THE MR. RIC is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 13 inspections since 1983, most recently in November 1993, along with 36 deficiencies.

Records from 1983 to 1993. Most recent: inspection, 24 November 1993.

Built
1982
Last inspected
24 November 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-54579

Inspections, by type

…with no type recorded9
Years with a record 6 calendar years (1983–1993)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3005 - Regulatory (Subpart C or D), Gross Ton
3005 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

24 November 1993 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1158478
24 August 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896748
29 April 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334499
15 November 1985 Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1001507
2 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 984463
25 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 982781
17 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 981836
22 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973479
9 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281949
27 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281187
9 March 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970946
31 January 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279100
18 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278850

Deficiency record · 36

Electrical
Issued 17 January 1985 Resolved
MAKE PERMANENT REPAIRS TO AUTOMATIC BUS TRANSFER SWITCH FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985 Resolved
REPAIR OR REPLACE TACHOMETER TO #2 GENERATOR.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Accommodation/Occupational Safety
Issued 17 January 1985 Resolved
INSPECT ALL AIR RECEIVER OR PERFORM HYDROSTATIC TEST ON SAME.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985 Resolved
RPAIR OR REPLACE VOLTMETER TO #1 GENERATOR.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985 Resolved
TEST ALARMS AND OVERSPEED ON #1 GENERATOR.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985 Resolved
REPLACE PISTOL FLARES IN BOTH CAPSULES.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985 Resolved
SUBMIT PROPOSAL TO PROVIDE VENTILATION SHUTDOWN TO EMERGENCY GENERATOR ROOM
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Electrical
Issued 17 January 1985 Resolved
PROVIDE EMERGENCY LIGHTING THROUGHOUT THE RIG IN ACCORDANCE WITH 46 CFR 112.39
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985 Resolved
REPAIR END CAP ON TOP OF PILOT HOUSE TO BACK UP SYSTEM SPARY TUBE ON #1 CAPSULE.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985 Resolved
PROVIDE COVERS FOR EMERGENCY ESCAPE ACCESSES ON PORT AND STARBOARDD SIDES OF RIG.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Accommodation/Occupational Safety
Issued 17 January 1985 Resolved
MAKE HELO DECK SKID PROOF AND REPAINT IN ACCORDANCE WITH CURRENT DIRECTIVES
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985 Resolved
REPLACE JACK KNIFE IN #1 CPSULE.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Construction/Loadline
Issued 17 January 1985 Resolved
MAKE PERMANENT REPAIRS TO SLIDING DOOR VENT COVERS TO PUMP ROOM. THESE REQUIREMENTS ARE TO BE AMDE TO THE SATISFACTION OF THE COGNIZANT OCMI
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Deck/Cargo
Issued 17 January 1985 Resolved
TEST LL RELIEF VALVES ON AIR RECEIVERS.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Deck/Cargo
Issued 17 January 1985 Resolved
INTERNALLY INSPECT ALL BULK CHEMICAL TANKS.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985 Resolved
PROPERLY MARK RELEASE HANDLES ON BOTH CAPSULES.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Lifesaving
Issued 17 January 1985 Resolved
PROVIDE ONE (1) SERVICE LINE AND ONE (1) 500' AUXILIARY LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Fire Fighting
Issued 17 January 1985 Resolved
REPLACE GLASS TUBES AT EMERGENCY FIRE ALARM BOXES 5,6, AND 10.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Navigation
Issued 17 January 1985 Resolved
REPLACE BULB IN NAVIGATIONLIGHT ON PORT SIDE.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Unknown
Issued 9 March 1984 Resolved
PROVIDE LEAD LINING FOR HTE FOG HORN BATTERY BOX.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE [name withheld], DN653663.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE FOR USE BY PERSON IN CHARGE A LOG BOOK AS REQUIRED BY 46 CFR 109.433.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE ON BOARD AN APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
RENEW THE GASKET ON THE MUD STORAGE COMPARTMENT HATCH.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE NOT-UNDER-COMMAND NAVIGATION LIGHTS.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
INSTALL A GENERAL ALARM BELL IN THE SCR AIR CONDITIONING ROOM.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE APPROVED FUEL OIL HOSES AS REQUIRED BY 33 CFR 154.500.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
RESUBMIT FIRE & LIFESAVING PLAN TO MSO, PORT ARTHUR, TX SHOWING FIXED FIRE EXTINGUISHING SYSTEM ON PAINT LKR & CORRECT LOCATION OF FIREMAN'S OUTFITS.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE PLANS TO MSO, PORT ARTHUR, TEXAS SHOWING PERTINENT DATA ON INSTAL- LATION OF PAINT LOCKER.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE AND MAINTAIN CRANE RECORD BOOKS AS REQUIRED BY 46 CFR 109.437.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE WIRING SCHEMATICS FOR ALL MOTOR CONTROLLERS AS REQUIRED BY 46 CFR 111.70-20(Q), 111,05-10(C)(7).
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE A SERVICING CERTIFICATE FOR THE PORTABLE FIRE EXTINGUISHERS MISSINGSERVICING TAGS.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
INSTALL AN ADDITIONAL QUARTERS VENTILATION SHUTDOWN AS REQUIRED BY 46 CFR 111.103 & LABEL THE MAIN CIRCUIT BREAKER AS TO IT'S FUNCTION DURING A FIRE.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
PROVIDE INSULATION FOR THE EMERGENCY GENERATOR MANIFOLD AND EXHAUST.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
REPAIR THE PORT MUD PIT DOOR.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 9 March 1984 Resolved
LABEL THE REMOTE FUEL OIL SHUTDOWN VALVE FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.