ISLAND SPIRIT

ISLAND SPIRIT is a 1973 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1985, most recently in February 2026, along with 164 deficiencies, 1 operational control and 6 casualty investigations between 2002 and 2018.

Records from 1985 to 2026. Most recent: inspection, 27 February 2026.

Built
1973
Last inspected
27 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG6063
Flag
UNITED STATES
368272050
Maury page id
psix-54566

Inspections, by type

…with no type recorded10
Years with a record 38 calendar years (1985–2026)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.8 ft × 18.5 ft × 7.0 ft
Registered tonnagegross 22 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCSK CO · VENICE, CA, UNITED STATES · built 1973
Hull materialWood
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN3479MMSI 368272050 · active · compulsorily equipped · granted 11 August 2022, expires 11 August 2032
WDG6063MMSI 367553120 · expired · compulsorily equipped · granted 9 November 2012, cancelled 14 January 2023
WDA8199MMSI 366851770 · expired · voluntarily equipped · granted 10 May 2002, cancelled 14 July 2012
WCZ7113MMSI not assigned · expired · voluntarily equipped · granted 16 March 2000, cancelled 22 May 2010
WCO8481MMSI not assigned · expired · compulsorily equipped · granted 9 July 1998, cancelled 22 January 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 89

27 February 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8317779
2 September 2025 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8225673
15 May 2025 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8130659
24 February 2025 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8084050
25 September 2024 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8008896
11 April 2024 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7875282
1 December 2023 In-Service Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7836298
9 June 2023 Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7689280
27 October 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7353302
4 October 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7327354
12 July 2021 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7254404
11 February 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7139647
16 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7007437
29 October 2019 Drydock Exam · Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6846611
5 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6706117
20 March 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6646282
4 July 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6482926
8 May 2018 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6408497
3 November 2017 Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6299061
11 May 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6143490
3 May 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867697
4 November 2015 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5757559
5 August 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4954818
23 May 2014 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4869859
14 May 2014 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4836177
27 September 2011 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4155456
21 September 2011 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4151249
23 August 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4125040
20 April 2009 Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3457014
2 May 2008 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3191426
23 October 2007 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3086271
12 July 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2993013
20 March 2007 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2891731
14 June 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2726975
3 November 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2527669
1 April 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2324133
21 April 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2036328
3 March 2004 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2017350
1 March 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2018400
31 January 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1999263
17 November 2003 Administrative Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1943467
26 June 2003 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1903072
25 April 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1762995
24 July 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1833480
12 April 2002 Administrative Inspection · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1496115
8 January 2002 Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1485319
4 April 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1433817
11 September 2000 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822310
8 August 2000 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361637
4 April 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048340
29 March 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381852
17 March 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048395
24 December 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365497
8 June 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369225
18 June 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1396939
22 May 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416718
8 May 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371802
15 January 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1424324
11 July 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1095400
15 May 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380539
15 November 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1458247
3 July 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355327
19 May 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1454225
20 May 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353575
17 December 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1439464
15 November 1993 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1399941
31 August 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1135382
19 August 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 846898
17 June 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 844376
24 July 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1256871
20 May 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 951352
30 July 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1250385
31 May 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1198956
21 December 1990 Hull Examination · Plan Review "T" Boat
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 928902
13 June 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1226052
17 November 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1219331
6 June 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1208943
6 October 1988 Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 897750
1 June 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1035068
8 September 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1315572
17 July 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1328620
8 June 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004989
30 October 1986 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1321413
5 June 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990494
19 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 980994
6 July 1985 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978204
7 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288994
30 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976967
25 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1286437

Deficiency record · 164

