← All vessels
CHAMPION
CHAMPION is a 1983 tank ship. The Coast Guard has recorded 76 inspections since 1984, most recently in January 2011, along with 70 deficiencies — 8 with no resolution recorded — and 7 operational controls.
Records from 1984 to 2011. Most recent: inspection, 25 January 2011.
- Built
- 1983
- Last inspected
- 25 January 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 70 recorded · 8 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8028163 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAJA5
54734
Flag
BAHAMAS, THE
—
Maury page id
psix-54734
Inspections, by type
…with no type recorded47
…past their stated due date7
Years with a record
25 calendar years (1984–2011)
The 76 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it21796 - Convention (Subpart B), Gross Ton
11803 - Convention (Subpart B), Net Ton
38084 - Dead Weight, Ton
47915 - Displacement, Ton
11803 - Convention (Subpart B), Net Ton
38084 - Dead Weight, Ton
47915 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 76
25 January 2011
MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3933070
25 January 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3934887
21 January 2011
COC-CHEM Annual · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3930109
13 March 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3694862
16 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3536537
11 July 2009
MARPOL Annex II Examination · PI Safety Exam · MARPOL Annex VI Survey · MARPOL Annex V Examination · COC-CHEM Renew · ISPS I Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3522819
11 July 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3530746
11 July 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3533308
10 July 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3522804
10 July 2009
Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3543690
12 February 2007
MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · COC-CHEM Renew · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2870454
11 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2868355
7 February 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2868457
18 August 2006
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2752100
10 December 2005
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2549165
5 December 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2548557
18 January 2005
COC-TVE Renew
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2276861
3 July 2004
PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2119662
23 June 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2107807
18 June 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2102856
24 November 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1953188
4 December 2002
Certificate of Compliance
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1714875
2 April 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600149
4 February 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1483674
20 December 2001
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1474032
21 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1074480
9 June 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 291004
16 May 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 290037
8 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 114023
26 May 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278208
26 May 2000
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817753
10 October 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 421259
10 October 1998
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 801705
1 October 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 421017
1 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461082
7 February 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 412552
12 September 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 407774
12 September 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 786508
6 June 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 404378
6 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403212
18 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1094100
16 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398708
6 February 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 387627
7 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 383682
30 September 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 383153
30 September 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1182692
22 May 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 378462
27 October 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 868503
26 October 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 371698
8 February 1994
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 854099
7 October 1993
Letter of Compliance (Initial/Renewal)
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1434066
26 October 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 353918
26 October 1992
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1253506
15 August 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 493282
28 January 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 646877
21 January 1992
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 445843
23 September 1991
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1310019
19 August 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 939699
8 July 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 344710
8 July 1991
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248879
25 November 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 519328
18 May 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 507790
18 May 1989
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1200208
18 May 1989
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1277374
2 March 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 445007
20 September 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1352078
19 September 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 467812
22 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 509649
