Records from 2016 to 2023. Most recent: inspection, 21 September 2023.
Inspection history · 12
21 September 2023
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7795852
8 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7518542
1 June 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7193707
11 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7132268
3 February 2021
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7135081
6 November 2020
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7090890
19 July 2019
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6745700
25 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6625150
4 June 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6430008
18 July 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6197919
7 March 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6090260
15 July 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5933941
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2022
Resolved
Provision shall be made by means of plugs, covers, etc to prevent the admission of air into the space protected by a fire extinguishing system. Ventilation plugs do not fit together to close.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 12 August 2022
Resolution: Ventilation plugs have been fixed to fit properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2022
Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operation. Floating waterlight is cracked.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 12 August 2022
Resolution: Floating water light has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name on ring life buoy is faded and difficult to read.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 12 August 2022
Resolution: Ring life buoy has been remarked with vessel name.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 August 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of International and Inland Navigation Rules. Forward light does not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 12 August 2022
Resolution: Navigation light has been fixed and is working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2019
Resolved
Relabel remote F/O shutoff station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 30 July 2019
Resolution: New label installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 June 2018
Resolved
Prove proper operation of fixed fire system override.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2018
Resolved 19 June 2018
Resolution: Proved proper operation of fixed fire system override.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2018
Resolved
Staart bsttery bad, replace with new.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 June 2018
Resolved 5 June 2018
Resolution: New battery installed, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 June 2018
Resolved
Starter bad, r/r starter, prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 June 2018
Resolved 14 June 2018
Resolution: New starter installed, test sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 July 2017
Resolved
Provide proper operation of fire boy shut down.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2017
Resolved 20 July 2017
Resolution: Witnessed proper operation of fireboy.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 18 July 2017
Resolved
Provide current flares.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 July 2017
Resolution: Provided current flares.