GAIL FRANCES

Built
1982
Last inspected
26 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WUT2076
Flag
UNITED STATES
Maury page id
psix-54491

Documentation record

Registered dimensions (L × B × D)72.2 ft × 20.8 ft × 6.2 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1982
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSOUTH KINGSTON, RI
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
92 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 32 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

26 May 2026 Deficiency Check · COI Inspection · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8382774
23 February 2026 Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8317272
23 February 2026 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8351408
9 June 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8155793
8 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8108292
17 September 2024 Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8004646
13 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7923171
18 March 2024 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7972859
2 October 2023 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685252
25 September 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7798020
8 June 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685325
3 March 2023 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7643323
2 February 2023 Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7631684
7 October 2022 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7506472
17 August 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7536241
4 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7407094
7 September 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7306154
24 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7219661
9 April 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7152842
30 July 2020 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7020973
30 July 2020 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7023166
18 June 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6967766
18 October 2019 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6838500
19 September 2019 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6816733
10 September 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808159
27 June 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6719317
5 February 2019 Drydock Exam · Internal Structural Exam · Deficiency Check · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6614227
27 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6524268
8 May 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6397416
18 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6126488
4 April 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6112903
2 June 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878851

Deficiency record · 50

03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 February 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel is undergoing repairs following a partial sinking at the dock. All spaces to be internally inspected and all machinery to be tested and an annual inspection must be completed to the satisfaction of the attending CG marine inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 April 2025 Resolved
Repair identified sections of fiberglass on bowsprit
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 June 2024 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110 Batteries installed were expired and shall be replaced.
Action required: 10 - Deficiency Rectified
Due 13 June 2024
Resolved 17 June 2024
Resolution: Repairs made to the satisfaction of the attending marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2024 Resolved
The minimum capacity of the power fire pump shall be 50 GPM and not less than 60 PSI at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Fire pump outlet is not fitted with pressure gauge. Corrected 6/13/24
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Repairs made to the satisfaction of the attending marine inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2024 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig), may meet the following requirements, Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. All main engine R/W intake hoses only had one clamp on each side of intake hose.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Repairs made to the satisfaction of the attending marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2024 Resolved
Vital Systems. Mechanically propelled "L" vessels shall comply with the provisions of sub-chapter F of this chapter. Nonmetallic flexible hose Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference; see 46 CFR 56.01-2) and may be installed only in vital and nonvital fresh and salt water systems, nonvital pneumatic systems, lube oil and fuel systems, and fluid power systems. Nonmetallic flexible hose must have factory-assembled end fittings requiring no further adjustment or field attachable fittings. Hose end fittings must comply with SAE J1475. flex hoses in pressure side of electric fire pump do not meet subchapter F requirements for hoses for factory assembled end fittings and are not exempted by the less than five PSI rule in 46 CFR 182.720 (e) (3) (v). Owner to provide acceptable plan to repair to CG within 30 days date of issue 6/17/24. Due on 7/17/24
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 28 August 2024
Resolution: Nonmetallic flex hose replaced and system operationally tested.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 8 June 2023 Resolved
Two flexible non-metallic hoses for the winch/capstan penetrate the watertight main deck. Each penetration must be accomplished using an acceptable metallic through deck fitting that is welded or otherwise attached to the deck by an accepted method; and one metallic shutoff valve must be installed if operable from above the bulkhead deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 6 August 2024
Resolution: special consideration granted, existing condition, update to new T when renewed.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 17 August 2022 Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. Submit detailed plans for your proposal to include general arrangement/locations and bill of materials for the installation to include cable sizes/length for plan approval and install the system prior to 30Sep2022.
Action required: 705 - Other - as specified
Due 30 September 2022
Resolved 25 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022 Resolved
Provide data plate information and make available for testing/inspection the auxiliary boiler in the pilothouse to the satisfaction of the attending USCG Marine Inspector prior to placing into service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2022
Resolved 17 February 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 April 2022 Resolved
Vessels must submit plans to the cognizant OCMI for the installation and use of monitoring device to ensure wakefulness of the watchmen required in 46 CFR 185.410(a). The monitoring device must: (1) Ensure the wakefulness of the crew in the event that watchman is unresponsive. (2) Remains operable during nighttime watch. (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to Sector SENE for watchstanding monitoring device; plans to include, but not limited to: device spec sheet, how device is to be installed/powered, how & when device is to be implemented, device locations, testing procedures & any other maintenance requirements for the device.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 14 June 2022
Resolution: Plan submitted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2021 Resolved
Wire on top of pilothouse is exposed from protective sheathing. Properly replace or remove wiring/cable to the satisfaction of marine inspector. 46 CFR 183.01-15 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 24 September 2021
Resolution: Damaged wire was replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2021 Resolved
The galley lower electrical panel has no blanks and is an exposed electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 June 2021 Resolved
