MAURY USCG vessel records Sign in
← All vessels

MEREKSEN

MEREKSEN is a 1981 tank ship. The Coast Guard has recorded 6 inspections since 1984, most recently in March 1986, along with 18 deficiencies.

Records from 1984 to 1986. Most recent: inspection, 18 March 1986.

Built
1981
Last inspected
18 March 1986
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8122983 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ALGERIA
—
Maury page id
psix-54694

Inspections, by type

…with no type recorded6
Years with a record 3 calendar years (1984–1986)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3438 - Regulatory (Subpart C or D), Gross Ton
1955 - Regulatory (Subpart C or D), Net Ton
6150 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 6

18 March 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 307659
18 March 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997160
3 December 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 305776
30 November 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 537592
1 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 298205
1 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 975472

Deficiency record · 18

Navigation
Issued 18 March 1986 Resolved
REQUIRED PREARRIVAL TESTS WERE NOT CONDUCTED OR LOGGED PRIOR TO ENTERING THE PORT OF NEW YORK.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Fire Fighting
Issued 18 March 1986 Resolved
PERSONNEL EMERGENCY AND SAFETY EQUIPMENT INADEQUATE. ALL FIRE LOCKERS WERE EXAMINED AND REQUIRED EQUIPMENT WAS NOT PRESENT OR WAS NOT SERVICEABLE.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 March 1986 Resolved
SAFETY EQUIPMENT LOCKERS NOT MARKED AS REQUIRED BY 46 CFR 153.215(D).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 March 1986 Resolved
VENTING SYSTEM BYPASS VALVES INOPERATIVE.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 March 1986 Resolved
NO RED FLAG DISPLAYED DURING TRANSFER OPERATIONS.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Unknown
Issued 18 March 1986 Resolved
VESSEL'S PERSON IN CHARGE WAS UNABLE TO COMMUNICATE WITH THE DOCK PERSON INCHARGE IN ENGLISH.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Deck/Cargo
Issued 18 March 1986 Resolved
EMERGENCY SHUTDOWN STATIONS WERE NOT MARKED.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 18 March 1986 Resolved
NO HOISTING EQUIPMENT FOR AN UNCONSCIOUS PERSON IN THE BELOW WEATHER DECK PUMPROOM WAS PRESENT.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 18 March 1986 Resolved
NO PROTECTIVE CLOTHING. VSL DID NOT HAVE THE REQUIRED RUBBER APRONS OR SPLASH SUITS ONBOARD.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 March 1986 Resolved
VESSEL HAD NO WARNING SIGNS POSTED, NOR ON BOARD.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 March 1986 Resolved
CHARTS 12326, 12327, AND 12333 WERE NOT CORRECTED UP TO DATE WITH THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Navigation
Issued 18 March 1986 Resolved
U.S. COAST GUARD LIGHT LIST NOT CORRECTED UP TO DATE WITH THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Fire Fighting
Issued 18 March 1986 Resolved
THREE FIRE DAMPERS FOR CARGO PUMP ROOMS INOPERABLE.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Deck/Cargo
Issued 18 March 1986 Resolved
CARGO HOSES NOT SUPPORTED BY SHIPS TACKLE.
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Deck/Cargo
Issued 18 March 1986 Resolved
P/V VALVE VENT PIPING FOR NR 4 CARGO TANK IS WASTED.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 March 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 March 1986
Resolved 18 March 1986
Documentation
Issued 18 March 1986 Resolved
CODES OF FEDERAL REGULATIONS REQUIRED NOT ON BOARD
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 1 October 1984 Resolved
33 CFR 155.430 STANDARD DISCHARGE CONNECTION NOT ONBOARD
Condition: Unknown
Due 1 October 1984
Resolved 1 October 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.