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 July 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with the manufacturer's instructions. Gap in port side forward machinery space boundary allows the passage of vapors. Make vapor tight to ensure quantity of extinguisher is sufficient for space. Resolve by July 18, 2025 to the satisfaction of the attending marine inspector. 46 CFR 181.420(a)(4)
Action required: 705 - Other - as specified
Resolved 18 July 2025
Resolution: Spaces made vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2025 Resolved
Spaces containing machinery shall be fitted with at least two ducts to furnish natural or mechanical supply and exhaust ventilation. Operator unable to identify location of the two ducts where port side main engine draws ventilation. Demonstrate adequate ventilation or install in accordance with 46 CFR 182.20-45 (OLD T Regulations). 46 CFR 182.20-45 (c) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 28 July 2025
Resolution: Appropriate ventilation identified.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 July 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel mast light and stern light is not in compliance with Navigation Rule 23. Install navigation lights in accordance with 33 CFR 83.22(d) (Rule 23) for a vessel of less than 12 meters to the satisfaction of the MI. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 28 July 2025
Resolution: Anchor light wired in.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2025 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. Vessel's name and hailing port markings missing on port side and stern. Replace with markings of appropriate size as described by 46 CFR 67.123(a)(d) to the satisfaction of the attending Marine Inspector. 46 CFR 185.602(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 28 July 2025
Resolution: Markings replaced both sides.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 July 2025 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions an information, specific to the individual vessel. Placard not located next to radiotelephone installation. Install next to radiotelephone. 46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 28 July 2025
Resolution: Emergency broadcast instructions posted next to radiotelephone.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 July 2025 Resolved
A person may not employ or engage an individual in a position required to hold and MMC unless that individual maintains a current medical certificate. 01 employee (EMERSON HILLEN) serving as captain unable to produce proof of current medical certificate. Employee may not operate in capacity of captain until valid medical certificate is provided to the attending Marine Inspector. 46 CFR 15.401(c)
Action required: 705 - Other - as specified
Resolved 9 September 2025
Resolution: Received medical cert.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 July 2025 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: Navigation equipment and lights. Existing all-around anchor light only powered by battery. Install appropriate navigation light in accordance with this regulation to the satisfaction of attending marine inspector. 46 CFR 183.310(a)(1)(iv)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2025
Resolved 28 July 2025
Resolution: Anchor light wired in.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 May 2025 Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of the vessel. Area of plywood separation discovered in starboard aft compartment inner hull at waterline. Uncover and present for inspection at drydock. 46 CFR 177.10-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: Attended vessel and instructed the contractor to drill two core samples from the aft inboard port hull just above the port propeller and aft near the wing deck to hull transition to determine plywood thickness to determine repair options.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 May 2025 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the [name withheld] repairs present on the port side hull. Uncover and present for inspection at drydock. 46 CFR 176.20-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2025
Resolution: Inspected identified hull areas that had been opened up.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 September 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to affect permanent repairs. the OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition. Vessel has 8 foot crack on exterior of starboard hull in way of wing deck causing water intrusion into starboard hull. Vessel restricted from carrying passengers until adequate repairs are completed during drydock and are accepted by a USCG Marine Inspector. 46 CFR 176.600(d) 701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2024
Resolution: Vessel affected satisfactory repairs to damaged area.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Unauthorized electrical connections identified between electrical wires. 46 CFR 183.200 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2024
Resolution: Butt connectors properly installed onto electrical connections.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Port bilge visual indicator is not operational. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 25 April 2024
Resolution: Fixed inop bilge alarm visual indicator.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol. 46 CFR 4.06-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 25 April 2024
Resolution: Provided presence of alcohol test kits to the USCG.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 April 2024 Resolved
All fuel tanks must be electrically bonded to a common ground. Grounding wire for port fuel tank is missing. 46 CFR 182.440(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2024
Resolved 25 April 2024
Resolution: Installed grounding wire.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Battery was found having six connections on each terminal. Reduce number of connections to a maximum of four. 46 CFR 183.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2024
Resolved 25 April 2024
Resolution: Installed terminal board to organize and reduce number of connections on battery.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 December 2023 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel reported damage to a cleat on the forward part of the starboard sponson. Damage is a potential source of water ingress. Make repairs in accordance with discussed plans. 46 CFR 177.300(c)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2023
Resolution: Vessel completed repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 December 2023 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel reported damage to the hull where the damaged drain line was leaking. Submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2023
Resolution: Vessel submitted repair proposals and completed the repairs to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed per the manufacturer's instructions. The provided fixed extinguishing system in the port engine room is rated for 75 cuft. The rear bulkhead of the engine room was not reasonably gas tight and allowed for free communication of atmosphere to the port aft shaft space which increased the volume of the compartment in excess of 75 cuft. Provide a reasonably gas tight separation of the spaces.
Action required: 10 - Deficiency Rectified
Resolved 12 July 2023
Resolution: The aft bulkhead of the engine room was made reasonably gas tight which reduced the volume of the engine room to less than 75 cubic feet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2023 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Vessel's steering gear is loose and misaligned in many places. Repair to the satisfaction of the attending marine inspector. 46 CFR 182.610 (a)(1)