22 February 1988
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024255
28 November 1987
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 512572
12 July 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 317265
12 July 1987
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1326640
17 November 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 466949
18 April 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 308032
11 June 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 978402
18 September 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298252
Deficiency record · 70
Engineering › Lubricating Oil Service System › Tube
Issued 25 January 2011
Resolved
2199 Discharge of oil shall be prohibited. A discharge of approximately 50 liters of lube oil from the stern tube lower packing gland while in the port of Stockton, CA. Repair packing gland to the satisfaction of class/flag/USCG. 17abc
Engineering › Lubricating Oil Service System › Valve, Control
Issued 25 January 2011
No resolution recorded
1499 The automatic temperature control valves for delivery of jacket water, lube oil, and fresh water cooling systems are missing or non-functional and must be operated manually. 70ab
Engineering › Compressed Air System (start air) › Piping
Issued 25 January 2011
No resolution recorded
1499 The start air delivery lines to the #2 and #4 cylinders on the main engine are excessively patched. 70ab
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 25 January 2011
No resolution recorded
1499 Gauges for fuel pumps in the purifier room are cracked or broken preventing accurate readings of pressure for the fuel purifying system. 70ab
Engineering › Compressed Air System (start air) › Compressor
Issued 25 January 2011
No resolution recorded
0950 Exposed metal parts of electrical machines which are liable to become live shall be so insulated that the danger of injury does not exist. Exposed electrical wiring on #2 air compressor presents a shock to crew. 70ab
Engineering › Compressed Air System (start air) › Valve
Issued 25 January 2011
No resolution recorded
1499 A valve on the delivery line from the #2 starting air reservoir is being held shut with a metal clamp, preventing proper operation of the system. 70ab
Accommodation/Occupational Safety › Ventilation › General
Issued 25 January 2011
No resolution recorded
0999 Crew has modified ventilation ducting near ship's service air reservoir with piping and other non approved materials. 70ab
Construction/Loadline › Markings › Load Line Mark
Issued 25 January 2011
No resolution recorded
1299 Load line shall be painted in a contrasting color. Load line and associated markings are not properly marked on the ship's hull. 70 ab
Deck/Cargo › Inert Gas System › Boiler Uptake
Issued 21 January 2011
No resolution recorded
Master chose not to fire the vessel boiler and start the IGS system to conduct system checks as the vessel is due to be scrapped after offloading. Vessel may not carry cargoes requiring IGS in U.S. waters pending inspection of the system.
Engineering › Lubricating Oil Service System › Filter
Issued 11 July 2009
Resolved
The vessel experienced a power irregularity while transiting the lower MS river, the apparent cause was due to shifting from the No.1 to the No.2 lube oil filter while the engine was at 90 RPM's.
Deck/Cargo › Vapor Control Systems › Flame Arresters
Issued 24 November 2003
Resolved
Ballast tank vent flame screen missing on tanks 2S, 2P, 3P, and 9S. Correct to satisfzction of Lloyds surveyor prior to departing the port of NY.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 24 November 2003
Resolved
IG Main found with pinhole leak near port side slop tank. This to be corrected to satisfzction of Lloyds surveyor prior to departing the port of NY. LEGACY COMPONENT DESC: Piping
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 24 November 2003
Resolved
PV Vent stack to cargo tank 3S found with pinhole leak and must be corrected to satisfaction of Lloyds surveyor prior to departing the port of NY.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 24 November 2003
Resolved
No suitable secondary means of starting the emergency generator found to exist. Noted possible modifications to starting system that nullified old secondary starter. This condition shall be corrected to satisfaction of Lloyds surveyor prior to departing the port of NY.
Construction/Loadline › Markings
Issued 4 December 2002
Resolved
Vessel is displaying 2 loadlines. 1 approx. 1 meter above the other. Required removal of unauthorized loadline or class approval of 2 separate loadlines. LEGACY COMPONENT DESC: Load Line Mark
Deck/Cargo › Inert Gas System
Issued 4 December 2002
Resolved
Prove proper operation of Inert Gas System. Inert Gas Boiler was not fired up at the time of inspection.
Documentation › Certificates/Documents
Issued 4 December 2002
Resolved
Vessel has gone through at least two changes of name/ownership/management since issue of Vapor Recovery Certification. Unable to match certification to vessel.
Fire Fighting › Ventilation Systems
Issued 4 December 2002
Resolved
Ventilation to Emergency Generator Room is missing closure device. No means to secure ventilation in the event of fire in the space. LEGACY COMPONENT DESC: Duct Hatches
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 December 2002
Resolved
self igniting light on ring buoy not working.
Deck/Cargo › Inert Gas System
Issued 20 December 2001
Resolved
Prove proper operation of the IGS to include all alarms and shutdowns. LEGACY COMPONENT DESC: Alarms
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 December 2001
Resolved
Prove proper operation and calibration of the SAAB Radar tank gauging system to include the main cargo control console tank level indicators.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 December 2001
Resolved
Prove proper operation of all cargo tank high level and overfill alarms. (3 systems)
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 December 2001
Resolved
Prove proper operation of all cargo valve remote position indicators on the cargo control console.
