MAURY USCG vessel records Sign in
← All vessels

MERIT

MERIT is a 1982 passenger vessel (uninspected). The Coast Guard has recorded 42 inspections since 1985, most recently in March 2003, along with 76 deficiencies.

Records from 1985 to 2003. Most recent: inspection, 6 March 2003.

Built
1982
Last inspected
6 March 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRP5557
Flag
UNITED STATES
—
Maury page id
psix-54550

Inspections, by type

…with no type recorded9
Years with a record 18 calendar years (1985–2003)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

6 March 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1750494
1 April 2002 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1599043
17 October 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362486
14 June 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423685
18 May 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1065640
2 January 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643611
14 December 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372929
11 June 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404778
2 November 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404633
4 November 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1431871
15 October 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1110914
11 June 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1109491
14 May 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364131
4 April 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1091587
28 October 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445133
3 November 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367557
1 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1186482
17 August 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643610
25 May 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 213188
25 May 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1394330
25 October 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1422434
9 December 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377092
3 November 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828840
16 July 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 847474
26 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 841438
15 February 1993 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1145625
13 January 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1137932
22 October 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253163
28 October 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1247095
20 June 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897677
26 December 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 914950
30 November 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1212152
1 November 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 980698
20 October 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1196592
24 October 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1200467
14 December 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1311322
19 November 1987 Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1026468
18 August 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030799
8 September 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335662
18 November 1985 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990916
13 November 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302612
8 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 981047

