Records from 1984 to 2006. Most recent: inspection, 26 July 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 73
26 July 2006
Type not recorded
No type recorded · Activities Europe · Activity 2725294
26 November 2002
Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1482297
11 February 2002
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1485402
9 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076815
17 October 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 61884
26 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 145633
7 September 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 60369
29 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1071753
19 August 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 28284
6 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1067836
31 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066389
14 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061601
4 April 2001
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061326
15 March 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1060127
9 March 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452772
1 February 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403292
8 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820148
12 January 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1381779
5 July 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 142319
9 June 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808146
10 May 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1129490
25 February 1999
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421610
19 January 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 797022
17 December 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 807792
21 May 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1399004
9 January 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436028
16 December 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1115347
31 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099653
11 March 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451152
20 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093622
16 July 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396547
16 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764741
4 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193840
27 March 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404120
5 January 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355614
9 January 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420941
2 November 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 131194
24 October 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1175593
25 August 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172205
16 August 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1178606
8 July 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461588
6 January 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 852210
25 February 1993
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 837948
25 February 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1148539
25 January 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1422203
7 January 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955135
3 April 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251419
26 February 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 922696
5 February 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251531
3 July 1990
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1218511
21 June 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 912693
10 May 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906263
10 May 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1251157
26 January 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226009
12 January 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1201662
3 November 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1201312
18 May 1988
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1194834
18 January 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1013996
14 January 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1318954
25 November 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028605
6 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014366
7 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325485
11 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014985
24 January 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018490
10 December 1986
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1331285
30 July 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1293042
16 February 1986
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1300563
2 January 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 988684
25 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287609
15 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977803
17 January 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1290176
8 June 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973337
6 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285000
Construction/Loadline
Issued 4 April 2001
Resolved
Submit repair proposal to cognizant OCMI in relation to those identified areas in gauging rpt dtd 10Nov00, having a depletion value greater than 15%for maindeck/bottom shell; 20% for sideshell; and 25% for internal members.Repairs shall be made to the satisfaction of an attending Marine Inspector.
Condition: Unknown
Due 4 April 2001
Resolved 4 April 2001
Unknown
Issued 9 March 2001
Resolved
Make all interior fire doors self-closing and latching. Remove all hold back devices, as previously outlined in deficiency list written at RIN by [name withheld].
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Unknown
Issued 9 March 2001
Resolved
Provide a copy of ABS' guaging report to [name withheld].
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew stiffeners and associated frames (where wasted) on forward bulkhead, inboard corner to no.6 starboard preload tank. Renew guides to dump valve body.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew all corner brackets and side stiffeners (where wasted) on _x001C_ aft bulkhead, inboard bay in no.2 preload tank starboard.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew aft bulkhead and aft transverse deep web frame where buckledand racked in starboard no. 3 preload tank. Submit repair proposal to [name withheld].
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Unknown
Issued 9 March 2001
Resolved
Re-work dump valve body valve guides in pre-load tanks 7P, 5P, 2P and 7S. Renew electrical stuffing tubes on port and aft side of house on main deck (as marked).
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Unknown
Issued 9 March 2001
Resolved
Crop and renew wasted sounding tube pre-load tank no.2 port.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew side shell girder (vertical) near aft ladder pre-load tank no.3 port.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew wasted side shell near aft ladder no.3 port pre-load.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Unknown
Issued 9 March 2001
Resolved
Clean and lubricate all pre-load tank dump check valves.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew tripped bottom shell girder and bottom shell stiffeners in preload tank no.6 port at spud can recess.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew wasted watertight bulkhead between pre-load tanks no.4 port and 5 port.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew wasted side shell in pre-load tank no.5 port at forward ladder.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Crop and renew aft ladder in pre-load tank no.3 port. Crop and renew port ladder in pre-load tank no.8.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Deck/Cargo
Issued 9 March 2001
Resolved
Descale and renew gasket at flange to overhead raw water line in mud pump room, where leaking.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Address wasted interior bulkhead and stiffener in pre-load tank no.4 port.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Address wasted side shell, side shell stiffener and corner gussets in port two bays in pre-load tank no.8 centerline.
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Unknown
Issued 9 March 2001
Resolved
Complete underwater portion and NDE of critical connections. Submit copy_x001C_ of diver's report and guaging report to [name withheld].
