MAURY USCG vessel records Sign in
← All vessels

MARINE PRINCESS

MARINE PRINCESS is a 1967 freight ship. The Coast Guard has recorded 49 inspections since 1983, most recently in January 1995, along with 104 deficiencies.

Records from 1983 to 1995. Most recent: inspection, 23 January 1995.

Built
1967
Last inspected
23 January 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6716742 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
367093000 (licence lapsed)
Maury page id
psix-54702

Inspections, by type

…with no type recorded23
Years with a record 13 calendar years (1983–1995)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it26059 - Regulatory (Subpart C or D), Gross Ton
19516 - Regulatory (Subpart C or D), Net Ton
52565 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WNLHMMSI 367093000 · cancelled · compulsorily equipped · granted 5 November 1996, cancelled 14 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 49

23 January 1995 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1355100
10 January 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 165504
12 September 1994 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 370364
17 June 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 163883
17 June 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 187355
29 April 1994 Damage Survey · Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1356620
25 April 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 651700
21 April 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 32409
21 April 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 164741
10 November 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358230
10 November 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409041
2 April 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1433994
31 March 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1144723
6 January 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143392
29 December 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141823
2 December 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1141207
29 January 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 963021
4 December 1991 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254491
7 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230312
24 April 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904989
14 February 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997618
11 February 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233316
26 November 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916616
27 May 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235700
19 April 1990 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 916743
31 May 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1342881
23 May 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 899205
2 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 438643
2 May 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 896321
31 March 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341928
3 January 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1039994
16 September 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1195989
13 May 1988 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1041557
29 April 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1037144
11 June 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 436371
17 March 1987 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1021500
4 March 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1021361
14 September 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 466596
21 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988634
25 March 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 996701
20 March 1986 Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1293608
16 January 1986 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 995638
25 October 1985 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1295081
11 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 985950
11 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 982475
19 January 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1283608
15 January 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 299548
8 September 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 467550
18 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969392

Deficiency record · 104

Construction/Loadline
Issued 29 April 1994 Resolved
DETERMINE SOURCE OF OIL POLLUTION, STBD SIDE AFT. SUBMIT REPAIR PROPOSAL TO MSO JACKSONVILLE O.C.M.I. REPAIR TO BE COMPLETED PRIOR TO MOVING VESSEL.
Condition: Unknown
Due 30 April 1994
Resolved 30 April 1994
Engineering
Issued 10 November 1993 Resolved
PROPERLY REPAIR BRINE PUMP SUCTION LINE FROM EVAPORATOR. _x001C_ REPAIR/REPLACE AT NEXT DRYDOCKING.
