MAURY USCG vessel records
← All vessels

SOUND BOUND PRINCESS

Built
1982
Last inspected
14 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 July 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4929
Flag
UNITED STATES
Maury page id
psix-54493

Documentation record

Registered dimensions (L × B × D)85.0 ft × 21.7 ft × 7.4 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1982
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 4 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Regulatory (Subpart C or D), Net Ton
87 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

14 July 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8185312
27 February 2025 Construction Oversight · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8085791
28 November 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8040981
2 October 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8012977
18 April 2024 COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893697
27 April 2023 In-Service Inspection · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7677540
21 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7611848
11 April 2022 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7428452
18 February 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7398459
11 January 2022 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7379112
25 November 2020 Hull Examination · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7101850
24 February 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6914234
23 January 2019 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6613258
19 June 2018 Internal Structural Exam · Damage Survey · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6481410
23 August 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6229792
2 June 2017 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6163681

Deficiency record · 40

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 July 2025 Resolved
(b) A vessel which, complies with requirements in subchater S, must have a stability letter issued by Marine Safety Center. Vessek has no stability letter. Provide stability letter. 46CFR178.210(b)
Action required: 705 - Other - as specified
Resolved 13 January 2026
Resolution: Deficiency updated to reduce passenger count to 93 ILO PTCP. 13JAN2025: Uploaded MSC stability letter. COI reflects 27OCT2025 issuance date accordingly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 November 2024 Resolved
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years." Vessel did not complete its next DDX/ISE by its due date of 30NOV2024. Complete a credit DDX/ISE. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2025
Resolution: completed dry dock 16APR25
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 April 2024 Resolved
In addition to meeting the requirements of § 80.1085, ships subject to this section must be provided with:(1) An INMARSAT ship earth station capable of: (i) Transmitting and receiving distress and safety data communications; (ii) Initiating and receiving distress priority calls; (iii) Maintaining watch for shore-to-ship distress alert, including those directed to specifically defined geographical areas; (iv) Transmitting and receiving general radiocommunications, using either radiotelephony or direct-printing telegraphy;" Vessel did not have an operating satellite phone. Restricted to Coastwise route. 47 CFR 80.1091(a)(1)
Action required: 705 - Other - as specified
Resolved 14 July 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 April 2024 Resolved
All... emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR." Move sign from engine room entrance to kitchenette. 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2024 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space prior to release of the extinguishing agent into the space." Automatic shutdown of ventilation did not occur during CO2 simulation. 46 CFR 181.410(b)(10)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Automatic electric submersible pump did not have a visual indicator on the bridge. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Vessel did not properly label fuel shutt-off valves for generator and propulsion engines. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 April 2023 Resolved
Mark escape scuttle and engine room door "EMERGENCY EXIT, KEEP CLEAR" 46 CFR 177.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 October 2024
Resolution: Vessel was sold and moved to SEC NY AOR. Defs were reissued by SECNY.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 April 2023 Resolved
Mark emergency fuel shut off's for generators. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 October 2024
Resolution: Vessel was sold and moved to SEC NY AOR. Defs were reissued by SEC NY under activity 7893697
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2023 Resolved
Distribution panel is dirty and has at least 5 instances of wire nut connections. Make appropriate connections and clean out panel of debris and dust. 46 CFR 183.330
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photo provided showing panel cleaned and wire nut connections removed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 April 2023 Resolved
Provide report that shows engine shutdowns associated with fix fire system have been tested OR test shutdowns in presence of Marine Inspector. 46 CFR 181.410 (b)(10)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photo of report provided.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 April 2023 Resolved
Remove oil from engine room bilge. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photo provided showing engine room bilge had been cleaned.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 April 2023 Resolved
Clean all battery terminals in engine room. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Photos provided showing terminals had been cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 April 2023 Resolved
Troubleshoot and clear code on Microcommander for center engine. 46 CFR 184.620
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 May 2023
Resolution: Photo provided showing no error on microcommander.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2023 Resolved
Clean debris from bilge in tank room. 46 CFR 182.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2023
Resolution: Photo provided showing bilge had been cleaned.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 April 2023 Resolved
Provide fire and MOB drill logs. Drills conducted during inspection can be used. 46 CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2023
Resolved 2 May 2023
Resolution: Photo of drill logs provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2022 Resolved
The fuel filter furthest to the port side of the vsl in the engine room was not clean. Additionally, the flame screen on the starboard fuel filter was missing. Clean port fuel filter and install flame screen on starboard fuel filter. Provide pictures to rectify deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 4 May 2022
