Records from 1984 to 2001. Most recent: inspection, 19 May 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 60
19 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064015
19 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 825349
10 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818758
24 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817084
15 February 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 175829
7 January 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 814668
4 January 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417009
8 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119657
11 January 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1395088
14 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807748
30 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794780
28 April 1998
Deficiency Check · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1398902
8 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 132701
2 January 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388423
22 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782933
16 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110758
10 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 654620
3 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 114430
17 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093266
12 December 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433128
19 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764473
17 September 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 654617
6 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254663
26 August 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193985
18 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092400
16 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193479
13 May 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082509
8 April 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1078230
15 December 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1377569
25 April 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1194576
20 December 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1435566
20 December 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1446200
13 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 17380
6 December 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1162607
30 November 1993
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853161
22 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 650435
18 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 141317
28 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155452
17 June 1993
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 842403
29 April 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845799
5 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 670692
27 March 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945967
22 February 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255360
22 January 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 951512
16 January 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263123
10 December 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258936
27 June 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1230004
13 November 1990
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 928530
3 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214830
9 April 1990
Deficiency Check · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239606
5 December 1989
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1228110
29 September 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1320656
6 October 1988
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1201160
20 January 1988
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1019775
15 September 1987
COI Inspection · Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332131
3 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020815
25 September 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005046
1 December 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986612
12 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288386
1 September 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 976840
Lifesaving
Issued 4 January 2000
Resolved
INSTALL RETROREFLECTIVE TAPE ON LIFE RING BUOYS AS NECESSARY.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Fire Fighting
Issued 4 January 2000
Resolved
PROVIDE APPROVED AND UPDATED FIRE CONTROL/SAFETY PLAN FROM CLASS SOCIETY.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Fire Fighting
Issued 4 January 2000
Resolved
PROPERLY SEAL OFF BULKHEAD PENETRATIONS AT GALLEY MAIN ENTRANCE.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Accommodation/Occupational Safety
Issued 4 January 2000
Resolved
INSTALL PROPER 100PSI SAFETY RELIEF VALVES ON THREE HOT WATER HEATERS.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Lifesaving
Issued 4 January 2000
Resolved
IMPLEMENT MEANS TO ADEQUATELY TRACK/RECORD PERSONNEL TRAINING IN LIFESAVINGAND FIREFIGHTING APPLIANCES EVERY TWO MONTHS, IN ACCORDANCE WITH 46CFR109.213.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Fire Fighting
Issued 4 January 2000
Resolved
PROVIDE ADDITIONAL GENERAL ALARMS IN THE ENGINE ROOM FOR ADEQUATE COVERAGE.REMOVE VOLUME CONTROLS FROM GAITRONICS ALARM SYSTEM THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Fire Fighting
Issued 4 January 2000
Resolved
VERIFY CO2 PORTABLE EXTINGUISHERS, AS LISTED ON GULFWIDE SAFETY REPORT 21DEC99, IF THEY REQUIRE A 5 YR. OR 10 YR. HYDROSTATIC TEST.
Condition: Unknown
Due 4 January 2000
Resolved 4 January 2000
Documentation
Issued 4 January 2000
Resolved
PROVIDE USCG APPROVED EEP FROM TAYLOR ENERGY ON BOARD RIG.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Lifesaving
Issued 2 January 1998
Resolved
Label fuel oil valve release station, partial ventilation shut down switches, emergency shutdowns on drill floor, and fire hose stations throughout rig.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Prove proper operation of purge system and alarms on drill floor. To be completed prior to drilling operations commence.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Engineering
Issued 2 January 1998
Resolved
Replace broken sightglasses (mud pump room and engine room), and install sturdy protection around sight glasses.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Fire Fighting
Issued 2 January 1998
Resolved
Indicate structural fire protection boundaries on Fire Control PLan, submitto [name withheld] for review.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Unknown
Issued 2 January 1998
Resolved
Show proper operation of drill floor air receiver relief valve.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Electrical
Issued 2 January 1998
Resolved
Adjust limit switches for both lifeboats so as to allow at least 6 inches of bumper clearance when bringing lifeboat into stored position.
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Prove proper operation of large overhead battery Emergency lights (red lights) for both lifeboat embarkation stations.
