MAURY USCG vessel records Sign in
← All vessels

FALCON

FALCON is a 1976 freight barge. The Coast Guard has recorded 32 inspections since 1985, most recently in March 2003, along with 19 deficiencies.

Records from 1985 to 2003. Most recent: inspection, 10 March 2003.

Built
1976
Last inspected
10 March 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7533733 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCW8203
Flag
UNITED STATES
—
Maury page id
psix-54627

Inspections, by type

…with no type recorded6
Years with a record 16 calendar years (1985–2003)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it7105 - Regulatory (Subpart C or D), Gross Ton
19258 - Convention (Subpart B), Gross Ton
7105 - Regulatory (Subpart C or D), Net Ton
8896 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCW8203MMSI not assigned · expired · compulsorily equipped · granted 21 August 1996, cancelled 21 October 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 32

10 March 2003 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1755102
15 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113811
28 December 1998 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810399
17 December 1998 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 808475
20 October 1998 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1131904
16 September 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 804624
7 May 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 793310
15 August 1997 Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455520
2 December 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 676050
20 September 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 199464
20 September 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1137391
20 September 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1430279
10 September 1996 Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421262
14 August 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396579
28 February 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 885387
8 September 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1394374
13 December 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1153137
9 May 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 366589
8 October 1993 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1456131
21 December 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1136206
14 September 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 930712
17 September 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1259552
17 September 1991 Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1310517
12 October 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 918562
9 November 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1211379
14 April 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1032370
25 March 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038775
24 October 1988 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 888656
24 March 1988 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 893636
7 January 1987 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1318235
31 January 1986 Re-Inspection · Credit Drydock
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1304531
9 January 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1288554

Deficiency record · 19

Accommodation/Occupational Safety
Issued 15 August 1997 Resolved
INSTALL SAFETY CHAINS AT LADDERS
Condition: Unknown
Due 15 September 1997
Resolved 2 October 1997
Electrical
Issued 15 August 1997 Resolved
MAKE ELECTRICAL PANEL WATER TIGHT AND MARK CIRCUITS ON PORT SIDE MAIN DECK
Condition: Unknown
Due 15 September 1997
Resolved 2 October 1997
Accommodation/Occupational Safety
Issued 15 August 1997 Resolved
REPAIR LIFELINES IN WAY OF 02 DECK
Condition: Unknown
Due 18 August 1997
Resolved 2 October 1997
Electrical
Issued 15 August 1997 Resolved
REPAIR LIGHTS IN WAY OF 01 DECK PORT SIDE
Condition: Unknown
Due 15 September 1997
Resolved 2 October 1997
Construction/Loadline
Issued 15 August 1997 Resolved
REPAIR WASTED FLANGES ON OUTBOARD DECK LONGITUDINALS (IN OVERHEAD)
Condition: Unknown
Due 15 August 1997
Resolved 15 August 1997
Accommodation/Occupational Safety
Issued 15 August 1997 Resolved
REPAIR WASTED RAILS & BULWORKS ON 1ST AND 3RD DECKS
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Construction/Loadline
Issued 15 August 1997 Resolved
REPAIR STBD BALLAST PUMP
Condition: Unknown
Due 15 August 1997
Resolved 2 October 1997
Engineering
Issued 15 August 1997 Resolved
PROVIDE DOCUMENTATION OF TESTS OF FUEL TRANSFER HOSE
Condition: Unknown
Due 15 September 1997
Resolved 2 October 1997
Construction/Loadline
Issued 15 August 1997 Resolved
MAKE PERMINENT REPAIRS TO PORT AFT CORNER WRAPPER AND BULWORK IN WAY OF MOORING WINCH, PRIOR TO SAILING
Condition: Unknown
Due 18 August 1997
Resolved 2 October 1997
Electrical
Issued 15 August 1997 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON STARBOARD GENERATOR
Condition: Unknown
Due 15 September 1997
Resolved 2 October 1997
Engineering
Issued 15 August 1997 Resolved
INSTALL LAGGING ON PORT GENERATOR EXHAUST
Condition: Unknown
Due 15 September 1997
Resolved 2 October 1997
Engineering
Issued 20 September 1996 Resolved
Remove round sight glass with out self closing valves used on generator F/Otank. (ABS rules 4/6.41.3 require flat glass type with approved self- closing valves at each end if glass gauge installed)
Condition: Unknown
Due 20 September 1996
Resolved 20 September 1996
Lifesaving
Issued 14 August 1996 Resolved
REPAIR SAFETY CHAINS THROUGH OUT VESSEL.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Electrical
Issued 14 August 1996 Resolved
REMOUNT LIGHTS AND JUNCTION BOXES THROUGH OUT VESSEL.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Engineering
Issued 14 August 1996 Resolved
REPLACE PLASTIC SIGHT GAUGE WITH GLASS SIGHT GAUGE ON GENERATOR FUEL TANK.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Navigation
Issued 14 August 1996 Resolved
REPLACE STERN NAVIGATION AND FLOAT LIGHT WIRING.
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Deck/Cargo
Issued 8 September 1995 Resolved
PROVIDE VERIFICATION FROM ABS TO THE FITNESS OF THE PORT AND STARBOARD ANCHOR WINDLASS AND MOORING EQUIPMENT BY NEXT ABS SURVEY NLT 29FEB96
Condition: Unknown
Due 8 September 1995
Resolved 8 September 1995
Electrical
Issued 24 October 1988 Resolved
CONDUCT AN OPERATIONAL TEST OF THE PORT AND STARBOARD GENERATORS AND PRIME MOVER OVERSPEED DEVICES AND ALARMS.
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988
Electrical
Issued 24 October 1988 Resolved
REMOVE OR REPLACE THE BRASS FITTINGS ON THE S/S GENERATOR FUEL TANK SIGHT GLASS. IF REPLACED, FITTINGS MUST MEET THE REQUIREMENTS OF 46 CFR 58.50-10(A)(6).
Condition: Unknown
Due 24 October 1988
Resolved 24 October 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.