Records from 1983 to 2004. Most recent: inspection, 10 September 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
10 September 2004
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2192661
25 September 2002
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1679865
23 August 2001
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 214859
23 August 2001
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1462985
12 October 2000
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1410419
21 September 1999
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1340845
24 August 1999
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1455753
26 August 1998
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1386327
9 June 1998
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1413388
18 May 1998
Drydock Extension
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 791348
3 September 1997
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1394822
18 September 1996
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1451097
7 September 1995
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1452070
22 September 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1171447
8 November 1993
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1158973
7 October 1993
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1139533
7 October 1992
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1357965
11 September 1992
COI Inspection · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1268469
20 February 1992
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 956706
9 October 1991
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1389534
2 August 1991
Re-Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1249713
5 April 1991
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1234713
23 July 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 929980
1 December 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1212438
2 August 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1197355
7 December 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1209264
28 November 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1207735
24 August 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1039453
8 July 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 900545
13 April 1988
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1339315
9 February 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1327098
13 January 1988
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1011033
9 December 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1002841
24 November 1987
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1026111
3 November 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1329617
6 March 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1009273
29 January 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1011073
21 January 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1011441
14 January 1987
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1313440
27 April 1986
Credit Drydock
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1296812
29 November 1985
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1295988
6 December 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 977067
23 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281050
9 May 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273231
26 January 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 967535
Electrical › Electrical Distribution System (service)
Issued 25 September 2002
Resolved
Most engine room wiring/cabling, secured to overhead w/wireties. Install metal hangers every 24" IAW 46CFR183.340(a)(4). LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 25 October 2002
Resolved 25 October 2002
Resolution: Wiring secured, as required.
Lifesaving › Lifejacket/PFD (Type I)
Issued 25 September 2002
Resolved
Total lifejacket onboard 149 adults, 23 children. Passenger Count reduced to 146, until provide three additional adult Type I PFD's. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2002
Resolution: Passenger count remains 146.
Operations/Management › Drug and Alcohol Testing
Issued 25 September 2002
Resolved
No proof of consortium contract, and CY 2001/2002 MIS Report. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 25 October 2002
Resolution: Operator meets substantial compliance.
Electrical › Electrical Distribution System (service)
Issued 25 September 2002
Resolved
Remove all portable cable from permanent equipment. Hard wire air compressor. Renew stern lt cable w/CG approved cable and/or provide proof of approval of installed wire. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 25 October 2002
Resolution: Operator is in the process moving the vessel from its current operational area, to the Mobile, AL area. This process will require the partial disassembly of the vessel. Upon re-assembly of the vessel the systems effected will be re-wired. NLT 1FEB03.
Electrical
Issued 12 October 2000
Resolved
Place and secure covers on all battery boxes.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Electrical
Issued 12 October 2000
Resolved
Replace insulation on generator exhaust.
Condition: Unknown
Due 9 November 2000
Resolved 18 October 2000
Construction/Loadline
Issued 12 October 2000
Resolved
Prepare to test bilge pump from all strainor locations.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Navigation
Issued 12 October 2000
Resolved
Repair port steering ram on monkey rudder system.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Engineering
Issued 12 October 2000
Resolved
Replace all oil absorbant pads under main engines and generator.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Construction/Loadline
Issued 12 October 2000
Resolved
Remove all oil from bilges and maintain bilges in a clean condition.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Documentation
Issued 12 October 2000
Resolved
Maintain monthly training log to include fire, man overboard and abandon ship drills.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Lifesaving
Issued 12 October 2000
Resolved
Provide current day/night visual distress signals.
Condition: Unknown
Due 9 November 2000
Resolved 13 November 2000
Construction/Loadline
Issued 12 October 2000
Resolved
Identify and correct source of water leak into #4 void space.
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Lifesaving
Issued 24 August 1999
Resolved
Post a sign in the area of the ladder to the second deck with "maximum number of passengers allowed on second deck" according to stability letter.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Construction/Loadline
Issued 24 August 1999
Resolved
Install bilge high level alarm that alarms audible and visual at the operating station in every space with a through hull fitting below the water line.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Navigation
Issued 24 August 1999
Resolved
Reinstall both port and starboard running lights and prove proper operation. Until such time as running lights are operating properly the vessel shall restrict operations to day time only.
Condition: Unknown
Due 15 October 1999
Resolved 15 October 1999
Accommodation/Occupational Safety
Issued 7 October 1993
Resolved
REPAIR LEAKING POTABLE WATER PIPE IN #6 COMPARTMENT.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Lifesaving
Issued 7 October 1993
Resolved
MAXIMUM NUMBER OF ADULT PASSENGERS ALLOWED ON BOARD IS 146 UNTIL 3 ADDITIONAL ADULT PFD ARE PLACED ON BOARD.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Documentation
Issued 7 October 1993
Resolved
PROVIDE EVIDENCE OF CURRENT VESSEL DOCUMENTATION.