Condition: Unknown
Due 31 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 10 November 1993 Resolved
PROVE PROPER OPERATION OF #1 SHIP SERVICE GENERATOR REVERSE POWER RELAY ANDMAIN CIRCUIT BREAKER MANUAL TRIP.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Engineering
Issued 10 November 1993 Resolved
REPAIR EOT ALARM AND GENERAL ALARM BELL IN PURIFIER ROOM.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Navigation
Issued 10 November 1993 Resolved
RENEW LIGHT BULBS/LENSES/LABELS THAT ARE MISSING ON STEERING CONTROLLER ANDGENERAL ALARM PANEL.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Electrical
Issued 10 November 1993 Resolved
INSTALL HIGH VOLTAGE SIGNS ON FRONT OF AND ON DOORS LEADING TO THE BACK OF THE MAIN SWITCHBOARD.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Accommodation/Occupational Safety
Issued 10 November 1993 Resolved
INSTALL PROPER 100PSI/210 DEGREE PRESSURE/TEMPERTURE RELIEF VALVES ON HOT WATER HEATER.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Lifesaving
Issued 10 November 1993 Resolved
INSTALL PROPER GUARDS AND GLASS TUBES ON GENERAL COOLING WATER TANK AND SANITARY WATER TANK.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Electrical
Issued 10 November 1993 Resolved
MAKE PERMANENT REPAIRS TO DROP LIGHT RECEPTACLE ON CARGO HOLD NUMBER FOUT STARBOARD SIDE.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Engineering
Issued 10 November 1993 Resolved
PROVIDE PROPER CONTAINMENT FOR FUEL OIL SUPPLY MANIFOLD BOTH PORT AND STARBOARD SIDE.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 10 November 1993 Resolved
MAKE PERMANENT REPAIRS TO PORT-AFT MAIN DECK WASTED WINCH GEAR GUARD.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 10 November 1993 Resolved
REPLACE HYDRAULIC LINE ON CARGO HOLD NUMBER 5 HATCH RAM, STARBOARD SIDE.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 10 November 1993 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN #1 BOTTOM WING BALLAST TANK PORT SIDE, LOCATED AT FRAMES 231-234 AND LOGS 4-6. INSERT 4.5" BY 5.5" BY 0.5" AND TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 10 December 1993
Resolved 13 December 1993
Engineering
Issued 2 December 1992 Resolved
MAKE PERMANENT REPAIRS TO TO ALL FUEL OIL LINES HAVING TEMPORARY REPAIRS_x001C_ (REDHAND); SPECIFICALLY GOOSE NECK VENTS ON DECK.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Engineering
Issued 2 December 1992 Resolved
TEST MAIN ENGINE LOW LUBE OIL PRESSURE SLOW DOWN ALARM AND STANDBY LUBE OILPUMP OPERATION AND SUBMIT RESULTS TO [name withheld].
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Construction/Loadline
Issued 2 December 1992 Resolved
MAKE PERMANMENT REPAIRS TO HOLED HATCH COAMINGS (AREAS COVERED WITH RED HAND). ALL INSERTS SHALL BE A MINIMUM OF 18"X18" WITH RADIUS CORNERS.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Engineering
Issued 2 December 1992 Resolved
COMPLY WITH MINIMUM ABS REQUIREMENTS FOR MAIN ENGINE VISUAL AND AUDIBLE ALARM/SHUTDOWN SYSTEM. IF THIS REQUIRES A NEW SYSTEM IT SHALL BE SUBMITTED TO THE U.S. COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL. DEMONSTRATE PROPER OPERATION OF SAME TO THE ATTENDING C.G. MARINE INSPECTO
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Electrical
Issued 2 December 1992 Resolved
REPAIR OR RENEW K W METER ON MAIN SWTTCHBOARD FOR #3 SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 2 January 1993
Resolved 9 December 1992
Lifesaving
Issued 2 December 1992 Resolved
CONDUCT WEIGHT TESTS OF #1&2 LIFEBOATS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 2 February 1993
Resolved 9 December 1992
Engineering
Issued 2 December 1992 Resolved
EITHER HYDROSTATICALLY TEST AUXILLARY BOILER AND ECONOMIZER BOILER OR SUBMIT EXTENSION LETTER IAW COMDT POLICY LETTER 17-90 DATED 25JUL90 TO OCMINEW ORLEANS. HYDRO TEST ARE TO BE WITNESSED BY A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 January 1993
Resolved 9 December 1992
Engineering
Issued 2 December 1992 Resolved
DO NOT OPERATE EITHER AUXILLARY BOILER EXCEPT IN MANUAL ATTENDED MODE UNTILAUTOMATIC MODE HAS BEEN SATISFACTORILY DEMONSTRATED TO A U.S. COAST GUARD MARINE INSPECTOR. IF ALTERATIONS ARE MADE TO AUTOMATION SYSTEM SUBMIT DRAWINGS TO U.S. COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Engineering
Issued 2 December 1992 Resolved
REPAIR OR REMOVE INSTALLED MAIN ENGINE MONITORING SYSTEM AND DEMONSTRATE PROPER OPERATION OF SAME TO THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Engineering
Issued 2 December 1992 Resolved
INSTALL LAGGING OR BLANKETS ON EMERGENCY GENERATOR ENGINE EXHAUST.
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Engineering
Issued 2 December 1992 Resolved
TEST ECONOMIZER SAFETY VALVES AT SEA, RECORD RESULTS IN MACHINERY LOG AND SUBMIT RESULTS TO [name withheld].
