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Navigation
Issued 25 February 1988
Resolved
PROVIDE ANCHOR BALL
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Lifesaving
Issued 25 February 1988
Resolved
PROVIDE 60 FEET FLOATABLE TENDING LINE FOR RING BUOY
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Fire Fighting
Issued 25 February 1988
Resolved
SERVICE ALL HAND HELD PORTABLE FIREFIGHTING EQUIPMENT
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Electrical
Issued 25 February 1988
Resolved
LINE BATTERY BOX WITH LEAD OR SUITABLE MATERIAL RESISTANT TO ELECTROLYTE CORROSION.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Construction/Loadline
Issued 25 February 1988
Resolved
PROVIDE CAPTURE CHAINS ON ALL FLUSH DECK HATCHES.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Electrical
Issued 25 February 1988
Resolved
PROPERLY WIRE BATTERY CHARGER LEADS TO STARTING BATTERIES.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Navigation
Issued 25 February 1988
Resolved
PROVIDE UP TO DATE CHARTS AND CURRENT TABLES OF THE VESSELS AUTHORIZED ROUTE.
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Accommodation/Occupational Safety
Issued 25 February 1988
Resolved
PROVE PROPER OPERATION OF MENS TOILET
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Lifesaving
Issued 25 February 1988
Resolved
PROPERLY STOW IN SEPARATE LOCATIONS ALL ADULT AND CHILDS LIFE PRESERVERS
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Engineering
Issued 25 February 1988
Resolved
PROVE PROPER OPERATION OF BOTH MAIN ENGINES
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Electrical
Issued 25 February 1988
Resolved
PROVE PROPER OPERATION OF SHIPS ELECTRICAL GENERATOR
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988
Construction/Loadline
Issued 25 February 1988
Resolved
REPAIR WASTED AREA OF DECK IN PILOT HOUSE
Condition: Unknown
Due 25 February 1988
Resolved 25 February 1988