MAURY USCG vessel records Sign in
← All vessels

GAIL FRANCES

GAIL FRANCES is a 1982 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1985, most recently in May 2026, along with 125 deficiencies and 4 casualty investigations between 2009 and 2026.

Records from 1985 to 2026. Most recent: inspection, 26 May 2026.

Built
1982
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUT2076
Flag
UNITED STATES
366940990
Maury page id
psix-54491

Inspections, by type

…with no type recorded10
Years with a record 38 calendar years (1985–2026)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.2 ft × 20.8 ft × 6.2 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1982
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSOUTH KINGSTON, RI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
92 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WUT2076MMSI 366940990 · active · compulsorily equipped · granted 3 May 2024, expires 17 May 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 88

26 May 2026 Deficiency Check · COI Inspection · Vessel Attendance
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8382774
23 February 2026 Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8317272
23 February 2026 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8351408
9 June 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8155793
8 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8108292
17 September 2024 Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 8004646
13 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7923171
18 March 2024 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7972859
2 October 2023 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685252
25 September 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7798020
8 June 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7685325
3 March 2023 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7643323
2 February 2023 Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7631684
7 October 2022 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7506472
17 August 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7536241
4 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7407094
7 September 2021 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7306154
24 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7219661
9 April 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7152842
30 July 2020 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7020973
30 July 2020 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7023166
18 June 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6967766
18 October 2019 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6838500
19 September 2019 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6816733
10 September 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808159
27 June 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6719317
5 February 2019 Drydock Exam · Internal Structural Exam · Deficiency Check · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6614227
27 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6524268
8 May 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6397416
18 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6126488
4 April 2017 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6112903
2 June 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5878851
3 June 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4818833
30 January 2012 COI Inspection · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4234515
7 July 2009 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3527820
28 April 2009 DAPI Audit · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3445491
9 March 2009 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3424199
2 December 2008 Drydock Extension · Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3370556
22 April 2008 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3167525
16 January 2008 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3131762
12 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2959012
7 March 2007 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2846696
21 March 2006 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2581741
17 March 2005 Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2290933
6 December 2004 Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2254004
20 April 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2039975
6 April 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2036282
10 April 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1766299
14 March 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1493573
26 February 2002 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1489238
1 September 2001 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1449517
1 September 2001 Damage Survey
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1459740
31 August 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 14034
10 April 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1465670
14 March 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1433614
10 February 2000 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1426336
29 July 1999 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 774828
2 March 1999 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1451394
14 April 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1122973
7 April 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 786862
21 April 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1102321
25 April 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1141364
27 February 1996 COI Inspection · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884883
7 April 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 840815
5 April 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1151127
4 April 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1356758
26 October 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 84930
14 April 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 162262
8 April 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1457090
6 April 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1443364
27 February 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 954703
3 December 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1252608
5 March 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 934846
5 March 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1243200
30 August 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1231765
12 March 1990 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 907407
2 May 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1205502
21 March 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 896067
21 November 1988 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1204623
5 May 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039643
30 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991674
28 March 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991673
1 April 1987 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018987
25 March 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018574
2 April 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304751
5 February 1986 Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 996967
27 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289343
20 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289336

Deficiency record · 125

03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 February 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel is undergoing repairs following a partial sinking at the dock. All spaces to be internally inspected and all machinery to be tested and an annual inspection must be completed to the satisfaction of the attending CG marine inspector prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2026
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 April 2025 Resolved
Repair identified sections of fiberglass on bowsprit
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 June 2024 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110 Batteries installed were expired and shall be replaced.
Action required: 10 - Deficiency Rectified
Due 13 June 2024
Resolved 17 June 2024
Resolution: Repairs made to the satisfaction of the attending marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2024 Resolved
The minimum capacity of the power fire pump shall be 50 GPM and not less than 60 PSI at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Fire pump outlet is not fitted with pressure gauge. Corrected 6/13/24
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Repairs made to the satisfaction of the attending marine inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2024 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig), may meet the following requirements, Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. All main engine R/W intake hoses only had one clamp on each side of intake hose.
