MAURY USCG vessel records Sign in
← All vessels

SOUND BOUND PRINCESS

SOUND BOUND PRINCESS is a 1982 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1985, most recently in July 2025, along with 132 deficiencies, 1 operational control and 1 casualty investigation in 2009.

Records from 1985 to 2025. Most recent: inspection, 14 July 2025.

Built
1982
Last inspected
14 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP4929
Flag
UNITED STATES
368000170
Maury page id
psix-54493

Inspections, by type

…with no type recorded11
Years with a record 37 calendar years (1985–2025)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)85.0 ft × 21.7 ft × 7.4 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1982
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 4 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Net Ton
87 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4929MMSI 368000170 · active · compulsorily equipped · granted 23 March 2024, expires 23 March 2034
WDJ6784MMSI 368000170 · cancelled · compulsorily equipped · granted 25 July 2017, cancelled 20 March 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDC5326MMSI 367039450 · expired · compulsorily equipped · granted 5 May 2005, cancelled 11 July 2015
WBI3458MMSI not assigned · expired · compulsorily equipped · granted 20 March 1997, cancelled 1 September 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 88

14 July 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8185312
27 February 2025 Construction Oversight · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8085791
28 November 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8040981
2 October 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8012977
18 April 2024 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893697
27 April 2023 In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7677540
21 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7611848
11 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7428452
18 February 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7398459
11 January 2022 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7379112
25 November 2020 Hull Examination · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7101850
24 February 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6914234
23 January 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6613258
19 June 2018 Internal Structural Exam · Damage Survey · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6481410
23 August 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6229792
2 June 2017 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6163681
1 August 2014 DAPI Audit · COI Inspection · Re-Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4937654
4 June 2014 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4892943
12 July 2012 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4375291
13 June 2012 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4341837
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199341
16 December 2010 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3911610
15 October 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3872251
13 September 2010 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3848692
14 January 2010 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3664408
18 December 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3652578
11 February 2009 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3415917
4 November 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3356356
5 May 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3199293
28 March 2007 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2896582
20 June 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2685226
6 June 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2672330
11 May 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2353220
30 August 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2180868
19 July 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2114687
30 March 2004 Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2033976
26 June 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1853828
2 June 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1625582
30 April 2002 Hull Examination · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1611346
7 August 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1070822
30 May 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376611
31 August 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822178
18 May 2000 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421895
22 June 1999 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1077666
3 May 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411914
20 May 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428990
18 May 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 794450
14 May 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1125974
11 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 685628
5 November 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1117812
28 April 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1411568
28 April 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414836
30 April 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1465868
19 April 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446367
11 November 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 3917
20 June 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1187484
5 May 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1182647
5 May 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170254
22 April 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 860238
28 January 1994 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 852166
19 January 1994 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 851431
5 May 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142552
8 July 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1256710
22 May 1992 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257971
23 April 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1259025
23 April 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1224757
15 April 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 898754
13 August 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 909071
24 May 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1211197
17 April 1990 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1218895
20 December 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1237297
12 December 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916405
25 October 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 889630
5 August 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040342
21 April 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1347529
28 April 1988 Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344443
10 November 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1023397
2 October 1987 Drydock Extension
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325627
18 August 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029052
10 August 1987 Plan Review "T" Boat
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1312663
20 May 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1312661
