← All vessels
TRITON EXPLORER
TRITON EXPLORER is a 1970 industrial vessel. The Coast Guard has recorded 78 inspections since 1985, most recently in June 2016, along with 104 deficiencies and 3 casualty investigations between 2005 and 2011.
Records from 1985 to 2016. Most recent: inspection, 20 June 2016.
- Built
- 1970
- Last inspected
- 20 June 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 104 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2005–2011
Identity
527280
7029043 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG9591
54511
Flag
UNITED STATES
338476000, 368059000 (licence lapsed)
Maury page id
psix-54511
Inspections, by type
…with no type recorded14
Years with a record
26 calendar years (1985–2016)
The 78 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Tonnage as PSIX records it989 - Regulatory (Subpart C or D), Gross Ton
673 - Regulatory (Subpart C or D), Net Ton
344 - Convention (Subpart B), Net Ton
1147 - Convention (Subpart B), Gross Ton
673 - Regulatory (Subpart C or D), Net Ton
344 - Convention (Subpart B), Net Ton
1147 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDG9591MMSI 368059000 · expired · compulsorily equipped · granted 7 September 2013, cancelled 11 November 2023
WDE2903MMSI 368059000 · cancelled · compulsorily equipped · granted 12 January 2008, cancelled 20 August 2013
WBP2593MMSI 338476000 · cancelled · compulsorily equipped · granted 20 February 2004, cancelled 28 February 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 78
20 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5913038
23 March 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5838912
26 October 2010
Annual Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3872805
15 September 2008
Hull Examination · Administrative Inspection · Examination of Repairs · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3325567
19 February 2008
COI Inspection · Administrative Inspection · MTSA/ISPS Verification · Commercial Dive Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3149837
25 January 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3136182
7 December 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3111395
30 May 2007
MTSA/ISPS Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2946653
27 September 2006
Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2788274
17 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2750535
17 May 2006
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2651540
1 December 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2544765
29 July 2005
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2444284
27 May 2005
In-Service Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2418463
15 April 2005
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2337109
12 April 2005
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2331954
18 June 2004
MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2102934
18 May 2004
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2078356
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2013586
21 November 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1953504
3 November 2003
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1941318
23 April 2003
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1746600
19 February 2003
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1746607
2 May 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1611870
12 April 2002
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1604018
2 April 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1600005
24 January 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1481058
4 January 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1475827
16 November 2001
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1076139
15 June 2001
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1387156
25 October 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430932
16 June 2000
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361546
15 June 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1050607
28 March 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1395494
16 March 2000
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361366
6 February 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 12866
1 February 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 814438
5 January 2000
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1462050
6 December 1999
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416996
3 December 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404880
31 August 1999
Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386586
25 November 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 686717
16 November 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 114649
23 September 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1466562
13 May 1998
Excursion Permit
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1381235
3 April 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1413338
10 September 1997
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1364359
6 August 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1445245
15 May 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 774567
6 November 1996
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360659
28 September 1995
COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355463
28 March 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 829637
30 November 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 870849
9 November 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1382867
14 February 1994
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 856403
17 September 1993
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 841226
30 October 1992
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 932913
1 October 1992
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1134206
30 July 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1261482
17 September 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 942380
16 April 1991
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1222675
27 March 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 902971
19 March 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 926727
5 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1240823
20 February 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229555
18 June 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 921496
10 March 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 931630
17 November 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1220213
23 September 1989
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1208914
23 September 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1308985
3 August 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1346138
7 July 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897540
2 June 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1196955
8 July 1987
Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1321717
19 February 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1321876
9 May 1986
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996799
1 May 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1000171
23 May 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1286165
Deficiency record · 104
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 March 2016
Resolved
Life buoy line needs replacing due weather conditions
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 23 March 2016
Resolved
emergancy lighting located on the bridge and dive shop was not working
Lifesaving › Rescue Boat › Construction
Issued 23 March 2016
Resolved
Rescue boat does not meet the Coast Guard approval under 46 CFR sub-chapter w
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 March 2016
Resolved
Liferafts did not have proper hydro-static releases expiration dates .