Action required: 705 - Other - as specified
Resolved 3 July 2023
Resolution: Vessel reps had technician [name withheld] to reinstall and realign system. Everything was replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 June 2023 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has areas of suspected water damage of fiberglass underneath floor boards in fwd part of vessel, inside cabin area, bow starboard hull, topside aft starboard hull where railing is attached, inside engine room in port hull, and aft right bolt area on starboard side netting. Clean and submit findings with repair proposal. 46 CFR 177.300 (c)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 July 2023
Resolution: Vessel reps completed all necessary repairs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2021 Resolved
A pre-engineered fix gas fire extinguishing system must have a means to reset devices used to automatically shut down ventilation systems & engines. STBD Fireboy failed to reset; prove proper operation to the attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2021
Resolution: Purchased and installed new Fireboy control module. O/O proved proper operation to the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 July 2021 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. Provide 06 hand red flares, and 03 hand orange flares. A red hand flare distress signal can be substituted for any of the hand orange smoke distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2021
Resolution: O/O provided nine red flares and three orange flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
Flexible nonmetallic hose may be used in fuel oil systems subject to the following requirements: USCG Type A1-15. The STBD secondary fuel filter to primary filter supply lines are not intended for fuel injected engines. Change to USCG Type A1-15 or SAE J1527 Marine Fuel Hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: O/O installed equvilent hose on the STBD secondary fuel filter to primary filter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
Where a flexible vent pipe section is necessary, suitable flexible hose having high resistance to petroleum oils may be used. The STBD fuel tank vent hose is not designed for fuel. Change to USCG Type A-2 or SAE J1527 Marine Fuel Hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 31 July 2021
Resolution: Owner installed USCG Type A-2 hose for the STBD fuel tank. Photograph uploaded in deficiencies documents.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 July 2021 Resolved
All vessels must have operable navigation lights IAW the Navigation Rules. Navigation lights are not wired IAW Navigation Rules. The anchor light needs to be rewired separate from other navigation lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: O/O installed an anchor light that is manually turned on and off separate from the navigation lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. The following areas were identified to not meet the vapor tight criteria, to include: the starboard engine space and fuel tank space leading to the storage compartments, as well as the port engine room. Provide a proper seal to prevent the passage of vapors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 4 October 2021
Resolution: MI attended vessel and confirmed the starboard engine space and fuel tank space leading to the storage compartments, as well as the port engine room were properly sealed to prevent the passage of vapors.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 July 2021 Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use. Magnetic compass was not mounted; mount suitable magnetic compass in the vicinity of the operating station and illuminate or vessel is restricted to daytime operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: O/O mounted a suitable magnetic compass in the vicinity of the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at service speeds. The fasteners on the steering ram to rudder tie rod mounting block are corroded, and need to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 31 July 2021
Resolution: Owner installed new fastners with nylon washers and 5200m. Photograph uploaded in deficiencies documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 July 2021 Resolved
A hatch exposed to the weather must be watertight. Some of the weather deck hatches are not watertight, including the port aft hatch. Make all weather deck hatches watertight tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 9 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2021 Resolved
A submersible electric bilge pump may be used as a power bilge pump on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that: The pump meets UL 1113. Install UL 1113 submersible electric bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: O/O installed correct UL 1113 electric bilge pumps and 15 amp overcurrent protection fuses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The Port fuel tank fuel shut off valve does not close all the way. Demonstrate that this shut off valve can close entirely.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. The bonding on the port and STBD fuel fill is in correct or missing; install proper bonding wire to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 9 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2021 Resolved
A vessel inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards covered in this subchapter may be inspected IAW standards acceptable to the cognizant OCMI as good marine practice. The both PSS shaft seal do not have an adequate vent line; provide a suitable vent line IAW the manufacturer installation procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 31 July 2021
Resolution: Owner installed a 4 foot vent hose to both PPS shaft seals. Photograph uploaded in deficiencies documents.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 July 2021 Resolved
A Certificate of Documentation (COD) is required for the operation of a vessel in certain trades, serves as evidence of vessel nationality, and permits a vessel to be subject to preferred mortgages. Vessel Operator could not produce original COD. Provide original COD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2021
Resolution: Operator emailed COD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2021 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets were not stowed separately from adult life jackets. Stow child size life jackets that is separated from adult size life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: O/O stowed child size life jackets separately from adult life jackets by relocating them to the forward STBD salon area and marked as per 46 CFR 185.604(f).
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 July 2021 Resolved
A cable must not be spliced in a hazardous location. STBD engine room 12V red cable is spliced. Install either a single wire or an enclosure IAW 183.340(g).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: O/O installed a covered terminal block as a connection point for the two wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2021 Resolved
Each life jacket, immersion suit, and ring lifebuoy must be marked in clearly legible block capital letters with the vessel's name. 01 ring lifebuoy was not properly labeled with the ship's name. Mark with vessel name.
Action required: 10 - Deficiency Rectified
Due 12 July 2021
Resolved 12 July 2021
Resolution: Owner properly labled ring lifebuoy with a Sharpie in the presence of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 July 2021 Resolved
The master of the vessel shall ensure that: the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB testing not conducted and not loggged. Test EPIRB and log.
Action required: 10 - Deficiency Rectified