Deficiency record · 76

Lifesaving › Rigid Liferafts › Weak Link
Issued 6 March 2003 Resolved
The weak link from the painter to the hull of the vessel was not attached properly.
Action required: 705 - Other - as specified
Resolved 6 March 2003
Resolution: Attached the weak link properly.
Lifesaving › Rigid Liferafts › Painter
Issued 6 March 2003 Resolved
The painter itself was in poor condition and needs to be replaced.
Action required: 705 - Other - as specified
Resolved 6 March 2003
Resolution: The painter was replaced.
Lifesaving › Rigid Liferafts
Issued 6 March 2003 Resolved
First raft was not attached to the second raft.
Action required: 705 - Other - as specified
Resolved 6 March 2003
Resolution: First raft was attached to the second raft.
Communications › Radio Communications › EPIRB
Issued 6 March 2003 Resolved
EPIRB was sent ashore to have battery replaced.
Action required: 705 - Other - as specified
Resolved 6 March 2003
Resolution: EPIRB was installed with new battery.
Documentation › Certificates/Documents
Issued 1 April 2002 Resolved
Provide LOSC and MIS submitted accordingly as per 46 CFR part 16. Cleared LOSC requirement on 19 APR 02 but MIS for 2001 remains outstanding.
Due 16 April 2002
Resolved 6 March 2003
Resolution: Cleared MIS for 2001 requirement.
Electrical
Issued 1 April 2002 Resolved
Radar unit not hooked up and loose wiring from 3 other navigational systems under ops station.
Due 1 April 2002
Resolved 1 April 2002
Resolution: Corrected before inspection complete.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 1 April 2002 Resolved
One hose clamp missing on engine cooling intake system. Corrected before inspection complete.
Due 1 April 2002
Resolved 1 April 2002
Resolution: Corrected before inspection complete.
Documentation › Markings/Placards
Issued 1 April 2002 Resolved
Waste management plan missing. Corrected before inspection complete.
Due 1 April 2002
Resolved 1 April 2002
Resolution: Corrected before inspection complete.
Documentation › Manuals/Policy Documentation
Issued 1 April 2002 Resolved
No emergency instruction list posted. Corrected before inspection complete. LEGACY COMPONENT DESC: Emergency Instructions
Due 1 April 2002
Resolved 1 April 2002
Resolution: Corrected before inspection complete.
Documentation › Manuals/Policy Documentation
Issued 1 April 2002 Resolved
Tide tables missing. Corrected before inspection complete.
Due 1 April 2002
Resolved 1 April 2002
Resolution: Corrected before inspection complete.
Documentation › Logs/Records
Issued 1 April 2002 Resolved
Provide proof of first aid/CPR training/certification for 50% of crew as per NVIC 1-91.
Due 16 April 2002
Resolved 19 April 2002
Resolution: Company provided employees with training today.
Lifesaving › Launching Appliances
Issued 1 April 2002 Resolved
Renew expired hydrostatic release (expired 2/2002) for EPIRB as per 46 CFR 180.64. Vessel is restricted to within 3NM from shore until corrected to the satisfaction of a Marine Inspector. LEGACY COMPONENT DESC: Release Mechanism
Due 16 April 2002
Resolved 19 April 2002
Resolution: New release purchased.
Lifesaving
Issued 1 April 2002 Resolved
Paddles not tethered to float and one paddle needs name stenciled legibly. LEGACY COMPONENT DESC: lifefloat equipment
Due 1 April 2002
Resolved 1 April 2002
Lifesaving
Issued 1 April 2002 Resolved
Children PFD storage space incorrected marked. Corrected before inspection complete. LEGACY COMPONENT DESC: PFD storage space
Due 1 April 2002
Resolved 1 April 2002
Electrical
Issued 1 April 2002 Resolved
Loose wiring in engine room. Corrected before inspection complete. LEGACY COMPONENT DESC: Engine room
Due 1 April 2002
Resolved 1 April 2002
Engineering
Issued 14 June 2001 Resolved
Port and Starboard cutlass bearings worn. Port side 50% wasted, starboard side 100% wasted.
Condition: Unknown
Due 1 July 2001
Resolved 21 November 2001
Engineering
Issued 14 June 2001 Resolved
Starboard side shaft tube and strut were damaged.
Condition: Unknown
Due 1 July 2001
Resolved 21 November 2001
Construction/Loadline
Issued 14 June 2001 Resolved
Remove the toilet and all related through hull piping.
Condition: Unknown
Due 1 July 2001
Resolved 21 November 2001
Construction/Loadline
Issued 14 June 2001 Resolved
Vent screens to engine room appeared to be kicked in.
Condition: Unknown
Due 1 July 2001
Resolved 21 November 2001
Engineering
Issued 14 May 1997 Resolved
Renew port cutlass bearing prior to returning the vessel to the water.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Documentation
Issued 4 April 1997 Resolved