Lifesaving › Launching Appliances › Davit
Issued 3 December 2008
Resolved
Provide Dedicated Launching Appliance for Rescue Boat
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 3 December 2008
Resolved
Emergency Generator is manually switched over. Provide Transitional emergency power to the following areas. 1) Lighting at liferaft debarkation area 2) Install PA on battery backup 3) Install emergency lighting at Emergency Generator Station.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 December 2008
Resolved
Provide Guard for LARS Winch
Stability › Unintentional Flooding › General
Issued 3 December 2008
Resolved
Stencil Cargo Hatches "Do Not Open While Vessel is at Sea"
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 3 December 2008
Resolved
Install 1 barrel fuel containment at fueling station
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 December 2008
Resolved
Provide Emergency F/O Shut off for F/O Transfer Station
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 3 December 2008
Resolved
Incorporate F/O Transfer Procedures to include filling of Deck Equipment.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 19 February 2008
Resolved
Replace portable quarter units (2) with approved units. Notify Coast Guard when units are removed and replaced.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 19 February 2008
Resolved
Provide ABS approved addendum to the stability booklet. Complete prior to an oceans voyage.
Construction/Loadline › Structures › Deck Plating
Issued 19 February 2008
Resolved
Provide proof test to aft A frame.
Construction/Loadline › Structures › Deck Plating
Issued 19 February 2008
Resolved
Provide ABS approval of Starboard side A frame installation.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 February 2008
Resolved
Provide approved palns for bulkhead modifications.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 19 February 2008
Resolved
Provide automation test procedures IAW 46CFR61.40-10.
Construction/Loadline › Structures › Door
Issued 19 February 2008
Resolved
Replace watertight doors in engine room with quick acting doors as required by 46CFR174.210.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 June 2007
Resolved
OWS needs to be repaired to like new condition.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 June 2007
Resolved
Fire and safety plan did not match equiptment on ship.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 September 2006
Resolved
Provide approved fire control planin accordance with 46CFR97.36-1(a)
Construction/Loadline › Structures › Scuttle
Issued 17 May 2006
Resolved
Repair water tight door gaskets as discussed.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 17 May 2006
Resolved
Renew all life line on life rings, lights and smoke floats w/ uv resistant line.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 17 May 2006
Resolved
Renew SOLAS reflective tape on life rings.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2006
Resolved
Replace nav lights with vertical filiment.
Lifesaving › Liferaft Equipment › Instructions (immediate action)
Issued 17 May 2006
Resolved
Post life-raft placard.
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 17 May 2006
Resolved
Install propeller guard on rescue boat
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 17 May 2006
Resolved
Provide line throwing appliances
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 17 May 2006
Resolved
Provide approved stamped fire plan
Fire Fighting › Firemans Outfit › Quantity
Issued 17 May 2006
Resolved
Provide spare flash light batteries for fire mans outfit
Fire Fighting › Fire Hoses › Material
Issued 17 May 2006
Resolved
Provide UL approved fire hoses.
Engineering › Reduction Gearing/Clutches › Gear
Issued 17 May 2006
Resolved
Install exhaust blankets on winch motors.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 May 2006
Resolved
Renew light covers as discussed
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 17 May 2006
Resolved
Provide and install approved electrical mat at main switchboard.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 17 May 2006
Resolved
Store all paint in paint locker not in bos'n locker
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 May 2006
Resolved
Label location of stove disconnect at stove
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 May 2006
Resolved
Remove plastic trashcans from engineering spaces and replace with metal cans
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 May 2006
Resolved
Provide ASME certification for all pressure vessels on board
Engineering › Fuel Oil Service System › Hose
Issued 17 May 2006
Resolved
Renew fuel oil hoses meeting CFR for generators on helo deck.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 17 May 2006
Resolved
Provide and isntall 2 B- 11 fire extinguishers in vicinty of generators on helo deck.
Stability › Incline Test › General
Issued 17 May 2006
Resolved
Provide updated stability booklet to account for /allow deck cargo above main deck on helo deck including portable accommodations and generators.
