Records from 1984 to 1993. Most recent: inspection, 8 July 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
8 July 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847655
25 October 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831132
7 December 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 962447
25 November 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257087
30 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312783
3 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937403
23 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940501
12 August 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936035
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925635
1 April 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 913159
8 January 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1214972
29 October 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1226872
16 October 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223602
16 October 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1223991
31 May 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1239376
12 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230542
6 April 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1235820
12 September 1989
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1231546
8 September 1988
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338643
20 May 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1352719
13 January 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1031186
15 September 1987
Damage Survey · COI Inspection · Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333558
3 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020627
25 September 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005043
30 November 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986492
13 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288384
2 September 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 976839
2 September 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1282520
Fire Fighting
Issued 25 October 1992
Resolved
PROVIDE APPROVED 3 CELL BATTERY TYPE FLASHLIGHTS AND LIFELINES FOR EACH FIREMAN OUTFIT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
SERVICE AND MAKE OPERABLE OR REPLACE ONE PORTABLE O2 LEL METER. ABOVE ITEMSMAY BE CLEARED BY SUBMITTING SIGNED OIM STATEMENT OF COMPLIANCE TO [name withheld].
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
CROP AND RENEW AS ORIGINAL APPROX 5FT BY 8FT SECTION TO NRZ PRELOAD TANK_x001C_ OUTBOARD OF TURN OF BILGE. REPAIRS TO BE COMPLETED NEXT SCHEDULE DRYDOCK APRIL 92.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
HYDROSTATICALLY TEST ALL OUTDATED CO2 CYLINDERS AND FLEX LOOPS IN ENGINE ROOM AND PROVIDE COPY OF SERVICING REPORT FROM APPROVED DOT FACILITY TO [name withheld]. _x001C_ _x001C_
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH COPY OF APPROVAL DATE AND PORT OF APPROVAL FOR OPERATING MANUAL, 33 CFR 109.121
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
CROP AND RENEW AS ORIGINAL APPROX 5FT BY 8FT SECTION TO NRZ PRELOAD TANK OUTBOARD OF TURN OF BILGE. REPAIRS TO BE COMPLETED NEXT SCHEDULE DRYDOCK APRIL 92.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Documentation
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH COPY OF APPROVAL DATE AND PORT OF APPROVAL FOR CLASS AND LOCATION PLAN, 46 CFR 110.25-1-(I)
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Documentation
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH COPY OF WIRE ROPE SAFETY CERTIFICATE FOR DAVIT LAUNCHED LIFE RAFT SYSTEM AND LIFEBOAT DAVIT FALLS
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Lifesaving
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH COPY OF CERTIFICATES FOR FOUR B.F. GOODRICH LIFERAFTS BEING SERVICED AT D.O.T. APPROVED FACILITY SEP 91.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Fire Fighting
Issued 12 August 1991
Resolved
PERMANTENTLY INSTALL SIX SMOKE DETECTORS IN ROOMS 1,2,9,17,18,AND 25.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Lifesaving
Issued 12 August 1991
Resolved
RENEW IN LIKE KIND AND QUALITY AS ORIGINAL LIFEBOAT EQUIPMENT TO PORT AND STBD LIFEBOAT CAPSULES, 46 CFR 94.20-10 (A). "SPECIAL NOTE" MAKE AVAILABLE FOR STANDBY USE "OFF SHORE SUPPLY VSL" 24 HOURS A DAY NO MORE THAN 1000 YARDS OFF RIG'S POSITION UNTIL RECEIPT OF LIFEBOAT EQUIP APPROX 26 AUG 91.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Lifesaving
Issued 12 August 1991
Resolved
PROVIDE REQUIRED ANNUAL SERVICING FOR HYDROSTATIC RELEASE UNITS ON LIFERAFTS NR 1A, 1B, 2A AND 2B.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Deck/Cargo
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH COPY OF 4 YR CRANE INSPECTION OF SEP 91 CONDUCTED BY ABS.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Fire Fighting
Issued 12 August 1991
Resolved
PROVIDE HYDROSTATIC TESTING OF PAINT LOCKER FIXED EXTINGUISHING 150-C02 SYSTEM.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Engineering
Issued 12 August 1991
Resolved
DEMONSTRATE PROPER OPERATION OF NR2 GENERATOR'S OVERSPEED TRIP.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Engineering
Issued 12 August 1991
Resolved
DEMONSTRATE PROPER OPERATION OF NR1 AND NR2 GENERATOR'S HIGH TEMP ALARMS.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Deck/Cargo
Issued 12 August 1991
Resolved
PERMANTENTLY INSTALL VISUAL FLASHING LIGHT FOR LOSS OF PURGE, TO BE READILYSEEN IN SHALE SHAKER AREA.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Fire Fighting
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH CURRENT COPY OF FOAM ANALYSIS REPORT FOR HELO DECK EXTINGUISHING SYSTEM.