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: Repairs made to the satisfaction of the attending marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 June 2024 Resolved
Vital Systems. Mechanically propelled "L" vessels shall comply with the provisions of sub-chapter F of this chapter. Nonmetallic flexible hose Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference; see 46 CFR 56.01-2) and may be installed only in vital and nonvital fresh and salt water systems, nonvital pneumatic systems, lube oil and fuel systems, and fluid power systems. Nonmetallic flexible hose must have factory-assembled end fittings requiring no further adjustment or field attachable fittings. Hose end fittings must comply with SAE J1475. flex hoses in pressure side of electric fire pump do not meet subchapter F requirements for hoses for factory assembled end fittings and are not exempted by the less than five PSI rule in 46 CFR 182.720 (e) (3) (v). Owner to provide acceptable plan to repair to CG within 30 days date of issue 6/17/24. Due on 7/17/24
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 28 August 2024
Resolution: Nonmetallic flex hose replaced and system operationally tested.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 8 June 2023 Resolved
Two flexible non-metallic hoses for the winch/capstan penetrate the watertight main deck. Each penetration must be accomplished using an acceptable metallic through deck fitting that is welded or otherwise attached to the deck by an accepted method; and one metallic shutoff valve must be installed if operable from above the bulkhead deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 6 August 2024
Resolution: special consideration granted, existing condition, update to new T when renewed.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 17 August 2022 Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. Submit detailed plans for your proposal to include general arrangement/locations and bill of materials for the installation to include cable sizes/length for plan approval and install the system prior to 30Sep2022.
Action required: 705 - Other - as specified
Due 30 September 2022
Resolved 25 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2022 Resolved
Provide data plate information and make available for testing/inspection the auxiliary boiler in the pilothouse to the satisfaction of the attending USCG Marine Inspector prior to placing into service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2022
Resolved 17 February 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 April 2022 Resolved
Vessels must submit plans to the cognizant OCMI for the installation and use of monitoring device to ensure wakefulness of the watchmen required in 46 CFR 185.410(a). The monitoring device must: (1) Ensure the wakefulness of the crew in the event that watchman is unresponsive. (2) Remains operable during nighttime watch. (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to Sector SENE for watchstanding monitoring device; plans to include, but not limited to: device spec sheet, how device is to be installed/powered, how & when device is to be implemented, device locations, testing procedures & any other maintenance requirements for the device.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 14 June 2022
Resolution: Plan submitted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2021 Resolved
Wire on top of pilothouse is exposed from protective sheathing. Properly replace or remove wiring/cable to the satisfaction of marine inspector. 46 CFR 183.01-15 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2021
Resolved 24 September 2021
Resolution: Damaged wire was replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2021 Resolved
The galley lower electrical panel has no blanks and is an exposed electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 June 2021 Resolved
There is no CO2 sign at the fixed fire system pull station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
Resolution: Placed CO2 sign at the pull station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021 Resolved
Secure stern light and fix wiring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021 Resolved
Repaint navigation light screens matte black.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
Resolution: Repainted screen matte black.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021 Resolved
Repair or replace port and starboard running navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2021 Resolved
One of the vessel's ring buoys was worn and in need of replacement. Found a different ring buoy, restenciled.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 June 2021
Resolution: Vessel rep obtained a different ring buoy and placed it on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 July 2020 Resolved
Vessl reported a total loss of steering after a "t" connection in the hydraulic line bursted. Per 46 CFR 182.610(a)(1), a vessel must be provided with a main steering gear that is of adequate stregnth and capable of steering the vessel at all service speeds. Vessel is directed to effect repairs and prove satisfactory operation to a CG MI, prior to embarkation of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2020
Resolved 31 July 2020
Resolution: Vessel removed three "T" connections from the hydraulic system in the lazarette, replaced with in line connections. MI verified installation, conducted satisfactory sea trials, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 September 2019 Resolved
