Records from 1985 to 2006. Most recent: inspection, 26 January 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
26 January 2006
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574028
27 October 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2226384
12 November 2003
COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1943772
18 June 2003
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1816617
21 June 2001
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1067340
9 February 2001
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1064426
6 September 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1361545
7 February 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1450401
1 December 1998
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1421582
9 January 1998
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1422964
15 October 1997
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 775414
11 June 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1111234
4 April 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1094715
17 January 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357848
3 June 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430212
17 January 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355630
20 January 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1462424
14 November 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1459135
5 January 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385176
29 November 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1159021
23 April 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828682
11 January 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1138368
2 December 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1251451
6 June 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887728
15 April 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1230237
26 December 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235713
21 December 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225682
2 October 1990
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 926281
9 January 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1212958
5 January 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1193981
16 December 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898278
22 December 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1313085
14 December 1987
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1006947
18 August 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1338277
8 September 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1028101
12 December 1985
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995827
11 December 1985
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996695
8 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287485
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 November 2004
Resolved
Secure port and stbd battery boxes.
Condition: Improper Installation
Due 18 November 2004
Resolved 18 November 2004
Resolution: Secured port and stbd battery boxes to framing.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 November 2004
Resolved
Provide chafing gear on r/w cooling flexible hose for both MDE's.
Condition: Placed in Improper Service
Due 18 November 2004
Resolved 18 November 2004
Resolution: Chafing gear placed on r/w cooling flex hose.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 November 2004
Resolved
Update First Aid kit and dispose of expired iodine swabs.
Due 18 November 2004
Resolved 23 November 2004
Resolution: Updated First Aid kit to Q spec.
Engineering › Bilge Water Management System › Not Installed
Issued 18 November 2004
Resolved
Label bilge alarms at operating station.
Due 18 November 2004
Resolved 23 November 2004
Resolution: Labeled bilge alarms at the operating station.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 November 2003
Resolved
Provide 1 additional BII portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2003
Resolved 12 November 2003
Resolution: Corrected while on board.
Lifesaving › Buoyant Apparatus
Issued 12 November 2003
Resolved
Provide a waterlight for each lifefloat. LEGACY COMPONENT DESC: Waterlight
Action required: 705 - Other - as specified
Due 12 December 2003
Resolved 12 November 2003
Resolution: Corrected while on board.
Electrical › Electrical Distribution System (service)
Issued 12 November 2003
Resolved
Provide a properly sized fuse or circuit breaker, located at the source of power, for the main 12VDC panal feeder. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2003
Resolved 18 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003
Resolved
Show that the 12VDC distribution panal circuit breakers have a minimum Ampere Interupt Capacity (AIC) of 1500 amps. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2003
Resolved 18 November 2003
Electrical › Electrical Distribution System (service)
Issued 12 November 2003
Resolved
Rewire the bilge alarm system so that the circuit protection is on the positive leg of the circuit. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2003
Resolved 18 November 2003
Construction/Loadline
Issued 18 June 2003
Resolved
Provide metallic through-hull fittings and strainers for both main engine raw water suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2004
Resolved 12 November 2003
Engineering › Bilge Water Management System
Issued 18 June 2003
Resolved
Provide a valve at the overboard connection for each submersible electric bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2004
Resolved 12 November 2003
Electrical › Electrical Distribution System (service)
Issued 18 June 2003
Resolved
Provide a single line diagram for the entire DC electrical system. The entire electrical system on the vessel has been changed or replaced and requires review before the vessel is operated.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2004
Resolved 12 November 2003
Construction/Loadline
Issued 7 February 2000
Resolved
Complete credit hull exam prior to carriage of passengers.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Construction/Loadline
Issued 9 January 1998
Resolved
Make permanent repairs to four broken welds IWO forward hatch cover.
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Documentation
Issued 4 April 1997
Resolved
Provide a Certificate of Documentation for vessel or provide evidence that vessel is less than 5 net tons. (Admeasurement must be performed by ABS orDNV).
