← All vessels
GRATITUDE
Passenger (Inspected) · Passenger Ship class · Built 1960s · USCG Great Lakes District (CGD-GL) · Other hulls named GRATITUDE
GRATITUDE is a 1969 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1985, most recently in May 2026, along with 74 deficiencies, 2 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2013.
Records from 1985 to 2026. Most recent: inspection, 22 May 2026.
- Built
- 1969
- Last inspected
- 22 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 74 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
- Casualties
- 1 investigation · 2013
Identity
645494
WDN8602
54622
Flag
UNITED STATES
366048000, 366815290, 368319170 (licence lapsed)
Maury page id
psix-54622
Inspections, by type
…with no type recorded10
Years with a record
34 calendar years (1985–2026)
The 61 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)38.9 ft × 12.0 ft × 5.2 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEBBERS COVE BOAT YARD · EAST BLUE HILL, ME, UNITED STATES · built 1969
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSTURGEON BAY, WI
Trade endorsementsRegistry
DocumentationValid · issued 12 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN8602MMSI 368319170 · cancelled · compulsorily equipped · granted 9 June 2023, cancelled 13 April 2026
WDH8315MMSI 366815290 · expired · compulsorily equipped · granted 11 February 2015, cancelled 19 April 2025
WDA4995MMSI 366815290 · expired · compulsorily equipped · granted 14 June 2001, cancelled 20 August 2011
WAK7622MMSI 366048000 · expired · compulsorily equipped · granted 6 April 1995, cancelled 25 June 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 61
22 May 2026
Vessel Attendance · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8378369
5 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8227637
19 July 2024
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7964133
28 June 2023
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7738103
7 April 2023
Examination of Repairs · Drydock Exam · Annual Survey · DAPI Audit · Internal Structural Exam · Plan Review "T" Boat · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7672584
6 March 2020
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6921858
8 May 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6679390
26 September 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6549310
16 May 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6415902
2 May 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6137014
30 September 2016
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6013048
4 May 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5868684
14 May 2012
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4310883
7 May 2012
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4304387
1 December 2011
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4199473
22 September 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3854711
8 February 2010
COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3676887
16 April 2009
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3453630
18 September 2008
Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3327194
21 April 2008
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3188676
18 April 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2910102
29 September 2006
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2789776
11 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2621837
21 December 2004
COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2259672
23 September 2004
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2202805
19 September 2003
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1905122
22 October 2002
Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1694035
17 June 2002
Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1631989
2 August 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1075059
20 June 2001
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1425147
18 June 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1460545
18 May 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1399658
9 February 2000
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 815728
10 August 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1111500
30 December 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 809399
11 December 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 808434
2 September 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 797361
23 April 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789735
14 January 1998
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783760
4 July 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781741
29 March 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 88426
13 July 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 186198
15 April 1996
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082875
5 December 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883140
24 April 1995
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1189826
19 April 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174436
11 March 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 140644
2 November 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839747
23 April 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828261
14 April 1993
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 835593
1 October 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1249193
2 May 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1306382
22 March 1990
Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 916763
2 August 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 893244
5 May 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1037060
16 March 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1030389
31 July 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1312734
16 January 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 999757
16 October 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1302359
10 June 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 981776
7 June 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1289697
Deficiency record · 74
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 May 2026
Resolved
Vessel's fixed fire system (fireboy) was accidentally set off, rendering the system inoperable
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 September 2025
Resolved
Vessel only had electronic distress signal which does not meet the requirements of Sub T
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2024
Resolved
Fire buckets available on board were too large and unmarked. Provided the correct fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2024
Resolved
Decommission 05 life jackets due to damages. Renew lifejackets with approved type. Reduce passenger count to a maximum of 31 until life jackets are renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 July 2024
Resolved
Original COI must be present on board. COI was lost and only a copy was present. Provided a new copy to vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 13 March 2020
Resolved
Provide current employee list. 46 CFR 16
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 March 2020
Resolved
Provide current FCC Safety Certificate. Operations reduced to no more than 1000 feet from shore. 47 CFR 80
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 March 2020
Resolved
Conduct satisfactory drills. 46 CFR 185.520
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 June 2019
Resolved
Provide proof of enrollment in drug consortium and provide MIS report. 46 CFR 16.201
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2019
Resolved
Replace non-serviceable life ring buoy. 46 CFR 180.70
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2019
Resolved
Replace non-serviceable life jackets. Label all life-jackets. Reduced total persons to 26. 46 CFR 180.71
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 June 2019
Resolved
Install DSC Class D radio or equivalent providing GPS coordinates when emergency distress button is depressed. Restricted to no more than 1000 feet from shore.