Condition: Unknown
Due 9 March 2001
Resolved 9 March 2001
Accommodation/Occupational Safety
Issued 12 January 2000
Resolved
PROVIDE ON BOARD A NEW MARINE SANITATION DEVICE, CG. APPROVED._x001C_
Condition: Unknown
Due 10 February 2000
Resolved 10 February 2000
Fire Fighting
Issued 12 January 2000
Resolved
PROVIDE ON BOARD, AN APPROVED COPY OF THE FIRE AND SAFETY PLAN.
Condition: Unknown
Due 12 February 2000
Resolved 11 February 2000
Construction/Loadline
Issued 10 May 1999
Resolved
Complete permanent repairs to wasted sideshell and sideshell longitudinals in preload tank nos. 2P, 3P, 3S, 4P, 5P, 6P, 7S and 8C in accordance with the ABS Repair Survey Report (ABSID 8126246, report no. MC10139, dtd 18MAR99) items 6A thru 6H.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 25 February 1999
Resolved
Conduct gaugings on side shell plating and associated longitudinals (longs)in port and stbd pre-load tanks in areas of heavy wastage (typically from bottom up to sixth from bottom long) where Eureka coating has failed due tocontinual exposure to flare boom heat.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Accommodation/Occupational Safety
Issued 25 February 1999
Resolved
Crop and renew wasted mud pit room supply fan ducting (cowling) where it passes through port sack storage room.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Construction/Loadline
Issued 19 January 1999
Resolved
Make available for inspection upper hull prior to next rig move or notify this office if rig will move out of MSO Mobile zone prior to completing this requirement. This requirement must be completed in order to receive SEILOD credit.
Condition: Unknown
Due 25 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 19 January 1999
Resolved
Crop & renew all deteriorated underdeck framing located in mud pit room.
Condition: Unknown
Due 19 January 1999
Resolved 26 February 1999
Construction/Loadline
Issued 19 January 1999
Resolved
Crop & renew all deteriorated steel located on fwd bulkhead of mud pit room.
Condition: Unknown
Due 19 January 1999
Resolved 26 February 1999
Lifesaving
Issued 9 January 1998
Resolved
CONTACT USCG MSO MOBILE WHEN LIFEBOAT #2 REPLACEMENT IS TO BE INSTALLED ON BOARD.
Condition: Unknown
Due 9 January 1998
Resolved 15 January 1998
Electrical
Issued 9 January 1998
Resolved
PROVE PROPER OPERATION OF GENERATOR SET #3 SAFETY ALARMS.
Condition: Unknown
Due 9 February 1998
Resolved 27 January 1998
Electrical
Issued 9 January 1998
Resolved
CONDUCT REPAIRS/MAINTENANCE IN CLASSIFIED HAZARDOUS LOCATIONS PER 14 ITEM WORKLIST.
Condition: Unknown
Due 9 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 9 January 1998
Resolved
CONDUCT FIRE/ABANDON RIG DRILLS.
Condition: Unknown
Due 9 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 9 January 1998
Resolved
INSTALL LIGHT FOR GENERAL ALARM IN MUD PIT ROOM._x001C_
Condition: Unknown
Due 9 February 1998
Resolved 20 February 1998
Documentation
Issued 9 January 1998
Resolved
MAXIMUM NUMBER OF PEOPLE ON BOARD MODU RESTRICTED TO 58 DUE TO LIFEBOAT #2 NOT ON BOARD FOR SERVICING.