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Recharge empty breathing air cylinder in lifeboat #2, repair leaking valve to same (forward, outboard bottle).
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Replace expired PFD light to 1 drill floor PFD, and replace missing whistleto 1 hospital PFD.
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Repair or replace life jacket box on drill floor.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Lifesaving
Issued 2 January 1998
Resolved
Prove operation of loss of ventilation alarm for mud pit room on drill floor panel.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Permanently mount light under drill floor (behind cooling water tank for drawworks).
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Remove/place in junction box, loose wire above main deck door into hospitalspace.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Engineering
Issued 2 January 1998
Resolved
Provide f/o system diagram and transfer procedures at pumping station.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Unknown
Issued 2 January 1998
Resolved
Provide 1 certified oiler and 1 assistant engineer as specified in the SafeManning Certificate, or provide exemption/equivalency from flag state before sailing.
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Mount light switch to illuminate lifeboat launch area, adjacent to lifeboat#1, stbd side.
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Prove proper operation of aft limit switch for lifeboat station #1 (damagedby tarp).
Condition: Unknown
Due 6 January 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Plug cable run holes in explosionproof covers (2) on drill floor.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Electrical
Issued 2 January 1998
Resolved
Clean, reset, and show proper operation of ventilation dampners for engine room.
Condition: Unknown
Due 6 February 1998
Resolved 7 January 1998
Documentation
Issued 12 December 1996
Resolved
PROVIDE FULL-TERM CERTIFICATE OF REGISTRY.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Fire Fighting
Issued 12 December 1996
Resolved
REPAIR VENTILATION SHUT-DOWN AND FIXED CO2 SYSTEM ON PAINT LOCKER.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Unknown
Issued 12 December 1996
Resolved
PROVIDE TRAINING PLAN TO [name withheld] TRAINING ON EXTINGUISHINGMENT OF DIFFERENT CLASSES OF FIRES, SCBA USEAGE, PROPER USAGE OF FIRE FIGHTING AND LIFESAVING EQUIP, ETC. SUBMIT LOGS FOR SAME AFTER TWO MONTHS VERIFYING COMPLIANCE WITH PLAN.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 12 December 1996
Resolved
RENEW STUFFING TUBES IN SHALE SHAKER AREA.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Engineering
Issued 12 December 1996
Resolved
PLACE TRANSFER PROCEDURES, IAW 33 CFR 155.750, AT EA LOCATION PERSONNEL WILL BE STATIONED DURING TRANSFER OPS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Unknown
Issued 12 December 1996
Resolved
REPAIR INTERNAL COMMS SYSTEM TO GENERATOR ROOM.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 12 December 1996
Resolved
REPLACE RELIEF VALVES ON AIR COMPRESSORS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 12 December 1996
Resolved
REMOVE "DUAL RIG" FROM HULL; MARK STERN WITH PORT OF REGISTRY.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Fire Fighting
Issued 12 December 1996
Resolved
REMOVE HELO FUELING FOAM SYSTEM OR MAKE OPERATIONAL.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Lifesaving
Issued 12 December 1996
Resolved
PROVIDE FOR BOTH LIFEBOATS: LABEL WITH UNIT NAME ON TOP OF BOAT; LABEL BOTHSIDES OF BOAT WITH PROPER INFORMATION; PAINT BOAT RELEASES RED; REPLACE LIGHTS ON PFD'S; SECURE BOAT PLUGS WITH CHAIN; PROVIDE SEA SICKNESS KITS, SEARCHLIGHTS, AND THERMAL PROTECTIVE AIDS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 12 December 1996
Resolved
MAKE MUD PIT ROOM DOORS SELF-CLOSING AND GAS TIGHT.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Electrical
Issued 12 December 1996
Resolved
REPAIR EMERGENCY LIGHTS AND LABEL TROUGHOUT RIG.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Documentation
Issued 12 December 1996
Resolved
PROVIDE APPROVED EMERGENCY EVACUATION PLAN.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 12 December 1996
Resolved
MAKE PERMENANT REPAIRS TO AIR CONDITIONING, REFRIGERATION, AND MSD TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Engineering
Issued 12 December 1996
Resolved
REPLACE VALVE AND PROPERLY STENCIL FUEL TRANSFER HOSE.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 12 December 1996
Resolved
REPLACE WASTED BILGE SYSTEM VALVES AND TIGHTEN ALL LEAKING CONNECTIONS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 12 December 1996
Resolved
REPLACE SANITARY WATER PRESSURE VESSEL AND ASSOCIATED PIPING.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Electrical
Issued 12 December 1996
Resolved
REPAIR RADIATOR ON GENERATOR #3 AND PROVE OPERATION OF ALL EMERGENCY SHUT- DOWNS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Unknown
Issued 12 December 1996
Resolved
MAKE PERMANENT REPAIRS TO OWS. SECURE/LOCK OVERBOARD DISCHARGE VALVE UNTIL SYSTEM IS FUNCTIONING PROPERLY.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Documentation
Issued 12 December 1996
Resolved
PROVIDE APPROVED FIRE CONTROL AND LIFE SAVING EQUIPMENT PLAN. POST ON RIG. REMOVE OLD PLANS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 12 December 1996
Resolved
GUAGE PITTED AREAS OF BULK TANKS. PROVIDE UIA AND GUAGING REPORTS FOR BULK TANKS TO [name withheld].
