MAURY USCG vessel records Sign in
← All vessels

OCEAN MASTER VI

OCEAN MASTER VI is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 8 inspections since 1983, most recently in May 1991, along with 36 deficiencies.

Records from 1983 to 1991. Most recent: inspection, 29 May 1991.

Built
1982
Last inspected
29 May 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-54713

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (1983–1991)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2826 - Regulatory (Subpart C or D), Gross Ton
1780 - Regulatory (Subpart C or D), Net Ton
5117 - Dead Weight, Ton
6498 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

29 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247155
11 July 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914220
9 April 1989 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924010
2 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1235933
14 April 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014983
6 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985478
6 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985479
7 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278364

Deficiency record · 36

Lifesaving
Issued 9 April 1989 Resolved
PROVIDE 4 SERVICED CG APPROVED 25 MAN DAVIT LAUNCHED INFLATABLE LIFERAFTS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVIDE EQUIP FOR STBD L/B: 2 L/J W/LIGHTS,WHISTLE&REFLECTIVE TAPE,COMPASS LIGHTSTICKS,132QTS WATER,88LBS PROVISIONS,44LBS SWEETENED COND MILK,JACK- KNIFE,FISHING KIT,12 RED FLARES EA. PARACHUTE&HANDHELD,2 FLOATING ORANGE SMOKE SIGNALS ALL CG APPROVED,1QT ILLUMINATING OIL,1GAL STORM OIL&SER COMP,
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
RENEW 4 CARTRIDGES AND 4 ROCKET PROJECTILES FOR LINE THROWING GUN.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVIDE EQUIP FOR PORT L/B:2 LIFEJACKETS W/LIGHTS,WHISTLE&REFLECTIVE TAPE, COMPASS LIGHTSTICKS,132QTS WATER,88LBS PROVISIONS,44LBS SWEETENED COND MILKJACKNIFE,FISHING KIT,12 RED FLARES EA. PARACHUTE&HANDHELD,2 FLOATING ORANGESMOKE SIG.ALL CG APPROVED,ASPIRIN,1QT ILLUM.OIL,1GAL STORM OIL&SERV COMPASS
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
REPLACE THE FOLLOWING MISSING EQUIPMENT FOR VESSELS LIFEJACKETS: 110 LIGHTSAND 63 REFLECTIVE TAPE.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989 Resolved
PROVIDE 5 U.L. APPROVED 1 1/2"X50' FIRE HOSES.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
RENEW BOTH EXPIRED SELF-ACTIVATING SMOKE SIGNALS, APPROVED UNDER 46 CFR 160.057 AT THE LAUNCHABLE RING BUOY STATIONS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
RENEW 12 CG APPROVED RED PARACHUTE FLARES IN THE CONTROL ROOM.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Fire Fighting
Issued 9 April 1989 Resolved
PROVIDE FOR EACH OF THE TWO FIREMAN'S OUTFITS AN OXYGEN AND EXPLOSIVE METERLISTED BY UNDERWRITER'S LABORATORIES, INC. OR FACTORY MUTUAL AS EXPLOSION PROOF AND A SELF-CONTAINED BREATHING APPARATUS APPROVED UNDER 46 CFR 160. 011.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVE PROPER OPERATION OF EMBARKATION LADDERS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Electrical
Issued 9 April 1989 Resolved
PROVE PROPER OPERATION OF ALL H2S AND COMBUSTIBLE GAS SENSORS AND ALARMS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Accommodation/Occupational Safety
Issued 9 April 1989 Resolved
REMOVE COMPRESSED AIR DRYER RECEIVER FROM SERVICE AND REMOVE FROM RIG AS SCRAP.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Lifesaving
Issued 9 April 1989 Resolved
PROVIDE BRAKE COVER FOR PORT LIFERAFT WINCH.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 9 April 1989 Resolved
REPAINT ALL VESSEL HULL MARKINGS.
Condition: Unknown
Due 9 April 1989
Resolved 9 April 1989
Construction/Loadline
Issued 2 April 1989 Resolved
PROVIDE DIVERS REPORT FOR UNDERWATER HULL SURVEY TO [name withheld].
