MAURY USCG vessel records Sign in
← All vessels

GAZ MERIDIAN

GAZ MERIDIAN is a 1982 tank ship. The Coast Guard has recorded 24 inspections since 1986, most recently in June 2007, along with 22 deficiencies and 9 operational controls.

Records from 1986 to 2007. Most recent: inspection, 8 June 2007.

Built
1982
Last inspected
8 June 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8005408 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-54733

Inspections, by type

…with no type recorded12
Years with a record 10 calendar years (1986–2007)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it42694 - Regulatory (Subpart C or D), Gross Ton
12959 - Regulatory (Subpart C or D), Net Ton
45501 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

8 June 2007 COC-GAS Annual · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2955699
6 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2867817
22 January 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2859646
13 March 2006 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2601264
10 March 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2600236
8 October 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2216917
27 September 2004 COC-GAS Renew
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2206101
23 January 2003 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1734500
21 January 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1733217
2 December 2002 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1711620
27 November 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1712183
30 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1682110
29 January 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1482324
17 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295576
17 November 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1076150
16 November 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295629
19 October 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433878
26 January 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 424928
26 January 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 790000
27 June 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 404668
27 June 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1115787
5 September 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1140205
21 May 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 308952
21 May 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 988091

Deficiency record · 22

Fire Fighting › Ventilation Systems › Ducts
Issued 8 June 2007 Resolved
Vessel motor room and compressor room remote ventilation pulleys were missing. Vessel is to correct problem to the satisfaction of class and provide a report to Local [name withheld] 7/7/07.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 9 June 2007
Resolution: Received attestation from certificate issuing authority to the satisfactory repairs of this deficiency.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 8 June 2007 Resolved
Galley exhaust damper inoperative. Make repairs to satisfaction of class and provide report to local [name withheld] 6/22/07
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 9 June 2007
Resolution: Received attestation from certificate issuing authority to the satisfactory repairs of this deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 8 June 2007 Resolved
Vessels cargo manifold quick closing valves did not function properly. Vessel is to make repairs to satisfaction of class and provide report to local OCMI, prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2007
Resolution: Received attestation from certificate issuing authority to the satisfactory repairs of this deficiency.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 June 2007 Resolved
Vessel has 110 ground due to the possibility of ground being in a gas hazard zone no cargo operations until repairs have been to the satisfaction of class and report sent to local OCMI.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2007
Resolution: Received attestation from certificate issuing authority to the satisfactory repairs of this deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 June 2007 Resolved
Vessel electrical equipment installed on tank level circuits was modified vessel is to have class certify repairs and provide report to local [name withheld] 6/22/07.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 9 June 2007
Resolution: Received attestation from certificate issuing authority to the satisfactory repairs of this deficiency.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 June 2007 Resolved
Vessels electrical junction boxes in gas danger zone must be approved by class and provide report to local OCMI prior to cargo operations.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2007
Resolution: Received attestation from certificate issuing authority to the satisfactory repairs of this deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 22 January 2007 Resolved
#3 cargo pump is inoperable.
Condition: Unknown
Due 22 January 2007
Resolved 26 January 2007
Resolution: Received Class report satisfactorily addressing inoperability of carpo pump and action to be taken.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 13 March 2006 Resolved
Cargo relief valves were not sealed in accordance with I.G.C. 8.2.5. Requested class report to setting of new seals.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2006
Resolution: Received class attestation that the vrelief valves were hydrostatically tested and sealed, cleared deficiency.
Deck/Cargo › Cargo Stowage › General
Issued 13 March 2006 Resolved
Compressor room was not made available for examination. Compressor room shall be made available in next us port.
Action required: 705 - Other - as specified
Due 23 March 2006
Resolved 13 November 2006
Resolution: Satisfactorily inspected the compressor room.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 March 2006 Resolved
The oily water separator was missing class approval of the installation. Provide class attestation to class approval prior to operating.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 March 2006
Resolution: Received class report, cleared deficiency.
Engineering › Fuel Oil Service System › Pump
Issued 13 March 2006 Resolved
No. 3 AUX generator has leak on the fuel pump . Requested class report
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 March 2006
Resolved 17 March 2006
Resolution: Received class report, cleared deficiency.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 13 March 2006 Resolved
No.1 aux generator has fuel oil leak at #8 cylinder head. Requested class report to repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2006
Resolved 17 March 2006
Resolution: Received class report, cleared deficiency.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 13 March 2006 Resolved
Economizer boiler superheat outlet elbow leaks steam at both flanges. requested class report for repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 17 March 2006
Resolution: Received class report, cleared deficiency.
Engineering › Diesel Engine (auxiliary) › Pump, Positive Displacement
Issued 13 March 2006 Resolved
The emergency generator has a minor fuel oil leak at the fuel pump.
Action required: 705 - Other - as specified
Due 19 March 2006
Resolved 17 March 2006
Resolution: Received class report, cleared deficiency.
Deck/Cargo
Issued 2 December 2002 Resolved
Prior to next US port, repair/replace ventilation dampener in the motor and power pack room, vent T-10 (wasted). All repairs to be made to the satisfaction of the administration.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 January 2003
Deck/Cargo
Issued 2 December 2002 Resolved
Prior to next US port, replace/repair outer air lock door knife edge to the motor and power pack room. ( day light comes through when the door is dogged shut.) All repairs to be made to the satisfaction of the administration.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 January 2003
Fire Fighting
Issued 27 June 1997 Resolved
REPAIR WATER SPRAY PIPE TO RELIQ. PLANT ROOM LINE WHERE LEAKS. COMPLETE TOSATISFACTION OF CLASS.
Condition: Unknown
Due 28 June 1997
Resolved 16 July 1997
Fire Fighting
Issued 27 June 1997 Resolved
INSTALL FIRE DAMPER IN PAINT LOCKER VENTILATOR. COMPLETE TO SATISFACTION OFCLASS.
Condition: Unknown
Due 28 June 1997
Resolved 16 July 1997
Deck/Cargo
Issued 27 June 1997 Resolved
PROVE PROPER OPERATION OF THE INERT GAS SYSTEM.
Condition: Unknown
Due 27 June 1997
Resolved 16 July 1997
Engineering
Issued 27 June 1997 Resolved
RENEW FLAME SCREENS TO FWD MOTOR ROOM INBOARD SUPPLY AND EXHAUST VENTILATORS. COMPLETE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 28 June 1997
Resolved 16 July 1997
Fire Fighting
Issued 27 June 1997 Resolved
REPAIR FLANGE ON WATER SPRAY SYSTEM BETWEEN #1 & #2 CARGO DOME. COMPLETE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 28 June 1997
Resolved 16 July 1997
Deck/Cargo
Issued 5 September 1993 Resolved
At the next U.S. port, provide evidence of satisfactory hydrostatic testingof the vessel's cargo hoses.
Condition: Unknown
Due 5 September 1993
Resolved 5 September 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.