Condition: Unknown
Due 9 January 1998
Resolved 15 January 1998
Unknown
Issued 11 March 1997
Resolved
REPLACE 150 PSI RELIEF VALVE ON ONE HOT WATER HEATER WITH A 100 PSI VALVE.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Engineering
Issued 11 March 1997
Resolved
REPAIR COOLING HOSE LEAK ON EMERGENCY GENERATOR.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 11 March 1997
Resolved
RENEW STEERING CABLE ON #2 LIFEBOAT.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Fire Fighting
Issued 11 March 1997
Resolved
RENEW CO2 BOTTLE AT PAINT LOCKER.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 11 March 1997
Resolved
MAKE REPAIRS, ALTERATIONS AND CHANGES IN POLICY TO COMPLY WITH REVISIONS TO46 CFR 107-109. REFERENCE WORKLIST ISSUED TO OIM ON 11MAR97 AND FEDERAL REGISTER, VOLUME 61, NO. 98, DATED 20MAY96.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997
Resolved
REPAIR PURGE AIR FUNCTION ON GAS DETECTION BOX ON DRILL FLOOR.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 11 March 1997
Resolved
RENEW LIFE LINES ON BOTH LIFEBOATS.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 11 March 1997
Resolved
ENSURE BREATHING AIR BOTTLES IN BOTH LIFEBOATS ARE WITHIN HYDRO DATES AND PROPERLY FILLED.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Lifesaving
Issued 11 March 1997
Resolved
REPLACE TWO LIFERINGS.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997
Resolved
RENEW WASTED COOLING WATER PIPING ON AIR COMPRESSOR SYSTEM.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997
Resolved
REVERSE ROTATION OF ONE FAN IN PUMP ROOM TO OBTAIN ONE SUPPLY AND ONE EXHAUST.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Construction/Loadline
Issued 27 March 1996
Resolved
OPEN, MAKE SAFE FOR WORKERS AND PRESENT FOR INSPECTION PRELOAD TANK 4S, ANDTHE DUMP VALVE CONTAINED INSIDE.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Fire Fighting
Issued 27 March 1996
Resolved
PLUG HOLES IN OVERHEAD IN GALLEY.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Construction/Loadline
Issued 27 March 1996
Resolved
REPLACE STRAINER ON BILGE SUCTION.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Construction/Loadline
Issued 27 March 1996
Resolved
CONDUCT PHASE II SEILODD IN ACCORDANCE WITH USCG APPROVED PLAN DURING NEXT RIG MOVE.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Construction/Loadline
Issued 27 March 1996
Resolved
MAKE PERMANENT REPAIRS TO DOUBLER IN OVERHEAD OF VOID #2 UNDER THE DIRECTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Construction/Loadline
Issued 27 March 1996
Resolved
OPEN AND PRESENT FOR INSPECTION, THE MASTER MUD PIT DUMP VALVE.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Deck/Cargo
Issued 5 January 1996
Resolved
OPEN, GAS-FREE, AND MAKE ALL DRY BULK TANKS AVAILABLE FOR INTERNAL EXAMINATION BY COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Lifesaving
Issued 9 January 1995
Resolved
REPLACE 03 WASTED RING BOUYS ON MAIN DECK
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 9 January 1995
Resolved
REPAIR BULKHEAD PENETRATIONS IN PORT/STARBOARD MUD PUMPROOM
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Electrical
Issued 9 January 1995
Resolved
REPAIR/REPLACE PURGE ALARM ON DRILLERS CONSOLE
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 9 January 1995
Resolved
PROVIDE (2) PROPER 4KG RING BOUYS ON BRIDGE AREA.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 9 January 1995
Resolved
CLEAN/REPLACE COXSWAINS WINDOW ON #2 LIFEBOAT.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 9 January 1995
Resolved
REPLACE FLARES ON BRIDGE WIGH 12 HANDHELD PARACHUTE
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Unknown
Issued 9 January 1995
Resolved
INSTALL PROPER RELIEF VALVE (HANDLE) ON OUTBOARD AIR RECEIVER
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Deck/Cargo
Issued 6 January 1994
Resolved
REMOVE FROM VESSEL, THE DRILL FLOOR AIR RECIEVER DUE TO WASTAGE (HOLES IN SHELL AND CONNECTIONS). ADVISE LOCAL [name withheld]/WHEN A NEW RECIEVER IS INSTALLED PRIOR TO PLACING IT BACK IN SERVICE.
