Records from 1984 to 2017. Most recent: inspection, 7 July 2017.
Inspection history · 55
7 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6201343
5 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5735809
3 December 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3373185
17 January 2007
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2857078
25 July 2006
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2725296
5 July 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2420322
29 April 2005
Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2278222
25 April 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2342090
30 August 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2181285
27 August 2002
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1667210
10 July 2002
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1640910
19 July 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467315
15 September 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451608
12 May 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454814
9 February 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766959
27 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 209841
20 July 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391089
16 November 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806960
20 October 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801350
18 September 1997
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1368411
4 September 1997
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1380991
18 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783487
14 October 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847857
17 September 1996
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1438485
31 July 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770773
27 July 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 195356
18 August 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440972
28 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 139467
3 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377250
8 January 1994
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 853854
15 December 1993
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849005
25 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676770
22 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 41764
5 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 170671
24 August 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432758
1 December 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1139615
6 August 1992
COI Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460606
30 October 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676779
12 August 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936057
8 August 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246548
2 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908910
1 February 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1302848
9 August 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217918
17 August 1989
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1031271
17 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343902
22 August 1988
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1344629
11 August 1988
MARPOL Annex II Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345892
15 October 1987
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1015315
13 August 1986
Credit Drydock · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 987077
4 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294590
17 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979989
2 August 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1282004
21 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972945
15 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281944
19 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1285009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 January 2007
Resolved
Install breaker or breaker blank in wheelhouse breaker panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Steering Gear System › Follow-up Assembly
Issued 26 January 2007
Resolved
When steering operated in follow-up mode, rudder swings hard over to port regardless of steering command.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Documentation › Certificates/Documents › International Load Line Certificate
Issued 26 January 2007
Resolved
Provide loadline certificate referencing correct stability letter date. Current stability letter is dated 21 April 2005.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 26 January 2007
Resolved
Make repairs to port and starboard shaft tachs, both in wheelhouse indicators as well as engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 26 January 2007
Resolved
Provide proper alchohol test kit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 January 2007
Resolved
Make repairs to bilge alarm sensors. Bilge level sensor in rudder room compartment is not affixed to bulkhead, causing sensor to move with pitch/roll of vessel. Marks on bulkhead show this condition has existed for quite some time. Sensor in forward passageway IVO bowthruster prime mover not working.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 January 2007
Resolved
Remove all oily bilge contents from engine room and forward passageway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 26 January 2007
Resolved
Properly adjust port and starboard shaft packings. Both shaft packing glands pouring water, not dripping as is standard. Double nut all studs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Thrusters › Pump
Issued 26 January 2007
Resolved
Properly seal all leaks and provide proper cap for oil head tank located in main deck forward berthing space. Clean or remove any oil soaked furniture and decking.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 January 2007
