MAURY USCG vessel records Sign in
← All vessels

TIDEWINDS

TIDEWINDS is a 1978 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in April 2026, along with 50 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 16 April 2026.

Built
1978
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7201
Flag
UNITED STATES
367183170
Maury page id
psix-54643

Inspections, by type

…with no type recorded6
Years with a record 37 calendar years (1985–2026)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)32.6 ft × 12.1 ft × 5.3 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH MARINE INC · TACOMA, WA, UNITED STATES · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBROOKINGS, OR
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7201MMSI 367183170 · active · compulsorily equipped · granted 8 April 2017, expires 26 April 2027
WCZ4324MMSI not assigned · expired · voluntarily equipped · granted 5 August 1999, cancelled 10 October 2009
WCW5347MMSI not assigned · expired · compulsorily equipped · granted 16 July 1997, cancelled 8 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 60

16 April 2026 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8351351
8 May 2025 DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8131904
16 May 2024 Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7914317
26 April 2023 Hull Examination · Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7679675
11 May 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7450147
15 April 2021 DAPI Audit · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7179090
17 June 2020 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7012277
23 May 2019 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6728789
8 May 2019 Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6684170
18 May 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6418073
2 May 2017 Annual Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6208920
29 September 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6012685
28 September 2016 Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6017044
19 September 2016 Plan Review "T" Boat
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6004590
13 April 2016 COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5846832
10 July 2012 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4376831
27 August 2011 Type not recorded
No type recorded · Station Chetco River · USCG Northwest District (CGD-NW) · Activity 4128628
19 November 2010 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3897279
15 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179455
16 July 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3020896
5 July 2007 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2985759
11 June 2007 Deficiency Check · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2962961
29 March 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2626791
15 August 2005 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2496222
14 August 2005 Type not recorded
No type recorded · Station Chetco River · USCG Northwest District (CGD-NW) · Activity 2462807
19 May 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2369242
19 April 2005 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2318848
20 October 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2240076
3 April 2004 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2017669
18 June 2003 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1814338
26 April 2002 Annual Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1602271
3 April 2001 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1373474
26 April 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1058904
11 April 2000 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1464966
8 October 1999 Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1361202
21 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 46618
21 May 1999 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1432190
3 March 1999 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 800571
27 May 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 793549
7 April 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442699
1 December 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 776118
1 October 1997 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1375170
18 July 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1116142
12 May 1997 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385998
18 April 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1353936
28 November 1995 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385587
17 October 1995 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1191391
2 June 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1183599
9 May 1995 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1457265
19 April 1994 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1454070
27 October 1993 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1405446
19 May 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1419123
13 May 1992 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946939
23 April 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946027
5 June 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 929324
25 August 1989 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1031595
9 December 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1209777
25 June 1987 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1013499
21 July 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1316194
12 July 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 988381