Due 12 July 2021
Resolved 12 July 2021
Resolution: Owner tested EPIRB and logged in the presence of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2021 Resolved
The employer shall provide an Employee Assistance Program for all crew members that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Vessel's O/O is establishing an Employee Assistance Program as part of the company's chemical testing program, but has not completed the program. Provide satisfactory evidence of an Employee Assistance Program.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 August 2021
Resolution: Provided Company Policy that included DAPI Section, Zero Tolerance Policy, Master's EAP Training, and evidence of 60 min EAP Crew Training.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2020 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at he operating station: A means to reset devices used to automatically shut down engines. Vessels two pre-engineered systems did not function properly and did not allow engines to restart. 46 CFR 176.810(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 10 August 2020
Resolution: System tested sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 July 2020 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. 46 CFR 185.728
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 10 August 2020
Resolution: Vessel replaced battery and tested sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 July 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing GPS signal for DSC operation. 47 CFR 80.905(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 10 August 2020
Resolution: Vessel purchased new radio with internal GPS and input MMSI
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 July 2020 Resolved
Over current protection must be provided for each ungrounded conductor. An emergency switch must be provided in the normally ungrounded main supply conductor from a battery. Vessel has 12v wire from battery that bypasses emergency switch and has no over current protection. Determine load of conductor and wire appropriately. 46 CFR 183.380
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2020
Resolved 10 August 2020
Resolution: Vessel wired correctly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2019 Resolved
FLEXIBLE NONMETALLIC HOSE PERMITTED FOR USE IN PIPING SYSTEMS MUST MEET SAE J-1942. HYDROLIC HOSES USED IN STEERING SYSTEM DID NOT MEET THE SAE J-1942 STANDARD. REPLACE THE HYDROLIC HOSES USED IN SYSTEM SYSTEM WITH SAE J-1942 STANDARD NONMETALLIC HOSES.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Replaced with J-1942 spec hydraulic hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 May 2019 Resolved
A HATCH EXPOSED TO THE WEATHER MUST BE WATERTIGHT. HATCH COVERS ON OPEN DECK WERE FOUND TO BE MISSING GASKETS RENDURING THEM NOT WATERTIGHT. ENSURE ALL HATCH COVERS HAVE GASKETS IN PLACE AND ENSURE THE WATERTIGHT INTEGRITY OF THE EACH HATCH COVER.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Gaskets replaced to make it watertight.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 May 2019 Resolved
A VISUAL INDICATOR MUST BE PROVIDED AT THE OPERATING STATION TO INDICATE WHEN ANY AUTOMATIC BILGE PUMP IS OPERATING. THE TWO AUTOMATIC BILGE PUMPS ONBOARD THE VESSEL DID NOT HAVE A VISUAL INDICATOR AT THE OPERATING STATION. INSTALL A VISUAL INDICATOR AT THE OPERATING STATION TO INDICATE WHEN AN AUTOMATIC BILGE PUMP IS ACTIVATED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Visaul alarms provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019 Resolved
CHILD SIZE LIFE JACKETS EQUAL TO AT LEAST 10% OF THE NUMBERS OF PERSONS PERMITTED ON BOARD MUST PROVIDED. VESSEL IS PERMITTED 42 PERSONS. PROVIDE 01 ADDITIONAL CHILD SIZED LIFE JACKET FOR A TOTAL OF 05 ONBOARD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Additional child lifejacket provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2019 Resolved
AFT BRACING BAR FOR STARBOARD SIDE HAMMOCK WAS FOUND TO BE IN AN UNSAFE CONDITION. BRACING BAR IS LOOSE. RESECURE THE AFT BRACING BAR FOR STARBOARD HAMMOCK.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Reinforced bracing bar for stbd hammock.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2019 Resolved
VESSEL MUST HAVE NAVIGATION LIGHTS THAT ARE IN COMPLIANCE WITH THE APPLICABLE SECTIONS OF INTERNATIONAL AND INLAND NAVIGATION RULES. VESSEL'S NAVIGATION LIGHTS WERE HAZED REDENURING THEM NOT VISABLE IAW NAVIGATION RULES. REMOVE HAZE FROM NAVIGATION LIGHTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Navigational lights were made visible.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2019 Resolved
BATTERY CONNECTIONS MUST BE AMDE TO BATTERY TERMINALS WITH PERMANENT TYPE CONNECTORS. REPLACE WINGNUT CONNECTORS WITH PERMANENT HEXNUT TYPE CONNECTORS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 5 June 2019
Resolution: Replaced with permanent hex nut.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 May 2018 Resolved
07109: A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Currently, fire-boy systems are interconnected so when one fire-boy is discharged, all engines are shut down. 46 CFR 181.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 11 June 2018
Resolution: Fire-boy systems were rewired independently of each other, so one pre-engineered fixed gas fire extinguishing systems shut down engine in one space.
Lifesaving › Hand Flares › Not on Board
Issued 8 May 2018 Resolved
11116: A vessel on a limited coastwise route must carry 6 hand red flares and 6 hand orange smoke distress signals. Vessel is missing one hand red flare. 46 CFR 180.68(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 21 May 2018
Resolution: Received picture of 6 red hand flares and 6 orange smoke distress signals onboard vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2018 Resolved
10111: Vessel must carry adequate and up-to-date chart, U.S. Coast Pilot, and CG Light List. Vessel does not have an up-to-date chart, CG light list, and Coast Pilot on board. 46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 21 May 2018
Resolution: Received picture of up-to-date chart, Coast Pilot, and CG light List onboard vessel.
Engineering › Bilge Water Management System › Interface Detector
Issued 8 May 2018 Resolved
13104: A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. A visual indicator is not provided for both bilge pumps on board. 46 CFR 182.530(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 11 June 2018
Resolution: A visual indicator was provided for both bilge pumps on board.
Engineering › Bilge Water Management System › Interface Detector
Issued 8 May 2018 Resolved
04113: A visual and audible alarm must be provided at the operating station to indicate a high water level. Port side high water alarm visual indicator is inoperable. 46 CFR 182.530(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2018
Resolved 11 June 2018
Resolution: Port side high water alarm visual indicator was operable.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2018 Resolved
05199: A durable placard must be posted next to all radio telephone installations with the emergency broadcast instructions and information specific to the vessel. Vessel does not have an emergency broadcast placard next to VHF radio onboard. 46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 21 May 2018
Resolution: Received picture of emergency broadcast placard onboard vessel.
Operations/Management › Vessel Activity › Cleaning/Stripping
Issued 3 November 2017 Resolved
Remove sea valves for CG Inspection
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 6 November 2017
Resolution: Sea valves were removed for CG inspection; satsifactory.
Operations/Management › Vessel Activity › Construction/Repair
Issued 3 November 2017 Resolved
Rebed starboard strut support.