Resolved
Properly secure all televisions, chest freezer and microwave aboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Provide means to prevent progressive flooding through air condtioner drain on main deck air handler located adjacent to engine room door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 January 2007
Resolved
Seal potable water pump. Potable water pump is leaking from shaft seal and/or pump housing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 26 January 2007
Resolved
Seal all openings in potable water pump electrical controller enclosure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2007
Resolved
Properly wire electrical connection for welding machine. Existing wiring orginates in forward passageway breaker panel, where it exits without use of CGB fitting. Wire then is zip tied to overhead frame gussets and terminates at receptacle, again with no CGB fitting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Install new hard rubber gasket in forward engine room door. Existing gasket has approximately 1/2" gap at gasket joint at bottom of door, rendering door not water tight. Adjust upper right hand door dog, right hand center dog and lower left hand dog (all positions relative to facing aft with door closed). Old paint undisturbed on door wedge plates showing this door not secured regularly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 January 2007
Resolved
Secure or remove filing cabinet in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Steering Gear System › Feedback Unit
Issued 26 January 2007
Resolved
Label all indicator lights and switches on steering alarm/control panel in engine room. Provide covers for lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Pipe port and starboard seachest vent in engine room to exterior of vessel. Penetration shall have proper cut out valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 January 2007
Resolved
Provide machinery guard for fuel oil transfer pump cooling fan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 26 January 2007
Resolved
Adjust port and starboard generator to trip at approximately 64.5 cycles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Label all watertight doors "Watertight Door - Keep Closed Except for Passage"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Renew hinge pins, renew hard rubber gasket and properly adjust rudder compartment watertight door. Found door wired open, vessel crew unable to close door without use of wire cutting pliers. Once door released, door unable to dog due to worn hinge pins/pin brackets & adjustment. Paint undisturbed on door wedge plates, providing evidence this door has not been closed in quite some time.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 26 January 2007
Resolved
Properly remount starboard rudder room overhead light fixture.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 26 January 2007
Resolved
Provide globe and shield for port rudder room light fixture.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2007
Resolved
Properly secure or remove excess armored cable found on port side in rudder room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 26 January 2007
Resolved
Clean out/remove all rust and debris from rudder compartment vent pipe. Found vent pipe completely blocked with rust, not allowing compartment to ventilate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Fuel Oil Service System › Vent Pipe
Issued 26 January 2007
Resolved
Correct vent flame screens on sewage, three fuel oil, hydraulic fluid and lube oil tank vents. Provide ball check for hydraulic fluid tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 26 January 2007
Resolved
Clean all lint from clothes dryer vent and provide proper vent closure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 26 January 2007
Resolved
Provide maintenance to all compartment ventilation closures. Found closures siezed or extremely difficult to operate. No evidence of any recent maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 26 January 2007
Resolved
Label electrical switch on Focsle and properly seal switch box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2007
Resolved
Secure armored cable on focsle deck ivo anchor windlass port side. Found armored cable coiled on deck with exposed wire ends.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 26 January 2007
Resolved
Renew entire anchor windlass power supply cable. Found incorrect wire splice in forepeak, armored cable deteriorated and chaffing. Demonstrate anchor windlass operation upon completion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 January 2007
Resolved
Properly resecure forepeak anchor windlass power cable junction box. Found junction box hardward corroded and had fallen from overhead, hanging on power cable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Properly seal starboard side collision bulkhead penetrations .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 26 January 2007
Resolved
Provide Coast Guard approved automation test procedures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Properly insert port exhaust stack overhead in way of damage. Found inset at joint of overhead and outboard side shell causing weld to fail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 26 January 2007
Resolved
Make proper repairs to port generator exhaust piping at overhead. Found approximately 1/4" hole in exhaust pipe, amount of soot evident system has been breached for long period of time.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 26 January 2007
Resolved
Professionally clean port and starboard generator armatures.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 26 January 2007
Resolved