Provide a Certificate of Documentation for vessel or provide evidence that vessel is less than 5 net tons. (Admeasurement must be performed by ABS orDNV).
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Documentation
Issued 28 October 1996 Resolved
Provide a vaild FCC station license.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Electrical
Issued 28 October 1996 Resolved
Remove all open ended and unused wire, and ensure all wires are properly secured, throughout the vessel.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Electrical
Issued 28 October 1996 Resolved
Provide and install a portable battery light for the machinery space as required by 46 CFR 183.430.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 28 October 1996 Resolved
Provide a proper flare box that is bright in color and is marked as per 46 CFR 185.614.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Electrical
Issued 28 October 1996 Resolved
Ensure there are fuses properly installed in the fuse panel for all systems.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 28 October 1996 Resolved
Perform proper maintenance on the ring buoy and buoyant apparatus.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Accommodation/Occupational Safety
Issued 28 October 1996 Resolved
Repair or replace the hand pump for the MSD system.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Lifesaving
Issued 1 September 1995 Resolved
Provide a water light for the buoyant apparatus prior to carrying more thansix passengers as discussed with the master [name withheld] on 01SEP95.
Condition: Unknown
Due 6 September 1995
Resolved 6 September 1995
Construction/Loadline
Issued 3 November 1993 Resolved
PROVIDE REPAIRS TO CRACKED WELDS IN WAY OF THE RADOME PROTECTION CAGE.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Lifesaving
Issued 3 November 1993 Resolved
PROVIDE WORKING WATERLIGHT, PROPER RETROREFLECTIVE MATERIAL AND MARKINGS TOBUOYANT APPARATUS. VESSEL IS NOT TO SAIL WITH PASSENGERS TILL CORRECTED.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Navigation
Issued 3 November 1993 Resolved
UPDATE LOCAL OPERATING AREA CHARTS.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Documentation
Issued 3 November 1993 Resolved
PROVIDE EVIDENCE OF RANDOM CHEMICAL TESTING PROGRAM IN PLACE WITH RESULTS.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Lifesaving
Issued 3 November 1993 Resolved
PROVIDE SEVEN ADDITIONAL LIFE PRESERVERS. VESSEL IS LIMITED TO 24 PERSONS ABOARD UNTIL CORRECTED.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Engineering
Issued 3 November 1993 Resolved
PROVIDE PROPER HANDLE FOR PORT EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 10 November 1993
Resolved 10 November 1993
Engineering
Issued 26 April 1993 Resolved
PROVE PROPER OPERATION OF STARBOARD ENGINE AFTER INSTALLATION.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Construction/Loadline
Issued 26 April 1993 Resolved
REPAIR RUB RAIL WHERE SEPARATED ON PORTSIDE.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Accommodation/Occupational Safety
Issued 22 October 1992 Resolved
PROVIDE PROPER OPERATION OF THE MARINE SANITATION SYSTEM.
Condition: Unknown
Due 29 October 1992
Resolved 23 October 1992
Navigation
Issued 22 October 1992 Resolved
PROVIDE ALL NAUTICAL PUBLICATIONS AND CHARTS AS REQUIRED BY _x001C_ 46 CFR 185.20-35.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Lifesaving
Issued 22 October 1992 Resolved
PROVIDE FIVE ADDITIONAL DAY SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 29 October 1992
Resolved 23 October 1992
Accommodation/Occupational Safety
Issued 28 October 1991 Resolved
REATTACH STERN RAIL TO DECK, LOCATED ON STARBOARD SIDE NEAREST CENTERLINE.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Accommodation/Occupational Safety
Issued 28 October 1991 Resolved
INSTALL WINDOW IN AFTER WINDOW FRAME, STARBOARD SIDE.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Navigation
Issued 20 June 1991 Resolved
DOUBLE NUT STARBOARD RUDDER AT CONTROL ARM.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Navigation
Issued 20 June 1991 Resolved
REPLACE HOSE ON PORT RUDDER POST.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Engineering
Issued 20 June 1991 Resolved
PROVIDE COTTER PIN FOR PORT PROP NUT.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Engineering
Issued 20 June 1991 Resolved
REPLACE HOSE ON STARBOARD ENGINE HEAT EXCHANGER.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Construction/Loadline
Issued 20 June 1991 Resolved
CLEAN AND GRIND AREA FORWARD ON STARBOARD SIDE OF BOW AND CLAD WELD PITTED AREA.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Lifesaving
