MAURY USCG vessel records Sign in
← All vessels

CEDAR GROVE

CEDAR GROVE is a 1965 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 1985, most recently in September 2018, along with 44 deficiencies.

Records from 1985 to 2018. Most recent: inspection, 19 September 2018.

Built
1965
Last inspected
19 September 2018
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ6808
Flag
UNITED STATES
368000420
Maury page id
psix-54540

Inspections, by type

…with no type recorded1
Years with a record 19 calendar years (1985–2018)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.0 ft × 11.0 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINLAND SEAS BOAT CORP. · SANDUSKY, OH, UNITED STATES · built 1965
Hull materialSteel
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portHAMMOND, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Net Ton
14 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ6808MMSI 368000420 · active · compulsorily equipped · granted 25 July 2017, expires 25 July 2027
WDD9382MMSI 367310550 · expired · compulsorily equipped · granted 29 August 2007, cancelled 4 November 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

19 September 2018 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6543807
24 July 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6218863
8 June 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5909481
4 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5869137
9 October 2015 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5739226
13 June 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4887872
23 May 2012 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4320857
19 October 2010 Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3873510
4 May 2009 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3467187
25 March 2009 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3439747
24 October 2008 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3354562
7 August 2008 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3320391
22 May 2008 Simplified Stability Test
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3249660
18 September 2007 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3083049
10 October 2006 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2798518
26 July 2005 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2433578
23 July 2004 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2143313
27 May 2004 Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2080038
30 October 2003 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1943651
3 October 2002 Annual Inspection
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1702707
25 September 2001 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1075268
19 September 2001 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1395809
5 July 2001 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1067173
13 July 2000 Hull Examination · COI Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1436445
12 December 1989 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1303385
17 November 1989 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1215056
8 October 1985 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1293891
16 May 1985 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1292030