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 14 November 2017
Resolution: Starboard strut support was rebedded.
Operations/Management › Vessel Activity › Construction/Repair
Issued 3 November 2017 Resolved
Reweld starboard rudder support.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 14 November 2017
Resolution: Starboard rudder support was rewelded; satisfactory.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 3 November 2017 Resolved
Replace cutlass bearings.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 14 November 2017
Resolution: Cutlass bearings were replaced.
Operations/Management › Vessel Activity › Construction/Repair
Issued 3 November 2017 Resolved
Scrape angel hair to good wood and provide repair plan for angel hair outboard of port side fuel tank.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 8 November 2017
Resolution: Approved repair proposal: Scrape angel hair down to good wood, sand, and fill with 404 high-density filler with 105 epoxy resin and smooth out area and paint.
Operations/Management › Vessel Activity › Construction/Repair
Issued 3 November 2017 Resolved
Scrape out rotted wood in tween deck and provide repair plan for rotted wood in port fuel tank space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 8 November 2017
Resolution: Approved repair plan: Scrape out rotten wood; fill with 404 high-dens. filler with 105 west system. Sand and lay up 18 Oz fiberglass cover with 105 resin, sand, and paint.
Operations/Management › Vessel Activity › Construction/Repair
Issued 3 November 2017 Resolved
Provide repair plan for rotted frame under stbd shaft.
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 8 November 2017
Resolution: Approved repair plan: Scrape away rotten wood on frame, sand down to good wood, apply 404 high-dens. filler, sand, and lay up 18 Oz fiberglass sand and paint.
Operations/Management › Vessel Activity › Underway
Issued 3 November 2017 Resolved
Conduct underway sea trial in presence of CG MI prior to credit dry dock.
Action required: 705 - Other - as specified
Due 3 December 2017
Resolved 20 November 2017
Resolution: Post dry dock sea trial conducted; satisfactory.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 May 2017 Resolved
Prove proper installation of the fixed extinguishing system ventilation shutdown and manual pull cable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Resolution: Verified proper installation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 May 2017 Resolved
Install proper deck rails in all passenger areas.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 10 June 2017
Resolution: Temporary courses installed, pax restricted from other areas. See special note.
Engineering › Fuel Oil Service System › Piping
Issued 11 May 2017 Resolved
Install proper flexible fuel line hose iaw 46 cfr 182.20-40.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 10 June 2017
Resolution: Proper hose installed iaw MSC policy note E1-15.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 May 2017 Resolved
Properly cover lighting fixture in stbd fwd compartment.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 9 June 2017
Resolution: Proper cover provided.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 11 May 2017 Resolved
Properly install dripless packing cooling hose iaw manufacturer inst.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 10 June 2017
Resolution: Hose properly vented.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 May 2017 Resolved
Repair or replace leaking exhaust elbow on port engine.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 9 June 2017
Resolution: Epoxy repair patch installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 May 2017 Resolved
Properly secure wire splices in junction boxes.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 9 June 2017
Resolution: Wire splices put in enclosed boxes.
Construction/Loadline › Penetrations › Gasket
Issued 11 May 2017 Resolved
Make all deck hatches watertight.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 9 June 2017
Resolution: All hatches provided with proper gaskets and closures.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 May 2017 Resolved
Prov e proper operation of stern light.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 9 June 2017
Resolution: Proper operation witnessed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 May 2016 Resolved
Replace retroreflective tape on identified (5) adult life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 13 May 2016
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2016 Resolved
Replace chart onboard with updated chart and provide tide tables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 13 May 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 May 2016 Resolved
Repair visual alarm for starboard void. Bilge alarm was faint/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 13 May 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 May 2014 Resolved
Provide pre-employment chemical testing documentation to the U.S. Coast Guard for any new masters of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2014
Resolution: Received copy of valid masters license, drug test, and proof of enrollment in company''s drug program for new master.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2014 Resolved
Remove old masthead light wire.
Due 21 May 2014
Resolved 18 May 2014
Resolution: emailed picture showing wire had been removed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 May 2014 Resolved
Provide bracket for fire extinguisher.
Due 21 May 2014
Resolved 18 May 2014
Resolution: emailed picture of new fire extinguisher bracket installed
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 May 2014 Resolved
Provide copy of Rules of the Road.
Due 21 May 2014
Resolved 18 May 2014
Resolution: emailed picture showing a copy of the Rules of the Road on board the vessel
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 May 2014 Resolved
Provide current and corrected charts.
Due 21 May 2014
Resolved 18 May 2014
Resolution: emailed a picture showing current charts aboard the vessel
Documentation › Logs/Records › Logbook (official)
Issued 23 August 2011 Resolved
emergency drills not being logged
Action required: 705 - Other - as specified
Due 23 September 2011
Resolved 21 September 2011
Lifesaving › Hand Flares › Expired
Issued 23 August 2011 Resolved
missing one flare
Due 23 September 2011
Resolved 21 September 2011
Navigation › Piloting/Steering › Marine Charts
Issued 23 August 2011 Resolved
Provide current navigational charts
Due 23 September 2011
Resolved 21 September 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 May 2009 Resolved
No evidence that fixed sys had been tested/operated at last servicing by contractor. Prove proper engine shutdown upon sys discharge (w/out discharge), activation.