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Documentation
Issued 12 December 1996
Resolved
PROVIDE FULL-TERM MODU CODE SAFETY CERTIFICATE.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Lifesaving
Issued 12 December 1996
Resolved
SET UP LIFE RAFT STATIONS FOR FLOAT-FREE ARRANGEMENT.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 12 December 1996
Resolved
REPAIR WTD INDICATORS AND ADJUST WTD'S THROUGHOUT RIG.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Lifesaving
Issued 12 December 1996
Resolved
REPLACE 21 OUTDATED LIFE PRESERVER LIGHTS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 12 December 1996
Resolved
CLEAN VENT SCREENS IN ACCOMMODATION RESTROOMS; REPLACE CEILING TILES AS NEC.; ADJUST WEATHER-TIGHT DOOR, PORT SIDE 2ND DECK.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 12 December 1996
Resolved
MAKE PERMENANT REPAIRS TO FRESH WATER AND SANITARY WATER PIPING THROUGHOUT RIG TO SATISFACTION OF CLASSIFICATION SOCIETY.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Construction/Loadline
Issued 12 December 1996
Resolved
MAKE REPAIRS TO JACKING LEGS IAW ABS DAMAGE SURVEY REPORT OF 12 DEC96.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Unknown
Issued 12 December 1996
Resolved
PLACE 100 PSI SAFETY RELIEF VALVES ON ALL HOT WATER HEATERS.
Condition: Unknown
Due 12 December 1996
Resolved 12 December 1996
Accommodation/Occupational Safety
Issued 6 December 1993
Resolved
MAKE READY FOR INTERNAL INSPECTION ALL PRESSURE VESSELS.
Condition: Unknown
Due 29 March 1994
Resolved 5 April 1994
Construction/Loadline
Issued 6 December 1993
Resolved
PROVIDE POLLUTION PLACARDSAS INDICATED IN ALL LOCATIONS DISCRIBED IN 33 CFR155.450
Condition: Unknown
Due 18 January 1994
Resolved 27 January 1994
Lifesaving
Issued 6 December 1993
Resolved
REPLACE OR REPAIR RELEASE HOOK FOR PORT DAVIT LAUCHED LIFE RAFT.
Condition: Unknown
Due 18 January 1994
Resolved 27 January 1994
Lifesaving
Issued 6 December 1993
Resolved
PROVIDE TWO(2) LIFE RINGS FOR STARBOARD SIDE MAIN DECK.
Condition: Unknown
Due 18 January 1994
Resolved 27 January 1994
Lifesaving
Issued 6 December 1993
Resolved
CONDUCT FIRE AND BOAT DRILL IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 18 January 1994
Resolved 27 January 1994
Fire Fighting
Issued 6 December 1993
Resolved
PROVE PROPER OPERATION OF CO2 TIME DELAY
Condition: Unknown
Due 18 January 1994
Resolved 26 January 1994
Electrical
Issued 6 December 1993
Resolved
INSTALL BLANKS IN OPENINGS IN ALL ELECTRICAL PANALS; A/C & DUCT HEATER PANEL IN GALLEY, "E" LIGHTING PANEL ON MAIN DECK, BROKEN BREAKER IN PANEL IN WAY OF HALON BOTTLES(#10 BREAKER).