Condition: Unknown
Due 10 October 1991
Resolved 10 October 1991
Fire Fighting
Issued 12 August 1991
Resolved
PROVIDE [name withheld] WITH COPY OF REQUIRED ANNUAL SERVICING FOR ALL PORTABLE, SEMI-PORTABLE AND FIXED EXTINGUISHING SYSTEMS BEING SERVICED BY D.O.T. APPROVED FACILITY SEP 91.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Lifesaving
Issued 12 August 1991
Resolved
PROVIDE HYDROSTATIC TESTING OF PORT AND STBD LIFEBOAT CAPSULES BREATHING AIR SYSTEM BOTTLES, AND RENEW IN LIKE KIND AND QUALITY AS ORIGINAL FLEX HOSES FOR BOTTLES AT A D.O.T. APPROVED FACILITY.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Engineering
Issued 12 August 1991
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY GENERATOR OVER SPEED TRIP.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Unknown
Issued 29 October 1990
Resolved
PROVIDE REVISIONS TO OPERATING MANUAL PER PATMS LTR DATED 27 NOV 90.
Condition: Unknown
Due 29 October 1990
Resolved 29 October 1990
Unknown
Issued 16 October 1990
Resolved
REPAIR EXTERIOR DOORS TO ACCOMMODATIONS AND IN THE STAIRWELL TO BE SELF-_x001C_ CLOSING AND LATCH.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
REMOVE DEADEND WIRING IN THE LAUNDRY BEHIND THE WASHER AND DRYER, ALSO ON THE RAILING OF THE HELIPORT.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
PROVIDE TO MSO PORT ARTHUR RESULTS OF FOAM ANALYSIS.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
PLUG OPENINGS IN PANELBOARDS IN STAIRWELL.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
PROVIDE COVERS FOR DAVIT LAUNCHED LIFERAFT WIRE FALL DRUMS.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
REPAIR PORT OBSTRUCTION LIGHT.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
REPLACE EMERGENCY LIGHT IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
DRAIN AND CLEAN THE BILGES OF BOTH LIFEBOATS
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
REPAIR AND TEST AUTOMATIC LOAD PICK-UP OF EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Unknown
Issued 16 October 1990
Resolved
PROVIDE A NON-SKID SURFACE FOR THE HELODECK.
Condition: Unknown
Due 16 October 1990
Resolved 16 October 1990
Construction/Loadline
Issued 6 April 1990
Resolved
MAKE CANS AND HIGH STRESS AREAS OF LEGS AVAILABLE FOR EXAMINATION.
