Records from 2016 to 2018. Most recent: inspection, 19 September 2018.
Documentation record
Registered dimensions (L × B × D)32.0 ft × 11.0 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINLAND SEAS BOAT CORP. · SANDUSKY, OH, UNITED STATES · built 1965
Hull materialSteel
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portHAMMOND, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Net Ton
14 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 July 2017
Resolved
Vessels name was unreadable, stencil lifebuoy with vessels name.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Lifebuoy has been re-stenciled.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2017
Resolved
Water light was not attached to the lifebuoy via lanyard. Attach water light to lifebuoy with lanyard with corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: New lanyard with corrosion resistant clip has been installed.
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2017
Resolved
Found navigation lights and VHF radio were operating intermittently. Traced problem to a knife switch under the control station. Loose connections going to and from switch. Tighten 12volt wire connections.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Master tightened loose connections and found problem still existed. Traced problem back to the Ammeter mount on the dash, tightened loose connections there, problem corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2017
Resolved
Lifebuoy water light battery has not been replaced annually. Replace battery and mark with date.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Water light battery has been replaced with new battery.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 July 2017
Resolved
Anchor light not operating. Repair or replace anchor light.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Anchor light is now working, problem traced back to a loose wire on the dash mounted Ammeter.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 July 2017
Resolved
Vessel had not completed annual fire extinguisher inspection. Vsl rep called and made an appointment with local fire extinguisher company for inspection for the next day.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 26 July 2017
Resolution: Annual inspection has been completed by 3rd party.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 July 2017
Resolved
Annual inspection has not been completed on installed fire extinguishing system. Vsl rep called and made an appointment with local fire extinguisher company for inspection for the next day.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 26 July 2017
Resolution: Annual inspection has been completed by 3rd party.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 July 2017
Resolved
Remote f/o shut-off valves not properly marked.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Emergency f/o shutoff valves have been marked.
Documentation › Certificates/Documents › FCC SSL
Issued 24 July 2017
Resolved
Vessel did not have a FCC Station License. Vsl rep called FCC and is in the process of obtaining a Station License. GL radio inspection had not been completed as well. Vsl rep calling local 3rd party to have GL radio inspection complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2017
Resolved 4 August 2017
Resolution: Vessel received FCC station license and completed a GL radio inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 June 2016
Resolved
COD not displayed - display COD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Current COD placed on vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 June 2016
Resolved
COI not displayed - display COI
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Current COI intalled on vessel, visible to passengers.
Engineering › Fuel Oil Service System › Valve
Issued 8 June 2016
Resolved
Starboard emergency F/O shutoff valve not operational - ensure proper operation of valve.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Starboard Fuel Valve raised and accessable through new deck. Operation satisfactory.
Stability › Unintentional Flooding › General
Issued 8 June 2016
Resolved
Aft Overboard drain lines not connected - connect drain lines in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Aft Deck Drain hoses reconnected to satisfaction of Marine Inspector.