Resolution: USCG satisfied with pictures sent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2022 Resolved
Vent ducting for the mechanical ventilation in the engine room was not properly connected. Connect vent ducting to ensure proper operation of mechincal ventilation in the engine room. Provide pictures to rectify deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 18 May 2022
Resolution: Reattended vessel. Properly connected ventilation ducting to engine intake blower motors.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 April 2022 Resolved
Fixed fire extinguishing system discharged when USCG Marine Inspectors attended the vsl. Recharge CO2 bottles, correctly connect fixed fire extinguishing system, and provide USCG with report from fire extinguishing company.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2022 Resolved
Masthead light was inoperable and starboard running light was made inoperable during inspection. Replace masthead light and starboard running light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 April 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2022 Resolved
Owner did not show Marine Radio Operator permit. Provide Marine Radio Operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022 Resolved
Vsl did not have updated charts. Provide proof that the vsl has updated charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 4 May 2022
Resolution: USCG satisfied with picture.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 April 2022 Resolved
Vsl did not have alcohol swabs. Provide proof that the vsl has alcohol swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2022 Resolved
The hydrostatic release unit for the EPIRB was marked to expire in 2019. Replace hydrostatic release unit for the EPIRB. Vsl restricted to operate 3nm from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 April 2022 Resolved
Vsl had US Coast Pilot 2 at the operating station. Show proof that the vsl has US Coast Pilot 3 since vsl operates in the area covered by US Coast Pilot 3.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 4 May 2022
Resolution: USCG satisfied by picture.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 April 2022 Resolved
The vsl's lifefloats were not properly rigged in regards to the paddle marking, paddle lashing, paddle placement, and how the lifefloats were labeled. Properly outfit and mark lifefloats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 April 2022 Resolved
Bulkhead penetration going from fuel tank space to the engine room was not properly sealed. Properly seal the bulkhead penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 April 2022 Resolved
The marine sanitation device was not properly sealed from accidental discharge. Properly secure overboard discharge valve for the marine sanitation device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 April 2022 Resolved
A portable fire extinguisher was found in the accommodation space below deck that should be near the entrance to the engine room. Relocate portable fire extinguisher to the entrance to the engine room. Add 2A fire extinguisher to second deck accommodation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2022 Resolved
Labels were missing on the distribution panels. Ensure that the location for each breaker are labeled on the distribution panels.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2022
Resolved 15 April 2022
Resolution: USCG satisfied to clear deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 February 2022 Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel went over 2021 annual inspection anniversary date, vessel must be inspected before passengers can be carried. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2022
Resolved 15 April 2022
Resolution: USCG issued Temporary COI to vsl on 15APR2022. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 25 November 2020 Resolved
Middle fuel tank was noted to be weeping fuel. Fuel tanks will require repair and gauging or replacement (as O/O intends). To be complete prior to carrying passengers. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2021
Resolved 12 July 2021
Resolution: New fuel tanks constructed and installed. Witnessed pnuematic pressure test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2020 Resolved
Draft marks are not present on this boat. Recommended engaging with naval architect for proper placement and that a mock up be done for our inspectors to approve prior to installation. Prior to credit dry dock. 46 CFR 185.602
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 January 2021
Resolved 6 January 2021
Resolution: Verified measurement and placement of draft marks as per stability letter.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 November 2020 Resolved
Area on the aft keel and midship port side at the chine (both look like previous repair attempts on the FRP) needs to be cleaned back for inspection and repaired. Prior to credit dry dock. 46 cfr 176.802
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 January 2021
Resolved 5 January 2021
Resolution: Area was sanded down and repaired with FRP to satisfaction of attending MI during def check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2020 Resolved
Fuel tank vents did not have flame screens. Install proper flame screens. 46 CFR 182.20-35(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 11 April 2022
Resolution: USCG satisfied to clear deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 November 2020 Resolved
Fuel tanks are not yet set up to be filled from outside the the vessel as they must be filled from the top of the tank inside the space. Route fill pipe to terminate outside the vessel as per 46 CFR 182.20-30(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2021
Resolved 11 April 2022
Resolution: USCG satisfied to clear deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 November 2020 Resolved
Vessel does not have permanently affixed draft marks. Make the current sticker markings permanent at next haul out period. 46 CFR 185.602
Action required: 705 - Other - as specified
Due 30 October 2021
Resolved 11 January 2022
Resolution: Vessel made permanent draft marks
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2019 Resolved
Alcohol test strips are expired and have been stored improperly. Purchase new test strips and store as per manufacturers instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 12 February 2019
Resolution: New alcohol strips purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2019 Resolved
Exhaust leaks present in lazz space on piping for center main engine. Repair leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 12 February 2019
Resolution: Exhaust leaks repaired.

Recorded names · 1

TROPICAL ADVENTURE (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.