Update emergency instructions/station bill to include designated crew member as a watch patrolman.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Update log book to organize weekly, monthly, quarterly, and annual inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Provide a means to log watch patrolman rounds when watch patrolman is required to be conducting rounds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Create a voyage plan to be included with passenger count/lists when making overnight voyages.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 September 2019 Resolved
Provide documentation/check list to include records of instruction of each crew member of their duties, responsiblities, and ability/knowledge/familiarization of the location and to utilize all emergency equipment as per 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 September 2019 Resolved
Update passenger safety orientation to include the request of passengers to don a life jacket when on a voyage of more than 24 hrs as per 46 CFR 185.506(e).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2019 Resolved
Provide documentation that smoke detectors meet UL 217 standard as per 46 CFR 181.450.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 June 2019 Resolved
VHF radios we're not able to receive GPS information with Lat and Long. Prove proper operation of VHF radios.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 June 2019 Resolved
Vessel's name, retro tape, and number of persons were worn off life floats and paddles. Remark accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2019 Resolved
Vessel's name and retro tape worn, Remark ringbuoys with name and new retro tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 June 2019 Resolved
Properly stow painter line for the lifefloat located on the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2019 Resolved
Properly mark life jacket stowage locations to include type and number of life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2019
Resolved 28 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 June 2019 Resolved
Provide guard for the center MDE vibration damper prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 June 2019 Resolved
Provide stabilty letter to address weight changes for repowering the vessel within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2019
Resolved 18 October 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2019 Resolved
Make approved wood repairs to port quarter where main deck meets the side shell where deck beams and ceiling plywood were rotted. Prior to credit DD.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 February 2019
Resolved 7 June 2019
Resolution: Witnessed sat wood repairs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: No static draft information, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 13 November 2018
Resolution: AIS corrected errors, verified.
Electrical › Lighting (service) › Outlet Box
Issued 8 May 2018 Resolved
Plug lighting fixture over STBD MDE into a grounded outlet.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Plugged lighting fixture over STBD MDE into a grounded outlet.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 May 2018 Resolved
Properly mount lighting fixtures in Engine room over STBD MDE and Port generator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 15 May 2018
Resolution: Properly mounted lighting fixtures in Engine room over STBD MDE and Port generator.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 8 May 2018 Resolved
Renew exhaust lagging on center MDE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Witnessed newly installed lagging
Electrical › Electric Supply System (service) › Battery Charger
Issued 8 May 2018 Resolved
Remove terminated leads on battery charger.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Witnessed removed leads on battery charger
Engineering › Diesel Engine (propulsion-reduction gear) › Waste Heat Recovery
Issued 8 May 2018 Resolved
Install additional hose clamp on exhaust flex hose port side of Engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 9 May 2018
Resolution: Witnessed installed hose clamp on exhaust flex.
Engineering › Bilge Water Management System › Manifold
Issued 8 May 2018 Resolved
Install handle for ball valve on manifold for tank room bilge suction.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 May 2018
Resolution: Witnessed newly installed handle on ball valve for bilge manifold.
Engineering › Fuel Oil Service System › Filter
Issued 8 May 2018 Resolved
Clean growth in fuel system treat as needed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 May 2018
Resolution: Witnessed growth in fuel system removed from sight glass bowls on racor fuel system.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 May 2018 Resolved
Fix broken handrail port bow.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 May 2018
Resolved 10 May 2018
Resolution: Witnessed weld repair to broken hand rail.
Fire Fighting › Fire Hoses › Condition
Issued 8 May 2018 Resolved
Replace STBD side fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 10 May 2018
Resolution: Witnessed newly installed fire hose.
Engineering › Steering Gear System › Linkage
Issued 8 May 2018 Resolved
Repair or replace port hydraulic ram mount.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2018
Resolved 9 May 2018
Resolution: Witnessed sufficient repair made to hydraulic ram mount.
Fire Fighting › Fire Pumps › Pressure
Issued 8 May 2018 Resolved
Install new gauge on fire pump to show accurate water pressure.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 10 May 2018
Resolution: Witnessed newly installed pressure gauge on fire pump showing accurate pressure.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2017 Resolved
Conduct drills and underway sea trials.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Conducted drills and underway sea trials.