There is no CO2 sign at the fixed fire system pull station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
Resolution: Placed CO2 sign at the pull station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021 Resolved
Secure stern light and fix wiring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021 Resolved
Repaint navigation light screens matte black.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
Resolution: Repainted screen matte black.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021 Resolved
Repair or replace port and starboard running navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2021 Resolved
One of the vessel's ring buoys was worn and in need of replacement. Found a different ring buoy, restenciled.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 June 2021
Resolution: Vessel rep obtained a different ring buoy and placed it on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2020 Resolved
Vessl reported a total loss of steering after a "t" connection in the hydraulic line bursted. Per 46 CFR 182.610(a)(1), a vessel must be provided with a main steering gear that is of adequate stregnth and capable of steering the vessel at all service speeds. Vessel is directed to effect repairs and prove satisfactory operation to a CG MI, prior to embarkation of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2020
Resolved 31 July 2020
Resolution: Vessel removed three "T" connections from the hydraulic system in the lazarette, replaced with in line connections. MI verified installation, conducted satisfactory sea trials, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 September 2019 Resolved
Update emergency instructions/station bill to include designated crew member as a watch patrolman.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Update log book to organize weekly, monthly, quarterly, and annual inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Provide a means to log watch patrolman rounds when watch patrolman is required to be conducting rounds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Create a voyage plan to be included with passenger count/lists when making overnight voyages.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Provide documentation/check list to include records of instruction of each crew member of their duties, responsiblities, and ability/knowledge/familiarization of the location and to utilize all emergency equipment as per 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 September 2019 Resolved
Update passenger safety orientation to include the request of passengers to don a life jacket when on a voyage of more than 24 hrs as per 46 CFR 185.506(e).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2019 Resolved
Provide documentation that smoke detectors meet UL 217 standard as per 46 CFR 181.450.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 June 2019 Resolved
VHF radios we're not able to receive GPS information with Lat and Long. Prove proper operation of VHF radios.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 June 2019 Resolved
Vessel's name, retro tape, and number of persons were worn off life floats and paddles. Remark accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2019 Resolved
Vessel's name and retro tape worn, Remark ringbuoys with name and new retro tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 June 2019 Resolved
Properly stow painter line for the lifefloat located on the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2019 Resolved
Properly mark life jacket stowage locations to include type and number of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 June 2019 Resolved
Provide guard for the center MDE vibration damper prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 June 2019 Resolved
Provide stabilty letter to address weight changes for repowering the vessel within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 18 October 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2019 Resolved
Make approved wood repairs to port quarter where main deck meets the side shell where deck beams and ceiling plywood were rotted. Prior to credit DD.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 February 2019
Resolved 7 June 2019
Resolution: Witnessed sat wood repairs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: No static draft information, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 13 November 2018
Resolution: AIS corrected errors, verified.
Electrical › Lighting (service) › Outlet Box
Issued 8 May 2018 Resolved
Plug lighting fixture over STBD MDE into a grounded outlet.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Plugged lighting fixture over STBD MDE into a grounded outlet.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 May 2018 Resolved
Properly mount lighting fixtures in Engine room over STBD MDE and Port generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Properly mounted lighting fixtures in Engine room over STBD MDE and Port generator.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 8 May 2018 Resolved
Renew exhaust lagging on center MDE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Witnessed newly installed lagging
Electrical › Electric Supply System (service) › Battery Charger
Issued 8 May 2018 Resolved
Remove terminated leads on battery charger.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Witnessed removed leads on battery charger
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 8 May 2018 Resolved
Install additional hose clamp on exhaust flex hose port side of Engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Witnessed installed hose clamp on exhaust flex.
Engineering › Bilge Water Management System › Manifold
Issued 8 May 2018 Resolved
Install handle for ball valve on manifold for tank room bilge suction.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 May 2018
Resolution: Witnessed newly installed handle on ball valve for bilge manifold.
Engineering › Fuel Oil Service System › Filter
Issued 8 May 2018 Resolved
Clean growth in fuel system treat as needed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 May 2018
Resolution: Witnessed growth in fuel system removed from sight glass bowls on racor fuel system.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 May 2018 Resolved
Fix broken handrail port bow.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 May 2018
Resolved 10 May 2018
Resolution: Witnessed weld repair to broken hand rail.
Fire Fighting › Fire Hoses › Condition
Issued 8 May 2018 Resolved
Replace STBD side fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 10 May 2018
Resolution: Witnessed newly installed fire hose.
Engineering › Steering Gear System › Linkage
Issued 8 May 2018 Resolved
Repair or replace port hydraulic ram mount.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 9 May 2018
Resolution: Witnessed sufficient repair made to hydraulic ram mount.
Fire Fighting › Fire Pumps › Pressure
Issued 8 May 2018 Resolved
Install new gauge on fire pump to show accurate water pressure.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 May 2018
Resolution: Witnessed newly installed pressure gauge on fire pump showing accurate pressure.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2017 Resolved
Conduct drills and underway sea trials.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Conducted drills and underway sea trials.
Engineering › Steam Boiler (auxiliary/waste heat) › Furnace
Issued 4 April 2017 Resolved
Provide report of service for boiler inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Provided report of service for boiler inspection.
Fire Fighting › Fire Pumps › Pressure
Issued 4 April 2017 Resolved
Install pressure gauge for engine room fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Installed pressure gauge for engine room fire pump.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 April 2017 Resolved
Re-lable max passengers for top deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Re-lable max passengers for top deck.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 2 June 2016 Resolved
Adequately label ventilation closeures and guards to match up with proper locations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 9 June 2016