Condition: Unknown
Due 2 April 1989
Resolved 2 April 1989
Lifesaving
Issued 6 May 1985 Resolved
RENEW THE WXPIRED SELF-ACTIVATING SMOKE SIGNAL, (APPROVED UNDER 46 CRF 160.057), ON THE STARBOARD RING BUOY.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Accommodation/Occupational Safety
Issued 6 May 1985 Resolved
A RELIEF VALUE, (MEETING THE REQUIREMENTS OF 46 CFR 54.15), SHALL BE INSTALLED ON EACH OF THE 2 SANITARY HEAD TANKS.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Lifesaving
Issued 6 May 1985 Resolved
REPLACE THE WXPIRED (FOREIGN) FLARES IN THE STARBOARD MOTOR LIFEBOAT WITH 3HAND HELD RED PARACHUTE FLARES MEETING THE REQUIREMENTS OF 46 CFR TBL 94.- 20-10(A)(HH) WITH PARTICULAR NOTE TO "FOOTNOTE 3).
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Fire Fighting
Issued 6 May 1985 Resolved
PROVIDE AN OXYGEN METER LISTED BY FM/UL/CSA AS EXPLOSION PROOF FOR EACH OF THE 2 FIREMAN'S OUTFITS.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 6 CONTINUED) AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Electrical
Issued 7 February 1983 Resolved
PROVIDE ENGINE ALARMS FOR MAIN GENERATORS AND THE EMERGENCY GENERATOR AS REQUIRED BY 46 CFR 111.10-5 AND 112.50-1 AND UNTIL SUCH ALARMS ARE IN-
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 7 CONTINUED) STALLED AND OPERATIONAL, A CONTINUOUS LIVE-WATCH PER ENGINE ON THE LINE SHALL BE PROVIDED. COMPLETE PRIOR TO THE VESSEL BE-
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 7 CONTINUED) ING MANNED AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
CONDUCT HYDRO TEST OF 7500 PSI OF HICH PRESSURE MUD LINE ON DRILL FLOOR ANDALL FLEX HOSES. COMPLETE PRIOR TO THE VESSEL BEING MANNED AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAINS TO THE MODU OCEAN MASTER VI, DN652652.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Lifesaving
Issued 7 February 1983 Resolved
PROVIDE TWO APPROVED FLOATING ORANGE SMOKE DISTRESS SIGNALS, TWELVE AP- PROVED HAND RED FLARE DISTRESS SIGNALS AND TWELVE PARACHUTE RED FLARE DIS-
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 1 CONTINUED) TRESS SIGNALS FOR EACH LIFEBOAT AS PER 46 CFR 94.20-10 AND 94.20-159FF, GG, HH). COMPLETE PRIOR TO THE VESSEL BEING MANNED
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 1 CONTINUED) AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Fire Fighting
Issued 7 February 1983 Resolved
PROVIDE AT LEAST TWO COMPLETE FIREMAN'S OUTFITS AS PER 46 CFR 108.497.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Fire Fighting
Issued 7 February 1983 Resolved
PROVIDE TEN BCII APPROVED PORTABLE FIRE EXTINGUISHERS AND NECESSARY SPARES TO REPLACE EXISTING BCI'S TO COMPLY WITH FIRE CONTROL PLAN FOR GALLEY, EN-
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 3 CONTINUED) GINE ROOM, CRANES, DRILL FLOOR, EMERGENCY GENER- ATOR ROOM AS PER 46 CFR 108.493. COMPLETE PRIOR TO THE VESSEL BEING MANNED
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 3 CONTINUED) AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Lifesaving
Issued 7 February 1983 Resolved
PROVIDE AN APPROVED FIRST - AID KIT AS PER 46 CFR 108.707. COMPLETE PRIOR TO THE VESSEL BEING MANNED AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Deck/Cargo
Issued 7 February 1983 Resolved
PROVIDE SUITABLE FLEXIBLE HOSE FOR BOTH CRANE DIESEL FUEL-FILL NOZZLES AS PER 46 CFR 56.50-75(A)(2) AND 56.50-70(B)(2). COMPLETE PRIOR TO THE VESSEL
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Unknown
Issued 7 February 1983 Resolved
(REQUIREMENT 5 CONTINUED) BEING MANNED AND OPERATED.
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983
Fire Fighting
Issued 7 February 1983 Resolved
SUBMIT FOR REVIEW AND APPROVAL TO NEW ORLEANS USCG MMT, FIRE DETECTION SYS-TEM PLANS AS PER 46CFR 108.405. COMPLETE PRIOR TO THE VESSEL BEING MANNED
Condition: Unknown
Due 7 February 1983
Resolved 7 February 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.