47 CFR 80.905
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 5 June 2019
Resolved
Post emergency instructions and life jacket donning placard.
46 CFR 185.510
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2019
Resolved
Provide drill and EPIRB logs. 46 CFR 185.524
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2019
Resolved
Label emergency fuel shut off valves. 46 CFR 185.608
Engineering › Fuel Oil Service System › Valve
Issued 7 May 2012
Resolved
Properly install fuel shut-off valve located at or near engine.
Engineering › Steering Gear System › Rudder
Issued 7 May 2012
Resolved
Properly install rudder stops.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 May 2012
Resolved
Properly install engine belt guard.
Documentation › Markings/Placards › Warning Signs
Issued 7 May 2012
Resolved
Re-label fuel shut-off valve.
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 May 2012
Resolved
Replace retro-reflective tape on both life-floats.
Lifesaving › Lifefloat › Serviceable
Issued 7 May 2012
Resolved
Properly repair small cracks on top side of life-floats.
Documentation › Certificates/Documents › FCC SSL
Issued 8 February 2010
Resolved
PROVIDE A VESSEL FCC RADIO SAFETY TELEPHONEY CERTIFICATE.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 8 February 2010
Resolved
PROVIDE THREE RED HAND HELD DISTRESS FLARES.
Engineering › Bilge Water Management System › Not Operational
Issued 8 February 2010
Resolved
DEMONSTRATE PROPER OPERATION OF THE AFT HIGH BILGE ALARM INDICATOR AT THE OPERATING STATION.
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 April 2009
Resolved
Install blocking to secure batteries from movement.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 16 April 2009
Resolved
Clean and renew retroreflective tape on life jackets as needed.
Electrical › Electric Supply System (service) › Cable
Issued 16 April 2009
Resolved
Remove or secure wire in forward compartment.
Engineering › Bilge Water Management System › Hose
Issued 16 April 2009
Resolved
Install second hose clamp on bilge overboard discharge.
Engineering › Bilge Water Management System › Not Operational
Issued 16 April 2009
Resolved
Prove proper operation of portable bilge pump.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 April 2009
Resolved
Renew line on port lifefloat waterlight.
Lifesaving › Lifefloat › Markings
Issued 21 April 2008
Resolved
Label life float with vessels name.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 April 2008
Resolved
Repair floating water light for life float.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 April 2008
Resolved
Renew 01 adult and 01 child type I PFD.
Engineering › Fuel Oil Service System › Valve
Issued 21 April 2008
Resolved
Install fuel shut of valve at the filter.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 April 2008
Resolved
Properly label remote fuel tank shut off valve.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 21 April 2008
Resolved
Close all aft engine room bulkhead openings to prevent fire extinguisher gas from being ineffective.
Construction/Loadline › Structures › Ventilators
Issued 21 April 2008
Resolved
Provide engine room ventilation and a means to close in a fire situation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 April 2007
Resolved
Complete annual fire fighting equipment servicing.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 April 2006
Resolved
Renew life jacket donning placard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 11 April 2006
Resolved
Renew and provide two BII portable fire extinguishers on forward and aft sides of the engine compartment.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2006
Resolved
Repair all around white light to properly illuminate.
Lifesaving › Lifefloat › Float Free
Issued 11 April 2006
Resolved
Properly arrange life floats to make float free.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2006
Resolved
Starboard lifefloat light not illuminating, repair light.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 April 2006
Resolved
Properly mount floating waterlight bracket on portside lifefloat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 April 2006
Resolved
Provide proof of enrollment in a drug testing program.
Documentation › Certificates/Documents › FCC SSL
Issued 11 April 2006
Resolved
Provide proof of FCC safety certificate.
Lifesaving › Lifefloat › Paddle
Issued 21 December 2004
Resolved
Attach paddles inside life float IAW 46CFR180.175(e)(2)
Lifesaving › Lifefloat › Lifeline
Issued 21 December 2004
Resolved
Replace all life lines, sea painters and water light lanyards for both life floats. Vessel restricted to rivers route only until this requirement is cleared.