Condition: Unknown
Due 2 January 1993
Resolved 3 December 1992
Construction/Loadline
Issued 2 December 1992 Resolved
MAKE PERMAENT REPAIRS TO TEMPORARY REPAIRS MADE IN WAY OF #2&3 CARGO HOLDS.PROPOSAL SHALL BE SUBMITTED TO THE U.S. COAST GUARD PRIOR TO REPAIRS.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Fire Fighting
Issued 4 December 1991 Resolved
PROVE THE PROPER AUTOMATIC OPERATION OF THE FIXED CO2 SYSTEM FOR THE PORT PAINT LOCKER. THIS PAINT LOCKER IS NOT TO BE USED FOR PAINT OR FLAMABLE_x001C_ STORAGE UNTIL THIS ITEM IS CORRECTED (STBD PAINT LOCKER IS AVAILABLE).
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Fire Fighting
Issued 4 December 1991 Resolved
PROVIDE A FULLY OPERATIONAL CO2 BOTTLE TO REPLACE THE FAULTY ONE FOR THE ENGINE ROOM FIXED CO2 SYSTEM (ONE OF THE 94 BOTTLES COULD NOT BE FILLED _x001C_ OR CONNECTED DUE TO MISSING VALVE PARTS).
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Engineering
Issued 24 April 1991 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR AND 15 PPM MONITOR.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Engineering
Issued 24 April 1991 Resolved
PROVE PROPER OPERATION OF THE FOLLOWING MAIN ENGINE SAFETY DEVICES: OVERSPEED SAFETY DEVICE; LOSS OF JACJET WATER PRESSURE; LOSS OF PISTON COOLING PRESSURE; LOSS OF LUBE OIL PRESSURE WHILE VESSEL IS UNDERWAY; AND LOG RESULTS IN THE VESSEL'S OPERATING LOG WITH A COPY TO MSO NEW ORLEANS.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Engineering
Issued 24 April 1991 Resolved
PROVE PROPER OPERATION OF AUTOMATION FOR AUXILIARY AND WASTE HEAT BOILERS. UNTIL THIS REQUIREMENTIS COMPLETED, BOTH BOILERS ARE TO BE CONSTANTLY ATTENDED WHILE FIRING WITH OIL.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Engineering
Issued 19 April 1990 Resolved
WITNESS TEST OF CABLE PULLS AS FOLLOWS: FUEL OIL DEEP TANK, DIESEL OIL SERVICE TO GENERATOR AND SHUT OFF TO FUEL OIL BUNKER TANK HIGH SUCTION PORT
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
REPAIR AND PROVE OPERATION OF HEAVY OIL BOOSTER PUMP CONTROLLER AND REMOTE TRIP AND HEAVY OIL PRUIFIER NO.2 REMOTE TRIP.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
CORRECTLY LABEL REMOTE TRIPS FOR HEAVY OIL PURIFIERS NO.1 AND 3, LABEL CABLE PULL SHUTOFFS FOR DIESEL OIL SERVICE TO MAIN ENGINE VALVE AND DIESEL OIL SERVICE TO GENERATOR.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Electrical
Issued 19 April 1990 Resolved
SECURE MULTIPLE CABLE RUN ON SIDE OF DECKHOUSE BY FIRE STATION NO.20.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Electrical
Issued 19 April 1990 Resolved
RENEW ELECTRICAL CONDUCTORS AT FUSE BLOCK MAIN SWITCHBOARD, FUSE DB"F AND DB"G".