Condition: Unknown
Due 4 April 1997
Resolved 4 April 1997
Documentation
Issued 29 November 1993
Resolved
PROVIDE CURRENT RADIO STATION LICENSE.
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Engineering
Issued 29 November 1993
Resolved
REMOVE OR REPAIR BOTH ENGINE TACHOMETERS.
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Electrical
Issued 29 November 1993
Resolved
PROVIDE TWO FUSES FOR THE BILGE PUMPS.
Condition: Unknown
Due 29 November 1993
Resolved 29 November 1993
Electrical
Issued 2 December 1991
Resolved
INSTALL A COVER FOR LIGHT IN HEAD.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Documentation
Issued 2 December 1991
Resolved
PROVIDE ON BOARD A CURRENT COPY OF THE FCC RADIOTELEPHONY CERTIFICATE AND RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 2 December 1991
Resolved 2 December 1991
Construction/Loadline
Issued 2 December 1991
Resolved
REPLACE OR REPAIR WINDOW ON PORT SIDE
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Lifesaving
Issued 2 December 1991
Resolved
INSTALL A PROPER SIZE WEAK LINK TO PAINTER FOR BUOYANT APPARATUS PRIOR TO GETTING VESSEL UNDERWAY.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Accommodation/Occupational Safety
Issued 15 April 1991
Resolved
REPAIR DISCHARGE PUMP FOR THE TOILET.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Lifesaving
Issued 15 April 1991
Resolved
PROVIDE LIFE FLOAT FOR 31 PEOPLE. VSL CANNOT OPERATE UNTIL THIS IS CORRECTED. PROVIDE A MEANS OF PREVENTING THE LIFE FLOAT FROM SLIDING OFF OF THE DECKHOUSE.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Navigation
Issued 15 April 1991
Resolved
DOUBLE NUT STEERING SYSTEM, OR PROVIDE COTTER PINS.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Fire Fighting
Issued 15 April 1991
Resolved
PROVIDE A BRACKET FOR THE B-I FIRE EXTINGUISHER LOCATED AT THE STEERING STATION OR REPAIR EXISTING BRACKET.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Documentation
Issued 15 April 1991
Resolved
PROVIDE A CURRENT RADIOTELEPHONY CERT. AND A CURRENT RADIO OPERATOR'S LICENSE.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Engineering
Issued 15 April 1991
Resolved
PROVIDE PLANS FOR INSTALLATION OF A FIXED BILGE SYSTEM. THIS IS TO BE DONENO LATER THAN 01 MAY 1991.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Construction/Loadline
Issued 15 April 1991
Resolved
REPLACE GASKET ON WATERTIGHT HATCH TO THE FOREPEAK.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Construction/Loadline
Issued 14 December 1987
Resolved
MAKE PERMANENT REPAIRS TO RUBRAIL, STARBOARD SHAFT LOG, AND TAILSHAFT.
Condition: Unknown
Due 14 December 1987
Resolved 14 December 1987
Accommodation/Occupational Safety
Issued 14 December 1987
Resolved
MAKE REPAIRS TO MSD; UNTIL REPAIRS ARE COMPLETED VESSEL IS LIMITED TO 30-MINUTE TRIP DURATION.
Condition: Unknown
Due 14 December 1987
Resolved 14 December 1987
Documentation
Issued 18 August 1987
Resolved
FCC LICENSE & STATION PERMIT EXHIBIT WRONG "CF" NUMBERS.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Construction/Loadline
Issued 18 August 1987
Resolved
TWO SECTIONS OF STBD SIDE DECK HAND RAIL SHOULD BE REPLACED.
Condition: Unknown
Due 18 August 1987
Resolved 18 August 1987
Unknown
Issued 8 September 1986
Resolved
REPLACE CRACKED WINDOWS-PORT AND STARBOARD (FORWARD).
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986