Condition: Unknown
Due 15 April 1994
Resolved 2 February 1994
Unknown
Issued 6 January 1994
Resolved
PROVIDE DOCUMENATION FOR THE VESSEL POWER INDUSTRIAL TRUCK, THAT IT MEETS THE REQUIRMENTS OF 46 CFR 109.509
Condition: Unknown
Due 6 January 1994
Resolved 6 January 1994
Lifesaving
Issued 25 January 1993
Resolved
PROVIDE ON BOARD PROPER LINE THROWING APPARATUS.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Electrical
Issued 25 January 1993
Resolved
PROVE PROPER OPERATION OF AUDIBLE ALARMS FOR ALL MAIN GENERATORS.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Lifesaving
Issued 25 January 1993
Resolved
RENEW GASKETS FOR DOORS IN PORT LIFEBOAT.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Fire Fighting
Issued 25 January 1993
Resolved
HYDROTEST BOTH SCBA BOTTLES FOR EMERGENCY FIREMAN'S SUITS.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Fire Fighting
Issued 25 January 1993
Resolved
PROVE PROPER OPERATION OF FIXED FIREFIGHTING SYSTEMS TIME DELAYS AND SHUTDOWNS.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Fire Fighting
Issued 7 January 1992
Resolved
PROVIDE COPY OF AFFF FOAM TEST REPORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Fire Fighting
Issued 7 January 1992
Resolved
HYDROSTATICALLY TEST HALON BOTTLE #11304 USED TO PROTECT ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Lifesaving
Issued 5 February 1991
Resolved
PROVIDE NEW BATTERY FOR EPIRB.
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Fire Fighting
Issued 5 February 1991
Resolved
PROVE OPERATION OF HALON SYSTEM IN SCR AND GENERATOR ROOM.
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Fire Fighting
Issued 5 February 1991
Resolved
INSTALL AN ADDITIONAL GENERAL ALARM LIGHT TO PORTSIDE MUD PUMP ROOM.
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Lifesaving
Issued 5 February 1991
Resolved
PROVIDE NEW RING BUOY ON STBD SIDE AT LIFEBOAT ONE STATION.
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Fire Fighting
Issued 5 February 1991
Resolved
INSTALL OR MOVE MANUAL PULLS OF CO2 SYSTEM ON THE GENERATOR TO THE SAME VICINITY AS THE HALON MANUAL PULL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Construction/Loadline
Issued 3 July 1990
Resolved
PROVIDE REPAIR PROCEDURES AND MAKE PERMANENT REPAIRS TO HOLE IN BOTTOM PLATING IN WAY OF SUCTION LINE IN #4 STARBOARD PRE-LOAD TANK
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Fire Fighting
Issued 14 January 1988
Resolved
REMOVE PAINT FROM PAINT LOCKER UNTIL FIXED FIREFIGHTING SYSTEM HAS BEEN SERVICED.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Deck/Cargo
Issued 14 January 1988
Resolved
COMPLETE AN ANNUAL EXAM ON THE CRANES AND SUBMIT A COPY OF THE EXAM TO MSO PORT ARTHUR, TEXAS.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Fire Fighting
Issued 14 January 1988
Resolved
SUBMIT AN UPDATED AND CORRECTED FIRE CONTROL PLAN TO MSO PORT ARTHUR, TEXASSHOWING THE CORRECT LOCATION AND AMOUNT OF LIFESAVING AND FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Lifesaving
Issued 14 January 1988
Resolved
REPLACE THE EXPENDED FLOATING SMOKE PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Construction/Loadline
Issued 14 January 1988
Resolved
CONDUCT TEST ON NUMBER 1 BILGE PUMP PRIOR TO LEAVING PORT.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Construction/Loadline
Issued 14 January 1988
Resolved
PAINT THE VESSEL'S NAME ON THE HELICOPTER PAD.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Lifesaving
Issued 14 January 1988
Resolved
ONCE THE FULL CREW IS ON BOARD AND PRIOR TO LEAVING PORT CONDUCT A FIRE ANDBOAT DRILL.