Due 1 June 2009
Resolved 3 June 2009
Resolution: Owner demonstrated proper operation of engine shutdown and override function.
Stability › Unintentional Flooding › General
Issued 13 May 2009 Resolved
Found that frame members in way of bilges, in the port head & engine spaces and in the stbd fuel tank and engine spaces, prevented any possible water ingress from reaching the high water alarms or bilge pumps. Make all subdivided water tight spaces drain to a common location (bilge high water alarms) for all frames higher than 4".
Due 1 June 2009
Resolved 3 June 2009
Resolution: Owner drilled 1/2" dia holes in aft eng frames and middle two frames in head space and engine tank space to allow water to drain to high water bilge alarms.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2009 Resolved
Found ring buoy grab lines to be deteriorated. Renew lines or replace ring buoy.
Due 22 May 2009
Resolved 13 May 2009
Resolution: New ring buoy installed.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 20 April 2009 Resolved
Found no indication of ring buoy water light battery being renewed in the past 12 mos. Renew same.
Due 22 May 2009
Resolved 13 May 2009
Resolution: New battery installed with date marked on battery.
Construction/Loadline › Hull › Stiffener
Issued 20 April 2009 Resolved
Found numerous areas of rotted wood (angel hair) throughout vsl. Sand to good wood and protect.
Due 22 May 2009
Resolved 3 June 2009
Resolution: Completed majority of work and will continue to do same until completed and by end of drydock in Oct 2009.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 20 April 2009 Resolved
Found pinched/damaged (caught between deck plate and frame) ground wire attached to through hull fitting in bilge space below port head. Repair same.
Due 22 May 2009
Resolved 13 May 2009
Resolution: Wire repaired and small hole cut in edge of deck plate to accomodate wire run.
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 April 2009 Resolved
Found numerous openings in engine compartments that contain fixed-fire fighting equipment. Make both engine compartments vapor tight.
Due 6 May 2009
Resolved 3 June 2009
Resolution: Owner plug all holes and installed gasket material around both drive shafts.
Engineering › Steering Gear System › Bracket/Clamp
Issued 20 April 2009 Resolved
Found steering gear mounting bracket/plate loose when steering sys was operated. Resecure steering gear mounting plate to prevent movement.
Due 22 May 2009
Resolved 13 May 2009
Resolution: Metal angle plate & new hardware installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2009 Resolved
Found canopy obstructing all-around white light arc of visibility. Extend all-around light to a height as to be seen at a distance of 2 miles.
Due 22 May 2009
Resolved 13 May 2009
Resolution: Light extended to height of 6''.
Construction/Loadline › Hull › Side Shell
Issued 20 April 2009 Resolved
Found aft stbd port light frame cracked. Make port light watertight.
Due 22 May 2009
Resolved 13 May 2009
Resolution: New port light installed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 April 2009 Resolved
Found Coast Pilot and Light List outdated. Update same to reflect current changes.
Due 22 May 2009
Resolved 13 May 2009
Resolution: Updates provided.
Construction/Loadline › Structures › Deck Plating
Issued 20 April 2009 Resolved
Found all watertight hatch seals wasted or deteriorated. Make all watertight hatches, watertight.
Due 22 May 2009
Resolved 13 May 2009
Resolution: New seals installed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 April 2009 Resolved
Found unused overboard discharge fitting uncapped in stbd fuel tank space. Make same watertight.
Due 22 May 2009
Resolved 13 May 2009
Resolution: Permanent cap installed.
Engineering › Bilge Water Management System › Pump
Issued 20 April 2009 Resolved
hand bilge pump was missing hose. Make hand bilge pump operable for deepest bilge to main deck for overboard discharge.
Due 22 May 2009
Resolved 13 May 2009
Resolution: New, flexible hose installed on pump.
Engineering › Lubricating Oil Service System › Hose
Issued 20 March 2007 Resolved
Fuel hoses on both propulsion engines have dry-rot/cracking on outer covering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 29 March 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 20 March 2007 Resolved
Fuel tank in stbd hull has a fuel line of improper material installed leading to the Accomodation space where it is improperly capped. Remove hose and cap fitting at tank connection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 29 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 20 March 2007 Resolved
Stbd engine has loose mounting bolts in connection from bedplate to hull frame.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 29 March 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 20 March 2007 Resolved
Fill hose for stbd tank is soft and of improper material. Replace fill hose from deck to tank with material of proper grade
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 29 March 2007
Construction/Loadline › Structures › Superstructure
Issued 20 March 2007 Resolved
Owner must provide a rigging survey. Visual inspection revealed main mast step movement while under sail. Main boom gooseneck wear from stop bolt. Furling line parting/wear at roller furling for jib.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 29 March 2007
Construction/Loadline › Structures › Deck Plating
Issued 3 November 2005 Resolved
Replace/reglass rotted areas around deck hatches as noted.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 14 November 2005
Resolution: Corrected.
Engineering › Steering Gear System › Rudder
Issued 3 November 2005 Resolved
Re-attach/fasten and repair STBD rudder support assy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 14 November 2005
Resolution: Corrected.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 3 November 2005 Resolved
Replace worn strutt bearings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 14 November 2005
Resolution: Corrected.
