MAURY USCG vessel records Sign in
← All vessels

MISS DORIS

MISS DORIS is a 1982 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1985, most recently in January 2010, along with 11 deficiencies and 1 casualty investigation in 2010.

Records from 1985 to 2010. Most recent: inspection, 19 January 2010.

Built
1982
Last inspected
19 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUW9905
Flag
UNITED STATES
367351790 (licence lapsed)
Maury page id
psix-54529

Inspections, by type

…with no type recorded3
Years with a record 14 calendar years (1985–2010)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WUW9905MMSI 367351790 · expired · voluntarily equipped · granted 25 April 2008, cancelled 1 September 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 21

19 January 2010 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3665870
8 June 2005 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2383484
23 March 2004 Deficiency Check · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2029483
25 February 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1749439
10 February 2003 Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1742207
3 December 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370442
4 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 665603
11 April 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 817032
4 February 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388998
17 November 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 787096
10 November 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1402541
6 October 1997 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419822
14 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1078000
27 January 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455030
9 November 1992 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267564
7 March 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217336
27 April 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 919269
22 January 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215320
12 January 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915509
12 December 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038026
23 August 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992879

Deficiency record · 11

Fire Fighting › Fire Pumps
Issued 23 March 2004 Resolved
Prove proper operation of installed firepump. LEGACY COMPONENT DESC: Inoperable
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Firepump provided adequate stream.
Construction/Loadline › Penetrations
Issued 23 March 2004 Resolved
Repair holes in passenger deck area by ladder and on portside. LEGACY COMPONENT DESC: Deck area
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: All holes clad welded.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 March 2004 Resolved
Repair stbd MDE raw water exhaust cooling pump impeller and correct alarm. LEGACY COMPONENT DESC: Exhaust Cooling
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 24 March 2004
Resolution: Impeller replaced and raw water exhaust alarm corrected
Documentation
Issued 11 April 2000 Resolved
OPERATION OF SMALL PASSEGER VESSEL UNDER 100 GT WITHOUT A VALID U.S. COAST GUARD CERTIFICATE OF INSPECTION ON BOARD.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Construction/Loadline
Issued 10 November 1997 Resolved
RENEW MARKINGS FOR FUEL OIL EMERGENCY SHUT OFF.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Construction/Loadline
Issued 10 November 1997 Resolved
RENEW HULL MARKINGS ON STERN
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Documentation
Issued 27 January 1993 Resolved
PROVIDE PROOF THAT A STABILITY TEST HAS BEEN CONDUCTED TO THE SATISFACTION OF THE COGNIZANT OCMI OR; CONDUCT A SATISFACTORY SIMPLIFIED STABILITY TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR IN ACCORDANCE WITH 46 CFRSUBCHAPTER "S".
Condition: Unknown
Due 27 January 1993
Resolved 27 January 1993
Engineering
Issued 12 January 1990 Resolved
MAKE REPAIRS TO 1/4" HOLE IN EXHAUST PIPING ON STBD ENGINE IN MACHINERY SPACE. IAW 46 CFR 176.25-10
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Construction/Loadline
Issued 12 January 1990 Resolved
REALIGN BOTH WATERTIGHT DOORS INTO PILOTHOUSE, BOTH DO NOT CLOSE AND SEAL. IAW 46 CFR 176.25-5
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Construction/Loadline
Issued 12 January 1990 Resolved
MAKE REPAIRS TO SMALL HOLE (1/2") IN STBD STERN CORNER AT DECK. IAW 46 CFR 176.25-5
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990
Documentation
Issued 12 January 1990 Resolved
PROVIDE FCC RADIO STATION LICENSE ON BOARD. IAW 46 CFR 184.25
Condition: Unknown
Due 12 January 1990
Resolved 12 January 1990

Casualty record · 1

19 January 2010Routine · role: Involved in a Marine Casualty · activity 3665870
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.