Engineering › Steam Boiler (auxiliary/waste heat) › Furnace
Issued 4 April 2017 Resolved
Provide report of service for boiler inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Provided report of service for boiler inspection.
Fire Fighting › Fire Pumps › Pressure
Issued 4 April 2017 Resolved
Install pressure gauge for engine room fire pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Installed pressure gauge for engine room fire pump.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 4 April 2017 Resolved
Re-lable max passengers for top deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 17 May 2017
Resolution: Re-lable max passengers for top deck.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 2 June 2016 Resolved
Adequately label ventilation closeures and guards to match up with proper locations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 9 June 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 June 2014 Resolved
Install guards on front of port and starboard main engines.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 2 July 2014
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 3 June 2014 Resolved
Provide FCC Bridge to Bridge certificate.
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 2 July 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 30 January 2012 Resolved
CO2 system must be pressure tested IAW 46 CFR 181.410 (d)(7)(ii) prior to approval.
Action required: 705 - Other - as specified
Due 3 May 2012
Resolved 2 October 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 30 January 2012 Resolved
Plans and bill of materials must be approved IAW 46 CFR 177.202.
Action required: 705 - Other - as specified
Due 3 May 2012
Resolved 2 October 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 30 January 2012 Resolved
Storage space for CO2 Tanks and controls not labelled IAW 46 CFR 185.612(f)
Action required: 705 - Other - as specified
Due 10 April 2012
Resolved 10 April 2012
Stability › Watertight Integrity › General
Issued 9 March 2009 Resolved
Replace cracked windows in pilot house.
Action required: 705 - Other - as specified
Due 19 April 2009
Resolved 28 April 2009
Resolution: Window replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 15 December 2008 Resolved
Complete credit dry dock exam and internal structure exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2008
Resolved 19 March 2009
Resolution: Drydock inspection completed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 December 2008 Resolved
Repair or replace railing on 01 deck for ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2008
Resolved 10 December 2008
Resolution: Rcvd digital picture from owner showing railing was repaired.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 16 January 2008 Resolved
INSTALL USCG APPROVED FIRE DETECTION SYSTEM IN ACCORDANCE WITH 46CFR181.400(C) BY 28FEB08.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2008
Resolved 29 April 2008
Resolution: Received fire system diagram. Scanned and attached to activity. [name withheld] who had lead is out due to unexected injury but said ready to clear.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 5 April 2007 Resolved
Demonstrate fixed fire detection system is electrically supervised or replace with an approved electrically supervised detector IAW 46 CFR181.400(c). System to be tested monthly until requirement is met.
Action required: 705 - Other - as specified
Due 1 November 2007
Resolved 29 April 2008
Resolution: Fire system previously checked out ok. Received system info we were waiting for.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 March 2007 Resolved
Replace or repair CO2/Smoke detector in pilot house.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 5 April 2007
Resolution: New detector installed in pilot house.
Lifesaving › Lifefloat › Pendant
Issued 8 March 2007 Resolved
Re-fit ties on pendant hanks of 3 life floats with proper material.
Action required: 705 - Other - as specified
Due 23 March 2007
Resolved 5 April 2007
Resolution: All life float hanks secured with rubber bands until order of plastic easy to break wire ties come in.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2007 Resolved
Prove proper servicing of all fixed and portable fire extinguishing units.
Action required: 705 - Other - as specified
Due 23 March 2007
Resolved 5 April 2007
Resolution: All servicing paperwork in order as per Firex.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 March 2006 Resolved
Properly label and blank off open spaces in lower electric panel in bar area.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 11 April 2006
Resolution: Witnessed SAT
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 March 2006 Resolved
Properly label escape hatch in engine room.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 11 April 2006
Resolution: Witnessed SAT
Engineering › Fuel Oil Service System › Hose
Issued 21 March 2006 Resolved
Properly clamp fuel supply hose above starboard fuel tank.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 11 April 2006
Resolution: Witnessed SAT
Engineering › Fuel Oil Service System › Hose
Issued 21 March 2006 Resolved
Properly clamp generator fuel supply and return hoses.