Condition: Unknown
Due 14 January 1988
Resolved 14 January 1988
Electrical
Issued 24 January 1987
Resolved
CLEAR BATTERY TERMINALS FOR EMERGENCY GENERATOR
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Deck/Cargo
Issued 24 January 1987
Resolved
ON FORKLIFT IN SACK ROOM, POST MAXIMUM LOAD CAPABILITY AND REPAIR REVERSE MOVEMENT ALARM
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
PROPERLY SET OVERSPEED SHUTDOWN ON EMERGENCY GENERATOR TO TRIP AT NOT OVER 115% OF MAX. RATED RPM OF ENGINE.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REBUILD COLLAPSED CABLE TRAYS IN MUD PITS.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
TOTAL PERSONS ALLOWED ABOARD RIG IS REDUCED TO NOT MORE THAN 69, UNTIL THE INFLATABLE DAVIT LAUNCH LIFE RAFTS ARE SERVICED.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
SUBMIT FIRE CONTROL AND LIFE SAVING PLAN TO REFLECT CHANGES MADE INMOTOR LIFE BOATS AND OTHER EQUIPMENT
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
PPROVIDE ONBOARD A STAMPED C.G. APPROVED HAZARDOUS LOCATION PLAN
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REMOVE DEAD-END ELECTRICAL CABLES ON TOP OF DRILLERS CANSOLE, DRILL FLOOR
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REMOVE DEAD-END ELECTRICLAL CABLES ON PIPE RACK, STBD SIDE, AFT, ON DECK AND PROPERLY SUPPORT ELECTRICAL CABLES IN SAME LOCATION UNDER DRILL FLOOR DECK.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REMOVE DEAD-END ELECTRICAL CABLES ABOVE SHAKENS AND PROPER SUPPORT OTHER CABLES IN OVERHEAD IN SAME AREA.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
INSTALL ELECTRICAL INSULLATION DECK MAT IN FRONT OF MUD PUMP ELECTRICAL SWITCHBOARD PANEL IN SCR ROOM.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAYS ON NO.2 AND 3 EMD
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Fire Fighting
Issued 24 January 1987
Resolved
PROVIDE SERVICABLE COMBINATION NOZZEL FOR FIRE STATION #15 AND #11
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
REPAIR LIMIT SWITCHES AND ASSOCIATED PLUNGES ON LIFEBOATS NO.1 & 2
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Navigation
Issued 24 January 1987
Resolved
PROVIDE WINDSOCK FOR HELICOPTER PAD
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Deck/Cargo
Issued 24 January 1987
Resolved
REMOVE UNUSED CABLE LOCATED IN VICINITY OF FIRE STATION #16
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REMOVE UNUSED CABLE LOCATED ADJACENT TO GEOLOGRAPH
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REMOVE UNUSED CABLE LOCATED IN VICINTY OF FIRE STATION #16
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
REPLACE MISSING EMERGENCY LIGHT IN VICINITY OF STB LIFERAFT STATION
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Lifesaving
Issued 24 January 1987
Resolved
PROVIDE REQUIRED ORANGE SMOKE SIGNALS FOR LIFEBOAT #3
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Fire Fighting
Issued 24 January 1987
Resolved
CONDUCT HYDROSTATIC SERVICING FOR PORTABLE FIRE EXTINGUISHER
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Deck/Cargo
Issued 24 January 1987
Resolved
REPLACE UNSERVICABLE DEAD MAN HELICOPTER FUEL FILL NOZZEL OR SECURE VAVLE WITH BLANK ONE.
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Navigation
Issued 24 January 1987
Resolved
MAKE ALL HELICOPTER DECK LANDING LIGHTS OPERABLE
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Electrical
Issued 24 January 1987
Resolved
MAKE ALL TERMINAL CONNECTIONS FOR EMERGENCY BATTERIES ARE CORROSION FREE
Condition: Unknown
Due 24 January 1987
Resolved 24 January 1987
Navigation
Issued 30 July 1986
Resolved
MAKE PERMANENT REPAIRS TO NAVIGATION LIGHT PANEL INDICATORS, IN CONTROL ROOM, FOR STBD AND STERN LIGHTS.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Navigation
Issued 2 January 1986
Resolved
MAKE PERMANENT REPAIRS TO NAV. LIGHT PANEL INDICATORS, IN CONTROL ROOM FOR STBD AND STERN LIGHTS.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Fire Fighting
Issued 2 January 1986
Resolved
MAKE PERMANENT REPAIRS TO SELF CLOSING DOORS ONE ON LEVEL B, THREE ON MAIN DECK.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Electrical
Issued 2 January 1986
Resolved
PROVIDE PROOF THAT THE FOLLOWING FIXTURES IN THE PUMP ROOM ARE EXPLOSION PROOF OR ENSURE THAT THE DOOR BETWEEN THIS ROOM AND THE MUD PIT ROOM MEETS THE REQUIRMENTS OF 46CFR 108,175 (C). ALL MUD PUMP STROKE CENTER LIMIT SWITCHES, AND MUD PUMP ROOM BLOWER FAN SWITCH.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Electrical
Issued 2 January 1986
Resolved
PROVIDE PROPER EYS FITTINGS FOR: FOUR LIGHTS UNDER RIG DRILL FLOOR ALSO PROVIDE PROOF THAT THESE ARE EXPLOSION PROOF.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Electrical
Issued 2 January 1986
Resolved
PROVIDE PROOF THAT THE TWO BRAKE COOLING WATER PUMP SWITCHES ARE EXPLOSION PROOF OR REPLACE THEM
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Electrical
Issued 2 January 1986
Resolved
REPAIR PURGE AIR SYSTEM FOR UNUSED GAS DETECTER IN DOG HOUSE OR REMOVE IT.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Fire Fighting
Issued 2 January 1986
Resolved
REPAIR SCR ROOM HALON SYSTEM VENTILATION AND ENGINE SHUT DOWN PRESSURE SWITCH AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Unknown
Issued 2 January 1986
Resolved
PROVIDE TWO ADDITIONAL LIFEBOATMEN FOR A TOTAL OF FOUR.