Properly secure all void and tank covers. Found several voids and tanks installed with twelve studs only having 5-7 installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Stability › Watertight Integrity › General
Issued 26 January 2007
Resolved
Remove all splash zone epoxy temporary repairs from bilge/ballast piping. Make proper repairs and test in presence and satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Engineering › Fuel Oil Service System › Vent Pipe
Issued 26 January 2007
Resolved
Remove all splash zone from fuel tank vents, make proper repairs to satisfaction of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 January 2007
Resolved
Provide current original certificate of documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2007
Resolution: Vessel produced laminated copy of COD after considerable searching.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 17 January 2007
Resolved
Vessel to provide complete Int'l Loadline Certificate and documentation of annual loadline surveys. If annual surveys not completed within 90 window of certificate date, loadline certificate is cancelled as per 46 CFR 42.07-55(b)(5).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 17 January 2007
Resolved
Provide current radio safety certificate and Bridge to Bridge act certificate, with correct call sign prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Documentation › Logs/Records › Logbook (official)
Issued 17 January 2007
Resolved
Provide documentation of payment of 2005 and 2006 vessel inspection fees.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Documentation › Certificates/Documents › FCC SSL
Issued 17 January 2007
Resolved
Provide current, correct radio safety certificate and bridge to bridge act certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2007
Documentation › Logs/Records › Logbook (official)
Issued 17 January 2007
Resolved
Provide documentation of satisfactory payment of 2005 and 2006 vessel inspection fees.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 25 July 2006
Resolved
Fire dampers on vent stack will not close properly and need new gaskets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2006
Resolved 27 July 2006
Resolution: Replaced all gaskets and repaired hinges to allow proper operation.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 July 2006
Resolved
COD needs to be updated to reflect new ownership.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 1 August 2006
Resolution: Issued new COD by document center
Communications › Radio Communications › VHF Radiotelephone
Issued 25 July 2006
Resolved
Radio certs need to be updated to reflect new ownership.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 5 October 2015
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 July 2006
Resolved
See attached worklist.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 20 August 2006
Resolution: reprepaired EPIRB/ name added to life jacket/ SOLAS tape renewed on lifering
Construction/Loadline › Hull › Hull Plating
Issued 5 July 2005
No resolution recorded
Crop and renew plate iwo port side chain locker spurling pipe.
Condition: Improper/Lack of Maintenance
Due 10 August 2005 — due date passed with no resolution recorded
Construction/Loadline › Hull
Issued 10 July 2002
Resolved
Numerous hull exam call-outs done during inspection, all listed in narrative. Not listed, and found during RIN, was wastage of the leg support for the mainmast. The portion of the support was cropped and renewed.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2002
Resolved 6 August 2002
Resolution: New steel inserted correctly.
Deck/Cargo › Mooring/Anchoring
Issued 10 July 2002
Resolved
Anchor windlass motor overloaded the SSG. A normal test of the anchor windlass tripped the breaker. Subsequent attempts to lift the anchor caused the ammeter to exceed its maximum gauge reading and caused the ship's lighting to flicker. 835 given with 30 days to rectify it.
Condition: Unknown
Due 6 September 2002
Resolved 27 August 2002
Lifesaving
Issued 20 October 1998
Resolved
Provide GFI outlets to galley and restroom sinks
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Accommodation/Occupational Safety
Issued 20 October 1998
Resolved
Provide register to vent in "OS" berthing area
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Engineering
Issued 20 October 1998
Resolved
Provide guard over stbd shaft
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Engineering
Issued 20 October 1998
Resolved
Repair lagging to stbd mde exhaust piping
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Deck/Cargo
Issued 20 October 1998
Resolved
Resplice/repair eyesplice to rescue boat lifting cable
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Accommodation/Occupational Safety
Issued 20 October 1998
Resolved
Provide proper drain pipie to galley sink
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Engineering
Issued 17 September 1996
Resolved
REPLACE METAL GUARDS ON FUEL FILTERS ON BOTH MAIN ENGINES AND PORT GEN.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Construction/Loadline
Issued 17 September 1996
Resolved
CROP AND RENEW WASTED FRAMES IN PORT AFT WRAP TANK.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Accommodation/Occupational Safety
Issued 17 September 1996
Resolved
MAKE PERMANET REPAIRS TO SEWAGE OVERBOARD PIPE ABOVE BOWTHRUSTER ENGINE.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Engineering
Issued 17 September 1996
Resolved
REPAIR REACH RODS FOR REMOTE FUEL SHUT OFF VALVES.
Condition: Unknown
Due 17 September 1996
Resolved 20 September 1996
Engineering
Issued 17 September 1996
Resolved
REPLACE WASTED EXHAUST EXPANSION JOINT ON STBD GEN.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Construction/Loadline
Issued 17 September 1996
Resolved
REPAIR BROKEN WELDS IN STBD AFT WRAP TANKS.