Condition: Unknown
Due 18 January 1994
Resolved 26 January 1994
Unknown
Issued 6 December 1993
Resolved
PROVIDE FUELING STATION FOR FORKLIFT AS REQUIRED.
Condition: Unknown
Due 18 January 1994
Resolved 26 January 1994
Accommodation/Occupational Safety
Issued 6 December 1993
Resolved
PROVE PROPER OPERATION OF PRESSURE VESSEL RELEIF VALVES.
Condition: Unknown
Due 29 March 1994
Resolved 5 April 1994
Electrical
Issued 6 December 1993
Resolved
CONDUCT NECESSARY TEST FOR ALL SHIP SERVICE GENERATORS.
Condition: Unknown
Due 29 March 1994
Resolved 5 April 1994
Fire Fighting
Issued 6 December 1993
Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 18 January 1994
Resolved 27 January 1994
Construction/Loadline
Issued 6 December 1993
Resolved
PROVIDE STANDARD DISCHARGE CONNECTION AS PER 33 CFR 155.450
Condition: Unknown
Due 29 March 1994
Resolved 5 April 1994
Electrical
Issued 6 December 1993
Resolved
TEST OVERSPEED AND AUTO BUSS TRANSFER FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 29 March 1994
Resolved 5 April 1994
Unknown
Issued 6 December 1993
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR
Condition: Unknown
Due 18 January 1994
Resolved 26 January 1994
Documentation
Issued 29 April 1993
Resolved
PROVIDE COPY OF CURRENT LOADLINE CERTIFICATE. TO BE COMPLETED TO THE SATISFACTION OF COGNIZANT OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Fire Fighting
Issued 29 April 1993
Resolved
PROVE PROPER OPERATION OF LEL AND H2S INDICATOR USING APPROPRIATE SPAN GAS.TO BE COMPLETED TO THE SATISFACTION OF COGNIZANT OCMI OR ATTENDING CG MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Fire Fighting
Issued 29 April 1993
Resolved
MAKE PERMANENT REPAIRS ON FIREMAIN SYSTEM FROM AUXILIARY MACHINERY ROOM THRU THE SACK ROOM TO THE MUD PUMP ROOM. SYSTEM TO BE HYDRO TESTED @ 1.5 MAWP UPON COMPLETION OF REPAIRS IN THE PRESENCE OF ATTENDING CG MARINE INSPECTOR._x001C_
Condition: Unknown
Due 11 August 1993
Resolved 11 August 1993
Deck/Cargo
Issued 29 April 1993
Resolved
PROVIDE PROPER RELIEF VALVE WITH HAND RELIEVING GEAR FOR THE FOLLOWING PRESSURE VESSELS; MOTOR ROOM AIR RECEIVER, SACK ROOM AND AUXIALIARY MACHINERY ROOM AIR RECEIVER. TO BE COMPLETED TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR OR COGNIZANT OCMI._x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Fire Fighting
Issued 29 April 1993
Resolved
HYDRO TEST OR REPLACE 20, 100 LB CO2 BOTTLES IN THE ENGINEROOM FIXED FIRE EXTINGUISHING SYSTEM. TO BE COMPLETED TO THE SATISFACTION OF COGNIZANT OCMI._x001C_ _x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Electrical
Issued 29 April 1993
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR INCLUDING ALARMS AND SHUTDOWNS. TO BE COMPLETED TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR OF COGNIZANT OCMI._x001C_ _x001C_
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Documentation
Issued 22 February 1992
Resolved
PROVIDE A CURRENT LOAD LINE CERTIFICATE WITH THE APPLICABLE USCG STABILITY LETTER. COMPLIANCE MAY BE DONE BY CORRESPONDENCE AND PHOTOSTATIC COPY.