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
WITNESS SATISFACTORY OPERATION OF OIL WATER SEPARATOR MONITOR & AUTOMATIC SHUT DOWN VALVES & POSTED OIL POLLUTION PLACARRDS AT SFIN VALVES.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
PRIOR TO OIL FIRED OPERATION OF EXHAUST GAS BOILER PROVE OPERATION OF SAFETY CUT-OFFS IN PRESENCE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
PRIOR TO OPERATION OF AUX OIL FIRED BOILER SET & SEAL SAFETY VALVES AND PROVE OPERATION OF SAFETY CUT OFFS IN PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Lifesaving
Issued 19 April 1990 Resolved
RENEW ONE NON-BUOYANT ROCKET FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
INSTALL CORRECT HOSES ON HEAVY OIL PURIFIERS.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 19 April 1990 Resolved
INSTALL GUARDS ON PUMP COUPLINGS, PORT & STARBOARD STEERING PUMPS.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 19 April 1990 Resolved
REPAIR HEAT EXCHANGER HEAD ON LUBE OIL COOLER.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Engineering
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF AUXILIARY OIL-FIRED BOILER, AND OIL-FIRED SECTIONOF WASTEHEAT BOILER AUTOMATIC CONTROLS IAW 46 CFR 63.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF ALL PRESSURE VESSEL RELIEF VALVES UNDER PRESSURE IAW 46 CFR 61.10-5(I).
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Fire Fighting
Issued 2 May 1989 Resolved
INSTALL FIRE CONTROL PLAN AT GANGWAY.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Fire Fighting
Issued 2 May 1989 Resolved
MODIFY THE SHIP'S FIRE CONTROL PLAN TO SHOW THE LOCATION OF THE VESSEL'S INTERNATIONAL SHORE CONNECTION IN ITS STORAGE LOCATION.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Fire Fighting
Issued 2 May 1989 Resolved
IDENTIFY THE LOCATION AND MOUNT THE INTERNATIONAL SHORE CONNECTION IN ITS STORAGE LOCATION.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
CONDUCT WEIGHT TEST OF THE STARBOARD LIFEBOAT.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
REMOVE, OR PROPERLY DEAD-END IN A JUNCTION BOX STRAY WIRING IN THE FOLLOWING LOCATIONS: (1) IN PURIFIER RM NEXT TO #1 HFO PURIFIER; (2) IN WAYOF PURIFIER ROOM ENTRANCE; (3) IN MACHINE SHOP OVER OVC WELDER, WHERE MARKED "LIVE 220V."
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF #3 SSDG REVERSE POWER RELAY, AND MANUAL BREAKER TRIP BUTTON.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF H.O. SERVICE TO MAIN ENGINE - LOWER SUCTION REMOTELY OPERATED QUICK-CLOSING VALVE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF H.F.O. PURIFIER #2 REMOTE SHUTDOWN.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Navigation
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF STEERING GEAR GYRO REPEATER SUCH THAT IT AGREES WITH THE ONE IN THE WHEELHOUSE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Electrical
Issued 2 May 1989 Resolved
PROVIDE A NON-CONDUCTIVE MAT IN FRONT OF THE EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Fire Fighting
Issued 2 May 1989 Resolved
PROPERLY LABEL LOWER ENGINEROOM CO2 SIREN IAW 46 CFR 97.37-9.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF THE FOLLOWING MAIN ENGINE TRIPS: (1) LOSS OF JACKET WATER PRESSURE; (2) LOSS OF PISTON COOLING PRESSURE; (3) LOSS OF LUBE OIL PRESSURE; WHILE VESSEL IS UNDERWAY, AND LOG RESULTS IN THE VESSEL'S OPERATING LOG, WITH A COPY TO MSO LA/LB.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
CONDUCT FIRE AND BOAT DRILLS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF BOTH PORT AND STARBOARD LIFEBOAT DAVIT LIMIT SWITCHES.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
