08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 August 2018
No resolution recorded
Bilge alarm located in the #2 port side bilge failed to energize audible and visual alarm at the operators station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2018
No resolution recorded
Vapor sensors failed to indicate if flammable vapors were present.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 August 2018
No resolution recorded
Unable to operate the generator due to it triping electrical breakers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2018
No resolution recorded
Transmission arm rocker on port side is held together with a zip tie. Needs to be permanent attachement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 August 2018
No resolution recorded
Unable to run fire drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 August 2018
No resolution recorded
Unable to run Man Overboard Drill.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 August 2018
No resolution recorded
Vents for gasoline fuel tanks, engines, and generator were near the top of storage areas vice in bilges to ensure flammable vapors were vented out of the space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 August 2018
No resolution recorded
Electrical wires that were deadended in a hazardous zone need to be removed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Deck Plating
Issued 19 July 2017
No resolution recorded
Fiberglass Soft patch on the bow deck has failed causing additional soft spots throughout the deck of the bow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2017 — due date passed with no resolution recorded
Resolution: To the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 19 July 2017
No resolution recorded
Unable to test starboard side bilge alarm panel not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2017 — due date passed with no resolution recorded
Resolution: To the satisfaction of the attending marine inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 19 July 2017
No resolution recorded
Lifering is deteriorated and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2017 — due date passed with no resolution recorded
Resolution: To the satisfaction of the attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 July 2017
No resolution recorded
Replace Retroreflective Material on all lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2017 — due date passed with no resolution recorded
Resolution: To the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Deck Plating
Issued 8 August 2016
No resolution recorded
Fiberglass soft patck on main deck foward is failing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Not Operational
Issued 8 August 2016
No resolution recorded
Bilge alarm pannel not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2016 — due date passed with no resolution recorded