22 April 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017783
10 April 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1002803
4 April 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306503
2 April 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306500
3 December 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293101
10 June 1985 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983345
18 April 1985 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1291304

Deficiency record · 132

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 July 2025 Resolved
(b) A vessel which, complies with requirements in subchater S, must have a stability letter issued by Marine Safety Center. Vessek has no stability letter. Provide stability letter. 46CFR178.210(b)
Action required: 705 - Other - as specified
Resolved 13 January 2026
Resolution: Deficiency updated to reduce passenger count to 93 ILO PTCP. 13JAN2025: Uploaded MSC stability letter. COI reflects 27OCT2025 issuance date accordingly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 November 2024 Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years." Vessel did not complete its next DDX/ISE by its due date of 30NOV2024. Complete a credit DDX/ISE. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2025
Resolution: completed dry dock 16APR25
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 April 2024 Resolved
In addition to meeting the requirements of § 80.1085, ships subject to this section must be provided with:(1) An INMARSAT ship earth station capable of: (i) Transmitting and receiving distress and safety data communications; (ii) Initiating and receiving distress priority calls; (iii) Maintaining watch for shore-to-ship distress alert, including those directed to specifically defined geographical areas; (iv) Transmitting and receiving general radiocommunications, using either radiotelephony or direct-printing telegraphy;" Vessel did not have an operating satellite phone. Restricted to Coastwise route. 47 CFR 80.1091(a)(1)
Action required: 705 - Other - as specified
Resolved 14 July 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 April 2024 Resolved
All... emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR." Move sign from engine room entrance to kitchenette. 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2024 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space prior to release of the extinguishing agent into the space." Automatic shutdown of ventilation did not occur during CO2 simulation. 46 CFR 181.410(b)(10)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Automatic electric submersible pump did not have a visual indicator on the bridge. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Vessel did not properly label fuel shutt-off valves for generator and propulsion engines. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 April 2023 Resolved
Mark escape scuttle and engine room door "EMERGENCY EXIT, KEEP CLEAR" 46 CFR 177.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 October 2024
Resolution: Vessel was sold and moved to SEC NY AOR. Defs were reissued by SECNY.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 April 2023 Resolved
Mark emergency fuel shut off's for generators. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 October 2024
Resolution: Vessel was sold and moved to SEC NY AOR. Defs were reissued by SEC NY under activity 7893697
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2023 Resolved
Distribution panel is dirty and has at least 5 instances of wire nut connections. Make appropriate connections and clean out panel of debris and dust. 46 CFR 183.330
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photo provided showing panel cleaned and wire nut connections removed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 April 2023 Resolved
Provide report that shows engine shutdowns associated with fix fire system have been tested OR test shutdowns in presence of Marine Inspector. 46 CFR 181.410 (b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photo of report provided.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 April 2023 Resolved
Remove oil from engine room bilge. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photo provided showing engine room bilge had been cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2023 Resolved
Clean all battery terminals in engine room. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photos provided showing terminals had been cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2023 Resolved
Troubleshoot and clear code on Microcommander for center engine. 46 CFR 184.620
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 May 2023
Resolution: Photo provided showing no error on microcommander.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2023 Resolved
Clean debris from bilge in tank room. 46 CFR 182.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Photo provided showing bilge had been cleaned.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 April 2023 Resolved
Provide fire and MOB drill logs. Drills conducted during inspection can be used. 46 CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 May 2023
Resolution: Photo of drill logs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2022 Resolved
The fuel filter furthest to the port side of the vsl in the engine room was not clean. Additionally, the flame screen on the starboard fuel filter was missing. Clean port fuel filter and install flame screen on starboard fuel filter. Provide pictures to rectify deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 4 May 2022
Resolution: USCG satisfied with pictures sent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2022 Resolved
Vent ducting for the mechanical ventilation in the engine room was not properly connected. Connect vent ducting to ensure proper operation of mechincal ventilation in the engine room. Provide pictures to rectify deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 18 May 2022
Resolution: Reattended vessel. Properly connected ventilation ducting to engine intake blower motors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 April 2022 Resolved
Fixed fire extinguishing system discharged when USCG Marine Inspectors attended the vsl. Recharge CO2 bottles, correctly connect fixed fire extinguishing system, and provide USCG with report from fire extinguishing company.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2022 Resolved
Masthead light was inoperable and starboard running light was made inoperable during inspection. Replace masthead light and starboard running light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 April 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2022 Resolved
Owner did not show Marine Radio Operator permit. Provide Marine Radio Operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022 Resolved
Vsl did not have updated charts. Provide proof that the vsl has updated charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 4 May 2022
Resolution: USCG satisfied with picture.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2022 Resolved
Vsl did not have alcohol swabs. Provide proof that the vsl has alcohol swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2022 Resolved