Engineering › Fuel Oil Service System › Valve
Issued 21 December 2004
Resolved
Install emergency fuel shut off for port fuel tank IAW 46CFR176.804(f), 182.455(b)(4)
Lifesaving › Buoyant Apparatus
Issued 19 September 2003
Resolved
PROVIDE TWO FOUR FOOT PADDLES FOR EACH LIFEFLOAT INSTALLED ON VESSEL IAW 46 CFR 180-15-5 (B) LEGACY COMPONENT DESC: paddels
Engineering › Steering Gear System
Issued 19 September 2003
Resolved
INSTALL TWO LOCKING NUTS, ONE NUT WITH COTTER PIN, OR ONE NYLOCK NUT STEERING TILLER ARM IAW 46 CFR 176.800. LEGACY COMPONENT DESC: Fastener
Documentation › Logs/Records
Issued 19 September 2003
Resolved
PROVIDE A LOGBOOK FOR REQUIRED TRAINING IAW 46 CFR 185.420. LEGACY COMPONENT DESC: Logbook (official)
Engineering › Fuel Oil Service System
Issued 19 September 2003
Resolved
INSTALL A FLAME BOWL AND METALLIC DRAIN WITH CAP ON MAIN ENGINE FUEL OIL FILTER IAW 46 CFR 182.455 (6) LEGACY COMPONENT DESC: Filter
Engineering › Sea-water System (primary cooling)
Issued 17 June 2002
Resolved
SECONDARY SEACHEST VALVE INCLUDED A NIPPLE PROTRUDING FROM VALVE BONNET AND NOT PROVIDED WITH CAP OR PLUG. LEGACY COMPONENT DESC: Valve
Construction/Loadline › Penetrations
Issued 17 June 2002
Resolved
THROUGH HULL FITTING FWD COMPARTMENT NOT CAPPED OR SEALED. LEGACY COMPONENT DESC: THROUGH HULL FITTING
Documentation
Issued 2 September 1998
Resolved
POST COPY OF STABILITY LETTER.
Documentation
Issued 2 September 1998
Resolved
PROVIDE UPDATED FCC SAFETY RADIO TELEPHONY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 2 September 1998
Resolved
RENEW BOTH LIFEFLOAT WATERLIGHT LANYARDS.
Construction/Loadline
Issued 2 September 1998
Resolved
RENEW FORWARD HATCH COVER.
Documentation
Issued 2 September 1998
Resolved
PROVIDE PROOF OF CREW ENROLLMENT IN DRUG TESTING CONSORTIUM.
Documentation
Issued 2 September 1998
Resolved
PROVIDE COPY OF MASTER'S FCC OPERATORS LICENSE.
Documentation
Issued 2 September 1998
Resolved
PROVIDE PROOF OF USER FEE PAYMENT._x001C_
Construction/Loadline
Issued 14 January 1998
Resolved
REMOVE OILY WATER FROM ALL BILGES.
Construction/Loadline
Issued 14 January 1998
Resolved
REPAIR DECK IN WAY OF HEAD.
Electrical
Issued 14 January 1998
Resolved
CLEAN BATTERY TERMINALS AND PROVIDE BOX AND COVER.
Construction/Loadline
Issued 14 January 1998
Resolved
CROP AND RENEW STBD DECK SECTION BETWEEN AFT BATTERY STORAGE HATCH TO SEAM.
Accommodation/Occupational Safety
Issued 14 January 1998
Resolved
PROVIDE HANDLE FOR MSD DISCHARGE VALVE OR REMOVE AND CAP THROUGH-HULL FITTING.
Documentation
Issued 14 January 1998
Resolved
PROVIDE A 1996 0R LATER EDITION OF 46 CFR PARTS 166-199.
Accommodation/Occupational Safety
Issued 14 January 1998
Resolved
REPAIR CRACKED WELDS IN WAY OF CENTER DIVE PLATFORM SUPPORTS.
Documentation
Issued 4 July 1997
Resolved
POST A COPY OF THE STABILITY LTR.
Documentation
Issued 15 April 1996
Resolved
POST A COPY OF THE STABILITY LTR.
Documentation
Issued 23 April 1993
Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO MSO MIAMI.
Engineering
Issued 23 April 1993
Resolved
PROVIDE ADQUATE SUPPORT FOR THROTTLE CONTROL.
Unknown
Issued 2 August 1989
Resolved
TWENTY ITEM WORK LIST ATTACHED TO BOOK. OWNER NOT OPERATING VESSEL, LOOKING TO SELL VESSEL.
Casualty record · 1
19 November 2013Routine · role: Transiting Vicinity of Primary Subject · activity 4755686
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SEAFARE (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.