Deficiency record · 50

05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 23 May 2019 Resolved
Provide valid FCC radio safety telephony certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 26 July 2019
Resolution: FCC Cert. Provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 May 2019 Resolved
Program VHF DSC function on VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 26 July 2019
Resolution: FCC cert provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2019 Resolved
A circuit breaker must be provided at the switchboard or main distribution panel for shore power connection. Install circuit breaker prior to using shore tie. 46 CFR 183.390(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2019
Resolved 17 June 2020
Resolution: Vessel removed shore tie, and does not use anymore.
Construction/Loadline › Hull › Bottom Plating
Issued 29 September 2016 Resolved
Vessel required to conduct dry-dock exam prior to carrying passengers. Dry-dock due date of 28SEP2016.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2016
Resolved 3 May 2017
Resolution: Completed credit dry-dock exam.
Lifesaving › Lifefloat › Markings
Issued 15 April 2008 Resolved
Properly place name on lifefloat.
Due 15 April 2008
Resolved 15 April 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 April 2008 Resolved
Place securing device on sewage thru-hull valve.
Due 15 April 2008
Resolved 15 April 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 April 2008 Resolved
Properly secure deck rail on port side.
Due 15 April 2008
Resolved 15 April 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 April 2008 Resolved
Properly post COI so that all pages are visible.
Due 15 April 2008
Resolved 15 April 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 April 2008 Resolved
Provide two alcohol test kits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2008
Stability › Unintentional Flooding › General
Issued 15 April 2008 Resolved
Make collision blkhd watertight.
Due 21 April 2008
Resolved 24 April 2008
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 15 April 2008 Resolved
Properly clean or replace stbd fuel vent screen.
Due 15 April 2008
Resolved 15 April 2008
Lifesaving › Lifefloat › Paddle
Issued 5 July 2007 Resolved
Provide paddles for Life Float prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2007
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 5 July 2007 Resolved
Provide water light for life-ring, life-float and buoyant apparatus NLT 12 July. Vessel is restricted to daylight operations only.
Due 12 July 2007
Resolved 16 July 2007
Engineering › Bilge Water Management System › Strainer
Issued 5 July 2007 Resolved
Properly repair strainer for mid compartment bilge suction line and install new hose clamp.
Due 12 July 2007
Resolved 16 July 2007
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 5 July 2007 Resolved
Properly repair RPM gauge.
Due 12 July 2007
Resolved 16 July 2007
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 5 July 2007 Resolved
Renew fuel cut out valve sign.
Due 12 July 2007
Resolved 16 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 July 2007 Resolved
Properly support all electrical wires every 24".
Due 12 July 2007
Resolved 16 July 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 August 2005 Resolved
Re-new vessel's main propeller shaft. Make vessel available for out of water inspection/casualty investigation by the attending marine inspector prior to operating certificated. 46 CFR 176.840. Correct to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Due 14 October 2005
Resolved 11 June 2007
Documentation › Certificates/Documents › FCC SSL
Issued 19 April 2005 Resolved
Provide FCC Marine radio Operator Permit. 47 CFR 13. Correct to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 19 May 2005
Resolved 19 May 2005
Resolution: Corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 19 April 2005 Resolved
Re-new lifering buoy. 46 CFR 180.70. Correct to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 19 May 2005
Resolved 19 May 2005
Resolution: Corrected.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 3 April 2004 Resolved
Assess propeller and cutlass bearing condition NLT 15OCT04 with USCG MI in attendance. Provide report of zinc and propeller condition to [name withheld] than 04SEP04.
Condition: Improper/Lack of Maintenance
Due 15 October 2004
Resolved 20 October 2004
Resolution: Based on digital photos submitted on 20OCT04, the vessel''s propeller remains in servicable condition. Cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 March 2004 Resolved
Service all portable fire extinguishers IAW NFPA-10 prior to carrying passengers. Correct to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 4 April 2004
Resolved 17 March 2004
Engineering › Fuel Oil Service System
Issued 4 March 2004 Resolved
Install 30 x 30 mesh screen on fuel tank vents. 46 CFR 182.450(e). Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Due 4 April 2004
Resolved 3 April 2004
Resolution: Corrected.
Electrical › Electric Generation Source (service)
Issued 4 March 2004 Resolved