Engineering › Sea-water System (primary cooling) › Valve
Issued 3 November 2005 Resolved
Replace through hole fittings and spool pieces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 14 November 2005
Resolution: Correcetd.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2005 Resolved
Make repair to inop stern light.
Due 15 April 2005
Resolved 2 April 2005
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 1 April 2005 Resolved
Provide evidence CPR course.
Due 15 April 2005
Resolved 4 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 April 2005 Resolved
Provide aspirin and eye wash for first aid kit.
Due 15 April 2005
Resolved 4 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 April 2005 Resolved
Provide machinery guard for port engine.
Due 15 April 2005
Resolved 12 April 2005
Communications › Radio Communications › EPIRB
Issued 1 April 2005 Resolved
Provide new antennae for EPIRB
Due 15 April 2005
Resolved 4 April 2005
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 1 April 2005 Resolved
Provide Marine Radio Operators Permit for all licensed masters.
Due 15 April 2005
Resolved 4 April 2005
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2002 Resolved
Provide repair proposal for port aft outboard hull area, i.e. 28"' X 31".
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2002
Resolved 4 February 2002
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2002 Resolved
Provide repair proposal for port fwd area on the inboard and outboard sides of hull.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2002
Resolved 4 February 2002
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2002 Resolved
Provide repair proposal for the stbd aft inboard hull.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2002
Resolved 4 February 2002
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2002 Resolved
Provide repair proposal for port interior hull termite damage and provide proposal to remove termites from the vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2002
Resolved 4 February 2002
Documentation
Issued 17 March 2000 Resolved
Found FCC Safety Radiotelephone certificate expired. Requied vsl to obtaina new one IAW 47 CFR 80.903.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Fire Fighting
Issued 17 March 2000 Resolved
Found fixed fire fighting system not installed IAW 46 CFR 181.420. Required vsl to install an automatic engine shutdown or install piping for engine to take air from outside the space being protected by the fixed firefighting system.
Condition: Unknown
Due 17 March 2000
Resolved 17 March 2000
Navigation
Issued 24 December 1999 Resolved
Replace STBD running light, 46 CFR 183.420.
Condition: Unknown
Due 24 December 1999
Resolved 24 December 1999
Construction/Loadline
Issued 24 December 1999 Resolved
Prove proper operation of high water alarm in port and stbd engine compartments, 46 CFR 182.530.
Condition: Unknown
Due 24 December 1999
Resolved 24 December 1999
Documentation
Issued 24 December 1999 Resolved
Obtain FCC radiotelephone safety certificate, IAW 47 CFR 80.903.
Condition: Unknown
Due 24 December 1999
Resolved 24 December 1999
Fire Fighting
Issued 24 December 1999 Resolved
Prove proper operation of fixed fire fighting system, 46 CFR 181.420.
Condition: Unknown
Due 24 December 1999
Resolved 24 December 1999
Navigation
Issued 22 May 1998 Resolved
Provide cotter pins for all linkages of steering system.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Engineering
Issued 22 May 1998 Resolved
Mount heat deflectors under port and stbd fuel filters.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Lifesaving
Issued 22 May 1998 Resolved
Mount EPIRB in float free arrangement and register with NOAA.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Lifesaving
Issued 22 May 1998 Resolved
Remark ring buoy with vessel name and properly mount its life light.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Documentation
Issued 15 May 1996 Resolved
Provide documentation of crew training in accordance with IFR 46 CFR 185.420.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996 Resolved
Provide documentation of abandon ship and man overboard drills and trainingin accordance with IFR 46 CFR 185.520.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Fire Fighting
Issued 15 May 1996 Resolved
Provide documentation of fire fighting drills and training in accordance with IFR 46 CFR 185.524.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996 Resolved
Provide documentation of weekly maintenance and inspection for survival craft in accordance with IFR 46 CFR 185.720.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996 Resolved
Provide documentation of passenger count in accordance with IFR 46 CFR 185.504.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Deck/Cargo
Issued 3 July 1995 Resolved
Renew in kind, wasted anchor line fitting at anchor chain connection.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Fire Fighting
Issued 3 July 1995 Resolved
Provide watertight or vapor tight separation between the accommodation areaand the port main diesel engine, stbd main diesel engine, and the stbd fueltank in accordance with 46 CFR 182.35.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Engineering
Issued 3 July 1995 Resolved
Provide and install approved flexible hose with fittings for the fuel supply and return of each main diesel engine.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Engineering
