Records from 2016 to 2025. Most recent: inspection, 11 June 2025.
Documentation record
Registered dimensions (L × B × D)57.9 ft × 19.1 ft × 5.0 ft
Registered tonnagegross 48 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT & D INDUSTRIES · FORT PIERCE, FL, UNITED STATES · built 1982
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRYE, NH
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 June 2025 · expires 30 June 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Net Ton
48 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
11 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8157270
26 December 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8049193
6 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7928914
25 May 2023
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7696372
7 December 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7605052
17 May 2022
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7452739
16 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7278967
7 January 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7121760
30 July 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7020181
1 May 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6674270
17 December 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6598881
29 May 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6427762
11 April 2017
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6122259
21 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6045363
16 May 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5878483
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 June 2024
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six orange smoke distress signals. Taking into account substitutions, vessel was missing three distress signals.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 11 June 2024
Resolution: New distress signals purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2024
Resolved
Vessel requires one adult life jacket for each person carried. Marine inspector condemned 05 life jackets. Vessel is short 02 life jackets (adult). Limited pax count by 02 adults.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 11 June 2024
Resolution: New PFDs purchased and placed into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is in operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 11 June 2024
Resolution: Failed electrical connection was renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2023
Resolved
Each portable extinguisher must be of an approved type. CG approval only valid if used with approved bracket. 02 extinguishers do not have approved brackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 9 June 2023
Resolution: Brackets replaced with approved brackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 December 2022
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Holding tank discharge valve does not close completely. Rectify to satisfaction of attending inspector prior to floating vessel.
Action required: 705 - Other - as specified
Resolved 25 April 2023
Resolution: Valve rebuilt and functioning as required.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 May 2022
Resolved
Owner allowed COI to lapse on 07MAY2022.
46CFR176.100(a): A vessel to which this subchapter applies (T) may not be operated without having on board a valid US Coast Guard Certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2022
Resolved 24 May 2022
Resolution: Issued COI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 July 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. GRANITE STATE currently only has 108 serviceable adult life jackets. Total persons on board limited to 108 until additional life jackets provided.
Action required: 705 - Other - as specified
Resolved 25 May 2022
Resolution: Reduced Pax count to 108
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 July 2020
Resolved
Each vessel constructed of wood certificated to operate on a limited coastwise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Due to passenger count restrictions as a result of COVID-19 pandemic,GRANITE STATE has removed 1 of the 6 life floats on board, leaving a remaining capacity of 108. If continuing to operate with reduced life floats during cold water months, total persons on board must be limited to 108.
Action required: 705 - Other - as specified
Resolved 25 May 2022
Resolution: Reduced pax count to 108
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 30 July 2020
Resolved
For alternating-current generators a means for measuring frequency shall also be provided. GRANITE STATE does not have a serviceable means for measuring frequency on AC generator.
46 CFR 183.10-5(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2020
Resolved 20 August 2020
Resolution: Frequency gauge installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 July 2020
Resolved
A submersible electric bilge pump may be used as a power
bilge pump, provided that a positive shutoff valve is installed at the hull penetration. On GRANITE STATE, 2 submersible electric bilge pump discharge lines not fitted with positive shutoff valve at penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2020
Resolved 20 August 2020
Resolution: Valves installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2017
Resolved
Provide ammonia inhalants
Due 19 May 2017
Resolved 15 May 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 May 2017
Resolved
Provide Coast Pilot
Due 19 May 2017
Resolved 15 May 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 May 2016
Resolved
Provide current Light List and Coast Pilot
Due 6 June 2016
Resolved 25 May 2016
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 23 May 2016
Resolved
Broken cables on rescue ladder
Due 6 June 2016
Resolved 8 June 2016