Deck/Cargo
Issued 16 May 2001
Resolved
High Oxygen content alarm not working._x001C_ SOLAS 74/78 Chp II-2 Reg 62.19.1.5
Fire Fighting
Issued 16 May 2001
Resolved
Valve on bleed off line for the emergency fire-pump needs to be replaced._x001C_ SOLAS 74/78 Chp II-1 Reg 26.1
Deck/Cargo
Issued 16 May 2001
Resolved
#1 Stbd tank ullage has a bad gasket._x001C_ ILLC 66 Annex 1/15_x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 1 October 1998
Resolved
Piping for outer slop tank is holed and wasted. _x001C_ (SOLAS 74 REG I/11)
Navigation
Issued 1 October 1998
Resolved
Emergency steering gear inoperable. _x001C_ (SOLAS 74 REG II-2/5)
Fire Fighting
Issued 1 October 1998
Resolved
Emergency fire pump does not provide adequate pressure._x001C_ (SOLAS 74 REG II-1/29)
Deck/Cargo
Issued 1 October 1998
Resolved
Prior to using Inert Gas System in U.S. water demonstrate systems to the satisfaction of your class society and provide report to nearest U.S. CoastGuard Marine Safety Office.
Fire Fighting
Issued 1 October 1998
Resolved
Prior to departing the port of New Orleans make permanent repairs to the emergency fire pump and demonstrate to the satisfaction of your class society 2 effective streams from 2 hoses simultaneously.
Navigation
Issued 1 October 1998
Resolved
Prior to departing the port of New Orleans make permanent repairs to emergency steering gear and demonstrate to your class society.
Deck/Cargo
Issued 1 October 1998
Resolved
Prior to departing the port of New Orleans make permanent repairs to the port outer slop tank transfer line where wasted and holed.
Navigation
Issued 1 October 1998
Resolved
Prior to or at next U.S. port call replace blown motor controller light bulbs.
Lifesaving
Issued 1 October 1998
Resolved
Prior to or at next U.S. port call make permanent repairs to engine visual alarm.
Unknown
Issued 1 October 1998
Resolved
Prior to or at next U.S. port call provide documentation from your class society that the oil discharge monitoring system is operating properly and has been installed properly.
Unknown
Issued 1 October 1998
Resolved
Prior to or at next U.S. Port Call have damaged oily water separator gaugesreplaced.
Lifesaving
Issued 6 May 1997
Resolved
Replace lifeline (30M) on both lifebuoys located forward of #1 cargo tank._x001C__x001C_ _x001C_ SOLAS 74, ChapIII/7
Documentation
Issued 16 December 1996
Resolved
UPDATE SAFE MANNING CERTIFICATE. VESSEL NO LONGER REQUIRES RADIO OPERATOR SINCE GMDSS IS ON BOARD. (SOLAS 74 (amended) REG V/13). CORRECT BY 18JAN97.
Navigation
Issued 16 December 1996
Resolved
ECHO DEPTH SOUNDER NOT OPERATING PROPERLY. (33 CFR 164.35(i)). CORRECT BY 18JAN96.
Engineering
Issued 16 December 1996
Resolved
UNABLE TO DEMONSTRATE PROPER OPERATION OF OILY WATER SEPERATOR. (33 CFR 155.380) CORRECT BY 18JAN97.
Electrical
Issued 16 December 1996
Resolved
NON-CONDUCTIVE MATS NOT LOCATED AT MAIN OF EMERGENCY SWITCH BOARDS. (SOLAS 74 (unamended) REG II-1/45.1) CORRECT BY 18JAN97.
Deck/Cargo
Issued 16 December 1996
Resolved
STEAM LEAK AT #2 CARGO TANK VALVE. (SOLAS 74 (amended) REG II-2/56) CORRECTBY 18JAN97.
Deck/Cargo
Issued 16 December 1996
Resolved
AUDIBLE ALARM FOR IGSW MAIN PRESSURE AND VISUAL ALARM FROR DECK SEAL FLOW INOPERATIVE. (SOLAS (amdended) REG II-2/62.19.1) CORRECT BY 18JAN97.