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Fire Fighting
Issued 2 January 1986
Resolved
PROVIDE COMPLETE FOAM ANALYSIS CERTIFICATE
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Construction/Loadline
Issued 2 January 1986
Resolved
CONDUCT QUADRIENNIEL PROOF LOAD TESTS & EXAMINATION FOR ECGB - LAST DUE 05AUG81
Condition: Unknown
Due 2 January 1986
Resolved 2 January 1986
Construction/Loadline
Issued 17 January 1985
Resolved
PROVIDE FOR THE HELIPORT A NON-SKID SURFACE AS REQUIRED BY 46 CFR 108.235 (D)(I).
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Documentation
Issued 17 January 1985
Resolved
UPDATE THE OIL TRANSFER PROCEDURES REQUIRED BY 46 CFR 109.583(C).
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Fire Fighting
Issued 17 January 1985
Resolved
MAKE REPAIRS OR RENEW THE NO.26 FIRE HOSE STATION HYDRANT VALVE.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985
Resolved
PROVIDE FOR THE MOVABLE BUG BLOWER MALE PLUG THE RECEPTICLE RETAINING SCREWCOLLAR.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985
Resolved
PROPERLY SEAL ALL EYS FITTINGS IN ALL HAZARDOUS LOCATIONS AS REQUIRED BY 46 CFR 111.105-15(D).
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985
Resolved
PROVIDE ON THE DRILL FLOOR A WATER COOLER WHICH MEET THE REQUIREMENTS CONTAINED IN 46 CFR 111.105-11.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Fire Fighting
Issued 17 January 1985
Resolved
PROVIDE FOR THE FOAM TANK AT THE HELIPORT A REPLACEMENT NAME PLATE AND PROOF THE SYSTEM IS COAST GUARD APPROVED AS PER 46 CFR 108.473(A).
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985
Resolved
ON THE #2 LIFEBOAT RENEW THE DAMAGED INBOARD EXTERIOR FLOAT-LIFELINE.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985
Resolved
ON THE #2 LIFEBOAT MAKE REPAIRS TO THE FORWARD WINDOW GASKET AND HINGE SO AS TO BE CLOSABLE.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985
Resolved
PROVIDE A NEW BATTERY FOR THE EPIRB SO AS TO BE OPERATIONAL AS REQUIRED BY 46 CFR 109.208.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985
Resolved
CONDUCT THE OPERATIONAL TESTS OF LIFEBOATS AND THE WINCH CONTROLLERS AS REQUIRED BY 46 CFR 107.231 (C)AND(D).
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Unknown
Issued 17 January 1985
Resolved
PROVIDE FOR THE EMERGENCY GENERATOR DIESEL OIL TANK A 2 1/2 INCH VENT WITH THE PROPER SIZE FLAME SCREEN AS REQUIRED BY 46 CFR 56.50-85.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985
Resolved
REMOVE THE PLASTIC TIE WRAPS AND INSTALL METAL A MINIMUM OF .5 INCHES WIDE ON THE VERTICAL ELECTRICAL CABLE RUNS AS REQUIRED BY 46 CFR 111.60-5(A)
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985
Resolved
RENEW IN THE STOREROOM LOCATED ON THE STBD AFT LEG ENCLOSURE AND IN WAY OF THE MUD RETURN TROUGH A LIGHT FIXTURE SUITABLE FOR A CLASS I DIV. II LOCATION AS PER 46 CFR 111.105-11
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985