Action required: 705 - Other - as specified
Due 20 April 2006
Resolved 11 April 2006
Resolution: Witnessed SAT.
Lifesaving › Lifefloat › Painter
Issued 8 February 2006 Resolved
Vessel is limited to 44 passengers until 25 person lifefloat is properly attached to painter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2006
Resolution: Witnessed SAT.
Fire Fighting › Fire Pumps › Capacity
Issued 17 March 2005 Resolved
FIRE PUMP PRESSURE NOT AT 60PSI/50GPM. FIRE PRESSURE ADEQUATE TO ALLOW TIME, VICE NO SAIL.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 6 April 2005
Resolution: TESTED 4/26 AT 48-50 PSI / 75 GPM. ADEQUATE FIRE PRESS AND QTY, ACCEPTED AS EQUIVALENT LEVEL OF SAFETY. NEW PUMP HOUSING WAS INSTALLED & IMPELLER CLEANED OUT.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2005 Resolved
ANCHOR LIGHT EXTINGUISHED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 March 2005
Resolved 17 March 2005
Resolution: CHANGED OUT.
Navigation › Piloting/Steering › Marine Charts
Issued 17 March 2005 Resolved
UPDATE MARINE CHART FOR AOR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 6 April 2005
Resolution: REPLACED ALL CHARTS, VERIFIED ONBOARD 4/26.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2005 Resolved
RE-ROUTE WIRING FOR ELECTRIC CLUTCH, SUBJECT TO MECHANICAL DAMAGE AT INSTALLED LOCATION.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 6 April 2005
Resolution: ROUTED UNDER ENGINE BED STRINGER VICE OVER. VERIFIED 4/26
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 March 2005 Resolved
PROVIDE STOWAGE FOR A MINIMUM OF 35 LIFEJACKETS ON THE UPPER DECK.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 26 April 2005
Resolution: STOWAGE FOR 35 JACKETS PROVIDED ON THE UPPER DECK.
Fire Fighting › Fire Hoses › Location
Issued 17 March 2005 Resolved
FIRE HOSES NOT STOWED ON STATION. FABRICATE BOXES TO HOLD HOSES ON DECK CONNECTED TO FIRE HYDRANT.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 30 May 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 March 2005 Resolved
DISTRIBUTION PANEL DOORS MISSING CLOSURE DEVICE, NEED CB BLANKS INSTALLED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2005
Resolved 6 May 2005
Resolution: INSTALLED LATCH AND BLANKS, VERIFIED 4/26
Navigation › Piloting/Steering › Marine Charts
Issued 20 April 2004 Resolved
Provide updated charts.
Condition: Unknown
Due 20 May 2004
Resolved 6 May 2004
Resolution: Charts provided.
Communications › Radio Communications
Issued 20 April 2004 Resolved
Provide Emergency broadcast placard LEGACY COMPONENT DESC: emergency broad cast placard
Condition: Unknown
Due 20 May 2004
Resolved 6 May 2004
Resolution: Provided same.
Lifesaving › Rigid Liferafts
Issued 20 April 2004 Resolved
Address multible issues with life floats.
Condition: Unknown
Due 20 May 2004
Resolved 6 May 2004
Resolution: All issues addressed sat.
Lifesaving › Lifebuoys › Stowage
Issued 20 April 2004 Resolved
Replace port and starboard lifering.
Condition: Unknown
Due 20 May 2004
Resolved 6 May 2004
Resolution: Liferings replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 February 2002 Resolved
Conduct man overboard and fire drills to the satisfaction of the attending Marine Inspector.
Due 15 March 2002
Resolved 14 March 2002
Resolution: Man overboard and fire drills satisfactorly conducted
Operations/Management › Passenger Operations
Issued 26 February 2002 Resolved
Properly label maximum persons allowed on 02 deck.