Cover batteries as required by 46 CFR 183.354(b). Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Battery cover
Condition: Improper Installation
Due 4 April 2004
Resolved 3 April 2004
Resolution: Corrected.
Navigation › Piloting/Steering
Issued 4 March 2004 Resolved
Provide new inland navigation rules, 2004 Tide Tables and charts 18601, 18602 and 18603. 46 CFR 184.420/PORMS CID Policy 03-02. Correct to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Charts and publications
Condition: Improper Installation
Due 4 April 2004
Resolved 3 April 2004
Resolution: Corrected.
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 June 2003 Resolved
Light List and Coast Pilot were missing.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 June 2003
Resolution: Owner ordered pubs during the inspection and will fax the receipt when they arrive.
Navigation › Collision/Grounding Avoidance
Issued 18 June 2003 Resolved
Prove operation of masthead light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 June 2003
Resolution: Spoke to Jan Pearce via phone. She stated that her husband, O/O [name withheld] had replaced the bulb & the mast head light operated satisfactorily.
Stability › Watertight Integrity
Issued 26 April 2002 Resolved
Replace missing Deck Hatch hold down straps on engine space cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 28 May 2002
Resolution: Installed
Construction/Loadline › Penetrations › Flange Pad
Issued 26 April 2002 Resolved
Tighten scres on Handrail main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 28 May 2002
Resolution: Screws tightned
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 April 2002 Resolved
Provide proper length lanyard on ring buoy waterlight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 28 May 2002
Resolution: Corrected.
Lifesaving
Issued 3 April 2001 Resolved
REPLACE OR REPAIR LIFERING WATER LIGHT
Condition: Unknown
Due 23 April 2001
Resolved 17 May 2001
Navigation
Issued 3 April 2001 Resolved
PROVIDE NEW OR REPAIR WASTED AND CRACKED EMERGENCY STEERING TILLER
Condition: Unknown
Due 24 April 2001
Resolved 17 May 2001
Fire Fighting
Issued 11 April 2000 Resolved
PROVIDE ENGINE ROOM COMPARTMENT SMOKE TIGHT FOR FIXED FIRE FIGHTING SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 2000
Resolved 6 September 2000
Navigation
Issued 11 April 2000 Resolved
PROVIDE LIGHT FOR COMPASS 46CFR184.402
Condition: Unknown
Due 26 April 2000
Resolved 6 September 2000
Construction/Loadline
Issued 8 October 1999 Resolved
PROVIDE VALVE OR REMOVE 4 INCH THRU-HULL PENETRATION ON PORT SIDE
Condition: Unknown
Due 15 November 1999
Resolved 7 November 1999
Construction/Loadline
Issued 8 October 1999 Resolved
PROVIDE VESSEL'S HAILING PORT ON STERN
Condition: Unknown
Due 15 November 1999
Resolved 7 November 1999
Construction/Loadline
Issued 21 May 1999 Resolved
PROVIDE SEPERATE HIGH LEVEL ALARMS FOR EACH COMPARTMENT WITH HULL PENETRATION
Condition: Unknown
Due 8 June 1999
Resolved 10 September 1999
Lifesaving
Issued 21 May 1999 Resolved
PROVIDE NEW HYDROSTATIC RELEASE FOR EPIRB.
Condition: Unknown
Due 8 June 1999
Resolved 10 September 1999
Documentation
Issued 21 May 1999 Resolved
PROVIDE PROOF OF DRUG TESTING FOR CREW.
Condition: Unknown
Due 8 June 1999
Resolved 10 September 1999
Engineering
Issued 21 May 1999 Resolved
LABEL FUEL SHUT OFF VALVES.
Condition: Unknown
Due 8 June 1999
Resolved 10 September 1999
Unknown
Issued 7 April 1998 Resolved
Enroll crew in drug testing program prior to hiring.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Unknown
Issued 7 April 1998 Resolved
Train crew prior to carring passengers as per 46 CFR 185.420.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Unknown
Issued 7 April 1998 Resolved
Prove operate main engines to the local Coast Guard Inspector.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Unknown
Issued 7 April 1998 Resolved
Provide charts and publicationsas per 46 CFR 184.420.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Unknown
Issued 12 May 1997 Resolved
PROVIDE AN ADDITIONAL THREE RED HAND FLARES PRIOR TO OPERATIONS.
Condition: Unknown
Due 20 June 1997
Resolved 20 June 1997
Unknown
Issued 12 May 1997 Resolved
PROVIDE A PROPERLY REGISTERED 406 EPIRB PRIOR TO OPERATION BEYOND THREE MILES FROM SHORE.
Condition: Unknown
Due 12 May 1997
Resolved 12 May 1997
Documentation
Issued 18 April 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 April 1996
Resolved 4 June 1996
Lifesaving
Issued 9 May 1995 Resolved
PROVIDE PHOTOGRAPHIC/DOCUMENTARY EVIDENCE OF INSTALLATION OF LIFERAFT LAUNCHING INSTRUCTION PLACARD. TO BE COMPLETED NLT 19MAY95 AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Lifesaving
Issued 9 May 1995 Resolved
PROVIDE PHOTOGRAPHIC/DOCUMENTARY EVIDENCE OF POSTING OF PFD DONNING INSTRUCTIONS. TO BE COMPLETED NLT 19MAY95 AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Accommodation/Occupational Safety
Issued 9 May 1995 Resolved
PROVIDE PHOTOGRAPHIC/DOCUMENTARY EVIDENCE OF INSTALLATION OF MARPOL V - PLASTICS PLAN PLACARD. TO BE COMPLETED NLT 19MAY95 AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995

Ownership record