Deficiency record · 44

Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 July 2017 Resolved
Vessels name was unreadable, stencil lifebuoy with vessels name.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Lifebuoy has been re-stenciled.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2017 Resolved
Water light was not attached to the lifebuoy via lanyard. Attach water light to lifebuoy with lanyard with corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: New lanyard with corrosion resistant clip has been installed.
Electrical › Electric Supply System (service) › Cable
Issued 24 July 2017 Resolved
Found navigation lights and VHF radio were operating intermittently. Traced problem to a knife switch under the control station. Loose connections going to and from switch. Tighten 12volt wire connections.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Master tightened loose connections and found problem still existed. Traced problem back to the Ammeter mount on the dash, tightened loose connections there, problem corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2017 Resolved
Lifebuoy water light battery has not been replaced annually. Replace battery and mark with date.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Water light battery has been replaced with new battery.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 July 2017 Resolved
Anchor light not operating. Repair or replace anchor light.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Anchor light is now working, problem traced back to a loose wire on the dash mounted Ammeter.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 July 2017 Resolved
Vessel had not completed annual fire extinguisher inspection. Vsl rep called and made an appointment with local fire extinguisher company for inspection for the next day.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 26 July 2017
Resolution: Annual inspection has been completed by 3rd party.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 July 2017 Resolved
Annual inspection has not been completed on installed fire extinguishing system. Vsl rep called and made an appointment with local fire extinguisher company for inspection for the next day.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 26 July 2017
Resolution: Annual inspection has been completed by 3rd party.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 July 2017 Resolved
Remote f/o shut-off valves not properly marked.
Condition: Improper/Lack of Maintenance
Due 25 July 2017
Resolved 4 August 2017
Resolution: Emergency f/o shutoff valves have been marked.
Documentation › Certificates/Documents › FCC SSL
Issued 24 July 2017 Resolved
Vessel did not have a FCC Station License. Vsl rep called FCC and is in the process of obtaining a Station License. GL radio inspection had not been completed as well. Vsl rep calling local 3rd party to have GL radio inspection complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2017
Resolved 4 August 2017
Resolution: Vessel received FCC station license and completed a GL radio inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 June 2016 Resolved
COD not displayed - display COD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Current COD placed on vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 June 2016 Resolved
COI not displayed - display COI
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Current COI intalled on vessel, visible to passengers.
Engineering › Fuel Oil Service System › Valve
Issued 8 June 2016 Resolved
Starboard emergency F/O shutoff valve not operational - ensure proper operation of valve.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Starboard Fuel Valve raised and accessable through new deck. Operation satisfactory.
Stability › Unintentional Flooding › General
Issued 8 June 2016 Resolved
Aft Overboard drain lines not connected - connect drain lines in engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2016
Resolved 9 June 2016
Resolution: Aft Deck Drain hoses reconnected to satisfaction of Marine Inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 October 2010 Resolved
Provide batteries within appropriate enclosure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2011
Resolved 17 May 2011
Resolution: Enclosures installed prior to departure.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 May 2009 Resolved
Service engine room fire suppresion system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2009
Resolved 21 June 2010
Resolution: Sevice report provided for 2010 inspection no records available for 2009.
Engineering › Bilge Water Management System › Pump
Issued 4 May 2009 Resolved
Mount bilge pump in engine room. Currently bilge pump is installed but not mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2009
Resolved 21 June 2010
Resolution: Bilge pump secured with appropriate bracket.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 May 2009 Resolved
Provide proof of DAPI enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2009
Resolved 15 July 2010
Resolution: Received documentation from o/o of enrollment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 May 2009 Resolved
Renew damaged wire at forward bulkhead of enginroom.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 15 July 2010
Resolution: Received notification from o/o that item had been corrected.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 4 May 2009 Resolved
Mount wire in engine room with metallic hangers. Remove all plastic wire hangers.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 15 July 2010
Resolution: Received notification from o/o that item had been corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 May 2009 Resolved
Renew compression fittings (splice) under W/H console. There is evidence of overheating.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 15 July 2010
Resolution: Received notification from o/o that item had been corrected.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 4 May 2009 Resolved
Provide means to prevent chaffing of stbd E/R ventilation exhaust pipe by steering gear.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 15 July 2010
Resolution: Received notification from o/o that item had been corrected.
Engineering › Bilge Water Management System › Not Installed
Issued 4 May 2009 Resolved
Provide independent visual indicators for both high water alarms. Currently both bilge alarms use the same indicator light.
Action required: 705 - Other - as specified
Due 4 June 2009
Resolved 21 June 2010
Resolution: Two lights with alarm provided with demonstration during exam.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 August 2008 Resolved
All portable extinguishers had expired service tags.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2008
Resolved 8 August 2008
Engineering › Bilge Water Management System › Pump
Issued 7 August 2008 Resolved
E/R bilge pump was not mounted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2008
Resolved 7 August 2008
Resolution: Mounted bilge pump.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 August 2008 Resolved
Missing Coast pilot
Due 14 August 2008
Resolved 8 August 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 August 2008 Resolved
Missing light list
Due 14 August 2008
Resolved 8 August 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 September 2007 Resolved
Replace expired items in first aid kit
Due 2 October 2007
Resolved 1 October 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 September 2007 Resolved
Provide annual service on fixed system and portable fire extinguishers
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2007
Resolved 4 October 2007
Resolution: Had system and extinguisher serviced.
Fire Fighting › Fixed Fire Detection System
Issued 3 October 2002 Resolved
When bottle was being removed for annual servicing, accidental discharge occured. Manufacture notified and provided new bottle. Issued requirement for vessel NOT to carry passengers for hire until a bottle was installed and the system was inspected by an attending marine inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2002
Resolution: Bottle was reinstalled and inspected.
Accommodation/Occupational Safety › Medical/First Aid
Issued 3 October 2002 Resolved
Required first aid kit was not available for inspection.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2002
Engineering
Issued 19 September 2001 Resolved
RENEW FUEL TANK FLAME SCREENS WITH 30X30 MEST NO LATER THATN 19OCT01 AND PROVIDE STATEMENT TO MSD MASSENA WHEN DISCREPANCY IS COPLETED.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Electrical
Issued 13 July 2000 Resolved
Install metal electrical wire hangers in E/R every two feet.
Condition: Unknown
Due 28 July 2000
Resolved 24 October 2000
Unknown
Issued 13 July 2000 Resolved
Pay vessel user fee within 30 days.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Construction/Loadline
Issued 13 July 2000 Resolved
Make main weather deck of cockpit vessel watertight iaw 46 CFR 171.145(a) by 01MAY01 (prior to operating in 2001)
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Engineering
Issued 13 July 2000 Resolved
Replace emergency fuel shutoff valve handle, port side.
Condition: Unknown
Due 28 July 2000
Resolved 24 October 2000
Lifesaving
Issued 13 July 2000 Resolved
Replace cabin overhead (headliner) to cover exposed screws.
Condition: Unknown
Due 28 July 2000
Resolved 24 October 2000
Documentation
Issued 13 July 2000 Resolved
Provide proof of FCC SSL application.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Construction/Loadline
Issued 13 July 2000 Resolved
Install hatch closure to open forward hatch from both sides.
Condition: Unknown
Due 14 August 2000
Resolved 24 October 2000
Documentation
Issued 13 July 2000 Resolved
Establish vessel logs.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000
Accommodation/Occupational Safety
Issued 13 July 2000 Resolved
Strengthen deck railings.
Condition: Unknown
Due 28 July 2000
Resolved 24 October 2000
Lifesaving
Issued 13 July 2000 Resolved
Provide retroreflective material for ring buoy.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Fire Fighting
Issued 13 July 2000 Resolved
Provide one A-II fire extinguisher.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Lifesaving
Issued 13 July 2000 Resolved
Stencil adult PFD locations.
Condition: Unknown
Due 14 July 2000
Resolved 14 July 2000
Engineering
Issued 13 July 2000 Resolved
Post prominent ignition warning sign.
Condition: Unknown
Due 13 July 2000
Resolved 13 July 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.