Condition: Unknown
Due 6 April 1990
Resolved 6 April 1990
Electrical
Issued 12 September 1989
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS, OVERSPEED TRIPS LOW LUBE OIL TRIPS OF SLIP SERVICE & EMERGENCY GENERATOR.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Documentation
Issued 12 September 1989
Resolved
PROVIDE AN APPROVED COPY OF VESSEL CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF DRILL FLOOR PURGE ALARM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF H2S ALARM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVIDE BLANKS WERE MISSING IN CIRCUIT BREAKER PANEL EL-30 LOCATED IN SCR ROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Unknown
Issued 15 September 1987
Resolved
CONDUCT THE FOLLOWING TEST TO THE HELO FUELING SYSTEM: A. ANNUAL PRV, AND VRV B. 30 MONTH INTERNAL EXAMINATION C. 60 MONTH HYDRO.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
RENEW FIRE DAMPER CABLE FOR PAINT LOCKER.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PLACE A NO SMOKING SIGN ON BATTERY ROOM DOOR.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF FIRE PUMPS.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
BLANK OPENING IN CIRCUIT BREAKER PANEL LOCATED IN CONTROL ROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
REPAIR SWITCH ON FOAM PUMP LOCATED ON TOP OF HOUSE.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
FREE UP BATTERY ROOM SUPPLY VENT FIRE DAMPER.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR LOW LUBE OIL PRESSURE TRIP AND HIGH WATER TEMPERATURE TRIP.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
REPLACE BATTERIES IN EPIRB.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM SYSTEM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Documentation
Issued 15 September 1987
Resolved
PROVIDE CURRENT LOADLINE CERTIFICATE.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
RENEW CABLES ON BOTH SURVIVAL CAPSULE DAVITS OR PROVIDE PROOF OF DATE CABLES WERE LAST CHANGED AND END FOR ENDED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF EMERGENCY RADIO.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
RENEW CABLES ON BOTH INFLATABLE LIFERAFT DAVITS ARMS OR PROVIDE PROOF WHEN CABLES LAST CHANGED OR END FOR ENDED.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
BLANK OPENING IN 120 VOLT CIRCUIT BREAKER PANEL LOCATED IN RADIOROOM.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
RESET EMERGENCY GENERATOR ROOM SOUND POWERED PHONE DIAL.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
REPLACE BROKEN GLASS IN EMERGENCY VENT STOP BOX NO. ES15, LOCATED MAIN DECKSTARBOARD SIDE AFT.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Construction/Loadline
Issued 15 September 1987
Resolved
MAKE REPAIRS AS NEEDED TO SAFETY NETTING ON STARBOARD SIDE OF HELO DECK.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 15 September 1987
Resolved
REPAIR OR REPLACE SURVIVAL CAPSULE NUMBER 1.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF NO. 2 GENERATOR'S ALARM LIGHT.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
PROVE PROPER OPERATION OF NO. 3 GENERATOR LOCAL ALARM, BOTH AUDIO AND VISUAL.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Engineering
Issued 15 September 1987
Resolved
RENEW BOTH RELIEF VALVES ON BOTH RIG AIR COMPRESSORS WITH 150 PSI VALVES.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Fire Fighting
Issued 15 September 1987
Resolved
PROVIDE EXPLOSION- PROOF FITTINGS FOR BARKSDALE SWITCH AND SIREN LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
REMOVE AIR CONDITIONER LOCATED IN DRILLERS OFFICE ON DRILL FLOOR OR PROVE UNIT TO BE EXPLOSIVE PROOF.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Electrical
Issued 15 September 1987
Resolved
CLOSE OPENING IN ELECTRICAL FIXTURES LOCATED ABOVE DRILL FLOOR TELEPHONE.
Condition: Unknown
Due 15 September 1987
Resolved 15 September 1987
Lifesaving
Issued 2 September 1984
Resolved
REPLACE MISSING BUOYANT ROCKET FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 2 September 1984
Resolved 2 September 1984
Lifesaving
Issued 2 September 1984
Resolved
REPLACE MISSING BUOYANT ROCKET FOR LINE THROWING APPLIANCE.
Condition: Unknown
Due 2 September 1984
Resolved 2 September 1984