The hydrostatic release unit for the EPIRB was marked to expire in 2019. Replace hydrostatic release unit for the EPIRB. Vsl restricted to operate 3nm from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022 Resolved
Vsl had US Coast Pilot 2 at the operating station. Show proof that the vsl has US Coast Pilot 3 since vsl operates in the area covered by US Coast Pilot 3.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 4 May 2022
Resolution: USCG satisfied by picture.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 April 2022 Resolved
The vsl's lifefloats were not properly rigged in regards to the paddle marking, paddle lashing, paddle placement, and how the lifefloats were labeled. Properly outfit and mark lifefloats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 April 2022 Resolved
Bulkhead penetration going from fuel tank space to the engine room was not properly sealed. Properly seal the bulkhead penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 April 2022 Resolved
The marine sanitation device was not properly sealed from accidental discharge. Properly secure overboard discharge valve for the marine sanitation device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2022 Resolved
A portable fire extinguisher was found in the accommodation space below deck that should be near the entrance to the engine room. Relocate portable fire extinguisher to the entrance to the engine room. Add 2A fire extinguisher to second deck accommodation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2022 Resolved
Labels were missing on the distribution panels. Ensure that the location for each breaker are labeled on the distribution panels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 February 2022 Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel went over 2021 annual inspection anniversary date, vessel must be inspected before passengers can be carried. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2022
Resolved 15 April 2022
Resolution: USCG issued Temporary COI to vsl on 15APR2022. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 November 2020 Resolved
Middle fuel tank was noted to be weeping fuel. Fuel tanks will require repair and gauging or replacement (as O/O intends). To be complete prior to carrying passengers. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2021
Resolved 12 July 2021
Resolution: New fuel tanks constructed and installed. Witnessed pnuematic pressure test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2020 Resolved
Draft marks are not present on this boat. Recommended engaging with naval architect for proper placement and that a mock up be done for our inspectors to approve prior to installation. Prior to credit dry dock. 46 CFR 185.602
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2021
Resolved 6 January 2021
Resolution: Verified measurement and placement of draft marks as per stability letter.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 November 2020 Resolved
Area on the aft keel and midship port side at the chine (both look like previous repair attempts on the FRP) needs to be cleaned back for inspection and repaired. Prior to credit dry dock. 46 cfr 176.802
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 January 2021
Resolved 5 January 2021
Resolution: Area was sanded down and repaired with FRP to satisfaction of attending MI during def check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2020 Resolved
Fuel tank vents did not have flame screens. Install proper flame screens. 46 CFR 182.20-35(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 11 April 2022
Resolution: USCG satisfied to clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2020 Resolved
Fuel tanks are not yet set up to be filled from outside the the vessel as they must be filled from the top of the tank inside the space. Route fill pipe to terminate outside the vessel as per 46 CFR 182.20-30(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 11 April 2022
Resolution: USCG satisfied to clear deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2020 Resolved
Vessel does not have permanently affixed draft marks. Make the current sticker markings permanent at next haul out period. 46 CFR 185.602
Action required: 705 - Other - as specified
Due 30 October 2021
Resolved 11 January 2022
Resolution: Vessel made permanent draft marks
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2019 Resolved
Alcohol test strips are expired and have been stored improperly. Purchase new test strips and store as per manufacturers instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 12 February 2019
Resolution: New alcohol strips purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2019 Resolved
Exhaust leaks present in lazz space on piping for center main engine. Repair leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 12 February 2019
Resolution: Exhaust leaks repaired.
Construction/Loadline › Hull › Sheerstrake
Issued 4 June 2014 Resolved
Vessel must investigate, submit findings and a plan proposal for entire bow area, pulpit and starboard side laz shear clamp. Vessel has rot and soaked wood all along deckline, clamp and side shell. See activity narrative for details.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 18 September 2019
Resolution: Resolved in previous drydock activity.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 July 2012 Resolved
Coast Pilot and Light List were expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 July 2012
Resolved 12 July 2012
Resolution: New pubs were purchased.
Communications › Radio Communications › EPIRB
Issued 12 July 2012 Resolved
EPIRB battery was expired/non-functional.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2012
Resolved 12 July 2012
Resolution: New EPIRB was purchased and placed in service.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 July 2012 Resolved
Alcohol test kits were expired. New kits were purchased and placed in service.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 July 2012
Resolved 12 July 2012
Resolution: New kits were purchased.
Stability › Incline Test › General
Issued 1 December 2011 Resolved
Based on the new AAWPP your vessel has been restricted to the following passenger count of 77 Passengers and 3 crew.
Action required: 705 - Other - as specified
Due 15 June 2012
Resolved 1 December 2011
Resolution: Vessel will be issued an ammended stability letter to comply with new AAWPP.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 December 2010 Resolved
Hailing port on Certificate of Documentation does not match hailing port on stern or life rings. Update hailing port with NVDC or change hailing port on stern and liferings.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 4 January 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 December 2010 Resolved
Vessel does not have a COI onboard. Vessel may not operate until a signed COI is issued.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2010
Resolved 4 January 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 October 2010 Resolved
Vessel using household wiring in foward hold for lighting attraction and stereo. Owner to remove and replace with proper marine grade wiring to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 2 November 2010
Resolution: All non-marine grade wiring removed and panel installed on breaker box.
