Records from 1987 to 2009. Most recent: inspection, 21 July 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
21 July 2009
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3541540
14 October 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3344314
30 July 2008
Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3283881
10 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3130934
25 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3086662
10 October 2006
Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2797736
10 July 2006
Deficiency Check · COI Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2707913
1 December 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180290
24 June 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 655414
19 January 1993
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452926
31 December 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141308
4 June 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930472
31 August 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040173
29 June 1988
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207458
23 February 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1024194
5 October 1987
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1312464
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 October 2008
Resolved
Vessel required 20 Type I PFD's. Only 19 on board. Vessel restricted to 15 passengers until additional PFD is placed on board.
Due 14 November 2008
Resolved 15 October 2008
Resolution: One additional Type I PFD purchased for vessel.
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 14 October 2008
Resolved
Compass had no light for night navigation. Vsl restricted to daylight hours until light is installed.
Due 14 November 2008
Resolved 15 October 2008
Resolution: Compass light repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 14 October 2008
Resolved
Starboard engine shutdown not working. Engine had to be stopped from engine room.
Due 14 November 2008
Resolved 15 October 2008
Resolution: Engine shutdown adjusted to shut down engine from pilot station.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 October 2008
Resolved
Provide junction box for navigation wires in operating station. Wires from navigation lights were twisted together and taped to main wire.
Due 14 November 2008
Resolved 15 October 2008
Resolution: Wiring connected properly through junction box.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 October 2008
Resolved
Only one alcohol test strip on board. Vessel may have up to a four man crew or minimum two man crew.
Due 14 November 2008
Resolved 15 October 2008
Resolution: Additional alcohol test strips purchased.
Lifesaving › Lifefloat › Serviceable
Issued 25 October 2007
Resolved
Service 6 man lifefloat or remove from vessel.
Due 25 November 2007
Resolved 10 December 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 October 2007
Resolved
Place 2 more Type-I PFD's on vessel. Total persons allowed onboard reduced to 18 until corrected.
Action required: 705 - Other - as specified
Resolved 10 December 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 October 2007
Resolved
Install Type III MSD on vessel and supply marine inspector with certification paperwork.
Due 25 November 2007
Resolved 10 December 2007
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 25 October 2007
Resolved
Install voltmeter & ampmeter for generator. Provide one line diagram to marine inspector for installation and provide certification for generator
Due 25 November 2007
Resolved 10 December 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 25 October 2007
Resolved
Renew ball vent on fuel tank and install 30x30 mesh flame screen.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 25 October 2007
Resolved
Remove old lighting fixtures and dead wiring from machinery spaces and old hydraulic lines from under steering stations.
Due 25 November 2007
Resolved 10 December 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 10 July 2006
Resolved
Missing emergency broadcast placard.
Due 30 August 2006
Resolved 16 August 2006
Documentation › Logs/Records › Logbook (official)
Issued 10 July 2006
Resolved
Missing a ships log.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 July 2006
Resolved
Mag compass was not wired into a power source.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 July 2006
Resolved
Missing the masthead light
Action required: 17 - Rectify deficiencies prior to departure
Due 16 August 2006
Resolved 16 August 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 July 2006
Resolved
Stern light was extinguished.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2006
Navigation › Piloting/Steering › Marine Charts
Issued 10 July 2006
Resolved
No marine charts were onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 10 July 2006
Resolved
Remote shutdown was not operational from the pilot house.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2006
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 July 2006
Resolved
Alcohol testing kit was not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 August 2006
Resolved 16 August 2006