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 May 2005
Resolved
The coating system has failed in way of #1 forepeak make-up potable water tank, center service tank and #3 centerline aft make-up tank. Tanks must be taken to bare metal and recoated IAW 21 CFR 175.300 prior to being used for potable water. Tank must be inspected before and after coating system has been applied, and approved by a CG Marine Inspector prior to tank being put back into service.
Lifesaving › Lifejacket/PFD (General)
Issued 23 April 2003
Resolved
Properly label all lifejacket stowage locations in accordance with 46 CFR 199.70(b)(a)(ii)
Lifesaving
Issued 23 April 2003
Resolved
renew retroreflective tape on 3 lifejackets and 2 ringbuoys.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 23 April 2003
Resolved
Perform calibration test on OWS oil content meter and submit calibration report to attending inspector.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 April 2003
Resolved
Remove all "SO" cable to chill boxes under helo deck.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 23 April 2003
Resolved
Submit required documentation dor divers air pressure receiver as required by 46 CFR 54.01-5(c)(3).
Engineering
Issued 23 April 2003
Resolved
Restore main engine low lube oil shut down device as original.
Pollution Prevention/Response
Issued 23 April 2003
Resolved
Correct discrepancies to oil record book and display to attending marine inspector.
Engineering
Issued 23 April 2003
Resolved
Repair as new main propulsion monitoring system emergency electrical back up. Vessel must fully man engineroom when the vessel is underway or the machinery plant is operational.
Engineering
Issued 23 April 2003
Resolved
Provide proof machinery automation system meets the design verification requirements listed in 46 CFR 61.40-1. Vessel must fully man engineroom when the vessel is underway or the machinery plant is operational.
Engineering
Issued 23 April 2003
Resolved
Install personnel alarm as required by 46 CFR 62.50-20(b). Vessel must fully man engineroom when the vessel is underway or the machinery plant is operational.
Engineering
Issued 23 April 2003
Resolved
Provide machinery needs assistance alarm as required by 46 CFR 62.50-30(e). Vessel must fully man engineroom when the vessel is underway or the machinery plant is operational.
Engineering
Issued 23 April 2003
Resolved
Add MPMS summary display in the Chief engineers stateroom as required by 46 CFR 62.50-30(f). Vessel must fully man engineroom when the vessel is underway or the machinery plant is operational.
Pollution Prevention/Response › Prevention Equipment
Issued 12 April 2002
Resolved
Prove proper operation of the oily water separator and oil content meter. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 April 2002
Resolved
Prove proper operation of the Port Main Diesel Engine shut down from the pilot house.
Electrical › Electric Generation Source (service)
Issued 12 April 2002
Resolved
Provide and install generator data plates for the port and stbd ship service generators.
Construction/Loadline › Hull › Weld
Issued 2 April 2002
Resolved
Gouge and reweld approximately 15 linear feet of washed out hull welds I.W.O. the vessels stem and side hull plate.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 April 2002
Resolved
Repair approximately 12" of tailshaft coating, aft of the stern tube bearing sleeve, after spark test revealed damaged coatings.
Engineering › Bilge Water Management System › Piping
Issued 2 April 2002
Resolved
Renew the O.W.S. overboard spool piece.
Engineering › Bilge Water Management System › Valve
Issued 2 April 2002
Resolved
Open and make ready for inspection the emergency bilge suction valve.
Engineering › Bilge Water Management System › Strainer
Issued 2 April 2002
Resolved
Renew emergency bilge suction valve strainer.
Engineering › Bilge Water Management System
Issued 2 April 2002
Resolved
Remove excess bilge slops from the machinery space bilges.
Construction/Loadline
Issued 15 June 2001
Resolved
Provide an operational oil water separator.
Electrical
Issued 15 June 2001
Resolved
Provide an emergency source of power for the engineering automation system as per the MSC letter dated 31May01 note 4. The vessel may not sail until this requirement is corrected to the satisfaction of the cognizant OCMI.
Documentation
Issued 15 June 2001
Resolved
Complete an inspection for certification prior to operating.