Construction/Loadline › Structures › Deck Plating
Issued 15 October 2010 Resolved
Deck foward of scuttle leading into forepeak. Wood found wasted and rotting due to excessive moisture in space. Crop out and renew to satsfaction of attending marine inspector prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2010
Resolution: Cropped out plywood deck and replaced with new wood. Sistered deck frame due to rot. Rotten wood removed to good wood.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 January 2010 Resolved
Received report that vessel has been seized by the US Marshall Service. Make vessel available for inspection upon returning to service and prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2010
Lifesaving › Lifefloat › Markings
Issued 11 February 2009 Resolved
Lifefloat not properly marked with the vessels name.
Action required: 705 - Other - as specified
Resolved 16 December 2009
Resolution: Vessel does not carry a life float.
Lifesaving › Lifefloat › Not on Board
Issued 4 November 2008 Resolved
Properly Install 4ea 22 pax lifefloats.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2009
Resolution: Lifefloats have been properly installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 November 2008 Resolved
Post emergency broadcast placard in wheel house.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: Emergency Broadcast placard posted as required.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 November 2008 Resolved
Repair upper deck starboard side railing. Screws securing post had stripped and post was loose.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: Wood scarfed in a post base and post was re-secured with stainless steel fasteners. Installation sat.
Lifesaving › Lifebuoys › Not on Board
Issued 4 November 2008 Resolved
Provide life ring buoy on second deck.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: Ring lifebouy installed sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 November 2008 Resolved
Remove all unserviceable Type I lifejackets onboard vessel required to meet passenger capacity and replace with serviceable life jackets sufficient for passenger capacity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: All unservicable PFD''s have been removed. Owner has 141 adult and 16 child sized servicable PFD''s on board.
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 November 2008 Resolved
Post required life jacket donning placards for each type of life jacket.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: Lifejacket donning instructions have been properly posted for each type of lifejacket.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 November 2008 Resolved
Replace wasted shaft flexhose clamps on port main engine.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: Shaft flexhose clamps replaced with new. Install sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 4 November 2008 Resolved
Replace wasted raw water clamps on center main engine.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2009
Resolution: Al wasted clamps replaced with new. Install sat.
Engineering › Bilge Water Management System › Hose
Issued 4 November 2008 Resolved
Double clamp on bilge discharge hose in lazarrette.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2019
Resolution: Laz bilge discharge double clamped as required.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2007 Resolved
Repair hull sheathing and frames IWO hold #1.
Action required: 705 - Other - as specified
Resolved 26 June 2007
Resolution: Replaced all affected areas within #1 hold. Please see narrative for this inspection for details of the repair.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 20 June 2006 Resolved
Make proper repairs to turbo oil feed line on STBD MDE outboard, leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2006
Resolution: New fittling installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 June 2006 Resolved
Replace all chaffed R/W hoses for both generators and properly secure S/W strainers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2006
Resolution: Hoses were replaced, double clamped and strainers properly secured.
Engineering › Lubricating Oil Service System › Hose
Issued 20 June 2006 Resolved
Replace severely chaffed hydraulic drain hose for center marine gear, secure hose from contacting shaft coupler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2006
Resolution: Hose was removed and plug installed.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 20 June 2006 Resolved
Double hose clamp and secure leak on hose for port engine driven pump. Coupling was leaking under pressure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2006
Resolution: Hose was properly secured with double hose clamps.
Construction/Loadline › Penetrations › Gasket
Issued 20 June 2006 Resolved
Seal all bulkhead penetrations below decks from recently removed engine control cables and PVC pipe.
Due 20 July 2006
Resolved 27 July 2006
Resolution: Bulkhead penetrations were sealed.
Communications › Radio Communications › EPIRB
Issued 20 June 2006 Resolved
EPIRB failed funtction test.
Action required: 705 - Other - as specified
Resolved 27 June 2006
Resolution: EPIRB had been replaced and registration renewed.
Engineering › Steering Gear System › Fastener
Issued 20 June 2006 Resolved
Adjust rudder packings- secure leak.