Condition: Unknown
Due 22 February 1992
Resolved 22 February 1992
Fire Fighting
Issued 16 January 1992
Resolved
PROVIDE A COPY OF THE CURRENT FOAM ANALYSIS.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Lifesaving
Issued 10 December 1991
Resolved
RENEW IN LIKE KIND AND QUALITY AS ORIGINAL LIFEBOAT EQUIPMENT TO PORT AND STARBOARD LIFEBOAT CAPSULES AS PER 46 CFR 94.20-10(A)
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Lifesaving
Issued 10 December 1991
Resolved
PROVIDE 2 FLOATING ORANGE SMOKE DISTRESS SIGNALS FOR RING LIFE BUOYS AS PER46 CFR 102.515(d)(1).
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Documentation
Issued 10 December 1991
Resolved
PROVIDE AN APPROVED AS PER 46 CFR 107.305 (HH) CONSTRUCTION PORTFOLIO. CONFIRMATION OF POSSESSION MAY BE MADE BY CORRESPONDENCE CERTIFIED BY OIM SIGNATURE AND LICENSE NUMBER.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Fire Fighting
Issued 10 December 1991
Resolved
PROVIDE A COPY OF THE CURRENT FOAM ANALYSIS.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Documentation
Issued 10 December 1991
Resolved
PROVIDE A CURRENT LOAD LINE CERTIFICATE WITH THE APPLICABLE USCG STABILITY LETTER. COMPLIANCE MAY BE DONE BY CORRESPONDENCE AND PHOTOSTATIC COPY.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Lifesaving
Issued 10 December 1991
Resolved
PROVIDE HAND HELD PARACHUTE FLARES AS PER 46 CFR 108.521.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Deck/Cargo
Issued 10 December 1991
Resolved
PROVIDE QUADRENNIAL CRANE TEST CERTIFICATE IN ACCORDANCE WITH 46 CFR 91.37.COMPLIANCE MAY BE DONE BY CORRESPONDENCE, AND PHOTOSTATIC COPY.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Lifesaving
Issued 10 December 1991
Resolved
PROVIDE A COPY OF WIRE ROPE SAFETY CERTIFICATE FOR DAVIT LAUNCHED LIFERAFT SYSTEM AND LIFEBOAT DAVIT FALLS.
Condition: Unknown
Due 10 December 1991
Resolved 10 December 1991
Documentation
Issued 13 November 1990
Resolved
PROVIDE REVISED OPERATIONS MANUAL AND SUBMIT THREE COPIES FOR APPROVAL TO ACCOUNT FOR ADDED LEG LENGHT.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Fire Fighting
Issued 13 November 1990
Resolved
PROVIDE REVISED FIRE CONTROL MANUAL TO SHOW NEW HALON SYSTEM.
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Engineering
Issued 13 November 1990
Resolved
RENEW TWO PRESSURE RELIEF DEVICES FOR AIR RECEIVER IN AUX MACHINERY ROOM AND AIR RECEIVER IN MOTOR ROOM
Condition: Unknown
Due 13 November 1990
Resolved 13 November 1990
Unknown
Issued 9 April 1990
Resolved
REPLACE BOTH PERSONNEL BASKETS, LINES SEVERELY DETERIORATED.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Unknown
Issued 9 April 1990
Resolved
REMARK SIGNS FOR EMERGENCEY ESCAPES FOR LEG LADDERS, PROVIDE NEW CHAINS FOR ACCESS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Fire Fighting
Issued 29 September 1989
Resolved
PROVIDE STAMPED CG APPROVED COPY OF FIRE CONTROL PLAN.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Documentation
Issued 29 September 1989
Resolved
PROVIDE STAMPED CG APPROVED COPY OF HAZARDOUS LOCATION CONTROL PLAN.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Documentation
Issued 29 September 1989
Resolved
PROVIDE UPDATED STAMPED CG APPROVED COPY OF OPERATIONS MANUAL.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Electrical
Issued 29 September 1989
Resolved
MAKE PURGE AIR SYSTEM AND ALARMS ON TOP DRIVE UNIT AVAILABLE FOR TESTING.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Electrical
Issued 29 September 1989
Resolved
PROVE PROPER OPERATION OF #3 MAIN GENERATOR.
Condition: Unknown
Due 29 September 1989
Resolved 29 September 1989
Electrical
Issued 6 October 1988
Resolved
MAKE PERMANENT REPAIRS TO THE LIGHT SWITCH FOR THE DAVIT-LAUNCHED RAFT EMBARKTION LIGHT ON THE PORTSIDE.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Documentation
Issued 6 October 1988
Resolved
PROVIDE A COPY OF USCG APPROVED FIRE/SAFETY PLAN FOR THE RIG.