Unknown
Issued 25 October 2000
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF THE OWS MONITOR.
Engineering
Issued 25 October 2000
Resolved
CONDUCT OVERSPEED, LOW LUBE OIL AND HIGH JACKET WATER TEST ON STBD MAIN ENGINE.
Construction/Loadline
Issued 16 March 2000
Resolved
Repair cracks in 2 upper brackets, forward transverse bulkhead in #2 ballast tank at next drydock to the satisfaction of the attending marine inspector.
Construction/Loadline
Issued 16 March 2000
Resolved
Make permanent repairs to all areas that exceed maximum allowable wastage as identified in guaging report dated January 6, 7, and 10, 2000 at next drydock to the satisfaction of attending marine inspector.
Construction/Loadline
Issued 16 March 2000
Resolved
Renew wasted web frame (frame has an area that is wasted through) in #3 ballast tank at next dryodck.
Electrical
Issued 5 January 2000
Resolved
Provide an electrical plan for the new air conditioning system being installed on the vessel. The plan should include a single line electical diagram, material & equipment list and a load analysis. Aproval of the system must be received before system may be energized.
Navigation
Issued 31 August 1999
Resolved
Provide vessel with a maneuvering fact sheet as per 33 CFR 164.35.
Engineering
Issued 31 August 1999
Resolved
Demonstrate proper operation of the low control air pressure alarm. This item must be corrected before vessel operates.
Fire Fighting
Issued 31 August 1999
Resolved
Provide written procedures for operation of the emergency fire pump(s) to include designated pump and pump location.
Lifesaving
Issued 31 August 1999
Resolved
Provide a properly sized relief valve for the control air system air receiver and demonstrate proper operation of the relief valve. This must be provided before vessel operates.
Engineering
Issued 31 August 1999
Resolved
Repair wasted engine room vent ducting on both port and starboard vent fans.
Navigation
Issued 31 August 1999
Resolved
Show proper operation of the navigation lights and lights associated with helo operations upon loss of power as per 46 CFR 112.15._x001C_ _x001C_ _x001C_
Engineering
Issued 31 August 1999
Resolved
Provide an approved Vital Systems Automation Test Procedure updated to include the equipment and systems currently installed on the vessel.
Lifesaving
Issued 31 August 1999
Resolved
Provide properly sized relief valves for all 4 salvage winch air receivers and demonstrate proper operating of the relief valves. This item must be completed prior to vessel operation.
Accommodation/Occupational Safety
Issued 31 August 1999
Resolved
Provide an adequate supply of chemical for the MSD system. This item must be corrected prior to vessel operation.
Electrical
Issued 31 August 1999
Resolved
Hard wire the air drier in the CO2 bottle space.
Documentation
Issued 23 September 1998
Resolved
PROVIDE WORKING COPY OF OIL RECORD BOOK
Fire Fighting
Issued 23 September 1998
Resolved
HAVE SCBA BOTTLES HYDROED.
Unknown
Issued 6 August 1997
Resolved
PROVIDE GUAGING REPORT AND SCANTLINGS FOR #3 PORT/STARBOARD SW BALLAST TANKS, #2 PORT SW BALLAST TANK, AND FORE PEAK TANK AS INDICATED BY USCG MARINE INSPECTOR. INFORMATION MUST BE PROVIDED TO CREDIT DDX EXAM.
Construction/Loadline
Issued 28 September 1995
Resolved
ADJUST OR REPAIR TYPE I WATER TIGHT DOOR AT FORWARD END OF ENGINE ROOM TO ENSURE WATER TIGHT INTEGRITY.
Engineering
Issued 28 September 1995
Resolved
PROVIDE MACHINERY GUARD FOR THE LUBE OIL TRANSFER PUMP._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 28 September 1995
Resolved
PROVIDE ELECTRICAL MATTING AROUND MAIN SWITCHBOARD IN ENGINE ROOM._x001C_
Fire Fighting
Issued 9 November 1994
Resolved
PROVIDE ONE EACH ADDITIONAL CHARGE FOR FIRE FIGHTING OUTFIT TO COMPLY WITH SOLAS REQUIREMENTS.