Deck/Cargo
Issued 16 December 1996
Resolved
UNABLE TO DEMONSTRATE OPERATION OF CARGO TANK "HI" AND "HI-HI" LEVEL ALARMS(AUDIBLE AND VISUAL).
Navigation
Issued 16 December 1996
Resolved
CORRECT 4o ERROR TO PORT IN MAIN STEERING SYSTEM. (SOLAS 74 (unamended) REGII-1/29(a)iv). CORRECT BY 18JAN97.
Deck/Cargo
Issued 30 September 1995
Resolved
REVIEW OF THE INSTALLED VAPOR CONTROL SYSTEM, (VCS) WITH THE ABS APPROVED PLANS REVEALS THAT THE SYSTEM, AS INSTALLED DOES NOT CONFIRM TO ANY PLANS. PRIOR TO VSL. REQUESTING CERTIFICATION OF IT'S VCS BY USCG, CLASSIFICATION SOCIETY SHOULD CONDUCT A COMPLETE REVIEW IAW 46CFR39.
Lifesaving
Issued 30 September 1995
Resolved
AT NEXT U.S. PORT HAVE CERTIFIED MARINE CHEMIST CERTIFY THE CARGO PUMPROOM AS SAFE FOR ENTRY. MAKE ARRANGEMENTS FOR THE LOCAL U.S. COAST GUARD TO EXAMINE THE CARGO PUMPROOM. ITEM NOT INSPECTED IN STX DUE TO HURRICANE RECOVERY.
Lifesaving
Issued 30 September 1995
Resolved
MAKE PROPER REPAIRS TO THE PORT SIDE FWD. EMERGENCY SHOWER PRIOR TO THE NEXT U.S. PORT VISIT.
Deck/Cargo
Issued 30 September 1995
Resolved
MAKE THE HIGH/HIGH HIGH LEVEL VISUAL ALARMS LOCATED ON THE DECK HOUSE SUPERSTRUCTURE OPERATIONAL. BULBS BURNED OUT. (NOTE THAT THE VISUAL ALARMS LOCATED ON DECK CAN BE OBSERVED FROM THE DECK AND PILOT HOUSE AREAS.
Lifesaving
Issued 30 September 1995
Resolved
PROVIDE AS NEEDED RETROREFLECTIVE TAPE ON RING BUOYS
Lifesaving
Issued 30 September 1995
Resolved
MAKE PROPER REPAIRS TO THE STBD SIDE MIDSHIPS EMERGENCY SHOWER VALVE HANDLEAND PROVE OPERATION AT NEXT U.S. PORT VISIT.
Lifesaving
Issued 7 October 1993
Resolved
PRIOR TO CARRIAGE OF FLAMMABLE OR COMBUSTIBLE PRODUCTS IN U. S. WATERS; MAKE PERMANENT REPAIRS TO THE S/S AIR SYSTEM WHERE IT IS WASTED AND HOLED. (AIR LEAK DETECTED AMIDSHIP, FORWARD OF STARBOARD SIDE DECK STOREROOM)
Lifesaving
Issued 7 October 1993
Resolved
PRIOR TO CARRIAGE OF FLAMMABLE OR COMBUSTIBLE PRODUCTS IN U. S. WATERS; PROVIDE SPAN GAS FOR CALIBRATION OF PORTABLE GAS DETECTION INSTRUMENTS.
Deck/Cargo
Issued 7 October 1993
Resolved
PRIOR TO CARRIAGE OF FLAMMABLE OR COMBUSTIBLE PRODUCTS IN U. S. WATERS; CONDUCT THE ANNUAL TEST ON ALL PORTABLE CARGO HOSES.
Construction/Loadline
Issued 7 October 1993
Resolved
PRIOR TO CARRIAGE OF FLAMMABLE OR COMBUSTIBLE PRODUCTS IN U. S. WATERS; PROPERLY INSTALL FLAMESCREENS IN ALL WING BALLAST TANK VENTS.