Due 27 July 2006
Resolved 27 June 2006
Resolution: Packing was tightened.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 June 2006 Resolved
Double hose clamp all R/W hoses, MDE exhaust feed.
Due 20 July 2006
Resolved 27 July 2006
Resolution: Double hose clamps installed.
Engineering › Freshwater System (jacketwater cooling) › Level Control
Issued 20 June 2006 Resolved
Replace expansion cap on port MDE, leaking J/W.
Due 20 July 2006
Resolved 27 June 2006
Resolution: Cap renewed.
Lifesaving › Lifefloat › Markings
Issued 19 July 2004 Resolved
Mark out old vessel name/number and replace with new name/number on all five life floats and all paddles for life floats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: All markings corrected during course of annual inspection.
Engineering › Bilge Water Management System › Manifold
Issued 19 July 2004 Resolved
Provide bilge suction manifold labels for valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2004
Resolved 19 July 2004
Resolution: Corrected during course of annual inspection.
Engineering › Steering Gear System › Linkage
Issued 19 July 2004 Resolved
Provide new bolts/pins with double nuts/cotter pin for port and starboard jockey bar linkage. Both bolts/pins for port and starboard jockey bar linkage completely sheared off.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2004
Resolved 27 August 2004
Resolution: Bolts replaced and double nutted.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 July 2004 Resolved
Provide circuit breaker panel blanks in galley circuit breaker.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2004
Resolved 19 July 2004
Resolution: Corrected during course of annual inspection.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 19 July 2004 Resolved
Provide lifejacket donning placards for two different styles of type one lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2004
Resolved 19 July 2004
Resolution: Corrected during course of annual inspection.
Accommodation/Occupational Safety
Issued 26 June 2003 Resolved
MARK UPPER DECK FOR NUMBER OF PASSENGERS PERMITTED, AT TOP OF FORWARD AND AFT LADDERWAYS.
Action required: 705 - Other - as specified
Due 26 July 2003
Resolved 30 September 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 June 2003 Resolved
RENEW RETRO-REFLECTIVE TAPE ON 29 ADULT LIFE JACKETS AND 8 CHILD JACKETS. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 26 July 2003
Resolved 26 June 2003
Resolution: PROVIDED 29 NEW ADULT PFD''S AND 8 NEW CHILD.
Personnel › Training
Issued 30 April 2002 Resolved
PROVIDE FIRST AID AND CPR TRAINING FOR AT LEAST 50% OF THE CREW. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Fire Fighting › Grease Extraction Hood
Issued 30 April 2002 Resolved
PROVIDE SERVICE FOR FIXED FIRE FIGHTING SYSTEM FOR EXTRACTION HOOD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2002
Resolution: SERVICE CONDUCTED.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 April 2002 Resolved
PROVIDE GUARDS FOR EXPOSED HAZARDS FOR BELTS ON FWD SECTION OF MAIN DEISEL ENGINES. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Engineering › Bilge Water Management System
Issued 30 April 2002 Resolved
REPLACE HOSE FOR ELECTRIC BILGE PUMP. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Electrical › Electrical Distribution System (service)
Issued 30 April 2002 Resolved
SUPPORT WIRE RUN IN FUEL TANKS SPACE WITH SUPPORTS NOT MORE THAN 24" APART. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Electrical › Electric Supply System (service)
Issued 30 April 2002 Resolved
LINE BATTERY BOXES WITH LEAD, FIBERGLASS, OR EPOXY. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Fire Fighting › Structural Fire Protection - General
Issued 30 April 2002 Resolved
SEAL HOSE AND WIRE RUN PENETRATIONS IN FWD AND AFT MACHINERY SPACE BULKHEADS USING FIRE RETARDANT FILLER. LEGACY COMPONENT DESC: Structural Bulkhead Construction
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Electrical › Electric Generation Source (service)
Issued 30 April 2002 Resolved
REPLACE RAW WATER INTAKE HOSE. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 30 May 2002
Resolved 9 May 2002
Engineering › Sea-water System (primary cooling)
Issued 30 April 2002 Resolved
REPLACE BOTH RAW WATER INTAKE GATE VALVES FOR PORT AND STBD ENGINE. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 9 May 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 April 2002 Resolved
PROVIDE TWO TYPE I ADULT PFD'S LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2002
Engineering › Steering Gear System
Issued 30 April 2002 Resolved
RUDDER POST LEAKING EXCESSIVELY. READJUST PACKING NOTIFY CG INSPECTOR UPON PROPER REPAIRS. LEGACY COMPONENT DESC: Rudder Bearing
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 2 June 2002
Engineering › Sea-water System (primary cooling)
Issued 30 April 2002 Resolved
REPAIR LEAK IN STAINLESS STEEL EXHAUST ELBOW FOR STBD MAIN ENGINE. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 2 June 2002
Resolution: COMPLETED REPAIRS IN STAINLESS ELBOW, REPAIR SAT.