Accommodation/Occupational Safety
Issued 1 October 1992
Resolved
PROVIDE PROPER RELIEF VALVE FOR PVHO PRIOR TO USE.
Electrical
Issued 1 October 1992
Resolved
PROVIDE PLANS FOR APPROVAL FOR THE INSTALLATION OF THE ROFLAN TYPE 1543 EMERGENCY LIGHTS THAT HAVE BEEN INSTALLED THROUGHOUT THE VESSEL. THIS MODIFICATION APPEARS TO HAVE BEEN DONE AROUND MARCH 1991.
Engineering
Issued 20 February 1991
Resolved
PROVIDE PROPER GAUGE ON DIESEL FUEL DAY TANK PER 46CFR58.50-10._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 20 February 1991
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR AND MONITOR._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 20 February 1991
Resolved
PROVE PROPER OPERATION OF ALL ALARMS/SHUTDOWNS ON AUXILLARY GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 20 February 1991
Resolved
PROVIDE ADEQUATE EMERGENCY LIGHTING TO ALL LIFERAFT EMBARKATION STATIONS PER 46CFR112,15-1 OF 1 JULY 1977 REGULATIONS._x001C_ _x001C_ _x001C_
Lifesaving
Issued 20 February 1991
Resolved
PROVIDE PROPER DAYLIGHT SIGNALLING LAMP PER 46CFR111.75-15(B)(2) OF 1 JULY 1977 REGULATIONS._x001C_ _x001C_ _x001C_
Engineering
Issued 20 February 1991
Resolved
PROVE PROPER OPERATION OF FUEL OIL TRANSFER PUMPS SHUTDOWNS FROM ALL LOCATIONS._x001C_ _x001C_ _x001C_
Engineering
Issued 20 February 1991
Resolved
PROVE PROPER OPERATION OF TACHOMETER FOR PORT MAIN DIESEL ENGINE AT ENGINE ROOM CONTROL CONSOLE._x001C_ _x001C_ _x001C_
Unknown
Issued 20 February 1991
Resolved
CONDUCT 1-1/2 X HYDROTEST ON PRESSURE VESSEL FOR HUMAN OCCUPANCY._x001C_ _x001C_ _x001C_ _x001C_
Unknown
Issued 20 February 1991
Resolved
INSTALL PROPER RELIEF VALVE ON PVHO OUTER CHAMBER.
Unknown
Issued 20 February 1991
Resolved
PROVIDE MEANS OF OPERATING LOCKING DEVICES FROM THE INTERIOR SIDE ON BOTH HATCHES OF PVHO.
Fire Fighting
Issued 23 September 1989
Resolved
HAVE FIXED CO-2 SYSTEM FOR THE ENGINE SPACE SERVICED BY A COMPETANT SERVICEFACILITY. SERVICING SHALL BE WITNESSED BY A COAST GUARD MARINE INSPECTOR- OR- PROVIDE AN AFFIDAVID OF SERVICE WHICH IS SIGNED AND NOTORIZED TO [name withheld], AK.
Accommodation/Occupational Safety
Issued 23 September 1989
Resolved
MAKE PERMANENT REPAIRS TO THE SEWAGE RETENTION/TREATMANT TANK. PROVIDE A LETTER, DETAILING REPAIRS, TO [name withheld], AK.
Fire Fighting
Issued 1 May 1986
Resolved
PRIOR TO DEPARTING THE PORT OF SEATTLE CONDUCT A FIRE DRILL WITH AN ASSIGNED CREW (OFFICERS AND CREW) AND IN NO CASE LATER THAN 30 JULY 86.
Casualty record · 3
1 December 2005Routine · role: Involved in a Marine Casualty · activity 2544765
2 March 2011Routine · role: Acknowledged Pollution Source · activity 4014898
18 March 2011Routine · role: Involved in a Marine Casualty · activity 3995922
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 2
AMERICAN SALVOR (2005), PREMIER EXPLORER (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.