Condition: Unknown
Due 7 October 1993
Resolved 7 October 1993
Lifesaving
Issued 11 September 1992
Resolved
MAXIMUM ADULT PASSENGERS ON BOARD LIMITED TO 148 UNTIL 1 ADDITIONAL LIFE PRESERVER IS PLACED ON BOARD TO THE SATISFACTION OF THE COGNIZANT [name withheld] NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Electrical
Issued 11 September 1992
Resolved
PROPERLY SUPPORT WIRING TO PILOT HOUSE AND INSTALL CHAFFING GEAR IN PILOT HOUSE DECK PENETRATION FOR WIRE RUNS TO THE SATISFACTION OF THE COGNIZANT [name withheld] NOT LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Navigation
Issued 11 September 1992
Resolved
REPAIR STERN LIGHT FIXTURE TO SATISFACTION OF COGNIZANT [name withheld] NOT LATER THAN THE COMPLIANCE DATE. VESSEL MAY NOT OPERATE AT NIGHT OR DURING REDUCEDVISIBILTY CONDITIONS UNTIL STERN LIGHT IS REPAIRED.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Engineering
Issued 2 August 1991
Resolved
REPAIR PORT MAIN ENGINE REMOTE FUEL SHUT OFF VALVE SO AS TO POSITIVELY STOPIN THE OPEN OR CLOSED POSITIONS.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Lifesaving
Issued 2 August 1991
Resolved
MAXIMUM NUMBER OF PASSENGERS REDUCED TO 122, MAX TOTAL PERSONS 130, UNTIL ADEQUATE NUMBER OF CHILD SIZE LIFE PRESERVERS ARE ON BOARD.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Engineering
Issued 2 August 1991
Resolved
REMOVE AIR RECEIVER IN ENGINE ROOM OR PROVIDE EVIDENCE THAT IT IS DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ASME CODE SECTION VIII DIVISION 1, IN ACCORDANCE WITH 46 CFR 54.01-5.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Construction/Loadline
Issued 2 August 1991
Resolved
MAKE PERMANENT REPAIR TO HATCH COVER FRAMING FOR DECK ACCESS COVERS #5 AND #6 COMPARTMENTS.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Electrical
Issued 2 August 1991
Resolved
REMOVE 3 WIRES IN CONDUIT DEAD ENDING IN THE AIR CONDITIONER ROOM OR PROPERLY TERMINATE.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Engineering
Issued 2 August 1991
Resolved
MARK EMERGENCY FUEL SHUT OFF VALVES ON DECK SO AS TO MAKE THEM READILY VISIBLE, IN ADDITION TO THE EXISTING LABELS ON THE BULKHEAD.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Lifesaving
Issued 2 August 1991
Resolved
REPLACE OUTDATED ORANGE SMOKE AND RED FLARES.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Documentation
Issued 2 August 1991
Resolved
PROVIDE EVIDENCE OF APPLICATION FOR FCC STATION LICENSE.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Lifesaving
Issued 2 August 1991
Resolved
LABEL ALL LIFE PRESERVERS AND RING BUOYS WITH CORRECT VESSEL NAME.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Documentation
Issued 2 August 1991
Resolved
POST OIL POLLUTION AND GARBAGE POLLUTION PLACARDS ON BOARD THE VESSEL.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Accommodation/Occupational Safety
Issued 23 July 1990
Resolved
PROPERLY SECURE ALL CO2 CYLINDERS FOR BAR SERVICE.
Condition: Unknown
Due 23 July 1990
Resolved 23 July 1990
Fire Fighting
Issued 23 July 1990
Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 23 July 1990
Resolved 23 July 1990
Fire Fighting
Issued 23 July 1990
Resolved
PROVIDE B-I FIRE EXTINGUISHER FOR PILOT HOUSE.
Condition: Unknown
Due 23 July 1990
Resolved 23 July 1990
Electrical
Issued 23 July 1990
Resolved
PROPERLY SECURE GENERATOR WIRING IN PILOT HOUSE.
Condition: Unknown
Due 23 July 1990
Resolved 23 July 1990
Fire Fighting
Issued 23 July 1990
Resolved
PROVIDE EVIDENCE OF UL APPROVAL OF 1 1/2" FIRE HOSE, OR REPLACE WITH 5/8" GARDEN HOSE AND APPROPRIATE NOZZLE.
Condition: Unknown
Due 23 July 1990
Resolved 23 July 1990
Unknown
Issued 2 August 1989
Resolved
PROVIDE LABELING FOR THE BILGE PIPING SYSTEM.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Unknown
Issued 2 August 1989
Resolved
PROVIDE ONE(1) INCH LABELS FOR THE LIFE PRESERVER STOWAGE ON THE UPPER DECK
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Unknown
Issued 2 August 1989
Resolved
PROVIDE ONE(1) INCH LABELS FOR ALL EMERGENCY EXITS. TO READ "EMERGENCY EXIT, KEEP CLEAR".