Issued 30 November 1990 Resolved
LABEL LIFE JACKET LOCKERS WITH NUMBER OF JACKETS IN EACH AS PER 46 CFR 180.25-15(B).
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Accommodation/Occupational Safety
Issued 30 November 1990 Resolved
RENEW BROKEN WINDOW PORT SIDE.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990 Resolved
PROVIDE SIX (6) ADULT PFDS WITH RETROREFLECTIVE TAPE. THE NUMBER OF PASSENGERS IS REDUCED TO 21 UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Electrical
Issued 1 November 1989 Resolved
REPAIR OR REPLACE BATTERY BOX, PORT SIDE, AND INSURE IT IS LINED WITH A MATERIAL RESISTANT TO ELECTROLYTE.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Engineering
Issued 1 November 1989 Resolved
REPLACE RUSTED DRY EXHAUST PIPING: TWO ON STBD SIDE AND ONE INBOARD PORT SIDE WITH APPROVED MATERIAL.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 1 November 1989 Resolved
OPEN ALL DECK ACCESS PLATES TO UPPER VOID SPACE, EMPTY OF LIQUID. MARINE INSPECTOR TO EXAMINE DRY VOIDS PRIOR TO MAKING WATERTIGHT. REATTACH RUB RAIL AND MAKE ALL ATTACHMENTS WATERTIGHT.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 1 November 1989 Resolved
PLUG THROUGHHULL PENETRATION ON STBD SIDE AFT, ABOVE THE WATERLINE.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Documentation
Issued 1 November 1989 Resolved
PROVIDE A CURRENT RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Construction/Loadline
Issued 20 October 1989 Resolved
REPLACE BROKEN WINDOW IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Accommodation/Occupational Safety
Issued 20 October 1989 Resolved
REPAIR OR REMOVE HANDRAIL FROM LADDER AT DECKHOUSE TOP.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Navigation
Issued 20 October 1989 Resolved
REPLACE STARBOARD SIDELIGHT LENS.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Navigation
Issued 20 October 1989 Resolved
REPAINT STARBOARD SIDELIGHT SCREEN MATTE BLACK.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Construction/Loadline
Issued 24 October 1988 Resolved
INSTALL CAPTURE CHAIN FORWARD ON ANCHOR COMPARTMENT HATCH COVER.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Accommodation/Occupational Safety
Issued 24 October 1988 Resolved
REPAIR VENTILATION SCREEN TO ENGINE COMPARTMENT, PORT SIDE, FORWARD.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Engineering
Issued 24 October 1988 Resolved
REPLACE SHROUD COVERING ON FUEL LINE, STBD, AT EMERGENCY VALVE CONNECTION.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Lifesaving
Issued 24 October 1988 Resolved
RESTENCIL NAME ON PADDLE AND BA.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Construction/Loadline
Issued 24 October 1988 Resolved
REFASTEN RUB RAIL PORT AND STBD SIDE NEAR THE BOW.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Lifesaving
Issued 24 October 1988 Resolved
REPLACE RING BUOY.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Engineering
Issued 24 October 1988 Resolved
SECURE FUEL RETURN LINE TO STBD ENGINE.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Engineering
Issued 19 November 1987 Resolved
REPLACE VESSEL'S FUEL TANK FLEXIBLE HOSES IN WAY OF THE FORWARD FILL PIPE AND THE STARBOARD DISCHARGE PIPE. REPLACEMENT IS TO BE IN ACCORDANCE WITH 46 CFR 182.20-40.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Construction/Loadline
Issued 19 November 1987 Resolved
IN ACCORDANCE WITH 46 CFR 176.25-50, REMOVE & CLEAN ENGINEROOM BILGES.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Documentation
Issued 19 November 1987 Resolved
PROVIDE A COPY OF U.S. WATER TAXI'S OPERATOR'S FCC RADIO OPERATOR LICENSE.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Construction/Loadline
Issued 18 August 1987 Resolved
OPEN AND CLEAN RUB RAIL VOIDS.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Documentation
Issued 18 August 1987 Resolved
PROVIDE CORRECTED COPIES OF FCC PERMITS & CERTIFICATES.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Construction/Loadline
Issued 18 August 1987 Resolved
REPAIR FRACTURED LIFE RAILS.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Unknown
Issued 8 September 1986 Resolved
REPLACE CRACKED WINDOW, STARBOARD SIDE FORWARD.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Lifesaving
Issued 13 November 1985 Resolved
LABEL LIFE PRESERVER STORAGE BINS.
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Documentation
Issued 13 November 1985 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Engineering
Issued 13 November 1985 Resolved
REPAIR OIL LEAK IN PORT AND STARBOARD ENGINES.
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985

Ownership record