PROVE PROPER OPERATION OF AUXILIARY OIL FIRED, AND WASTEHEAT BOILER SAFETY VALVES, INCLUDING EASING GEAR IAW 46 CFR 61.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Engineering
Issued 2 May 1989 Resolved
REPAIR OR REPLACE THE FOLLOWING VALVES WHERE LEAKING ON THE WASTEHEAT BLR: UPPER GAGE GLASS VALVE; STEAM PRESSURE GAGE ROOT VALVE.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Lifesaving
Issued 2 May 1989 Resolved
REPLACE BOTH PORT AND STARBOARD LIFEBOAT WINCHES WITH SINGLE-LAY WINCH DRUMS.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
PROVIDE PERMANENT STOWAGE FOR ALL OXY-ACETYLENE WELDING BOTTLES ON VESSEL.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
REPAIR DAMPENER BRACKET 04-33-2.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Electrical
Issued 29 April 1988 Resolved
REPAIR 3 PHASE WIRING FROM SUPPLY TO POWER CONTROL BOX FRO STBD LIFE BOAT.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
CROP AND RENEW NATURAL VENT FOR ROPE STOWAGE STBD SIDE AFT.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Fire Fighting
Issued 29 April 1988 Resolved
REPAIR OR REPLACE DRESSER COUPLINGS FOR FIREMAIN STBD SIDE AT FS #14 AND #10.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Engineering
Issued 29 April 1988 Resolved
REPAIR REMOTE SHUT DOWN FOR #2 HEAVY OIL PURIFIER.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Engineering
Issued 29 April 1988 Resolved
E7 HYDRO RUSTON & HORNSBY AIR RECEIVER TO 1 1/2 TIMES MAWP. MAWP IS 355, TEST AT 533PSI.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Fire Fighting
Issued 29 April 1988 Resolved
REPAIR OR REPLACE FIRE PUMP RELIEF VALVE ON MAIN DECK.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
REPAIR OR REPLACE AUDIBLE ALARM FOR DUCT KEEL BILGE ALARM.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Lifesaving
Issued 29 April 1988 Resolved
INSTALL SHROUD ON PORT AND STBD LIFE BOAT DAVIT WINCHES.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Engineering
Issued 29 April 1988 Resolved
REPAIR BOILER #23686 FOR PROPER OIL FIRE OPERATION AND SET AND SEAL SAFETIES.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
REPAIR OR REPLACE RELIEF VALVE ON STARBOARD AIR RECIEVER AND TEST FOR OPERATION AT LESS THAN 430 PSI AND PROPER RESEATING.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
REPAIR W/T DOOR OPERATING WHEEL NEXT TO CO2 ROOM
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
REPLACE GASKET ON PORT AND STBD DOORS FOR BOS'N STORES IN FO'C'SLE.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
FREE BILGE WELL REACH ROD FOR FWD TRUNK LOCATED MIDSHIPS AFT OF #1 CARGO HOLD.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
REPLACE GASKET ON FOUR (4) NATURAL VENTS TO BOS'N STORES AND FWD PUMP ROOM.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
REPLACE GLASS ON PORT HOLES FOR GALLEY.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
INSERT STEEL OF SAME GAUGE WHERE HOLE IS LOCATED IN AFT HOUSE AT ENTRANCE TO GALLEY.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Lifesaving
Issued 29 April 1988 Resolved
PROVIDE INTERIOR SIGNS TO EMBARKATION DECK FOR LIFE BOATS.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Fire Fighting
Issued 29 April 1988 Resolved
PROVIDE ACCESS KEY BOX FOR EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Electrical
Issued 29 April 1988 Resolved
REMOUNT JUNCTION BOX AT STAIRTOWER PORT SIDE AFT TO LOWER DECK BERTHING.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Accommodation/Occupational Safety
Issued 29 April 1988 Resolved
REPLACE BROKEN GLASS IN [name withheld].