Condition: Unknown
Due 6 October 1988
Resolved 6 October 1988
Documentation
Issued 15 September 1987
Resolved
PROVIDE CURRENT LOADLINE CERTIFICATE.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
INSTALL PROPER TYPE BATTERIES IN SWITCH BOARD GOVERNOR CONTROL.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REPAIR ANCHOR ALARM ON NO. 2 SERVICE GENERATOR.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REPAIR VISUAL ALARM ON NO. 3 GENERATOR.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF FIRE DAMPER ON THE PORT FORWARD QUARTER OF HOUSE NEXT TO BULK TANK.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
INSTALL EXPLOSIVE PROOF FITTING ON HYDRAULIC SWITCHES LOCATED ON DRILL FLOOR NEXT TO CONSOLE.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Accommodation/Occupational Safety
Issued 15 September 1987
Resolved
RENEW HOT WATER RELIEF VALVES ON TWO OF THE THREE HOT WATER TANKS.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REMOVE BOX LOCATED ON DECK OVER TOP OF SHALE SHAKER ROOM OR REPLACE WITH EXPLOSIVE-PROOF CONNECTION.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REPLACE BARKSDALE PRESSURE SWITCH LOCATED ON THE DRILL FLOOR BEHIND THE DRILLERS CONSOLE WITH AN EXPLOSIVE-PROOF FITTING.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REPLACE THE FITTING ON THE ALARM LOCATED NEXT TO THE BARKSDALE PRESSURE SWITCH LOCATED ON THE DRILL FLOOR DIRECTLY BEHIND THE DRILLING CONSOLE WITH AN EXPLOSIVE-PROOF FITTING.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVIDE THE TELEPHONE BOX LOCATED ON THE CEMENT DECK WITH EXPLOSIVE-PROOF FITTINGS.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Deck/Cargo
Issued 15 September 1987
Resolved
CONDUCT THE FOLLOWING TEST TO THE HELO FUELING SYSTEM: A. ANNAUL PRV AND VRV B. 30 MONTH INTERNAL C. 60 MONTH HYDRO
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF THE FOLLOWING ON THE EMERGENCY GENERATOR: A. OVERSPEED B. HIGH TEMPERATURE C. LOW LUBE OIL PRESSURE
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF THE RIG'S GENERAL ALARM SYSTEM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
REPLACE CABLES ON BOTH LIFESAVING CAPSULES DAVITS OR PROVE WHEN LAST REPLACED AND END FOR ENDED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
REPLACE CABLES ON BOTH DAVIT LAUNCH INFLATABLE LIFERAFT DAVIT ARMS OR PROVE WHEN LAST REPLACED AND END FOR ENDED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF EMERGENCY RADIO.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF EPIRB.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Accommodation/Occupational Safety
Issued 15 September 1987
Resolved
INSTALL CLOSING DEVICE NEXT TO FIRE STATION NUMBER 2.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVIDE 2 OF THE 4 WIRE CONNECTIONS TO THE JUNCTION BOX LOCATED ON THE CEMENT DECK AT THE TOP OF THE LADDER WITH EXPLOSIVE-PROOF FITTINGS.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVIDE BLANKS WHERE NEEDED IN THE COMMUNICATIONS CIRCUIT BREAKER PANEL LOCATED IN RADIO ROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REPLACE CORD OR PROVE CORD IS CONTINUOUS FOR TELEPHONE LOCATED IN THE MUD PIT ROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROPERLY SUPPORT WIRE HANGING FROM THE OVERHEAD NEXT TO THE AFTER BULKHEAD IN THE MUD PIT ROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF FIRE PUMPS.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF H2S ALARM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF THE PURGE ALARM SYSTEM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Deck/Cargo
Issued 1 December 1985
Resolved
PROVIDE USCG APPROVED PRESSURE RELIEF VALVES WITH HAND RELIEFING DEVICE FORBULK CEMENT TANKS.
Condition: Unknown
Due 1 December 1985
Resolved 1 December 1985