← All vessels
T-5500
T-5500 is a 1952 tank barge. The Coast Guard has recorded 30 inspections since 1983, most recently in January 1995, along with 8 deficiencies.
Records from 1983 to 1995. Most recent: inspection, 26 January 1995.
- Built
- 1952
- Last inspected
- 26 January 1995
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
264755
54630
Flag
UNITED STATES
—
Maury page id
psix-54630
Inspections, by type
…with no type recorded16
Years with a record
13 calendar years (1983–1995)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it583 - Regulatory (Subpart C or D), Gross Ton
583 - Regulatory (Subpart C or D), Net Ton
583 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
26 January 1995
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 825734
2 June 1994
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1172007
30 June 1993
Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 841818
30 June 1992
Deficiency Check · COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1259771
30 June 1992
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1259772
23 April 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 642091
26 March 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 457264
26 March 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1260121
25 March 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 153640
20 September 1991
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1002456
26 August 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 529288
4 June 1991
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 929849
13 December 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 510749
10 August 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901805
10 May 1990
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 517895
19 October 1989
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 531966
29 September 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022063
28 December 1988
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 450735
6 December 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209652
14 November 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 464738
16 October 1987
Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1324172
11 September 1987
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 487148
10 December 1986
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 452636
12 November 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327178
2 July 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 517798
14 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988871
30 April 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 473176
28 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285705
10 September 1984
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 478775
28 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968271
Deficiency record · 8
Construction/Loadline
Issued 2 June 1994
Resolved
COMPLETE DRYDOCK, CARGO TANK INTERNAL, INTERNAL STRUCTURAL EXAM, ALONG WITHCOMPLETE REINSPECTION PRIOR TO PLACING THE VESSEL BACK IN SERVICE.
Construction/Loadline
Issued 30 June 1993
Resolved
PRIOR TO PLACING THE VESSEL BACK IN SERVICE, PRESENT THE VESSEL FOR A DRYDOCK EXAM.
Deck/Cargo
Issued 30 June 1993
Resolved
PRIOR TO PLACING THE VESSEL BACK IN SERVICE, PROVIDE EVIDENCE OF A HYDROSTATIC TEST OF THE CARGO PIPING SYSTEM.
Deck/Cargo
Issued 30 June 1993
Resolved
PRIOR TO PLACING THE VESSEL BACK IN SERVICE, DEMONSTRATE PROPER OPERATION OF THE CARGO PUMP ENGINE EMERGENCY SHUTDOWN.
Deck/Cargo
Issued 30 June 1993
Resolved
PRIOR TO PLACING THE VESSEL BACK IN SERVICE, PRESENT THE VESSEL FOR A CARGOTANK INTERNAL EXAM.
Construction/Loadline
Issued 30 June 1993
Resolved
PRIOR TO PLACING THE VESEL BACK IN SERVICE, PRESENT THE VESSEL FOR AN INTERNAL STRUCTURAL EXAM.
Construction/Loadline
Issued 30 June 1992
Resolved
PRIOR TO PLACING THE VESSEL BACK IN SERVICE, RENEW ALL SIDE SHELL PLATING, WHICH HAS BEEN IDENTIFIED IN ASHLAND OIL'S GAUGING REPORT DATED 28APR92, ASLESS THAN 0.281 INCHES.
Construction/Loadline
Issued 26 March 1992
Resolved
Identify the location of and make permanent repairs to the hole located in the sideshell plating in way of the #3 port cargo tank prior to loading thevessel and not later than the compliance date.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.