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Lifesaving
Issued 29 April 1988 Resolved
REMOVE WELDING ROD FROM ACCOMODATION LADDER HAND RAILS AND REPLACE WITH TOGGLE PINS.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
REPLACE U-BOLT ON PIPING FOR HYDRAULIC LINE MAIN DECK MIDSHIPS AT HYDRAULICPUMP ROOM.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
REPLACE PIN ON #5 MAN-HOLE COVER TO CARGO ACCESS TRUNK.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Lifesaving
Issued 29 April 1988 Resolved
PROVIDE SOLAS LIFE SAVING EQUIPMENT TRAINING MANUAL.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 29 April 1988 Resolved
REPLACE GASKET ON PORT & STBD PAINT STORES DOORS.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Construction/Loadline
Issued 16 January 1986 Resolved
MAKE PERMANENT REPAIRS TO HOLE IN BALLAST PIPE LOCATED IN MACHINERY SPACE, LOWER LEVEL, ON PORT FORWARD SIDE.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Unknown
Issued 16 January 1986 Resolved
PROVIDE LEGIBLE LABEL PLATES FOR EACH LEVER AT THE FUEL SUCTION VALVE EMERGENCY RELEASE TRIP STATION.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Engineering
Issued 16 January 1986 Resolved
STOP LEAKS FROM ALL BOILER MOUNTS ON THE LOWER AUXILIARY BOILER.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Lifesaving
Issued 16 January 1986 Resolved
MAKE PERMANENT RREPAIRS TO THE LIMIT SWITCH CONTROL CIRCUIT FOR THE PORTABLE LIFEBOAT WINCH MOTOR. LIFEBOATS ARE TO BE RAISED MANUALLY UNTIL REPAIRS TO THE LIMIT SWITCH CONTROL CIRCUIT ARE COMPLETED.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Electrical
Issued 16 January 1986 Resolved
INSTALL HAND CONTROL LEVER ON MOTOR CONTROLLER TO THE EMERGENCY STEERING PUMP.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Engineering
Issued 16 January 1986 Resolved
CONDUCT OPERATIONAL TEST OF ALL ALARMS AND CONTROLS FOR THE LOWER AUXILIARYBOILER.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Electrical
Issued 16 January 1986 Resolved
PLACE GUARDS OVER, THE COUPLINGS OF THE FOLLOWING PUMPS: A/C FEED PUMP, AFTER BOILER FEED PUMP, DIESEL FUEL BOOSTER PUMP, SHAFT BEARING LUBE OIL TRANSFER PUMP, AND ALL THREE GENERATOR PRE-LUBE PUMPS.
Condition: Unknown
Due 16 January 1986
Resolved 16 January 1986
Lifesaving
Issued 19 January 1985 Resolved
CONDUCT FULL FIRE AND BOAT DRILL.
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Lifesaving
Issued 19 January 1985 Resolved
PERMANENTLY SECURE BOW LOOKOUT LIFE PRESERVER/EXPOSURE SUIT STOWAGE LOCKER ON FOC'SLE
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Accommodation/Occupational Safety
Issued 19 January 1985 Resolved
MAKE PERMANENT REPAIRS TO HOT WATER HEATER ELEMENT.
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Engineering
Issued 19 January 1985 Resolved
CLEAN AND REMOVE ALL RESIDUAL OIL FROM BILGES, PUMP CONTAINMENTS AND TANK CONTAINMENTS WITHIN MACHINERY SPACE.
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Engineering
Issued 19 January 1985 Resolved
PROVE OPERATION OF LOW WATER CUT OUT AND FLAME FAILURE CUT OUT ON WASTE HEAT BOILER. UNTIL PROVEN SATISFACTORY 1 MAN BOILER WATCH IS REQUIRED WHEN MANUALLY OIL FIRING BOILER.
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Electrical
Issued 19 January 1985 Resolved
REPLACE ALL MISSING GLOBES, GUARDS AND LIGHTS IN ALL LIGHITNG FIXTURES THROUGHOUT VESSEL.
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Unknown
Issued 19 January 1985 Resolved
PROVIDE CURRENT COPIES OF THE FOLLOWING U.S. REGULATIONS: 46 CFR SUBCHAPTERS E,F,I AND 33 CFR 1-199
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Electrical
Issued 19 January 1985 Resolved
PROVIDE BLANKS FOR MISSING FUSES IN POWER AND LIGHTING DISTRIBUTION PANELS.
Condition: Unknown
Due 19 January 1985
Resolved 19 January 1985
Electrical
Issued 18 February 1983 Resolved
REPLACE DEFECTIVE MICRO SWITCH ON #1 GENERATOR SWITCH BOARD PRIOR TO SAILING FOREIGN
Condition: Unknown
Due 18 February 1983
Resolved 18 February 1983

Ownership record