Due 15 March 2002
Resolved 14 March 2002
Resolution: Maximum passenger count stenciled.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 February 2002 Resolved
Provide blank for galley breaker box.
Due 15 March 2002
Resolved 14 March 2002
Resolution: Blank installed in breaker box.
Engineering › Steering Gear System › Hydraulic Hose
Issued 26 February 2002 Resolved
Replace steering hose on port side and adjust bar to avoid rubbing on steering stock.
Due 15 March 2002
Resolved 14 March 2002
Resolution: Repairs made to satisfaction of attending Marine Inspector.
Lifesaving
Issued 1 September 2001 Resolved
REPAIR ALL DAMAGED SYSTEMS; PROPULSION, ELECTRICAL, F/F, HYDRAULIC, UNDERDECK STRUCTURAL DAMAGE. SUBMITT PLANS AS NEEDED. REPAIR TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 September 2001
Resolved 15 November 2001
Unknown
Issued 10 April 2001 Resolved
REPAIR FUEL FILL PIPING W/O PORT TANK(SOFT PATCH).
Condition: Unknown
Due 24 April 2001
Resolved 6 July 2001
Unknown
Issued 10 April 2001 Resolved
REPAIR COATING 25 MAN LIFEFLOAT W/O BRIDGE.
Condition: Unknown
Due 24 April 2001
Resolved 6 July 2001
Unknown
Issued 14 March 2000 Resolved
REPAIR FUEL VALVE ON STBD MAIN ENGINE. ENSURE THE VALVE DOES NOT LEAK.
Condition: Unknown
Due 15 April 2000
Resolved 17 March 2000
Unknown
Issued 14 March 2000 Resolved
REPLACE EXHAUST ELBOW ON CENTER MAIN ENGINE. ENSURE THERE ARE NO COOLING WATER LEAKS.
Condition: Unknown
Due 15 April 2000
Resolved 6 April 2000
Unknown
Issued 14 March 2000 Resolved
CONDUCT MAN OVERBOARD DRILL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 April 2000
Resolved 17 March 2000
Unknown
Issued 14 March 2000 Resolved
PROVE PROPER OPERATION OF BILGE ALARM IN TANK ROOM AND LAZERETTE.
Condition: Unknown
Due 15 April 2000
Resolved 17 March 2000
Unknown
Issued 14 March 2000 Resolved
PROPERLY SECURE WIRE RUN ON PORTSIDE OF ENGINE ROOM ALONG BILGE.
Condition: Unknown
Due 15 April 2000
Resolved 6 April 2000
Lifesaving
Issued 2 March 1999 Resolved
CONDUCT UNDERWAY FIRE AND EMERGENCY DRILLS UPON HIRING SEASONAL PERSONNEL.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 7 April 1998 Resolved
Improper screens on fuel tank vents. Corrected on the spot.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Electrical
Issued 27 February 1996 Resolved
INSTALL COVER ON OUTLET LOCATED IN THE TANK ROOM OVERHEAD
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
TAPE ALL WIRE NUTS LOCATED IN TANK ROOM
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
INSTALL NEW LIGHT GUARDS ON THE PORT HEAD LIGHT, FORWARD MOST PORT DECK LIGHT, PORT LIGHT LOCATED AFT OF THE BRIDGE
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Unknown
Issued 27 February 1996 Resolved
INSTALL NEW WHIPPING ON STBD ANCHOR LINE WHERE IT MEETS THE CHAIN
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Engineering
Issued 27 February 1996 Resolved
TIGHTEN PACKING ON STBD ENGINE F/O RETURN LINE LOCATED ON THE OVERHEAD IN FRONT OF THE ENGINE
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
REPLACE GROUNDING WIRE LOCATED AFTER THE STBD ENGINE R/W STRAINER
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
SEAL THE LIGHT LOCATED IN THE ENGINEROOM BELOW THE GALLEY 120 VOLT POWER PANEL TO PREVENT WATER FROM GETTING INTO IT.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Engineering
Issued 27 February 1996 Resolved
SECURE CENTER ENGINE EXHAUST BRACKET LOCATED IN THE OVERHEAD
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Engineering
Issued 27 February 1996 Resolved
TIGHTEN CENTER ENGINE MOTOR MOUNTS
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Engineering
Issued 27 February 1996 Resolved
INSTALL PLUGS IN VALVES LOCATED ON BOTTOM OF F/O TANKS
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
INSTALL GROUNDING STRAP ON STBD WATER TANK
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
INSTALL COVER ON FRESH WATER PUMP PRESSURE CONTROL SWITCH
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
INSTALL LABELS ON THE SPARE BREAKERS IN THE BOTTOM 120 VOLT PANEL LOCATED IN THE GALLEY
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
REPLACE POSITIVE CABLE LUG ON PORT MAIN ENG START BATTERY.