Issued 19 May 1995 Resolved
PROVIDE PROPER GROUNDING MEANS FOR FLEXIBLE FILL PIPE SECTION, PORT FUEL TANK FILL PIPE.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Electrical
Issued 19 May 1995 Resolved
PROVIDE/RENEW COMMON GROUNDING MEANS FOR ALL METALLIC THROUGH HULL FITTINGS, MACHINERY AND ASSOCIATED SYSTEMS.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Engineering
Issued 17 June 1993 Resolved
PROPERLY GROUND THE PORT SIDE FORWARD FUEL TANK.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 20 May 1992 Resolved
INSTALL AN ACCEPTABLE METAL FUEL FILTER OR INSTALL A FLAME CUP ON STARBOARD ENGINE FUEL FILTER.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Electrical
Issued 20 May 1992 Resolved
PROVIDE A FUSE CLOSE TO BATTERY WHICH SUPPLIES POWER TO THE MAIN SWITCHBOARD.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Unknown
Issued 31 May 1991 Resolved
PROVIDE A FIXED HAND BILGE PUMP OR A POWER BILGE PUMP IN THE PORT FORWARD COMPARTMENT.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
PROVIDE A FIXED HAND BILGE PUMP OR A POWER BILGE PUMP IN THE STARBOARD FORWARD COMPARTMENT.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
INSTALL A FIXED HAND BILGE PUMP OR A POWER BILGE PUMP IN THE STARBOARD FORWARD MAIN ENGINE COMPARTMENT.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
PROVIDE A THROUGH HULL FITTING FOR THE FIXED HAND BILGE PUMP IN THE MARINE SANITATION DEVICE COMPARTMENT.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
PROPERLY MARK THE 8 PERSON BUOYANT APPARATUS WITH THE VESSEL'S NAME AND THECAPACITY OF THE APPARATUS.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
PROPERLY ROUTE THE ELECTRIC BILGE PUMP WIRES THROUGH A FUSED SWITCH OR A CIRCUT BREAKER.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
INSTALL COPPER FUEL LINE .035" MINIMUM WALL THICKNESS FROM THE FUEL TANK TOTHE MAIN ENGINES. FLEXIBLE FUEL LINE OR USCG TYPE A1 FUEL HOSE MAY BE USEDIN 30 INCH RUNS OR LESS.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
INSTALL PVC OR FLEXIBLE PVC ON THE ELECTRIC BILGE PUMP DISCHARGE LINES.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
INSTALL A REVOTE FUEL SHUTDOWN ON THE PORT AND STARBOARD FUEL TANK.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Unknown
Issued 31 May 1991 Resolved
PROPERLY POST THE VESSEL'S CERTIFICATE OF INSPECTION, STABILITY LETTER AND EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 31 May 1991
Resolved 31 May 1991
Documentation
Issued 6 June 1989 Resolved
PLACE ON BOARD THE ORIGINAL STABILITY LETTER AND CERTIFICATE OF INSPECTION
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989 Resolved
PROVIDE ONBOARD, 6 ADDITIONAL RED SIGNAL FLARES AND 6 ORANGE SMOKE FLARES WITH CURRENT SERVICE DATES.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 1 June 1988 Resolved
PROVIDE 3 RED AND 3 ORANGE HAND HELD DISTRESS SIGNALS TO BRING VESSEL STORES TO A LEVEL OF 6 RED AND 6 ORANGE SIGNALS.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Documentation
Issued 1 June 1988 Resolved
PROVIDE COPY OF AND PLACE ON BOARD VESSEL, CURRENT FCC FORM 824, SAFETY RADIOTELEPHONY CERTIFICATE. UNTIL THIS REQUIREMENT IS MET, THIS VESSEL IS RESTRICTED TO OPERATION NOT MORE THAN 1000 FEET FROM SHORE.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Unknown
Issued 8 June 1987 Resolved
REPAIR OR REPLACE THE TWO OPENING PORT LIGHTS ON THE OUTBOARD SIDE OF THE PORT HULL.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Unknown
Issued 8 June 1987 Resolved
PROVIDE AND INSTALL A FLAME SHIELD DEFLECTOR ON THE FUEL OIL FILTER FOR THE PORT ENGINE.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Unknown
Issued 8 June 1987 Resolved
REPLACE THE RING BUOY AND PROVIDE WATER LIGHT. UNTIL THIS ITEM IS CORRECTED, NO PASSENGERS MAY BE CARRIED.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Unknown
Issued 8 June 1987 Resolved
CLEAN OR REPLACE THE PORT AND STARBOARD RUNNING LIGHT LENSES AND REPAIR THESTERN LIGHT. UNTIL THIS ITEM IS CORRECTED, THE VESSEL IS LIMITED TO DAYLIGHT OPERATION.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Unknown
Issued 8 June 1987 Resolved
INSTALL FLAME SCREENS ON THE VENTS FOR BOTH FUEL TANKS. UNTIL THIS ITEM ISCOMPLETED, NO PASSENGERS MAY BE CARRIED.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Fire Fighting
Issued 7 June 1985 Resolved
PROVIDE 1 B-II TYPE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Construction/Loadline
Issued 7 June 1985 Resolved
INSTALL A PERMANENT 6 INCH COAMING INTO CABIN ACCESS.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Electrical
Issued 7 June 1985 Resolved
PROVIDE AUTOMATIC EMERGENCY LIGHTING FOR CABIN.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Unknown
Issued 7 June 1985 Resolved
REMOVE ALL PAINT FROM VESSEL.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985
Unknown
Issued 7 June 1985 Resolved
PROVE OPERATION OF LORAN AND AUTO PILOT.
Condition: Unknown
Due 7 June 1985
Resolved 7 June 1985

Casualty record · 6

24 July 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1833480
26 June 2003Routine · role: Subject to Marine Inspection · 1 injured · activity 1903072
31 January 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1999263
1 March 2004Routine · role: Involved in a Marine Casualty · activity 2018400
20 December 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4518708
4 July 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6482926
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.