Records from 1986 to 1996. Most recent: inspection, 2 September 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
2 September 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394850
2 September 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 936680
4 April 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1166549
22 October 1993
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 846589
1 October 1993
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1156479
5 September 1992
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 933878
28 August 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332264
28 August 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332765
28 August 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1044047
10 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 508088
20 August 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1039896
20 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 521758
26 August 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1030631
6 July 1987
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1322719
30 May 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1027558
30 May 1987
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1031629
8 August 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 310641
8 August 1986
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1307301
3 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1301662
1 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309877
Construction/Loadline
Issued 2 September 1996
Resolved
Make gas-tight the outer door to cargo control room._x001C_ Provide satisfactory flag state report to US Coast Guard of the tightness to the outer and inner doors as per CG 3.6.1.
Condition: Unknown
Due 15 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1996
Resolved
Install audible and visual alarms on both sides of air lock, as per CG3.6.3. Provide flag state report to U.S. Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1996
Resolved
Demonstrate proper operation if IG system of the following alarms/shutdown;flame failure, high oxygen & high temperature alarms. Provide class surveyreport to US Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 2 September 1996
Resolved
Make permanent repairs to holed deck water spray system located forward of cargo control room stbdside, port bridge wing, under cargo deckhouse, as per CG 11.3. Provide class survey report to US Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 2 September 1996
Resolved
Demonstrate proper operation of high liquid level alarm that activate shut-off to flow of cargo as per CG13.3.1. Provide satisfactory class survey report to U S Coast Guard.
Condition: Unknown
Due 2 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 1 October 1993
Resolved
HYDROSTATICALLY TEST THE CARGO TRANSFER HOSES TO 1 1/2 MAWP PRIOR TO USE INU. S. WATERS.
Condition: Unknown
Due 1 October 1993
Resolved 1 October 1993
Deck/Cargo
Issued 1 October 1993
Resolved
PRIOR TO CARGO OPERATIONS IN U. S. WATERS PROVE PROPER OPERATION OF THE IGSSYSTEM TO ATTENDING U. S. CAOST GUARD INSPECTOR.
Condition: Unknown
Due 19 October 1993
Resolved 19 October 1993
Deck/Cargo
Issued 28 August 1989
Resolved
PROVE PROPER OPERATON OF QUICK CLOSING MANIFOLD VALVES, UPON RETURN NEXT U.S.PORT.
Condition: Unknown
Due 28 August 1989
Resolved 28 August 1989
Unknown
Issued 6 July 1987
Resolved
ZERO & CALIBRATE IGS OXYGEN ANALYZER, & RETEST HIGH OXYGEN CONTENT ALARM & VALVE CHANGEOVER.
Condition: Unknown
Due 6 July 1987
Resolved 6 July 1987
Deck/Cargo
Issued 30 May 1987
Resolved
TEST IGS IN THE PRESENCE OF A USCG INSPECTOR AT NEXT U.S. PORT.
Condition: Unknown
Due 30 May 1987
Resolved 30 May 1987
Deck/Cargo
Issued 1 July 1986
Resolved
VESSEL WAS UNABLE TO ENERGIZE THE INERT GAS SYSTEM WITHOUT A POSSIBILITY OFACCIDENTAL RELEASE OF FUEL OIL INTO THE WATER. UPON RETURN TO THE U.S. THEIGS SHOULD BE IN OPERATION TO ALLOW FOR NECESSARY TESTS AND EXAMINATIONS ASREQUIRED BY USCG PERSONNEL.
Condition: Unknown
Due 1 July 1986
Resolved 1 July 1986