Condition: Unknown
Due 17 September 1996
Resolved 17 September 1996
Fire Fighting
Issued 1 February 1991
Resolved
REPAIR AND PROVIDE REQUIRED EQUIPMENT ON ALL FIRE STATIONS. REMOVE OR SERVICE UNSERVICABLE FIRE FIGHTING EQUIPMENT. VESSEL MAY NOT GET UNDERWAY UNTIL THIS REQUIREMENT IS COMPLETED. VESSEL MAY MOVE IN CASE OF EMERGENCY, SUCH AS PIER FIRE ETC. OR TO ALLOW OTHER VESSELS BERTHING.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Engineering
Issued 11 August 1988
Resolved
PROVE PROPER OPERATION OF PORT MAIN ENGINE REMOTE SHUTDOWN.
Condition: Unknown
Due 11 August 1988
Resolved 11 August 1988
Engineering
Issued 11 August 1988
Resolved
PROVE PROPER OPERATION OF REMOTE FUEL OIL SHUT-OFF VALVE FOR STARBOARD DAYTANK
Condition: Unknown
Due 11 August 1988
Resolved 11 August 1988
Engineering
Issued 11 August 1988
Resolved
PROVE PROPER OPERATION OF PORT SHAFT TACH
Condition: Unknown
Due 11 August 1988
Resolved 11 August 1988
Navigation
Issued 11 August 1988
Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR IN ENGINE ROOM.
Condition: Unknown
Due 11 August 1988
Resolved 11 August 1988
Unknown
Issued 4 September 1985
Resolved
PROVIDE AN EMERGENCY MEANS TO SECURE THE FLOW OF PRODUCT THROUGH THE LIQUIDMUD PIPING SYSTEM IN ACCORDANCE WITH TITLE 33 CODE OF FEDERAL REGULATIONS, PART 155.780. THE MEANS PROVIDED MUST BE INCLUDED IN THE VESSEL'S OIL TRANSFER PROCEDURES AND SUBMITTED TO THE LOCAL MARINE INSPECTION DETACHMENT
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Unknown
Issued 4 September 1985
Resolved
PROVIDE ADEQUATE FIXED OR PORTABLE CONTAINMENT FOR FUEL OIL VENTS.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Deck/Cargo
Issued 17 July 1985
Resolved
PROVIDE ADEQUATE CONTAINMENT FOR FUEL OIL VENTS.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Deck/Cargo
Issued 17 July 1985
Resolved
PROVIDE REMOTE SHUT DOWN FOR LIQUID MUD PUMP.
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Unknown
Issued 17 July 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DELTA EXPRESS DN650228
Condition: Unknown
Due 17 July 1985
Resolved 17 July 1985
Deck/Cargo
Issued 2 August 1984
Resolved
FIX P-TANK COMPRESSOR OVERSPEED TRIP
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Lifesaving
Issued 2 August 1984
Resolved
PROVIDE 1 SERVICE LINE FOR LINE THROWING GUN (4 TOTAL)
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Fire Fighting
Issued 2 August 1984
Resolved
REPLACE OR REPAIR FIRE PLAN FOR VESSEL ( FADED OUT )
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Unknown
Issued 2 August 1984
Resolved
REPLACE OR REPAIR PORT GENERATOR TACH AND BOW THRUSTER ENGINE TACH-VFOD,U
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Documentation
Issued 2 August 1984
Resolved
VESSEL DOCUMENT REQUIRES UPDATING (NEW STICKER)
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Unknown
Issued 21 May 1984
Resolved
PROVIDE ON BOARD CURRENT COPIES OF THE RULES OF THE ROAD, 46 CFR SUBCHAPTERI, LIGHT LIST, TIDE/CURRENT TABLES, & COAST PILOT.
Condition: Unknown
Due 21 May 1984
Resolved 21 May 1984
Unknown
Issued 19 April 1984
Resolved
INSTALL STARBOARD MISSING ANCHOR.
Condition: Unknown
Due 19 April 1984
Resolved 19 April 1984