Condition: Unknown
Due 22 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 27 February 1996 Resolved
REPLACE BILGE SUCTION PIPE IN THE CENTER BEARTHING AREA, DAMAGED SECTION ISJUST BEFORE THE FLEX HOSE ON THE PIPE.
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 27 February 1996 Resolved
REPLACE STBD BRIDGE LIFE RING
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
REPLACE OUTLET LOCATED ON PORT AFT OF THE BRIDGE
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Lifesaving
Issued 27 February 1996 Resolved
REPLACE 04 OARS LOCATED WITH BUOYANT APPARATUS
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
INSTALL LABELS ON 02 BREAKERS IN 12 VOLT BRIDGE PANEL
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
PLACE WOOD IN THE STBD GENERATOR BATTERY BOX TO PREVENT EXCESSIVE MOVEMENT
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Electrical
Issued 27 February 1996 Resolved
REPLACE OUTLET BOX LOCATED IN THE FORWARD PART OF THE ENGINEROOM
Condition: Unknown
Due 11 March 1996
Resolved 11 March 1996
Navigation
Issued 27 February 1996 Resolved
REPLACE ALL NAVIGATION CHARTS WITH NEW UPDATED CHARTS
Condition: Unknown
Due 22 March 1996
Resolved 11 March 1996
Lifesaving
Issued 7 April 1995 Resolved
MAKE PERM REPAIRS TO BUOYANT APPARATUS, REPLACE, OR REMOVE FROM VESSEL.
Condition: Unknown
Due 7 April 1995
Resolved 28 April 1995
Engineering
Issued 30 March 1988 Resolved
PROVIDE PERSONNEL GUARD ON BELT DRIVEN BILGE PUMP ON CENTER MAIN DIESEL ENGINE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Lifesaving
Issued 30 March 1988 Resolved
REPAIR HOLES AND DAMAGE TO EXTERIOR OF (2) LIFEFLOATS.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Documentation
Issued 30 March 1988 Resolved
RENEW RADIO STATION LICENSE.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Navigation
Issued 30 March 1988 Resolved
OBTAIN CURRENT EDITIONS OF LIGHT LIST, COAST PILOT TIDE TABLES AND RULES OF THE ROAD.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Navigation
Issued 30 March 1988 Resolved
OBTAIN 12 INCH SHIPS BELL.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Lifesaving
Issued 30 March 1988 Resolved
REMARK LOCATIONS OF PFD STOWAGE AND EMERGENCY FUEL OIL SHUTOFFS.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Electrical
Issued 30 March 1988 Resolved
PROVE PROPER OPERATION OF PORT GENERATOR.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Construction/Loadline
Issued 25 March 1987 Resolved
INSTALL RETAINING CHAIN ON THE HATCH TO THE FOREPEAK SPACE.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987
Lifesaving
Issued 25 March 1987 Resolved
REPLACE GRAB LINES ON THE THREE LIFE FLOATS.
Condition: Unknown
Due 25 March 1987
Resolved 25 March 1987

Casualty record · 4

7 July 2009Routine · role: Involved in a Marine Casualty · activity 3527820
17 June 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3855449
30 July 2020Routine · role: Involved in a Marine Casualty · activity 7020973
23 February 2026Routine · role: Involved in a Marine Casualty · activity 8351408
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.