Lifesaving › Buoyant Apparatus
Issued 30 April 2002 Resolved
PROVIDE SEA PAINTER AND WEAK LINK FOR LIFE FLOATS iaw 46CFR 180.130.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2002
Construction/Loadline › Hull
Issued 30 April 2002 Resolved
AT NEXT ANNUAL INSPECTION, AND AT CREDIT DRYDOCK, CONDUCT FURTHER EXAMINATION OF ROT TO INTERIOR PLANKING IN FOREPEAK TO DETERMINE EXTENT OF ANY REPAIR WORK REQUIRED FOR CREDIT DRYDOCKING. LEGACY COMPONENT DESC: Hull Planking
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 14 April 2004
Resolution: See activity 2033976.
Construction/Loadline › Hull
Issued 30 April 2002 Resolved
AT NEXT DRYDOCK REMOVE PANELING/CEILINGS FROM INTERIOR SIDE SHELL AS REQUIRED BY COAST GUARD MARINE INSPECTOR TO PERMIT ACCESS TO THE HULL FOR INSPECTION PER 46 CFR 176.610(b). LEGACY COMPONENT DESC: Ceilings
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 14 April 2004
Resolution: See activity 2033976.
Lifesaving
Issued 30 May 2001 Resolved
MAKE REPAIRS TO LIFE RING BUOYS.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Engineering
Issued 30 May 2001 Resolved
INSTALL FLAME IMPINGEMENT BOWL ON GENERATOR RAYCOR FUEL OIL FILTER
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Lifesaving
Issued 30 May 2001 Resolved
MAKE REPAIRS TO STBD UPPER LIFE FLOAT. SUN DETERIORATION HAS EATEN THROUGH AND NEEDS TO BE ARRESTED.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Construction/Loadline
Issued 30 May 2001 Resolved
REPLACE FLEX HOSE ON BILGE PUMP ON PORT ENGINE WITH WIRE REINFORCED HOSE.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Engineering
Issued 30 May 2001 Resolved
MAKE REPAIRS TO GENERATOR EXHAUST HOSE. AN AREA IN LAZARETTE IS CHAFING AGAINST WOODEN FRAME AND SHOWS INDICATION OF SALT WATER LEAK.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Fire Fighting
Issued 18 May 2000 Resolved
INSTALL GRIDDLE GREASE EXTRACTION VENT HOOD IN GALLEY IAW 46CFR181.400(d), 181.425 AND .450. INSTALLATION IS TO BE COMPLETED NOT LATER THAN 30JUN00. APROPOSAL IS TO BE SUBMITTED TO MSO TAMPA NOT LATER THAN 15JUN00. EACH MASTER IS REQUIRED TO SET FIRE WATCH AT ALL TIMES GRIDDLE IS IN USE.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Fire Fighting
Issued 18 May 2000 Resolved
BRING INSTALLED FIRE PUMP INTO COMPLIANCE WITH 46CFR181.300.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Documentation
Issued 5 November 1997 Resolved
PAY USER FEE
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Documentation
Issued 28 April 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997
Lifesaving
Issued 30 April 1996 Resolved
REPAINT FLARE BOX EITHER RED OR ORANGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1996
Resolved 30 May 1996
Accommodation/Occupational Safety
Issued 30 April 1996 Resolved
LABEL CAPACITY OF UPPER DECK 36 PERSONS MAXIMUM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1996
Resolved 30 May 1996
Lifesaving
Issued 30 April 1996 Resolved
LABEL FLARE BOX "DISTRESS SIGNALS."_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1996
Resolved 30 May 1996
Navigation
Issued 5 May 1995 Resolved
Repair and properly wire starboard navigation light prior to operating.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Fire Fighting
Issued 5 May 1995 Resolved
Renew deteriorated fittings on both fire stations from the vave to the hose.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Fire Fighting
Issued 5 May 1995 Resolved
Label both fire stations.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Fire Fighting
Issued 5 May 1995 Resolved
Install approved 50 foot fire hose at fire station #2 prior to carrying passengers.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Fire Fighting
Issued 5 May 1995 Resolved
Permanently connect both fire hoses prior to carrying passengers.