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Unknown
Issued 2 August 1989
Resolved
PROVIDE ONE(1) INCH LABELS FOR THE REMOTE FUEL SHUTOFF STATION.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Engineering
Issued 2 August 1989
Resolved
PROVIDE AND INSTALL EXHAUST VENTILATION DUCTING FOR THE ENGINE ROOM WITH EXTENDS TO THE BILGE AND IS MADE OF FIRE PROOF MATERIAL.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Navigation
Issued 2 August 1989
Resolved
PROVIDE AND INSTALL ANCHOR LIGHT.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Construction/Loadline
Issued 2 August 1989
Resolved
PROVIDE A SECURING DEVICE AND A CHAIN OR OTHER DEVICE TO PREVENT THE LOSS OF THE FORWARD HATCH.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Electrical
Issued 2 August 1989
Resolved
PROVIDE A COVER FOR ALL THE BATTERIES.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Lifesaving
Issued 28 November 1988
Resolved
PROVIDE TWO ADDL. ADULT AND TWO ADDL. CHILD TYPE I PRDO AN BOARD THE VESSELNO LATER THAN 08DEC88. TOTAL PRESON LIMITED TO 156 & 14 CHILDERN.
Condition: Unknown
Due 28 November 1988
Resolved 28 November 1988
Documentation
Issued 8 July 1988
Resolved
IN ACCORDANCE WITH 47 USC 381 AND 46 CFR 184.25-1, THE VESSEL MUST BE PROVIDED WITH A VALID FCC SAFETY RADIOTELEPHONE CERTIFICATE AND ITS OPERATOR(S) WITH VALID FCC MARINE OPERATOR'S PERMIT(S), ISSUED BY THE FCC, AND NO LATER THAN 22 AUGUST 1988.
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Engineering
Issued 9 February 1988
Resolved
THE DIESEL PROPULSION & GENERATOR EXHAUST SYSTEMS MUST BE RELOCATED TO ABOVE THE DEEPEST LOAD WATERLINE & BE REPLACED WITH CORROSION RESISTANT MATERIAL, IAW 46CFR182.15-15&20, AT THE NEXT SCHEDULED HAUL-OUT, NLT 30APR88.
Condition: Unknown
Due 9 February 1988
Resolved 9 February 1988
Navigation
Issued 24 November 1987
Resolved
MAKE PERMANT REPAIRS TO THE STEERING UNIT RAMS TO PREVENT LEAKAGE OF HYD- RAULIC FLUID NLT 10DEC87.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987
Resolved
PROVIDE TEN (10) ADDITIONAL ADULT PFD'S ANBOARD THE VESSEL (148 ONBOARD, 158 REQD.) NLT 10DEC87. TOTAL PERSONS ALLOWED ON BOARD IS LIMITED TO 148 UNTIL REQUIRED AMOUNT IS PROVIDED.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987
Resolved
REPAIR OR REPLACE THE INOPERATIVE RING BUOY WATER LIGHT NLT 02DEC87.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Unknown
Issued 14 January 1987
Resolved
CLEAN DEBRIS FROM ENGINE COMPARTMENT BILGE
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Electrical
Issued 14 January 1987
Resolved
REPLACE MISSING COVERS FROM GENERATOR IN ENGINE COMPARTMENT.
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Electrical
Issued 14 January 1987
Resolved
REWIRE POWER SUPPLY FOR STEREO SYSTEM IN UPPER GALLEY WITH APPROVED MATERIALS.(46CFR183.05-45)
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Lifesaving
Issued 14 January 1987
Resolved
PROVIDE 5 ADDITIONAL ADULT AND 4 CHIL TYPE I LIFE PRESEVERS NLT 15FEB87. THE MAXIMUM NUMBER PASSENGERS LIMITED TO 145 ADULT & 12 CHILDREN UNTIL CORRECTED.
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Electrical
Issued 14 January 1987
Resolved
INSTALL BLANKS IN POWER PANELS IN STORE ROOM WHERE BREAKERS NOT INSTALLED.
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Electrical
Issued 14 January 1987
Resolved
REMOVE UNUSED PORTABLE TYPE ELECTRICAL WIRING FROM STORE ROOM.
Condition: Unknown
Due 14 January 1987
Resolved 14 January 1987
Accommodation/Occupational Safety
Issued 29 November 1985
Resolved
CROP OUT AND RENEW STEPS BETWEEN MAIN DECK AND UPPER DECK.
Condition: Unknown
Due 29 November 1985
Resolved 29 November 1985
Construction/Loadline
Issued 29 November 1985
Resolved
CROP OUT AND RENEW HATCH CHANNEL AND DRAIN AREA PORT SIDE FWD COMPARTMENT
Condition: Unknown
Due 29 November 1985
Resolved 29 November 1985
Electrical
Issued 29 November 1985
Resolved
REPAIR ELECTRICAL PANELBOARD TO FILL IN BLANKS
Condition: Unknown
Due 29 November 1985
Resolved 29 November 1985
Construction/Loadline
Issued 29 November 1985
Resolved
CROP OUT AND RENEW UPPER DECK PORT SIDE FWD FROM DECK HOUSE TO RAIL WERE BADLY PITTED.
Condition: Unknown
Due 29 November 1985
Resolved 29 November 1985