MAURY USCG vessel records Sign in
← All vessels

STAFFORDSHIRE

STAFFORDSHIRE is a 1977 tank ship. The Coast Guard has recorded 20 inspections since 1986, most recently in September 1996, along with 11 deficiencies.

Records from 1986 to 1996. Most recent: inspection, 2 September 1996.

Built
1977
Last inspected
2 September 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7417642 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED KINGDOM
—
Maury page id
psix-54700

Inspections, by type

…with no type recorded9
Years with a record 8 calendar years (1986–1996)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it45311 - Regulatory (Subpart C or D), Gross Ton
32072 - Regulatory (Subpart C or D), Net Ton
56188 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

2 September 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394850
2 September 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 936680
4 April 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1166549
22 October 1993 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 846589
1 October 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1156479
5 September 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 933878
28 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332264
28 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332765
28 August 1989 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044047
10 July 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 508088
20 August 1988 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039896
20 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 521758
26 August 1987 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1030631
6 July 1987 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1322719
30 May 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1027558
30 May 1987 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1031629
8 August 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 310641
8 August 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1307301
3 July 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1301662
1 July 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309877

Deficiency record · 11

Construction/Loadline
Issued 2 September 1996 Resolved
Make gas-tight the outer door to cargo control room._x001C_ Provide satisfactory flag state report to US Coast Guard of the tightness to the outer and inner doors as per CG 3.6.1.
Condition: Unknown
Due 15 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1996 Resolved
Install audible and visual alarms on both sides of air lock, as per CG3.6.3. Provide flag state report to U.S. Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1996 Resolved
Demonstrate proper operation if IG system of the following alarms/shutdown;flame failure, high oxygen & high temperature alarms. Provide class surveyreport to US Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 2 September 1996 Resolved
Make permanent repairs to holed deck water spray system located forward of cargo control room stbdside, port bridge wing, under cargo deckhouse, as per CG 11.3. Provide class survey report to US Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1996 Resolved
Demonstrate proper operation of high liquid level alarm that activate shut-off to flow of cargo as per CG13.3.1. Provide satisfactory class survey report to U S Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 1 October 1993 Resolved
HYDROSTATICALLY TEST THE CARGO TRANSFER HOSES TO 1 1/2 MAWP PRIOR TO USE INU. S. WATERS.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Deck/Cargo
Issued 1 October 1993 Resolved
PRIOR TO CARGO OPERATIONS IN U. S. WATERS PROVE PROPER OPERATION OF THE IGSSYSTEM TO ATTENDING U. S. CAOST GUARD INSPECTOR.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Deck/Cargo
Issued 28 August 1989 Resolved
PROVE PROPER OPERATON OF QUICK CLOSING MANIFOLD VALVES, UPON RETURN NEXT U.S.PORT.
Condition: Unknown
Due 28 August 1989
Resolved 28 August 1989
Unknown
Issued 6 July 1987 Resolved
ZERO & CALIBRATE IGS OXYGEN ANALYZER, & RETEST HIGH OXYGEN CONTENT ALARM & VALVE CHANGEOVER.
Condition: Unknown
Due 6 July 1987
Resolved 6 July 1987
Deck/Cargo
Issued 30 May 1987 Resolved
TEST IGS IN THE PRESENCE OF A USCG INSPECTOR AT NEXT U.S. PORT.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Deck/Cargo
Issued 1 July 1986 Resolved
VESSEL WAS UNABLE TO ENERGIZE THE INERT GAS SYSTEM WITHOUT A POSSIBILITY OFACCIDENTAL RELEASE OF FUEL OIL INTO THE WATER. UPON RETURN TO THE U.S. THEIGS SHOULD BE IN OPERATION TO ALLOW FOR NECESSARY TESTS AND EXAMINATIONS ASREQUIRED BY USCG PERSONNEL.
Condition: Unknown
Due 1 July 1986
Resolved 1 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.