← All vessels
NEW CALIFORNIA DAWN
NEW CALIFORNIA DAWN is a 1976 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in December 2024, along with 30 deficiencies and 1 casualty investigation in 2015.
Records from 2015 to 2024. Most recent: inspection, 3 December 2024.
- Built
- 1976
- Last inspected
- 3 December 2024
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2015
Identity
570855
WDI5979
54539
Flag
UNITED STATES
Maury page id
psix-54539
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)52.2 ft × 15.8 ft × 6.1 ft
Registered tonnagegross 44 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARDS INC · WESTPORT, WA, UNITED STATES · built 1976
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 20 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Regulatory (Subpart C or D), Net Ton
44 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 18
3 December 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8040839
29 October 2024
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8026103
13 November 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7822623
15 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7609755
28 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7598567
26 October 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7583721
28 April 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7439914
8 December 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7364009
3 August 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7277353
5 November 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7090638
17 September 2020
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7060297
28 August 2020
COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044841
28 August 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6797722
13 November 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6577574
3 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6414007
17 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6126445
24 October 2016
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6028931
2 May 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5867501
Deficiency record · 30
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. Electrical panel in forward compartment not labeled/did not have breaker directory.
46 CFR 183.220 (d)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 December 2024
Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to - training in the use and location of firefighting equipment and general firefighting knowledge, including: Location of firefighting appliances and emergency escape routes; Types and sources of ignition; Flammable materials, fire hazards and spread of fire; The need for constant vigilance; Actions to be taken on board; Fire and smoke detection and automatic systems on board; and Classification of fire and applicable extinguishing agents, The drills required by § 185.524, including fire location and fire type; and Emergency egress training for each member of the crew, to occur for all members of the crew— at least monthly and each time a crew member joins the crew. Previously logged crew training did not include additional requirements for vessels on oceans routes.
46 CFR 185.420 (b)(1)
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 3 December 2024
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Flame screen on port fuel vent torn/damaged.
46 CFR 182.450 (e)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 December 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Lanyard connecting floating waterlight to ring life buoy not attached around the body of the ring.
46 CFR 180.70 (d)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.112. Each life jacket light must be securely attached to the front shoulder area of the life jacket. Light on 1 child life jacket inoperable.
46 CFR 180.74 (a)
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 29 October 2024
Resolved
Electrical equipment used in the following locations must be drip proof:(1) A machinery space. MI observed wire terminal near starting battery in engine room without drip proof cover. 46 CFR 183.210(a)(1)
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 November 2023
Resolved
Vessels operated beyond the 20 nautical mile limitation of this section, but not more than 100 nautical miles from the nearest land must be equipped with VHF-DSC. Vessels VHF equipment does not have GPS loaded for DSC. Vessel to install GPS to their VHF system for DSC to the satisfaction of the marine inspector.
46 CFR 80.905(a)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2023
Resolved
The ring life buoy grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Vessels ring life buoy grab line has sun damage and has started to deteriorate. Vessel to replace grab line to the satisfaction of the marine inspector.
46 CFR 160.050-3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 November 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessels main service generator has two sets of dead end wires. Vessel to cap off dead end wires to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2023
Resolved
Batteries chargers must have an ammeter connected in the charging circuit. Vessel does not have an ammeter in their charging circuits. Vessel to install ammeters to their charging circuits to the satisfaction of the marine inspector.
46 CFR 183.350(f)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2023
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space, and no more than 5 gallons of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of one gallon or less. Vessel has over 20 gallons of combustible liquids stored in the forward accommodation space and in the engine room. Vessel to remove combustible liquids from accommodation space and limit liquids to 5 gallons in the engine room to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2023
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 12 inches into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of , or some noncombustible material. Vessels stbd side flame bowl has substantial corrosion rendering it useless. Vessel to replace flame bowl to the satisfaction of the marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 November 2023
Resolved
Flammable items not otherwise covered by the regulation of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposed, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel does not have a lithium battery charging plan. Vessel to post lithium ion charging plan signage in accommodation space where passengers will be able to access it to the satisfaction of the marine inspector.
46 CFR 185.364
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 November 2022
Resolved
A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less than 25 millimeters (1 inch) nominal pipe size. A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Observed broken strainer for bilge pump in forward compartment. Vessel to replace strainer to the satisfaction of the Marine Inspector.
46 CFR 182.510(b)
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 November 2022
Resolved
Each PFD must have at least 200 sq. cm. (31 sq. in.) of retroreflective material on its front side, at least 200 sq. cm. on its back side and at least 200 sq. cm. of material on each reversible side, if any. The material must be Type I material that is approved under Subpart 164.018 of this chapter. The material attached on each side must be divided equally between the upper quadrants of the side. Vessel to replace missing retro-reflective material on life ring to the satisfaction of the Marine Inspector.
46 CFR 160.077-13
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 August 2020
Resolved
46 CFR 177.15(a) Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the may be quartered or normally employed so located that if one is not available the other may be. Vessel's forward escape hatch is difficult to access and requires additional handholds, steps, and/or grab bars to be installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 August 2020
Resolved
Penetrations and openings in watertight bulkheads must be kepts as high and as far inboard as practicable and have means to make them watertight. The vessel's collision bulkhead has two open penetrations approximately the size of a screw. These penterations need to be made watertight.
Engineering › Fuel Oil Service System › Valve
Issued 3 May 2018
Resolved
Port side fuel shut off valve handle located in the space is not shielded from flames. 46 CFR 182.455(b)(4).
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2018
Resolved
Radiotelephony certificate is expired. 47 CFR 80.903
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2018
Resolved
Vessel has expired medicine on board. 46 CFR 184.710
Fire Fighting › Fire Bucket › Lanyard
Issued 3 May 2018
Resolved
Fire buckets do not have attached lanyards. 46 CFR 181.610
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 May 2018
Resolved
Vessel does not have an up to date Coast Pilot on board. 46 CFR 184.420
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 May 2018
Resolved
Vessel does not have an up to date Light List. 46 CFR 184.420
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2018
Resolved
Vessel has out of date charts on board. 46 CFR 184.420
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2017
Resolved
First Aid Kit contained expired medications and was not stored IAW with 46 CFR 184.710.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 April 2017
Resolved
Children Life jackets were not stowed seperately from adult life jackets IAW 46 CFR 180.25-10 in old T regulations.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 April 2017
Resolved
60 ft Lifeline was not attached life ring IAW with Old T 46 CFR 180.30-10 (a).
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 April 2017
Resolved
Battery Charger Wires are not suitable for Marine Service IAW Old T 46 CFR 183.10.20.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 April 2017
Resolved
Vessel had plastic combustible waste receptacles. Need Receptacles that meet 46 CFR 177.405 requirements.
Construction/Loadline › Structures › Machinery Space Opening
Issued 17 April 2017
Resolved
Forward and Aft Engineroom Bulkheads contained 3/4" holes preventing them from being vapor tight as required in 46 CFR 182.35-1.
Casualty record · 1
24 September 2015Routine · role: Involved in a Marine Casualty · activity 5778352
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SUPERFISH (2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.