Deck/Cargo
Issued 26 October 1992
Resolved
OPERATE IGS AS PER 46CFR 32.53-5, 32.53-30. CARGO TANKS MUST HAVE A POSITIVE PRESSURE OF 100 MILLIMETERS (4 INCHES) OF WATER UNLESS THE TANK ISGAS FREE.
Deck/Cargo
Issued 26 October 1992
Resolved
REPLACE IMPROPER SIZE FLAME SCREEN IN THE BUNKER,COFFERDAM,FUEL OIL,AND CARGO VENTS. CHECK ALL OTHER VENTS TO ENSURE THAT THE CORRECT SIZE FLAME SCREEN IS INSTALLED AND REPLACE AS NECESSARY. REFERENCE 46 CFR 30.10-25
Accommodation/Occupational Safety
Issued 8 July 1991
Resolved
THE CLASSIFICATION SOCIETY SHALL INSPECT BOTH PAINT LOCKERS TO DETERMINE IFA POTENTIAL ELECTRICAL SAFETY HAZARD EXISTS, IN ACCORDANCE WITH 83 SOLAS, CHAPTER II-I REG 45.10. THE CLASSIFICATION SOCIETY SHALL PROVIDE A WRITTEN REPORT TO THE [name withheld], HI, UPON COMPLETION OF INSPECTION.
Deck/Cargo
Issued 8 July 1991
Resolved
ENSURE CORRECT FIT AND SEAL OF ALL ULLAGE FLAME SCREENS.
Fire Fighting
Issued 8 July 1991
Resolved
HAVE THE CORRECT NUMBER OF SATISFACTORILY TESTED FIRE HOSES ONBOARD.
Fire Fighting
Issued 8 July 1991
Resolved
CONDUCT CURRENT SERVICE ON ALL FIXED FIRE SUPPRESSION SYSTEMS.
Deck/Cargo
Issued 18 May 1989
Resolved
THE CLASSIFICATION SOCIETY SHALL PROVIDE A WRITTEN REPORT TO [name withheld], TEXAS UPON COMPLETION OF THIS REQUIREMENT BUT IN NO CASE LATER THAN 18JUN89.
Deck/Cargo
Issued 18 May 1989
Resolved
PRIOR TO THE CARRIAGE OF ANY CARGO WHICH REQUIRES AN INERT ATMOSPHERE IN U. S. WATERS, PROVE PROPER OPERATION OF AND CONDUCT THOROUGH TESTING OF INERT GAS SYSTEM TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY.
Deck/Cargo
Issued 18 May 1989
Resolved
THE CLASSIFICATION SOCIETY SHALL PROVIDE A WRITTEN REPORT TO [name withheld], TEXAS UPON THE COMPLETION OF THIS REQUIREMENT BUT IN NO CASE LATER THAN 18JUN89.
Deck/Cargo
Issued 18 May 1989
Resolved
PROVE PROPER OPERATION AND CONDUCT THOROUGH TESTING OF OIL DISCHARGE MONITOR TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY.
Deck/Cargo
Issued 20 September 1988
Resolved
DEMONSTRATE PROPER OPERATION OF IGS TO USCG MARINE INSPECTOR AT NEXT US PORT OF CALL AFTER COMPLIANCE DATE.
Fire Fighting
Issued 12 July 1987
Resolved
PROVIDE FOAM FIRE FIGHTING INSTRUCTIONS IN A LANGUAGE READILY UNDERSTOOD BYALL CREW MEMBERS. POST THE INSTRUCTIONS AT THE DECK FOAM OPERATING STATION
Documentation
Issued 12 July 1987
Resolved
PROVIDE UP TO DATE PUBLICATIONS OF 46 CFR 35 AND 153.
Unknown
Issued 11 June 1985
Resolved
ONE CATEGORY TWO DEFICIENCY NOTED - MISSING TOXIC GAS DETECTION FOR CARGOESOTHER THAN BENZENE OR XYLENE. REQUIRED DETECTORS TO BE OBTAINED PRIOR TO CARRYING CARGO FOR WHICH TOXIC GAS DETECTION IS REQUIRED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.