Condition: Unknown
Due 24 May 1995
Resolved 24 May 1995
Lifesaving
Issued 5 May 1995 Resolved
Renew beckett lines on all lifefloats.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Accommodation/Occupational Safety
Issued 5 May 1995 Resolved
Renew cracked window glass in captains cabing port and starboard sides.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Engineering
Issued 5 May 1995 Resolved
Insulate turbo chargers on starboard and center engines.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Engineering
Issued 5 May 1995 Resolved
Install guard on front of starboard main engine.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Construction/Loadline
Issued 5 May 1995 Resolved
Label bilge manifold.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Accommodation/Occupational Safety
Issued 22 May 1992 Resolved
Close in spaces between railing courses on upper deck.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Lifesaving
Issued 15 April 1991 Resolved
MARK VESSEL NAME AND CAPACITY ON TOP AND BOTTOM OF EACH LIFEFLOAT.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Electrical
Issued 15 April 1991 Resolved
REMOVE ALL DEAD END ELECTRICAL WIRES THROUGHOUT THE VESSEL (WHEEL HOUSE,_x001C_ CONSOLE, ENGINEROOM, #1 FWD COMPT AND MAIN DECK FISH BOX AERATORS).
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Navigation
Issued 15 April 1991 Resolved
INSTALL BLACK SCREEN AROUND STERN LIGHT IAW INTERNATIONAL COLREGS.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Documentation
Issued 15 April 1991 Resolved
PREPARE AND POST WRITTEN WASTE MANAGEMENT PLAN (MARPOL V).
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Lifesaving
Issued 15 April 1991 Resolved
ATTACH WATER LIGHTS TO EACH LIFEFLOAT AND MARK VESSEL NAME ON LIGHTS.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Lifesaving
Issued 15 April 1991 Resolved
MARK VESSEL NAME ON PADDLES.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Lifesaving
Issued 15 April 1991 Resolved
REPLACE LIFELINE ATTACHMENTS ON EACH LIFEFLOAT.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Lifesaving
Issued 15 April 1991 Resolved
REPLACE NET TO FLOAT ATTACHMENT LINES ON LIFEFLOATS 1, 3, AND 4.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Navigation
Issued 15 April 1991 Resolved
REPLACE OUT OF DATE BATTERY ON EPIRB.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Lifesaving
Issued 17 April 1990 Resolved
REPLACE LIFEFLOAT AND FLOAT FREE LINK.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Electrical
Issued 17 April 1990 Resolved
REPLACE PROTECTIVE SCREENS ON LIGHTING FIXTURES IN ENGINEROOM AND LIGHT BULV IN EMERGENCY LIGHT PORT SIDE FWD CABIN.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Electrical
Issued 17 April 1990 Resolved
REPLACE SAFETY GUARDS ON THE PORT AND STBD GENERATOR V-BELT DRIVES.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Electrical
Issued 17 April 1990 Resolved
REPLACE SPRAY SHIELDS ON RAYCOR FUEL OIL FILTERS FOR BOTH SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Engineering
Issued 17 April 1990 Resolved
REPLACE SAFETY GUARDS ON STBD AND CENTER MAIN ENGINE PULLEY AND V-BELT DRIVES.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Electrical
Issued 10 April 1987 Resolved
PROVE OPERATION OF STBD GENERATOR UNDER LOAD.
Condition: Unknown
Due 10 April 1987
Resolved 10 April 1987
Lifesaving
Issued 10 April 1987 Resolved
PROVIDE 5 ADULT TYPE I PFD'S. VESSEL IS RESTRICTED TO 145 TOTAL PERSONS UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 10 April 1987
Resolved 10 April 1987
Electrical
Issued 10 April 1987 Resolved
DEMONSTRATE OPERATION OF ELECTRIC BILGE PUMP.
Condition: Unknown
Due 10 April 1987
Resolved 10 April 1987

Casualty record · 1

24 October 2009Routine · role: Involved in a Marine Casualty · activity 3630482
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TROPICAL ADVENTURE (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record